• 제목/요약/키워드: Kappa statistics

검색결과 107건 처리시간 0.02초

A Study on the Least Squared Estimator of Autoregressive Models when Consecutive Missing Observations Exist

  • Ryu, Gui-Yeol
    • Communications for Statistical Applications and Methods
    • /
    • 제3권3호
    • /
    • pp.59-74
    • /
    • 1996
  • The properties of the residuals are investigated when K-consecutive observations are interpolated. The central limit theorem is also proved for the LSE for autoregressive parameters when $\kappa4--consecutive observations are contaminated. The performance of the interpolated LSE in small samples is investigated by simulation. And the interpolated with the Yule-Walker type estimator.

  • PDF

척수손상환자에서 보행 기능 평가도구인 WISCI II의 타당도와 신뢰도 (Validity and Reliability on the Walking Index for Spinal Cord Injury in the walking assessment of the SCI patient)

  • 이형수;정찬주;양회송;신영일
    • The Journal of Korean Physical Therapy
    • /
    • 제16권3호
    • /
    • pp.142-151
    • /
    • 2004
  • The purpose of this study was to determine the validity and the reliability of the WISCI II to ascertain its value in the walking function evaluation of spinal cord injury patient. The WISCI II consists of 20 variables with a total valus ranging from 6 to 20 score. A group of 23 spinal cord injury patient were included in this study. To determine the validity, kappa statistics between the WISCI II and SCIM II were measured. The result of this study are as follows: 1) In the validity study, the kappa statistics between the WISCI II and SCIM II were 0.79 and 0.84 for an initial total score and a discharge total score respectively, indicating a reasonable agreement between the two test. 2) In the reliability study, the Cronbach's alpha coefficient was 0.83 and 0.95 for total score indicating a good internal consistency. The finding suggest that the WISCI II demonstrated an acceptable validity and reliabilit for the evaluation of walking function capacity of spinal cord injury patient in clinical practice.

  • PDF

Reliability of cone-beam computed tomography for temporomandibular joint analysis

  • Gorucu-Coskuner, Hande;Atik, Ezgi;El, Hakan
    • 대한치과교정학회지
    • /
    • 제49권2호
    • /
    • pp.81-88
    • /
    • 2019
  • Objective: The aim was to assess the intraobserver and interobserver reliabilities of temporomandibular joint linear measurements and condylar shape classifications performed with cone-beam computed tomography (CBCT). Methods: CBCT images of 30 patients were measured at two different time points by two orthodontists using the Dolphin 3D program (n = 60). Anterior, posterior, and superior joint space measurements and sagittal joint morphology classification in the sagittal view and medial and lateral joint space and mediolateral width measurements and coronal joint morphology classification in the coronal view were recorded. Intraclass-interclass correlation coefficients (ICC) and kappa statistics were used to assess intraobserver and interobserver reliability for the measurements and morphology classifications, respectively. Results: The ICC values were good for measurements of the posterior joint space by observer I and for measurements of the posterior, medial, and lateral joint spaces by observer II, while the other intraobserver measurements were excellent. Only the mediolateral width measurements showed excellent interobserver ICC values, while the other measurements showed good interobserver ICC values. Intraobserver agreement for the sagittal morphology classifications was moderate (${\kappa}=0.479$) and almost perfect (${\kappa}=0.858$) for observers I and II, respectively, while the corresponding agreement for the coronal morphology classifications was substantial for both observers. The interobserver agreement values for sagittal and coronal morphology classifications were slight (${\kappa}=0.181$) and fair (${\kappa}=0.265$), respectively. Conclusions: Linear temporomandibular joint measurements were reproducible and reliable in both intraobserver and interobserver evaluations. However, interobserver agreement for assessments of condylar shape was low.

모의 실험을 이용한 여러 합치도들의 비교 (A simulation study of rater agreement measures)

  • 한경도;박용규
    • Journal of the Korean Data and Information Science Society
    • /
    • 제23권1호
    • /
    • pp.25-37
    • /
    • 2012
  • 두 평정자간 평가의 일치정도를 나타내는 합치도로 Cohen (1960)의 ${\pi}$, Scott (1955)의 H, 박미희와 박용규 (2007)의 등 많은 통계량이 제안되어왔다. 모의실험을 통하여 균형적 주변분포에서의 명목형과 순서형 합치도, 두 가지 역설이 발생하는 불균형 주변분포에서의 명목형 합치도들의 편의, 표준오차, 평균오차제곱 분산, 변이계수를 비교한 결과, 모든 경우에서 AC1과 H의 표준오차와 변이계수가 가장 작게 나타났다.

VARIOUS COMPACT-TYPE PROPERTIES BETWEEN ω-BOUNDEDNESS AND PSEUDOCOMPACTNESS

  • CHO, MYUNG HYUN;KIM, JUN-HUI;SEO, HYO SUN
    • 호남수학학술지
    • /
    • 제26권2호
    • /
    • pp.209-218
    • /
    • 2004
  • On the analogy of total countable compactness, we study interesting subfamilies in the class of pseudocompact spaces. We show relationships between totally pseudocompact spaces, sequentially pseudocompact spaces, and DFCC spaces. We also prove relationships among densely ${\xi}$-pseudocompact, ${\xi}$-pseudocompact, and countably pracompact spaces. As a productive result on countably pracompact spaces, we will prove that if X is a countably pracompact space and Y is a countably pracompact ${\kappa}$-space, then $X{\times}Y$ is count ably pracompact.

  • PDF

ON CONVERGENCE OF SERIES OF INDEPENDENTS RANDOM VARIABLES

  • Sung, Soo-Hak;Volodin, Andrei-I.
    • 대한수학회보
    • /
    • 제38권4호
    • /
    • pp.763-772
    • /
    • 2001
  • The rate of convergence for an almost surely convergent series $S_n={\Sigma^n}_{i-1}X_i$ of independent random variables is studied in this paper. More specifically, when S$_{n}$ converges almost surely to a random variable S, the tail series $T_n{\equiv}$ S - S_{n-1} = {\Sigma^\infty}_{i-n} X_i$ is a well-defined sequence of random variables with T$_{n}$ $\rightarrow$ 0 almost surely. Conditions are provided so that for a given positive sequence {$b_n, n {\geq$ 1}, the limit law sup$_{\kappa}\geqn | T_{\kappa}|/b_n \rightarrow$ 0 holds. This result generalizes a result of Nam and Rosalsky [4].

  • PDF

INCOMPLETE EXTENDED HURWITZ-LERCH ZETA FUNCTIONS AND ASSOCIATED PROPERTIES

  • Parmar, Rakesh K.;Saxena, Ram K.
    • 대한수학회논문집
    • /
    • 제32권2호
    • /
    • pp.287-304
    • /
    • 2017
  • Motivated mainly by certain interesting recent extensions of the generalized hypergeometric function [Integral Transforms Spec. Funct. 23 (2012), 659-683] by means of the incomplete Pochhammer symbols $({\lambda};{\kappa})_{\nu}$ and $[{\lambda};{\kappa}]_{\nu}$, we first introduce incomplete Fox-Wright function. We then define the families of incomplete extended Hurwitz-Lerch Zeta function. We then systematically investigate several interesting properties of these incomplete extended Hurwitz-Lerch Zeta function which include various integral representations, summation formula, fractional derivative formula. We also consider an application to probability distributions and some special cases of our main results.

순서를 갖는 척도모수들의 사전정보 하에 k-모집단 와이블분포의 베이지안 모수추정 (Bayesian Estimation of k-Population Weibull Distribution Under Ordered Scale Parameters)

  • 손영숙;김성욱
    • 응용통계연구
    • /
    • 제16권2호
    • /
    • pp.273-282
    • /
    • 2003
  • 순서화된 척도모수들의 사전정보를 가지는 k-모집단 와이블분포의 모수추정을 위한 베이지안방법이 제시된다. 모수추정은 깁스샘플링에 의해서 이루어지며, 특히 깁스샘플러에서 형태모수의 조건부 사후분포는 로그-오목함수이므로 적응기각표집(Adaptive Rejection Sampling: ARS)방법에 의해 모수생성을 하였다. 논의된 모수추정법을 전기 절연유체 고장시간자료에 적용하여 척도모수의 순서화정보를 반영한 경우와 그렇지 않은 경우를 비교하였다.

다기관 코호트 연구에서 경동맥 내막-중막 두께 측정의 측정자간 신뢰도 평가 (Inter-Rater Reliability of Carotid Intima-Media Thickness Measurements in a Multicenter Cohort Study)

  • Lee, Jung Hyun;Choi, Dong Phil;Shim, Jee-Seon;Kim, Dae Jung;Park, Sung-Ha;Kim, Hyeon Chang
    • Journal of health informatics and statistics
    • /
    • 제41권1호
    • /
    • pp.49-56
    • /
    • 2016
  • 목적: 경동맥 내막-중막 두께와 경동맥 경화반의 존재유무는 죽상동맥경화증의 임상 전단계를 나타내는 지표로 널리 사용되고 있다. 경동맥 내막-중막 두께를 측정할 때의 측정자 의존성 때문에, 다기관 연구에서는 경동맥 내막-중막 두께와 경화반 측정의 기관간 신뢰도를 확인하는 것이 중요하다. 이 연구의 목적은 심뇌혈관 및 대사질환원인 연구센터에 속해 있는 세 임상기관 사이의 경동맥 내막-중막 두께와 경화반 측정의 측정자간 신뢰도를 평가하는 것이다. 방법: 심뇌혈관 질환 과거력이 없는 사람 20명이 2014-2015년 사이에 이 연구에 참여하였고(연령 37-64세), 미리 정해진 프로토콜에 따라 연구참여자의 좌, 우 경동맥을 세 임상기관에서 반복적으로 측정하였다. 총 경동맥의 원위부에서 측정한 경동맥 내막-중막 두께의 최대값과 평균값을 기록하였다. 경동맥에서의 경화반 존재유무는 측정자에 의해 확인되었다. 경동맥 내막-중막 두께와 경화반 존재유무의 신뢰도를 급내상관계수와 카파 통계량을 통해 각각 평가하였다. 결과: 계산된 급내상관계수는 최대 경동맥 내막-중막 두께를 평가하였을 때 0.647이었고 (95% CI: 0.487-0.779), 평균 경동맥 내막-중막 두께를 평가하였을 때 0.758 (95% CI: 0.632-0.854) 이었다. Bland Altman plot에서, 관측치의 대부분은 평균의 차이에서 ${\pm}1.96$ 표준편차 사이에 분포하였다. 각 기관 사이의 경화반 존재유무에 대한 카파 통계량은 0.304 (기관 1과 2), 0.507 (기관 1과 3), 0.606 (기관 2와 3)이었다. 전반적인 일치를 평가하는 Fleiss카파값은 0.445였다. 결론: 세 임상기관 사이의 경동맥 내막-중막 두께의 측정자간 신뢰도는 훌륭하였으며, 경화반 존재유무에 대한 신뢰도는 적정하였다.

사상체질 진단요소들 간의 일치도 분석연구 (The research on agreement statistics analysis between factors of diagnosis)

  • 장은수;김호석;이시우;김종열
    • 한국한의학연구원논문집
    • /
    • 제12권2호통권17호
    • /
    • pp.103-113
    • /
    • 2006
  • Objectives we intended to know how much did it relate with the results between the instruments of diagnosis by using methods of three factors - QSCCII, PSSC(Phonetic System for Sasang Constitution)-2004, and body measurement which are usually used in diagnosing the Sasang Constitution in clinics Methods We diagnosed Sasang constitution through QSCCII, PSSC(Phonetic System for Sasang Constitution)-2004, Body measurement as a dignosis factors and we used Kappa coefficient to estimate simularity between diagnosis factors, and SPSS 12.0K to analyze data Results and conchusions 1. The orders of agreement statistics are different in the currency of Sasang Constitution diagnosis, Soeum-in was highest and Taeum-in lowest in the the fricency of Sasang Conctitution Diagnosis in the QSCCII, Soeum-in was highest Soyang-in lowest in the PSSC and Taeum-in highest, Soyang-in lowest in the body measurement so, we analogized incorrection in Sasang Constitution Diagnosis 2. Among 443 subjects, 156 (35.3%) had same dignosis in three Sasang Constitution factors. It means agreement statistics among factors of diagnosis are very low, so it is absolutely nessessary to research connection among those, especially Soyang-in part 3. Totally, it is not robust to apply these factors on Sasang Constitution diagnosis, especially agreement statistics between two kinds of Sasang Constitution diagnosis as $0.358{\sim}0.380$. However, we can have a possibility the more we use Sasang Constitution dignosis factors, the higher the agreement statistics is, through the ascending of agreement statistics as $0.526{\sim}0.592$, among three kinds of Sasang Constitution diagnosis To evaluate accuracy of Sasang Constitution diagnosis, it is nessessary to collect data from the subjects who are dignosed through the evidences such as herb medicine, disease and normal symption observation, etc. Using these data, we have to evaluate correction of seperated Sasang Constitution diagnosis methods and to connect those.

  • PDF