• Title/Summary/Keyword: Kagome damper

Search Result 7, Processing Time 0.014 seconds

Seismic Performance Evaluation of R/C Frame Apartment Strengthened with Kagome Truss Damper External Connection Method by Pseudo Dynamic Test (유사동적실험에 의한 외부접합형 카고메 트러스 제진장치가 설치된 RC 라멘조 공동주택의 내진성능 평가)

  • Heur, Moo-Won;Chun, Young-Soo;Hwang, Jae-Seung;Lee, Kang-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.23-34
    • /
    • 2015
  • Recently a new damper system with Kogome truss structure was developed and its mechanical properties were verified based on the laboratory test. This paper presents a Kagome truss damper external connection method for seismic strengthening of RC frame structural system. The Kagome external connection method, proposed in this study, consisted of building structure, Kagome damper and support system. The method is capable of reducing earthquake energy on the basis of the dynamic interaction between external support and building structures using Kagome damper. The pseudo-dynamic test, designed using a existing RC frame apartment for pilot application of LH corporation, was carried out in order to verify the seismic strengthening effects of the proposed method in terms of the maximum load carrying capacity and response ductility. Test results revealed that the proposed Kagome damper method installed in RC frame enhanced conspicuously the strength and displacement capacities, and the method can resist markedly under the large scaled earthquake intensity level.

Vibration Control of the Framed Building Structures Using KGDS System with Isotropic Damping Devices (등방성 감쇠장치를 갖는 KGDS시스템을 활용한 라멘조 건물의 제진효과)

  • Hur, Moo-Won;Lee, Sang-Hyun;Chun, Young-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.2
    • /
    • pp.52-59
    • /
    • 2015
  • In this paper, the vibration control effect of the isotropic damping devices (so-called Kagome dampers) was investigated by applying the Kagome dampers to a 20-story frame structure apartment. A new Kagome Damper System (KGDS) composed of the dampers and supporting column was proposed and numerical analyses were performed to investigate the effects of stiffness ratio between controlled structure and supporting column, the damper size and the number of the dampers. The numerical analysis results of a structure with KGDS up to the third story showed that the stiffness ratio should be higher than 6.4 and the damper size be at least $700{\times}700mm$ to effectively reduce the base shear and the maximum drift of the uppermost story. When the KGDS was installed up to the fifth story, the stiffness ratio should be higher than 7.0 and damper size needs to be at least $500{\times}500mm$ for obtaining the target performance.

Seismic Behavior Evaluation of Embedded Kagome Damping Device (콘크리트에 매립된 카고메 감쇠시스템의 내진거동평가)

  • Hur, Moo-Won;Lee, Sang-Hyun;Kim, Jong-Ho;Hwang, Jae-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.2
    • /
    • pp.84-91
    • /
    • 2019
  • Recently, there has been a tendency to improve seismic performance of building structure by installing a steel hysteretic damping device which is economically efficient and easy to install and maintain. However, for a reinforced concrete building, a set of complicated connecting hardware and braces to fix the steel hysteretic damping device yields deteriorated reliability in damping performance. Therefore, this study presents a method of directly embedding a Kagome damper, which was investigated in previous researches, into a concrete structure without additional connecting hardware. Moreover, in this study, a series of experiments conducted to provide a basis of the Kagome damper by confirming the seismic behavior for various embedded lengths. As a result, in a group of the embedded length of $1.0l_d$, the dampers were pulled out, while concrete breakout occurs. In a group of $2.0l_d$, neither pull-out nor concrete breakout occurred, while the dampers show stable behavior. Moreover, the buried length of $2.0l_d$ has 1.3 times better energy dissipation capacity. The system presented in this study can reduce the cost and period for installing, omitting making additional hardware.

Inelastic Seismic Response Control of the RC Framed Apartment Building Structures Using Exterior-Installed Kagome Damping System (외부접합형 카고메 감쇠시스템을 사용한 철근콘크리트 라멘조 공동주택 비탄성 지진 응답 제어)

  • Hur, Moo-Won;Chun, Young-Soo;Lee, Sang-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.3
    • /
    • pp.58-65
    • /
    • 2016
  • Various passive energy dissipation systems have been proposed and widely applied to real building structures under seismic load due to their high energy-dissipation potential and low cost for installation and maintenance. This paper presents nonlinear dynamic analysis results of the effectiveness of exterior-installed Kagome damping system(EKDS) in passively reducing seismic response. Kagome damping system proposed by previous studies has isotropic and bi-linear hysteretic characteristics and the installation configuration is newly presented in this study. The 15 and 20 story RC framed apartment buildings are used for verifying the effectiveness of the EKDS. The stiffness ratio of the damper supporting column to the original building, the number of the dampers, and the installed stories were considered as design parameters. Numerical results demonstrated that the EKDS were very effective in reducing both the two horizontal directional seismic responses by just using smaller number of exterior-installed damping system when compared to the traditional one-directional inter-story installed damping systems.

Mitigating Seismic Response of the RC Framed Apartment Building Structures Using Stair-Installation Kagome Damping System (계단 설치형 카고메 감쇠시스템을 활용한 철근콘크리트 라멘조 공동주택의 지진응답 개선)

  • Hur, Moo-Won;Chun, Young-Soo;Lee, Sang-Hyun;Hwang, Jae-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.23-30
    • /
    • 2018
  • Recently, there are highly interests on structural damping to improve resistance of seismic and wind. It has been frequently used hysteresis damping devices made of steel because of economic efficiency, construction, and maintenance. This paper presents the effective reduction of seismic response by using Kagome damping system(SKDS) in rahmen system apartment building. The proposed system is designed to be activated by the relative displacement between the building and the stairs. It is performed nonlinear dynamic analysis to review the effects of earthquake response reduction for the 20-stories rahmen framed apartment building. In the analysis of the SKDS system, the reduction of maximum response displacement, maximum response acceleration and layer shear force are compared with the seismic design, and the result show that allowable story displacement is satisfied with Korean Building Code (KBC 2016).

Mitigating Seismic Response of RC Framed Apartment Building Using Isotropic Hysteretic Steel Dampers (등방성 이력형 강재댐퍼를 이용한 RC 라멘조 아파트건물의 지진응답 개선)

  • Chun, Young-Soo;Bang, Jong-Dae
    • Land and Housing Review
    • /
    • v.5 no.2
    • /
    • pp.107-114
    • /
    • 2014
  • Passive energy dissipation systems for seismic applications have been under development for a number of years with a rapid increase in implementations starting in the mid-1990s in many countries. A metallic hysteretic damper has most commonly been used for seismic protection of structures in domestic area because they present high energy-dissipation potential at relatively low cost and easy to install and maintain. This paper presents an analytical case study of the effectiveness of isotropic hysteretic metallic damper(IHMD) called Kagome as a passive dissipative device in reducing structural response during seismic excitation. An eighteen-story RC framed apartment building is studied with and without IHMD. Results demonstrate the feasibility of these techniques for seismic mitigation. The inclusion of supplemental passive energy dissipation devices in the form of IHMD proved to be a very effective method for significantly reducing the seismic response of the building investigated.

Vibration Control Effect of the Framed Building Structures according to the Stiffness Ratio of Exo-type Damping System and Damper Device Yield Ratio (Exo-type 감쇠시스템의 강성비와 감쇠장치의 항복비에 따른 라멘조 건물의 제진효과)

  • Hur, Moo-Won;Lee, Sang-Hyun;Chun, Young-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.5
    • /
    • pp.38-44
    • /
    • 2015
  • In this paper, the vibration control effect of the Exo-type damping system was investigated by applying the Kagome dampers to 15-story and 20-story frame structure apartment. A new Exo-type damping system composed of the dampers and supporting column was proposed in the previous work and numerical analysis were performed to investigate the effects of optimum stiffness ratio between controlled structure and supporting column, the size of damper and yield ratio of the damper. The numerical analysis results of a structure with Exo-type damping system up to the third story showed that the stiffness ratio should be higher than 7.0 and the damper device yield ratio be at least 8.0% ($V_{damper}/V_{base\;shear$) to effectively reduce the base shear and the maximum drift of the uppermost story. When the Exo-type damping system was installed up to the fifth story, the stiffness ratio should be higher than 2.5 and damper device yield ratio needs to be at least 3.5% ($V_{damper}/V_{base\;shear$) for obtaining the target performance.