• 제목/요약/키워드: Kim-test

검색결과 52,663건 처리시간 0.077초

Page Type Test for Ordered Alternatives on Multiple Ranked Set Samples.

  • Kim, Dong-Hee;Kim, Young-Cheol;Kim, Hyun-Gee
    • Communications for Statistical Applications and Methods
    • /
    • 제6권2호
    • /
    • pp.479-486
    • /
    • 1999
  • In this paper we propose the test statistic for ordered alternatives on multiple ranked set samples. Since the proposed test statistic is Page type its asymptotic properties are easily obtained. From the simulation works we calculate the power of test statistic($P_{RSS}$) under the underlying distributions such as uniform normal double exponential logistic and Cauchy distribution.

  • PDF

자기베어링 지지 모터-발전기 시스템 개발 (Development of An Active Magnetic Bearing-based Motor-Generator System)

  • 김종문;김춘경;김국헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.127-129
    • /
    • 1997
  • In this paper, an active magnetic bearing-based motor-generator(M-G) system is designed and controlled by using DSP devices. Several experiments including start-up test, impulse test, whirl test, and generator load test are conducted using digital PID algorithm and AC power of about 58Hz, 100V, 0.8A can be generated from the M-G set.

  • PDF

교면 덧씌우기 콘크리트의 인발부착강도(引拔附着强度) 시험법(試驗法) 제안(提案) (Proposal of Concrete Pull Off Bond Strength Measurement Method for Bridge Deck Overlay)

  • 김성환;김동호;김현오;이봉학
    • 산업기술연구
    • /
    • 제23권A호
    • /
    • pp.149-156
    • /
    • 2003
  • The development and maintenance of a sound bond are essential requirements of concrete repair and replacement. The bond property of a overlay to its substrate concrete during the lifetime is one of the most important performance requirements which should be quantified. A standard or a verified bond strength measurement method is required at field for screening, selecting materials and quality control for overlay or repair materials, but no test method has been adopted as a standard. In this study, a concrete pull off bond strength measurement method for field application is proposed and evaluated. This study compares the splitting tensile test, slant shear test, nipple pipe direct tensile test, flexural adhesion test, briquette tensile test, jumbo nail pull-out test and core pull-off test with their test procedures. From these comparison and investigation, core pull-off test is selected as a main topic of this study because of it's suitability for in situ testing, simplicities in field application and clearness at interface boundary condition. Thus, the proposed core pull off test is evaluated to be the most appropriate method for field application in a simple manner. The fracture surface and fracture mode could be easily determined by visual observation of failure surface of the field specimen. The core pull off test was found to be sensitive to surface condition and latex contents at latex modified concrete.

  • PDF

바인더 Stiffness와 혼합물의 변형강도 및 동적크리프 특성과의 상관성 분석을 통한 김테스트 적용성 고찰 (Correlation Analysis of Binder Stiffness with Deformation Strength and Dynamic Creep Property of Asphalt Mixtures for Evaluation of Kim Test Applicability)

  • 김광우;도영수;조문진
    • 한국도로학회논문집
    • /
    • 제7권4호
    • /
    • pp.91-102
    • /
    • 2005
  • 아스팔트 바인더 Stiffness와 혼합물의 변형강도 및 동적크리프 특성과의 상관성 분석을 토대로 혼합물의 소성변형 저항성 (내변형성) 추정을 위한 Kim test의 적용성을 고찰하였다. 본 연구는 골재 2종류, AC 60-80 및 이를 개질한 총 8종류의 바인더로 총 16가지 혼합물을 제조하였다. DSR로 각 바인더의 $G^*/sine\delta$를 측정하였으며 Kim test의 변형강도와 동적크리프 시험의 최종변위(FD)와 동적안정도(DS)를 각 혼합물로부터 측정하였다. 바인더의 $G^*/sine\delta$와 소성변형 관련 3가지 특성($S_D$. FD, DS)과의 상관성 분석 결과 $G^*/sine\delta$$S_D$와 상관성이 가장 높은 것으로 나타났다 $(R^2=0.88)$ 이는 혼합물에 내재해 있는 내변형성의 차이를 Kim test가 더 잘 구분해 낼 수 있음을 의미한다. 또한 DS와 $S_D$의 회귀분석 결과, $R^2$이 약 0.84 이상을 보여 변형강도는 동적크리프 시험의 동적안정도와 좋은 상관성을 가짐을 확인하였다. 따라서 본 연구를 통하여 아스팔트 혼합물의 내변형성 평가시 Kim test의 활용 가능성이 매우 높음을 확인하였다.

  • PDF

변형모드별 판재의 마찰특성 비교 (Comparison of Friction Coefficients of Sheet Materials in Various Deformation Modes)

  • 김영석;김기수
    • 소성∙가공
    • /
    • 제3권1호
    • /
    • pp.51-62
    • /
    • 1994
  • Cup drawing test and U-bending test were performed to evaluate the friction characteristics of sheet materials for the different deformation modes involved in stamping process. The coefficient of friction calculated from the each test was compared to that obtained from the draw bead friction test. It was clarified that the cup drawing test could be simply used for evaluating the friction characteristic of sheet material in deep drawing process with high contacting pressure. However the U-bending test is suitable to evaluate the frictional characteristic of sheet material in bending process with low contacting pressure.

  • PDF

Consistency of a Modified W Test for Exponentiality

  • Kim, Namhyun
    • Communications for Statistical Applications and Methods
    • /
    • 제9권3호
    • /
    • pp.629-637
    • /
    • 2002
  • Shapiro and Wilk(1972) developed a test for exponentiality with origin and scale unknown. The procedure consists of comparing the generalized least squares estimate of scale with the estimate of scale given by the sample variance. However the test based on the statistic is inconsistent Kim(2001a) proposed a modified Shapiro-Wilk's test statistic using the ratio of two asymptotically efficient estimators of scale. In this paper, we study the consistency of the proposed test.

저공해 연소기 시험기술 (Test Methods on Development of Low Emission Gas Turbine Combustor)

  • 김형모;최영호;김동식;박부민
    • 항공우주기술
    • /
    • 제6권1호
    • /
    • pp.29-34
    • /
    • 2007
  • On the stage of combustor development process, many aerodynamic and combustion characteristics are found out not by only ideal design concept but by only useful tests which are top confidentiality of technically advanced engine development companies, RR and GE, etc. In this study, test techniques of one of that company are analysed and described about some unique tests for test low emission combustors.

  • PDF

Reliability of Measured Popliteal Angle by Traditional and Stabilized Active-Knee-Extension Test

  • Kim, Min-Hee;Kim, Yong-Wook;Jung, Doh-Heon;Yi, Chung-Hwi
    • 한국전문물리치료학회지
    • /
    • 제16권4호
    • /
    • pp.1-7
    • /
    • 2009
  • The active-knee-extension (AKE) test has been used to measure hamstring muscle length. The traditional AKE test measures the popliteal angle to the point of resistance with a 90-degree flexion of the hip fixed by straps, while the stabilized AKE test measures the popliteal angle to the point of resistance with a 90-degree flexion of the hip stabilized using a pressure biofeedback unit providing lumbopelvic stabilization. The purpose of this study was to determine test-retest reliability of the traditional AKE test and stabilized AKE test. Twenty healthy adults participated in the study. The popliteal angles were measured with a digital inclinometer during each test. To assess the test-retest reliability between the 2 test sessions, intraclass correlation coefficients (ICCs) were calculated. The intrasubject coefficient of variation ($CV_{intra}$) was also calculated. To compare the traditional and stabilized AKE tests for changes in pressure, paired t-tests were applied. The results of this study were as follows: 1) ICCs(3,1) value for test-retest reliability was .96 in the traditional AKE test, and was .98 in the stabilized AKE test. 2) The maximal $CV_{intra}$ was 33.7% in the traditional AKE test and 15.7% in the stabilized AKE test. 3) Differences of $6.1{\pm}2.1$ mmHg in pressure were measured in the traditional AKE test, and differences of $1.2{\pm}1.0$ mmHg in pressure were measured in the stabilized AKE test. The results show the traditional and stabilized AKE test to be highly reliable, with test-retest reliability. However, the stabilized AKE test represented less variation and more stabilization than the traditional AKE test. Further study is needed to measure the inter-rater reliability of the stabilized AKE test for generalization and clinical application.

  • PDF