• Title/Summary/Keyword: Kit preparation

Search Result 45, Processing Time 0.036 seconds

Establishment of Sample Preparation Method for PCR Detection of Clostridium perfringens from Agricultural Products (PCR 법을 이용한 농산물 중 Clostridium perfringens 검출을 위한 전처리법 확립)

  • Choi, Song-Yi;Seo, Min-Kyoung;Yoon, Jae-Hyun;Rajalingam, Nagendran;Hwang, Injun;Kim, Se-Ri
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.1
    • /
    • pp.93-99
    • /
    • 2021
  • This study was undertaken to compare the efficacy of different sample preparation (stomaching, pulsifying, and sonication) and DNA extraction methods (boiling and commercial kit) for detection of enterotoxin-producing Clostridium perfringens from produce by polymerase chain reaction (PCR). Each produce type was inoculated at concentrations of 102, 103, 104, 105, 106, and 107 spores/g. Produce inoculated with spores was treated with three sample preparation methods, and DNA was extracted by boiling method and a commercial kit, followed by PCR. The detection limit of stomached samples was lower than that of pummeled and sonicated samples by 10-100 times. Moreover, the DNA extraction efficiency of the commercial kit was found to be superior to that of boiling. In particular, the PCR efficiency of cherry tomato and perilla leaf samples was greatly affected by sample preparation and DNA extraction method. These data suggest that DNA extraction with a commercial kit after pulsification is an optimum sample preparation method for detection of C. perfringens by PCR.

Characteristics of flexible indium tin oxide electrode grown by continuous roll-to-roll sputtering process for flexible displays

  • Choi, Kwang-Hyuk;Cho, Sung-Woo;Jeong, Jin-A;Kim, Han-Ki
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.605-608
    • /
    • 2008
  • The preparation and characteristics of flexible indium tin oxide electrodes grown on polyethylene terephthalate (PET) substrates using a specially designed roll-to-roll sputtering system for use in flexible optoelectronics In spite of low a PET substrate temperature, we can obtain the flexible electrode with a sheet resistance of 47.4 ohm/square and an average optical transmittance of 83.46 % in the green region of 500~550 nm wavelength. Both x-ray diffraction (XRD) and field emission scanning electron microscopy (FESEM) analysis results showed that all flexible ITO electrodes grown on the PET substrate were an amorphous structure with a very smooth and featureless surface, regardless of the Ar/$O_2$ flow ratio due to the low substrate temperature, which is maintained by a cooling drum. In addition, the flexible ITO electrode grown on the Ar ion beam treated PET substrates showed more stable mechanical properties than the flexible ITO electrode grown on the wet cleaned PET substrate, due to an increased adhesion between the flexible ITO and the PET substrates.

  • PDF

Development of diagnostic kit(Test-MT) for the microplate latex agglutination test of toxoplasmosis in animal (Latex 응집반응을 이용한 동물의 톡소플라즈마병 진단용 kit 개발에 관한 연구)

  • Suh, Myung-deuk;Joo, Hoo-don;Maass, Daivd
    • Korean Journal of Veterinary Research
    • /
    • v.35 no.3
    • /
    • pp.583-593
    • /
    • 1995
  • The present study was conducted to develop a toxoplasma latex agglutination test antigen(Test-MT) and evaluate the toxoplasma latex agglutination(LA) test using a newly-made "Test-MT kit" by comparing with the Toxo-MT kit(Eiken chemical co, Tokyo). Also, the specifity and sensitivity test were made by comparing with IFA test and IgG-ELISA. Tachyzoite suspensions of Toxoplasma gondii(RH strain) were ultracentrifuged for 30min at $60,000{\times}g(4^{\circ}C)$ and the supernatant was used as a water-lysate antigen. Polystyrene latex particles of $1.0{\mu}m$ in diameter(Polyscience co) were used for the preparation of sensitized latex-antigen supension(Test-MT). The frequency distribution of LA titers in Test-MT showed two peaks at <1:32 and 1:128. The borderline titer for positive test in Test-MT was determined to be 1:64. But the frequency distribution of LA tites in Toxo-MT showed two peaks at <1:16 and 1:64. The positive borderline was determined to be 1:32. Agreement of reactions between Test-MT and Toxo-MT kit by LA test was shown 92.5% in bovine sera and 97.0% in swine sera, respectively. From the results obtained here it was determined that the sensitized latex-antigen, Test-MT kit, for the microtiter agglutination test prepared as same as by the procedure described in the previous paper(Suh and Lee, 1993) was useful as a highly specific, sensitive and stable immunotiteration reagent for serodiagnosis of toxoplasma infection in animal sera.

  • PDF

Comparison of Two Methods to Extract DNA from Formalin-Fixed, Paraffin-Embedded Tissues and their Impact on EGFR Mutation Detection in Non-small Cell Lung Carcinoma

  • Hu, Yu-Chang;Zhang, Qian;Huang, Yan-Hua;Liu, Yu-Fei;Chen, Hong-Lei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.6
    • /
    • pp.2733-2737
    • /
    • 2014
  • Objective: Molecular pathology tests are often carried for clinicopathological diagnosis and pathologists have established large collections of formalin-fixed, paraffin-embedded tissue (FFPE) banks. However, extraction of DNA from FFPE is a laborious and challenging for researchers in clinical laboratories. The aim of this study was to compare two widely used DNA extraction methods: using a QIAamp DNA FFPE kit from Qiagen and a Cobas Sample Preparation Kit from Roche, and evaluated the effect of the DNA quality on molecular diagnostics. Methods: DNA from FFPE non-small cell lung carcinoma tissues including biopsy and surgical specimens was extracted with both QIAamp DNA FFPE and Cobas Sample Preparation Kits and EGFR mutations of non-small cell lung carcinomas were detected by real-time quantitative PCR using the extracted DNA. Results and Conclusion: Our results showed that DNA extracted by QIAamp and Cobas methods were both suitable to detect downstream EGFR mutation in surgical specimens. Howover, Cobas method could yield more DNA from biopsy specimens, and gain much better EGFR mutation results.

Characterization of Titanium Diboride Composite Bipolar Plate for Polymer Electrolyte Membrane Fuel Cell (전해질 연료전지용 복합분리판의 특성에 미치는 TiB2 첨가효과)

  • Park, Jong-Moon;Sohn, Je-Ha;Park, Yong-Il;Lee, Dong-Gu;Oh, Myung-Hoon
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.27 no.4
    • /
    • pp.169-174
    • /
    • 2014
  • The effect of varying amounts of graphite and $TiB_2$ on the electrical conductivity of composite bipolar plates was systematically studied. In this study, Titanium diboride ($TiB_2$) which has a high electrical conductivity, was selected as a filler and a additive material instead of conventional graphite. For proper distribution of the filler and matrix materials, ball milling using alumina balls was conducted for 1h, and then the hot press method was applied for the preparation of composite samples. The results showed a rapid increase in the electrical conductivity of composite bipolar plates at the critical filler content. However, $TiB_2$ and graphite composite bipolar plates showed similar increases in the electrical conductivity even though $TiB_2$ has a higher electrical conductivity than graphite. In addition, it was also found that a small addition of $TiB_2$ to graphite filler could be very effective for increasing the electrical conductivity and flexural strength of the composite bipolar plate.

An Introduction of Urbani School Health Kit Developed by World Health Organization (세계보건기구의 Urbani School Health Kit 소개)

  • Nam, Eun-Woo;Chang, Chang-Gok;Park, Soon-Woo;Bonito, Sheila;Kim, Tae-Ho;Shin, Hai-Ri
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.12 no.1
    • /
    • pp.117-129
    • /
    • 2011
  • Objectives: The purpose of this study was to introduce of the Urbani School Health Kit (USHK) and to investigate the adaptability to Korean situation. Methods: The authors analyzed the contents of USHK developed by the health promotion team at the Western Pacific Regional Office of World Health Organization (WHO WPRO) in collaboration with health promotion experts at University of the Philippine Open University, and by observing health classes using the USHK in Angono elementary school in Manila, Philippines. Results: The following are the characteristics of USHK: 1) The USHK was composed of a teacher's guide and six books targeted to two groups of children: ages 5~6 years and 10~12, and an integrated package containing materials that can be used to support health education and health promotion activities in elementary schools. 2) The USHK could be integrated in the curriculum to reduce the burden of teacher's class preparation time and help teachers conveying clear and accurate health messages in their classes. 3) Several evaluation tools such as pre-test post-test quizzes, self-evaluation tools, observer checklists, and evaluation interview protocols were developed to monitor and evaluate whether USHK was useful, helpful, and appropriate. Conclusions: We found that USHK was a practical tool for supporting health promotion in elementary schools and could be applicable to health promoting schools in Korea if it were modified to address Korean school health problems.

  • PDF

Characteristics of phosphorescent OLED fabricated on IAZO anode grown by co-sputtering method (Co-sputtering 방법으로 제작한 IAZO 박막의 특성과 이를 이용하여 제작한 인광 OLED의 특성 분석)

  • Bae, Jung-Hyeok;Kim, Han-Ki
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.60-61
    • /
    • 2007
  • IAZO (indium aluminium zinc oxide) anode films were co-sputtered on glass substrate using a dual target DC magnetron sputtering system. For preparation of IATO films, at constant DC power of IZO (indium zinc oxide) target of 100 W, the DC power of AZO (Aluminum zinc oxide) target was varied from 0 to 100 W. To analyze electrical and optical properties of IAZO anode, Hall measurement examination and UV/V is spectrometer were performed, respectively. In addition, structure of IAZO anode film was examined by X-ray diffraction (XRD) method. Surface smoothness was investigated by Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM). From co-sputtered IAZO anode, good conductivity($2.32{\times}10^{-4}{\Omega}.cm$) and high transparency(approximately 80%) in the visible range were obtained even at low temperature deposition. Finally, J-V-L characteristics of phosphorescent OLED with IAZO anode were studied by Keithley 2400 and compared with phosphorescent OLED with conventional ITO anode.

  • PDF

PREPARATION OF N-(3-BROMO-2,4,6-TRIMETHYLACETANILIDE)IMINODIACETIC ACID AND ITS ${99M}^TC$-COMPLEX FOR HEPATOBILIARY IMAGING

  • CHOI OK-JA;HONG YOUNG-DON;GWON HUI-JEONG;CHOI SANG-MU;CHOI SUN-JU
    • Nuclear Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.391-394
    • /
    • 2005
  • N-(3-bromo-2,4,6-trimethylacetanilide)iminodiacetic acid (BrTIDA) was synthesized using nitrilotriacetic anhydride prepared in situ, and lyophilized vials were prepared which contained 20 mg of BrTIDA and 0.4 mg of $SnCl_2$. To evaluate the clinical efficacy of the in-house prepared lyophilized kit, a technetium-99m complex of BrTIDA was prepared; its in vivo pharmacokinetic behavior was evaluated via animal studies to assess the hepatocytic function and the functional status of the cystic duct and the gallbladder. Serial static image scans of rabbits and the biodistribution in mice injected with $^{99m}Tc-BrTIDA$ revealed that none of the tissues except for the hepatobiliary system showed radioactivity concentrations, and a rapid clearance from the organs was observed. In conclusion, a lyophilized kit and its prepared $^{99m}Tc-BrTIDA$ can be applied as a hepatobiliary imaging agent for the evaluation of the functional status of the hepatocytes and the patency of the biliary duct.

Development of Freeze-Dried DOTMP Kits for Labeling with 68Ga

  • Lim, Jae Cheong;Choi, Sang Mu;Cho, Eun Ha;Lee, So Young;Dho, So Hee;Kim, Soo Yong
    • Journal of Radiation Industry
    • /
    • v.9 no.2
    • /
    • pp.63-68
    • /
    • 2015
  • Lyophilized DOTMP kits were prepared using DOTMP, ammonium acetate, and ascorbic acid. The $^{68}Ga$-DOTMP was prepared by incubating the kit dissolved in 0.5 ml of concentrated $^{68}Ga$ using NaCl method and 0.5 ml of DDW, at $100^{\circ}C$ for 7 min. The labeling yield was evaluated by two solvent systems of TLC. 1 MBq of concentrated $^{68}Ga$ was labeled with $0.8{\mu}g$ of DOTMP by high radiolabeling yield (>98%), which was determined by two TLC methods. The composition of the prepared freeze-dried vial is $400{\mu}g$ of DOTMP, 19.27 mg of ammonium acetate and 17.62 mg of ascorbic acid. ~555 MBq of $^{68}Ga$-DOTMP was prepared with excellent radiochemical purity (>98%) and it was stable for 4 hr at room temperature. In conclusion, Freeze-dried DOTMP kits for the convenient preparation of $^{68}Ga$-DOTMP have been developed. Availability of this kit is expected to stimulate the widespread use of $^{68}Ga$-DOTMP in the fields of nuclear medicine.