• Title/Summary/Keyword: Ki values

Search Result 3,154, Processing Time 0.037 seconds

Ki-67 Labeling Indices in 'Classic' versus 'Blastoid' Mantle Cell Lymphomas - Proposed Cutoff Values for Routine Diagnostic Workup

  • Pervez, Shahid;Haroon, Saroona;Awan, Dreema
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.15
    • /
    • pp.6591-6594
    • /
    • 2015
  • Background: Mantle-cell lymphoma (MCL) is a unique entity of peripheral B-cell lymphoma that has a discrete morphologic, immunologic, and genetic phenotype, with more common 'classic' and less frequent 'blastoid' and 'pleomorphic' variants, associated with an aggressive clinical course. The aim of this study was to analyze proliferation (Ki-67) indices of 'classic' (c-MCL) and 'blastoid' (b-MCL) variants of a cohort of MCL and to suggest cut off values for the Ki-67 proliferation index in these two subsets. Materials and Methods: MCL cases diagnosed over $4{\frac{1}{2}}$ years at Section of Histopathology, Department of Pathology and Laboratory Medicine, Aga Khan University Hospital, Karachi were retrieved and reviewed. Ki-67 labelling was scored and analysed. Results: A total of 90 of cases of MCL were scrutinized. Mean age ${\pm}SD$ was $60.2{\pm}12.5$ years and the male to female ratio was 4:1, with 67 (75%) cases of c-MCL and 23 (25%) cases of b-MCL. Most samples were lymph node biopsies (n=68), whereas the remainder were from various extranodal sites The mean Ki-67 proliferation index was $29.5%{\pm}14.4%$ in classic variants and $64.4{\pm}15.2%$ for the blastoid variant, the difference being statistically significant (p = 0.029). Conclusions: It was concluded that differential cut-off values of Ki-67 labeling may be used in more objective way to reliably classify MCL into classic or blastoid variants by diagnostic pathologists. We propose a < 40 proliferative index to be suggestive of c-MCL and one of > 50 for the blastoid variant.

Behaviour of Acid-Base Indicators in the Aqueous Organic Solutions. (수-유기용매혼합용매중의 산-염기지원약에 관한 연구)

  • 용군호
    • YAKHAK HOEJI
    • /
    • v.19 no.1
    • /
    • pp.30-35
    • /
    • 1975
  • pKi values and sensitivity of acid-base indicators in the mixed solvent systems of water-alcohols and water-acetone at differential pH and in concentration media were determined by spectrophotometric method. When the concentration of the organic solvents were increased, the pKi values of sulfophthalein indicators, thymol blue and bromcresol purple, became larger whereas those of an axo indicator, methyl yellow, became smaller nad the pH values of the equivalent points of acids became smaller and the pH values of the equivalent points of acids became higher than those in the aqueous solution. potassium bicarbonate, a standard compound used in the organic solvent systems without a prerequisite procedure of expelling carbon dioxide by boiling.

  • PDF

Establishment of Quality Evaluation Sensor for Pork Fillets Freshness during Storage based on Ki value Analysis (Ki value 분석을 활용한 보관 중 돼지고기 안심의 신선도 품질평가 센서 구축)

  • Belal, Shah Ahmed;Poaty Ditengou, Junior Isaac Celestin;Choe, Ho-Sung;Shim, Kwan-Seob
    • Korean Journal of Organic Agriculture
    • /
    • v.30 no.2
    • /
    • pp.291-302
    • /
    • 2022
  • Food safety is a fundamental requirement for consumers. Therefore, this study was aimed to determine the freshness of pork fillets based on freshness index (Ki value) analysis during storage. This study obtained a total of 24 pork fillets. This study was divided into 4℃ and -20℃ temperatures. Again, each temperature was divided into 4 different groups based on storage durations (15d). Each group was obtained in triplicate. The level of malondialdehyde (MDA) value was significantly increased at 4℃ than the -20℃ storage with the duration of storage days. The levels of inosine-5'-phosphate (IMP) in pork fillets were significantly decreased at 4℃ and -20℃. Hypoxanthine (Hx) levels were significantly increased at 15 days than those at 0 days during storage at both temperatures (4℃ and -20℃). Subsequent freezing increased more inosine levels at -20℃ than storage at 4℃. The Ki values were increased during storage days at both temperatures, although after 15d storage, its values at 4℃ were significantly higher than those at -20℃. These results demonstrated that storage period and temperature might affect the freshness of pork fillets via lipid oxidation and nucleotide degradation. This study suggested that the Ki value will be the crucial indicator of measurement of freshness of stored pork fillets.

Influence on PET Exam Caused by Density Differences of Barium-sulfate Contrast Media (Barium 조영제의 농도 차이가 PET 검사에 미치는 영향)

  • Choi, Woo-Joon;Shin, Sang-Ki;Nam, Ki-Pyo;Park, Soon-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.27-32
    • /
    • 2008
  • Purpose: The evaluation of SUV (Standardized Uptake Values) for quantitative analysis in PET exam is the most significant. In PET exam, we make attenuation correction images by using $^{68}Ge$, $^{137}Cs$ or CT data. At this time, a distorted attenuation map affects quantitative analysis. After the exam using barium-sulfate and high density of barium contrast make attenuation map distorted. And then it brings bed influences on SUV. The aim of this study is to verify the relationship between high density barium-sulfate and SUV in PET exam. Materials and Methods By using $^{18}F$-FDG, we made barium-sulfate powder, density of 0, 1.5, 3, 5, 10 and 15% respectively and acquired PET and PET/CT images per each density. And we examined SUV variations from PET and PET/CT images according to differences of barium's density. Moreover, we finally calculated SUV causing variations in HU (Hounsfield Units) values to justify whether the differences of barium density bring any changes in PET/CT exam. Results: From PET images acquired from transmission scan with $^{68}Ge$, we got SUV figures from 6.46 to 6.8 in barium density between 0 to 15 percent. On the other hand, In PET images acquired from Tx scan that using CT, SUV was 6.77 to 23.73, derived from the same barium density. And CT HU values range from 29 to 2004. Conclusion: PET images from Tx data using $^{68}Ge$ weren't affected by barium density and had no differences in SUV. But in the PET/CT images using CT Tx data, there's considerable variations in HU and SUV values according to a difference of barium density in HU values. To perform a precise examination, barium sulfate should be removed from a human body before performing a PET exam.

  • PDF

Characteristics of Flow-induced Vibration for CE Type Steam Generator Tube with Various Column and Row Number (CE형 증기발생기 전열관의 행열 변화에 따른 유체유발진동 특성)

  • Ryu, Ki-Wahn;Cho, Bong-Ho;Park, Chi-Yong;Park, Su-Ki
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.927-932
    • /
    • 2002
  • The stability ratio and vibrational amplitude of each tube inside a steam generator have different values. We estimate the characteristics of flow-induced vibration for CE type steam generator with various column and row number of the tube. To obtain the thermal-hydraulic data and stability ratio we use the ATHOS3-MODI and PIAT-FEI/TE code respectively. It turns out that the steam generator has a bounded central zone with the distributed values of the stability ratio and the vibrational amplitude, and those values across the zone boundary become decreased.

  • PDF

Steering Control Algorithm of a Locomotion Robot Using a Quaternion with Spherical Cubic Interpolation (ICCAS 2005)

  • Chung, Won-Jee;Kim, Ki-Jung;Seo, Young-Kyo;Lee, Ki-Sang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.658-663
    • /
    • 2005
  • This paper presents the steering control algorithm of a locomotion robot using a quaternion. The locomotion robot is to be moved on an irregular floor that can inevitably result in the errors of both position and orientation. Especially the orientation error should be compensated every work in order to adjust the misaligned values of current orientation to those commanded values. In this paper, we propose a new steering control algorithm between the two values by using a quaternion with spherical cubic interpolation. The proposed algorithm is shown to be effective in terms of vibration when compared to a conventional simple compensation without interpolation, by using $MATLAB^{(R)}$ and $VisualNastran4D^{(R)}$.

  • PDF

Characteristics of Flow-induced Vibration for CE Type Steam Generator Tube with Various Column and Row Number (CE형 증기발생기 튜브의 행열 변화에 따른 유체유발진동 특성)

  • Ryu, Ki-Wahn;Cho, Bong-Ho;Park, Chi-Yong;Park, Su-Ki
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.390.2-390
    • /
    • 2002
  • The stability ratio and vibrational amplitude of each tube inside a steam generator have different values. We estimate the characteristics of flow-induced vibration for CE type steam generator with various column and row number of the tube. To obtain the thermal-hydraulic data and stability ratio we use the ATHOS3 and PIAT-FEI/TE code respectively. It turns out that the steam generator has a bounded central zone which the distributed values of the stability ratio and the vibrational amplitude, and those values across the zone boundary become decreased.

  • PDF

Characteristics of Opioid k-Receptors in Rat and Guinea Pig Cortex (백서와 기니픽의 대뇌피질에서 Opioid Kappa 수용체의 특성에 관한 연구)

  • Kim, Kee-Won;Rho, Hye-Won;Kim, Hyoung-Il;Eun, Jae-Soon;Soh, Soo-Mi;Cho, Kyu-Park
    • The Korean Journal of Pharmacology
    • /
    • v.30 no.2
    • /
    • pp.153-165
    • /
    • 1994
  • In this study, we tested the influences of several ${\kappa}$ opioid ligands on the $[^3H]diprenorphine$ binding in rat and guinea pig cortex membrane preparations. Using paradigm to block ${\mu}\;and\;{\delta}$ opioid receptors with $DAMGO(1{\mu}M)$ and $DPDPE(1{\mu}M)$, $[^3H]diprenorphine$ labeled ${\kappa}$ sites. Competition analysis in both rat and guinea pig cortex has shown a single population of $[^3H]diprenorphine$ binding site with different Kd values, respectively. There is a significant difference in Ki values of (-) WIN44441 and (+)WIN44441 in both rat and guinea pig cortex. Bremazocine, (-)ethylketocyclazocine, (-)cyclazocine, nor-binaltorphimine effectively inhibited the $[^3H]diprenorphine$ binding with different Ki values in rat and guinea pig cortex. U-69,593, U-50,488H and dynorphine-A (1-8) did not inhibit the $[^3H]diprenorphine$ binding in rat but in guinea pig cortex. Nor-binaltorphimine was a ligand discriminate the ${\kappa}_1$, and ${\kappa}_2$ receptor most effectively. We, also, examined the influence of Na ion and $GTP{\gamma}S$, a nonhydrolyzable guanine nucleotide analog, on the inhibition of $[^3H]diprenorphine$ binding by diprenorphine, (-)ethyl-ketocyclazocine, U-69,593 and bremazocine. By the replacement of NaCl with N-methy-D-glucamine or addition of $GTP{\gamma}S$, Ki values of diprenorpnine were not changed and that of ethylketocyclazocine were changed significantly in both rat and guinea pig cortex. The Ki value of bremazocine was decreased by removal of Na ion, and increased by $GTP{\gamma}S$, however, was not changed by any one of either. These results suggest that there are 2 kinds of subtypes of ${\kappa}$ opioid receptor, ${\kappa}_1$, and ${\kappa}_2$, showing different Ki values for various ${\kappa}$ opioid ligands, also, bremazocine possess the antagonistic property at ${\kappa}_2$ site which is dominant subtype of K receptor in rat cortex.

  • PDF

Development of Software for Coarse Classifying

  • Jung, Ki-Mun;Kim, Myung-Cheol;Yum, Joon-Keun
    • Journal of the Korean Data and Information Science Society
    • /
    • v.17 no.4
    • /
    • pp.1085-1090
    • /
    • 2006
  • In general, the coarse classifying procedure splits the values of a continuous characteristic into bands and the values of a discrete characteristic into groups of values. Coarse classifying improves the robustness of the credit scoring system but it is complicate and troublesome procedure. Thus, in this paper, we develop a software for coarse classifying by using Visual Basic Language. By using the developed software, we can find the best split easily. Also, this software will help learners to study credit scoring.

  • PDF

Analysis of the Normalized Site Attenuation Using the Moment Method (정규화 시험장감쇠량의 모멘트 법 해석)

  • Ki Chai Kim
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.11
    • /
    • pp.48-57
    • /
    • 1993
  • The ANSI recently adopted normalized site attenuation(NSA) as a validation procedure of open area test sites. In this paper, the theoretical NSA values specified in the truth vlues of NSA were calculated for an ideal test site when tuned dipoles are used. A method of moments technique is employed to evaluate these NSA values. The calculated NSA values are more accurate than that of the ANSI.

  • PDF