• Title/Summary/Keyword: Klystron

Search Result 47, Processing Time 0.037 seconds

Design Efforts of PAL XFEL RF Components to Reduce RF Breakdown Due to Surface Electric Gradient in High Power Operation

  • Ju, Yeong-Do;Park, Yong-Jeong;Lee, Heung-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.239-239
    • /
    • 2013
  • The peak klystron power for the PAL (Pohang Accelerator Laboratory) XFEL (X-ray Free Electron Laser) is up to 80 MW which is higher than that of PLS-II LINAC. To prevent the RF breakdown such a high power operation, some of RF components need to be redesigned to reduce the surface electric field gradient to be less than the breakdown gradient at the vacuum-metal surface. For instances, the redesign of the Stanford Linear Accelerator Energy Doubler (SLED) system, the directional coupler and 3dB power splitter using the finite-difference time-domain (FDTD) simulation will be presented.

  • PDF

Study on the high precision output of 50kV high-voltage inverter (50kV 고전압 인버터 고정밀 출력설계에 관한 연구)

  • Son, Y.G.;Suh, J.H.;Oh, J.S.;Cho, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2199-2201
    • /
    • 2005
  • High voltage power supply with pulse load($4.5{\mu}s$ and PRF 60Hz) condition is investigated which is of interest for applications like Klystron modulator power supplies with output voltage of 50kV. The performance specifications with this type of power supplies are very stringent demanding tight regulation(<0.01%) and high efficiency(> 85%). The solution to this problem as a single stage converter is very difficult. The final output voltage is obtained as sum of the output of SCPS & PCPS. The combination of the two stages can satisfy the pulse load specifications. The analysis of the voltage and power division between SCPS & PCPS has been done for the proposed topology. It has studied under various operating conditions of line and load. Simulation results are validated by experimental results.

  • PDF

High Power Microwave Resonant Ring (고출력 마이크로파 Resonant Ring)

  • Park, S.S.;Park, S.W.;Kim, S.H.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1275-1277
    • /
    • 1995
  • We designed and constructed an extremly high power s-band traveling wave resonator for the test of high power microwave components using 80MW pulsed klystron with $4{\mu}s$ pulse width. The 10dB directional coupler for the input power coupling was used, and the ring consists of phase shifter, tuner, H-band, and other microwave components. The designed total electrical length of the system is 10 times of the waveguide wavelength, ${\lambda}_g$=15.3cm, and the measured total insertion loss is 0.15dB. The low power test measurment showed the power multiplication of 14.69. The design goal is to achieve the peak power of 300MW, pulse width $4{\mu}s$ with 30 pulse repetition rate. In this article we discuss the treveling wave resonant ring constructed at the PAL laboratory together with the test results.

  • PDF

Characterization of the Hydrogen Reservoir for a High Power Gas Switch

  • Lee, B.J.;Park, S.S.;Kim, S.H.;Kwon, S.J.;Jang, S.D.;Joo, Y.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.261-261
    • /
    • 2012
  • This paper presents the understandings carried out for the installation of the hydrogen reservoir of the multi-gap pseudospark switch under developing for the accelerator applications. As a cold cold cathode switch, the pseudospark switch could replace the thyratron switch which has hot cathode and being used well currently in the high power field such as laser and accelerator applications. Especially in the klystron modulator, the key component is a switch which mostly defines the jitter and the instability of the modulator system. To get the less jitter and the instability, we need to find proper range of the pressure for the gas discharge inside gas switch. This could be achieved by the understanding of the characteristic of the nonevaporable getter (NEG) which is used as a hydrogen reservoir for the switch. Therefore we verified the characteristics of the NEG (St 172, Saes) and its installation in the switch. Finally we controlled the getter to find best pressure point for the pseudospark switch.

  • PDF

Study on High Voltage Switch Using IGBT (IGBT를 사용한 고전압 스위치에 관한 연구)

  • Park, S.S.;Kim, S.C.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.556-558
    • /
    • 1996
  • PLS 2-GeV linac has 11 sets of high power klystron-modulator system as a main RF source for the beam acceleration. The modulators can provide 200-MW peak pulsed power(400-kV, 500-A) with a pulse width of $7.5{\mu}s$(ESW), a maximum pulse repetition rate of 120-Hz at the full power level. The DC power supply provides a 25-kV, 7-Adc and the charging system consists of a charging inductor, charging capacitor, and the diode for reverse current protection. The charged PFN voltage by a LC resonant charging method has two times of the DC high voltage and the pulsed power is delivered to the load by a thyratron switch. To reduced the press of high voltage lit thyratron switch, the command charging is the best method. In this article, the high voltage switch for the command charging method is tested to the start work and the system is presented with the experiment results of the trigger and operational characteristics.

  • PDF

A Study on Microwave-FM-CW Detection System for the Sutomatic Optimal Point Traffic Control (교통신호의 자동최적점제어를 위한 마이크로파 FM-CW 검지계통에 관한 연구)

  • 양흥석;김호윤
    • 전기의세계
    • /
    • v.22 no.1
    • /
    • pp.35-41
    • /
    • 1973
  • An automatic point traffic control method is recommended for more idealistic traffic flow over coarse road netowrks. The automatic control apparatus recommended, consists of a transceiver, amplifier, digital-to-analog converter, signal light controller for emergency and steady state, and digital counter as monitor. The transmitter sends a signal to the target vy means of Microwave-FM-CW and a diode detector picks up the echo signal. Thus the operation of the entire system will be carried out through an open loop state. Some factors necessary for an ideal detector system are rapid response, longevity and stability. An analytical method of the Doppler effect substitutes the conventional frequency deviation into the amplitude of detector output. The changing rate of amplitude is proportional to the voltage of the detector output. Some induced formula from Maxwell's radiation field theory ensures this new method, and, new method, and proves the fact with an experimental data presentation. Stability depends upon Klystron as an oscillator and a diode as a detector. the transceiver installation affects on the response and sensitivity of the system. In accordance with the detector output, several targets are easily classified by amplitudes on the scope. The traffic flow, i.e., target movement which is analyzed by the amplitude method, is shown through the scope and indicates it on the digital counter. The best efficiency for the amplitude analysis can be attained through use of an antenna having the highest sensitivity.

  • PDF

Cutting Characteristics of Oxygen-Free Using the Ultra Precision Machining (초정밀가공기를 이용한 무산소동 절삭특성)

  • 고준빈;김건희;원종호
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.12
    • /
    • pp.120-126
    • /
    • 2002
  • The needs of ultra-precisely machined parts are increasing more and more. But the experimental data required to ultra precision machining of nonferrous metal is insufficient. The behavior of cutting in micro cutting area is different from that of traditional cutting because of the size effect. Copper is widely used as optical parts such as LASER reflector's mirror and multimedia instrument. In experimental, after oxygen-free copper is machined by ultra precision machine with natural mono crystal diamond tool (NCD) and synthetic poly crystal diamond tool (PCD), we compared chip formation and tool's wear according to used tool. Also, we researched optimized cutting condition with the results measured according to cutting condition such as spindle speed, feed rate and depth of cut. As a result, the optimal working condition that makes good surface roughness is obtained. The surface roughness is good when spindle speed is above 80 m/min, and feed rate is small and depth of cut is above 0.5 ${\mu}{\textrm}{m}$. In cutting of klystron anode and cavity 3.2 nmRa of surface roughness is obtained.

Capacitive Voltage Divider for a Pulsed High-Voltage Measurement (펄스형 고전압 측정용 용량성 전압 분배기)

  • Jang, S.D.;Oh, J.S.;Son, Y.G.;Cho, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1612-1615
    • /
    • 2001
  • 포항 방사광 가속기 2.5 GeV의 전자선형 가속기는 마이크로웨이브 발생원으로써 80 MW 클라이스트론(klystron) 11대와 입사부에 65 MW 클라이스 트론 1대를 사용한다. 전자빔 에너지의 효율적인 제어를 위하여 고출력 클라이스트론의 RF 전력과 입력 빔의 전력을 정확하게 측정해야 하며 응답특성이 양호한 측정장치와 정밀한 측정이 요구된다. 클라이스트론에 공급되는 전력은 캐소드에 인가되는 전압과 전류의 측정치로 계산된다. 비록 빔 전압측정에서의 작은 오차일지라도 클라이스트론 RF 출력 전력의 결과값에 큰 영향을 미친다. 따라서, 빔 전압의 측정시에 정확한 측정을 위하여 특별한 주의가 요구된다. 고전압 펄스전원장치 인 모듈레이터 (modulator)에서 발생되는 수백 kV(350-400 kV)의 전압을 측정하기 위하여 커패시터의 용량비로 입력전압을 분압하는 용량성 분압기(capacitive voltage divider, CVD)가 사용된다. 고압측 분압용 표준 콘덴서의 정전용량을 결정하는 주요인자는 고전압 절연유의 유전율(dielectric constant)이다. 그러므로, 측정범위 내의 전압, 주파수, 온도에 대하여 정전용량의 변화율이 작도록 설계하여야 한다. 본 논문에서는 펄스형 고전압 신호 측정을 위한 용량성 전압 분배기의 측정원리, 설계분석, 교정시험, 절연유의 온도변화에 따른 정전용량 변화 특성에 대한 실험 결과를 고찰하고자 한다.

  • PDF

Operation Characteristic and Harmonic Analysis of 200-MW Modulator (200-MW 모듈레이터의 동작 특성 및 고조파 해석)

  • Park, S.S.;Oh, J.S.;Cho, M.H.;NamKumg, W.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1577-1579
    • /
    • 1994
  • 200-MW pulse modulators(total 11units) for the PLS linac employ the SCR phase control circuit. It controls 3-phase AC line voltage for the high-voltage DC power supply (DCPS, maximum of 25kVDC, 4.2A) which charges the pulse forming network(PFN). The PFN delivers 400kV, 500A, ESW $7.5{\mu}s$ pulse power to the 80-MW klystron amplifier tube. The SCR regulates 3-phase AC power and feeds to the high voltage transformer. Two different types of the transformer configurations namely ${\Delta}-{\Delta}$ and ${\Delta}-Y$, are alternatively installed to 11 modulator units for the suppression of harmonic noises. RC filters and reactors are also installed. Currently, approximately 110-kW of average AC power per unit is consumed at the normal operation level of the modulator with 30pps. This paper presents the operational characteristics of the high power pulse modulator, especially the experimental results of the AC line harmonic components generated by the operation of the high power pulse modulator to suppress the switching noises from the SCR and rectifying diode arrays.

  • PDF

Study On the Pulse Power Supply using Inverter Power Supply for XFEL (XFEL용 인버터 고전압 전원공급장치를 이용한 펄스전원공급장치 연구)

  • Park, S.S.;Kim, S.H.;Kim, S.C.;Han, Y.J.;Hwang, J.Y.;Kim, H.G.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.198-200
    • /
    • 2005
  • The 2.5 GeV linac of the Pohang Light Source(PLS) is planed to be converted to a XFEL. The PAL XFEL requires a new 1.2-GeV linac that will be combined to the existing linac to increase a beam energy upto 3.7 GeV. The RF stability of 0.02 % is required for both RF phase and amplitude to get the XFEL output. This stability is mainly determined by a low level RF drive system and klystron-modulators. The stability level of the modulator has to be improved 10 times better to meet the pulse stability of 0.02 %. The regulation methods such as traditional de-Qing and precision inverter charging technology are reviewed to find out suitable upgrade scheme of the modulators.

  • PDF