• Title/Summary/Keyword: Kinetic Method

Search Result 1,066, Processing Time 0.035 seconds

Effects of Closed and Open Kinetic Chain Exercises on Lower Limb Muscle Activity in Chronic Stroke Patients (만성 뇌졸중 환자의 열린사슬운동과 닫힌사슬운동이 하지의 근활성도에 미치는 영향)

  • Kim, Jihwan;Jeong, Seonghwa;Lee, Geoncheol
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.2 no.4
    • /
    • pp.49-58
    • /
    • 2014
  • Purpose : The purpose of this study was to research the effects on resistance CKC & OCK exercise method on lower limb muscle activity, in chronic stroke patients. Method : In this study, 18 patients with stroke caused by hemorrhage or infarction were participated. resistance exercise method was conducted in tow different group : one is a close kinetic chain exercise(CKC) group and the other is an open kinetic chain exercise(OKC) group. CKC with physical therapy was applied to 9 patients, and OKC with physical therapy was applied to 9 patients. Under the researcher's guidance, exercise for CKC and OKC group carried out 3 times a week for 30 minutes during 4weeks. Result : There was significantly different for the vastus lateralis, tibialis anterior and gastrocnemius muscle activity within the intervention period both group. The vastus lateralis, tibialis anterior and gastrocnemius muscle activity was significantly increased within the CKC group. The vastus leteralis and tibialis anterior muscle activity was significantly increased within the OKC group. Conclusion : It was confirmed in this study that the CKC exercise was more effective than OKC exercise in improving lower limb muscle activity of chronic stroke patients. This study seggested that CKC may be suitable for individuals with a chronic stroke. furthermore study should be made a lot of researches regarding in other method and varying conditions for many hemiplegic patients.

Competitive Spectrophotometry for Microbial Dipeptide Transport Systems

  • Hwang, Se-Young;Ki, Mi-Ran;Cho, Suk-Young;Lim, Wang-Jin;Yoo, Ick-Dong
    • Journal of Microbiology and Biotechnology
    • /
    • v.6 no.2
    • /
    • pp.92-97
    • /
    • 1996
  • Portage kinetic constants of peptide transport can be measured by competitive spectrophotometry. The kinetic constants of L-Glu-L-Glu transport in Escherichia coli were ascertained using L-Phe-L-3-thia-Phe (PSP) as a detector. Since the production of thiophenol upon intracellular hydrolysis of PSP was competitively inhibited by L-Glu-L-Glu, it was able to compute the kinetic constants of L-Glu-L-Glu using this method. The resulted data were in agreement with the values obtained by the method of Michaelis-Menten kinetics. The potential of this method was examined against dipeptide transport systems in various microorganisms. These results strongly suggest that the overall properties of individual systems for dipeptide transports can be easily characterized by competitive spectrophotometry.

  • PDF

Effects of Visual Feedback Closed Kinetic Chain Exercise on the Lower Limb Muscles Activity and ankle Instability in Adult men with Chronic Ankle Instability (시각적 피드백을 이용한 닫힌 사슬 운동이 만성 발목 불안정성 성인남성의 하지 근활성도 및 발목 불안정성 지수에 미치는 영향)

  • Nam, Seung-Min;Lee, Do-Youn
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.1
    • /
    • pp.131-138
    • /
    • 2019
  • PURPOSE: This study examined the effects on muscle activation and ankle instability following sudden ankle inversion of the closed kinetic chain exercise using visual feedback to evaluate chronic ankle instability in adult males. METHODS: In this study, 28 subjects with chronic ankle instability were recruited and randomly divided into a closed kinetic chain exercise using a visual feedback group(n=13) and an open kinetic chain exercise group(n=15). Each group underwent 30 minutes of exercise three times a week for 8 weeks. The electromyographic(EMG) values of the rectus femoris, biceps femoris, tibialis anterior, peroneus longus, peroneus brevis, and lateral gastrocnemius muscles were measured to analyze muscle activity. The Cumberland ankle instability tool(CAIT) was used to measure ankle instability. RESULTS: Both groups showed improvements in tibialis anterior, peroneus longus and CAIT score(p<.05). In the experimental group, there were significant improvements in the rectus femoris, biceps femoris, and lateral gastrocnemius muscle activation(p<.05). CONCLUSION: The results suggest that closed kinetic chain exercise using visual feedback can be a useful treatment method for patients with chronic ankle instability.

An Advanced Kinetic Method for HO2·/O2-· Determination by Using Terephthalate in the Aqueous Solution

  • Kwon, Bum Gun;Kim, Jong-Oh;Kwon, Joong-Keun
    • Environmental Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.205-210
    • /
    • 2012
  • Hydroperoxyl radical/superoxide anion radical ($HO_2{\cdot}/O_2^-{\cdot}$, $pK_a$=4.8) as an intermediate is of considerable importance in oxidation processes. Hence, the method of detecting $HO_2{\cdot}/O_2^-{\cdot}$ with high sensitivity is necessary to be developed. To achieve this objective, this study newly employed terephthalate (TA) as a probe for the measurement of $HO_2{\cdot}/O_2^-{\cdot}$ in the kinetic method presented in our previous study. This method was based on the hydroxylation of TA to produce mainly hydroxyterephthalic acid or hydroxyterephthalate (OHTA), which was analyzed by fluorescence detection (${\lambda}_{ex}$=315nm, ${\lambda}_{ex}$=425nm). The life-time of $HO_2{\cdot}/O_2^-{\cdot}$ and its concentration formed from the photolysis technique of $H_2O_2$ were reported in this study. At range of pH 2-10, the life-time of $HO_2{\cdot}/O_2^-{\cdot}$ was 51-422 sec. In particular, an increase in the life-time with pH was observed. The sensitivities of the kinetic method by using TA were always higher with 1.7-2.5 times at pH 8.0 than those by using benzoic acid. From these results, this study can contribute to understanding the basic functions of $HO_2{\cdot}/O_2^-{\cdot}$ in oxidation processes.

Kinetic Modeling for Quality Prediction During Kimchi Fermentation

  • Chung, Hae-Kyung;Yeo, Kyung-Mok;Kim, Nyung-Hwan
    • Preventive Nutrition and Food Science
    • /
    • v.1 no.1
    • /
    • pp.41-45
    • /
    • 1996
  • This study was conducted to develop the fermentation kinetic model for the prediction of acidity and pH changes in Kimchi as a function of fermentation temperatures. The fitness of the model was evaluated using traditional two-step method and an alternative non-linear regression method. The changes in acidity and pH during fermentation followed the pattern of the first order reaction of a two-step method. As the fermentation temperature increased from 4$^{\circ}C$ to 28, the reaction rates of acidity and pH were increased 8.4 and 7.6 times, respectively. The activation energies of acidity and pH were 16.125 and 16.003kcal/mole. The average activation energies of acidity and pH using a non-linear method were 16.006 by the first order and 15.813 kcal/mole by the zero order, respectively. The non-linear procedure had better fitting 개 experimental data of the acidity and pH than two-step method. The shelf-lives based on the time to reach the 1.0% of acidity were 33.1day at 4$^{\circ}C$ and 2.8 day 28$^{\circ}C$.

  • PDF

Improvement of Coating Properties of Metal/diamond Composite Through Ni Coated Diamond in the Kinetic Spraying Process (저온 분사 공정에서 니켈이 코팅된 다이아몬드 적용을 통한 금속/다이아몬드 복합재료의 코팅성 향상)

  • Na, Hyun-Taek;Bae, Gyu-Yeol;Kang, Ki-Cheol;Kim, Hyung-Jun;Lee, Chang-Hee
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.6
    • /
    • pp.255-263
    • /
    • 2008
  • Generally, deposition mechanism of diamond particle is mainly embedding effect in the kinetic spray process. Accordingly, in spite of high cost, helium gas was employed as process gas to get high diamond fraction in the composite coating. In this study, the deposition behavior of bronze/diamond by kinetic spray process was compared using different process gas (helium and nitrogen). Bare (mean size of $5{\mu}m$, $20{\mu}m$) and nickel coated diamond (mean size of $26{\mu}m$) were deposited on Al 6061-T6 substrate with fixed process temperature and pressure. For comparison with experimental results, plastic deformation behavior of nickel layer was simulated by finite element analysis (using ABAQUS/Explicit 6.7-2). The size, broken ratio, and fraction of diamond in the composite coating were analyzed through scanning electron microscopy and image analysis method. The uniform distribution and deposition efficiency of diamond particles in the coating layer could be achieved by tailoring the physical properties of the feedstock.

Deposition Behavior and Microstructure of Fe-based Amorphous Alloy Fabricated by Vacuum Kinetic Spraying Process (진공 저온 분사 공정을 통해 형성된 Fe계 비정질 재료의 적층거동 및 미세구조 변화 관찰)

  • Kwon, Juhyuk;Park, Hyungkwon;Lee, Illjoo;Lee, Changhee
    • Korean Journal of Materials Research
    • /
    • v.24 no.1
    • /
    • pp.60-65
    • /
    • 2014
  • Fe-based amorphous coatings were fabricated on a soda-lime glass substrate by the vacuum kinetic spray method. The effect of the gas flow rate, which determines particle velocity, on the deposition behavior of the particle and microstructure of the resultant films was investigated. The as-fabricated microstructure of the film was studied by field emission scanning electron microscopy (FE-SEM) and high resolution transmission electron microscopy (HR-TEM). Although the activation energy for transformation from the amorphous phase to crystalline phase was lowered by severe plastic deformation and particle fracturing under a high strain rate, the crystalline phases could not be found in the coating layer. Incompletely fractured and small fragments 100~300 nm in size, which are smaller than initial feedstock material, were found on the coating surface and inside of the coating. Also, some pores and voids occurred between particle-particle interfaces. In the case of brittle Fe-based amorphous alloy, particles fail in fragmentation fracture mode through initiation and propagation of the numerous small cracks rather than shear fracture mode under compressive stress. It could be deduced that amorphous alloy underwent particle fracturing in a vacuum kinetic spray process. Also, it is considered that surface energy caused by the formation of new surfaces and friction energy contributed to the bonding of fragments.

A Study on the Identification and Improvement of Dynamic Characteristics of Large Structure by Component Mode Synthesis Method (부분 구조합성법을 이용한 대형구조물의 동특성 규명 및 개선에 관한 연구)

  • 오재응;이정환;임동규
    • Journal of KSNVE
    • /
    • v.4 no.3
    • /
    • pp.327-335
    • /
    • 1994
  • In this paper, to identify the dynamic characteristics of antenna system, the antenna is divided into 4 components and those were analyzed with a conventional FEM package MSC/NASTRAN. Using a Component Mode Synthesis Method, dynamic characteristics of total system is also identified. The Coherence of each component to total system is evaluated by using strain and kinetic component to total system is evaluated by using strain and kinetic energy. The improving strategy of dynamic characteristics is suggested by changing mass and stiffness of large coherence components.

  • PDF

A Short Kinetic Mechanism for Premixed Flames of Aromatic Compound : Benzene (방향족 화합물 화염의 축소 반응 메카니즘 개발 : 벤젠)

  • Lee, Ki Yong
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.161-164
    • /
    • 2015
  • A short kinetic mechanism for premixed benzene/air flames was developed with a reduction method of Simulation Error Minimization Connectivity Method(SEM-CM). It consisted of 38 species and 336 elementary reactions. Flame speeds were calculated and compared with those from full mechanisms and experiments of other researcher. Those comparisons are in good agreement between the full mechanism and the short mechanism at high pressure condition. In numerical work the running time with the short mechanism was over 10 times faster than one with the full mechanism.

  • PDF

Development of a Consistently Formulated General Order Nodal Method for Solving the Three-Dimensional Multi -Group Neutron Kinetic Equations

  • Kim, H.D.
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.137-141
    • /
    • 1996
  • A new general high order consistent nodal method for solving the 3-D multigroup neutron kinetic equations in (x-y-z) geometry has been derived by expending the flux in a multiple polynomial series for the space variables by without the quadratic fit approximations of the transverse leakage and for the time variable and using a weighted-integral technique. The derived equation set is consistent mathematically, and therefore, we can expect very accurate solutions and less computing time since we can use coarse meshes in time variable as well as in spatial variables and the solution would converge exactly in fine mesh limit.

  • PDF