Abstract
In this paper, the vibration control effect of the Exo-type damping system was investigated by applying the Kagome dampers to 15-story and 20-story frame structure apartment. A new Exo-type damping system composed of the dampers and supporting column was proposed in the previous work and numerical analysis were performed to investigate the effects of optimum stiffness ratio between controlled structure and supporting column, the size of damper and yield ratio of the damper. The numerical analysis results of a structure with Exo-type damping system up to the third story showed that the stiffness ratio should be higher than 7.0 and the damper device yield ratio be at least 8.0% ($V_{damper}/V_{base\;shear$) to effectively reduce the base shear and the maximum drift of the uppermost story. When the Exo-type damping system was installed up to the fifth story, the stiffness ratio should be higher than 2.5 and damper device yield ratio needs to be at least 3.5% ($V_{damper}/V_{base\;shear$) for obtaining the target performance.
Keywords
Isotropic damping divice; Stiffness ratio; Damper device yield ratio; Vibration control; Guidelines;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Hur, Moo-Won, Lee, Sang-Hyun, Chun, Young-Soo (2015) "Vibration Control of the Framed Building Structures Using KGDS System with Isotropic Damping Devices", Journal of the Korea Institute for Structural Maintenance and Inspection, Vol. 19, no. 2, 52-59.   DOI   ScienceOn
2 Architectural Institute of Korea (2009), Building code and Commentary, KBC Committee, pp.102-103.
3 ASCE (2010), ASCE/SEI7-10 Minimum Design Loads for Buildings and Other Structures, Reston: American Society of Civil Engineers, 179-197.
4 Chun, Y. S., Hur, M. W. (2014), Influence of the Beam -Column Stiffness ratio on Passive supplemental Damping, Journal of KSMI, 18(1), 700-702.
5 Hwang, J. S., Park, S. C., Kang, K. J. (2013), A Study on the Hysteresis properties and Mathematical Model of Kagome Truss Damper, Architectural Institute of Korea, 29(9), 21-29.
6 Oh, Sang-Hoon, Kim, Young-Ju, Tyu, Hong-Sik, Choi, Hong-Bae, Kang, Chang-Hoon (2005), "Hysteresis Behavior of Beam-to- Column Connections with Elasto -Plastic Hysteretic Dampers", Architectural Institute of Korea, vol. 25, No 1, pp.635-638.
7 Lee, H. H., Kim, S. I. (2010), Metalic Damper Shape and Cyclic Behavior for the Seismic Capacity Improvement of Building Structures, Journal of Korea institute for Structural Maintenance Inspection, 14(3), 123-130.
8 Hwang, Jae Seung, Park, Seong Cheol, Kang, Ki Ju, "A Study on the Hysteresis properties and Mathematical Model of Kagome Truss Damper", Architectural Institute of Korea, vol. 29, No 9, 2013, pp.21-29.
9 Lee, D. and Taylor, D.P. (2000), "Viscous Damper Development and future Trends", Structural Design Tall Building 10, May, pp. 311-320.
10 Ko, G. D., Joo, J. H., Hwang, J. S. Kang, K. J. (2010), "Application of Wire-woven Bulk Kagome as a Vibration Control Device for a Building Structure", International Conference on Sustainable Building Asia, pp. 293-298.