• Title/Summary/Keyword: KV 영상

Search Result 18, Processing Time 0.018 seconds

The effects of voltage of x-ray tube on fractal dimension and anisotropy of diagnostic image

  • Baik, Jee-Seon;Lee, Sam-Sun;Park, Kwan-Soo;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.37 no.4
    • /
    • pp.211-215
    • /
    • 2007
  • Purpose: The purpose of this study was to evaluate the effect of the kV on fractal dimension of trabecular bone in digital radiographs. Materials and Methods: 16 bone cores were obtained from patients who had taken partial resection of tibia due to accidents. Each bone core along with an aluminum step wedge was radiographed with an occlusal film at 0.08 sec and with the constant film-focus distance (32 cm). All radiographs were acquired at 60, 75, and 90 kV. A rectangular ROI was drawn at medial part, distal part, and the bone defect area of each bone core image according to each kV. The directional fractal dimension was measured using Fourier Transform spectrum, and the anisotropy was obtained using directional fractal dimension. The values were compared by the repeated measures ANOVA. Results : The fractal dimensions increased along with kV increase (p < 0.05). The anisotropy measurements did not show statistically significant difference according to kV change. The fractal dimensions of the bone defect areas of the bone cores have low values contrast to the non-defect areas of the bone cores. The anisotropy measurements of the bone defect areas were lower than those of the non-defect areas of the bone cores, but not statistically significant. Conclusion: Fractal analysis can notice a difference of a change of voltage of x-ray tube and bone defect or not. And anisotropy of a trabecular bone is coherent even with change of the voltage of x-ray tube or defecting off a part of bone.

  • PDF

The Comparison of Knee Joint Displaying between The Anteroposterior Weight Bearing View and the Metatarsophalangeal View with Osteoarthritis Patients (골관절염 환자의 촬영방법에 대한 고찰 : AP-WB(Weight-bearing AP), MTP(semiflexed) 촬영법의 비교 고찰을 중심으로)

  • Jeon, Ju-Seob;Park, Hwan-Sang;Moon, Il-Bong;Moon, Ju-Wan;Choi, Nam-Kil;Kim, Chang-Bok;Eun, Sung-Jong
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.97-103
    • /
    • 2005
  • Objective : The aim of this study was to compare the knee joint displaying between the anteroposterior weight bearing(AP-WB) View and the metatarsophalangeal(MTP) view for assessing joint space narrowing(JSN) and osteophytes in osteoarthritis patients. Subjects and Materials : Two hundreds of twenty patients(38 men) who came rheumatoid caused by knee pain, had both AP-WB and MTP views taken on a day. Radiographs were evaluated independently by 13 experienced observers(3 orthopedics surgeon, 2 rheumatogist, 3 radiologist, 5 radiological technologist) They assessed JSN and osteophytes using by PACS monitor JSN was scored by the optic evaluation to the nearest at the narrowest point in medial compartments of the tibiofemoral joint in both knees. Osteophytes were graded 0 to 3(bad 0, not bad 1, good 2 and very good 3) according to a standard atlas. All exam was using by Philips(Buckey Diagnostic-TH) X-ray material. Exposure condition was 60 kv, 8 mAs and 100 cm focus to film distance. Results : JSN was scored $1.32{\pm}0.050$ in AP-WB view, $2.51{\pm}0.046$ in MTP view. MTP view of JSN score is higher to AP-WB view significantly(p<0.05). Osteophytes scored $2.14{\pm}0.054$ in AP-WB view, $2.10{\pm}0.054$ in MTP view. There was no difference(p<0.05) between MTP view and AP-WB view in osteophytes. But MTP view was more reproducible than AP-WB view Conclusions : Joint space narrowing is most important factor to diagnosis with knee joint Osteoarthritis patients. This study was summarized as follows; In comparision of JSN, MTP view was more widely displayed than AP-WB view. In comparision of Osteophytes, there was no difference between MTP view and AP-WB view. It was concluded MTP view was more useful method to diagnosis of knee joint Osteoarthritis patients.

  • PDF

Abosrbed Dose Measurements and Phantom Image Ecaluation at Minimum CT Dose for Pediatric SPECT/CT Scan (소아 SPECT/CT 검사를 위한 최저조건에서의 피폭선량측정 및 팬텀의 영상평가)

  • Park, Chan Rok;Choi, Jin Wook;Cho, Seong Wook;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.82-88
    • /
    • 2014
  • Purpose: The purpose of study was to evaluate radiation dose for pediatric patients by changing tube voltage (kVp) and tube current (mA) at minimum conditions. By evaluating radiation dose, we want to provide dose reduction for pediatric patients and maintain good quality of SPECT/CT images. Materials and Methods: Discovery NM/CT 670 Scanne was used as SPECT/CT. Tube voltages are 80 and 100 kvP. Tube currents are 10, 15, 20, 25 mA. Using PMMA (Polymethyl methacrylate) Phantom, radiation dose which were calculated at center and peripheral dose and SNRD (Signal to Noise Ratio Dose) were evaluated. Using the CT performance phantom, spatial resolution was evaluated as the MTF (Modulation Transfer Function) graph. Jaszczak phantom was used for SPECT image evaluation by CNR (Contrast to Noise to Ratio). Results: Radiation dose using the PMMA phantom was higher peripheral dose than center dose about 7%. SNRD were 7.8, 8.2, 8.3, 8.8, 8.8, 9.9, 9.8, 9.6 for 80 kVp 10, 15, 20, 25 mA, 100 kVp 10, 15, 20, 25 mA. We can distinguish 35, 45, 70, 71, 52, 58, 90, 110 linepair for 80 kVp 10, 15, 20, 25 mA, 100 kVp 10, 15, 20, 25 mA at resolution with MTF. CNR of SPECT images using CT attenuation map were 57.8, 57.7, 57.1, 56.7, 56.6, 56.7, 56.7, 56.7% for 80 kVp 10, 15, 20, 25 mA, 100 kVp 10, 15, 20, 25 mA. Conclusion: In this study, radiation dose for pediatric patients showed decreased low dose condition. And SNRD value was similar in all condition. Resolution showed higher value at 100kVp than 80kVp. for CNR, there was no significant difference. we should take additional study to prove better quality and dose reduction.

  • PDF

Evaluation on Usefulness of Applying Body-fix to Liver Cancer Patient in Tomotherapy (간암환자의 토모치료시 Body-fix 사용유무에 따른 유용성 평가)

  • Oh, Byeong-Cheon;Choi, Tae-Gu;Kim, Gi-Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.11-18
    • /
    • 2010
  • Purpose: In every time radiation therapy set up errors occur because internal anatomical organs move due to breathing and change of patient's position. These errors may affect the change of dose distribution between target area and normal structure. This study investigates the usefulness of body-fix in clinical treatment. Materials and Methods: Among 55~60 aged male patients who has hepatocellular carcinoma in area of liver's couinaud classification, we chose 10 patients and divided two groups by using body-fix or not. When applying body-fix, we maintained a vacuum of 80 mbar pressure by using vacuum pump (Medical intelligence, Germany). Patients had free breathing with supine position. After working to fuse and consist MV-CT (megavoltage computed tomography) with KV-CT (kilovoltage computed tomography) obtained by 5 times treatments, we compared and analyzed set up errors occurred to (Right to Left, RL) of X axis, (Anterioposterio, AP) of Z axis, (Cranicoudal, CC) of Y axis. Results: Average Set up errors through image fusion showed that group A moved $0.3{\pm}1.1\;mm$ (Cranicoudal, CC), $-1.1{\pm}0.7\;mm$ (Right to Left, RL), $-0.2{\pm}0.7\;mm$ (Anterioposterio, AP) and group B moved $0.62{\pm}1.94\;mm$ (Cranicoudal, CC), $-3.62{\pm}1.5\;mm$ (Right to Left, RL), $-0.22{\pm}1.2\;mm$ (Anterioposterio, AP). Deviations of X, Y and Z axis directions by applying body-fix indicated that maximum X axis was 5.5 mm, Y axis was 19.8 mm and Z axis was 3.2 mm. In relation to analysis of error directions, consistency doesn't exist for every patient but by using body-fix showed that the result of stable aspect in spite of changes of everyday's patient position and breathing. Conclusion: Using body-fix for liver cancer patient is considered effectively for tomotherapy. Because deviations between group A and B exist but they were stable and regular.

  • PDF

An Assessment of the Radiation Dose from Radiography with the Change in Air Gap (공극(기극(氣隙)) 변화에 따른 방사선촬영 선량평가)

  • Ahn, Byeong Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.381-385
    • /
    • 2016
  • This study aims to propose a method for reducing radiation dose in high-voltage radiography using air gap technique while maintaining the same image quality as when using grids. For an experiment, air gaps were set at 10 cm, 15 cm, 20 cm, 25 cm, and 30 cm with a focus-receptor distance of 180 cm; with each air gap distance, tube current was set at 15 mAs, and tube voltage was set at 80 kVp, 85 kVp, 90 kVp, 95 kVp and 100 kVp. Then, radiographs were taken. In a situation of employing a conventional method of using grids, radiographs were taken at 15 mAs and 107 kVp with a focus-receptor distance of 180 cm. According to the results of the experiment, the surface radiation dose from radiography using grids was 0.130 R; the surface radiation dose at a 20cm air gap was 0.124 R; PSNR between these two images was 10.65 [dB]. In conclusion, the air gap distance, which could maintain the image quality similar to that of a case where scattered radiation was removed and grids were used with a small surface radiation dose, was 20 cm. The result of this study is thought to be used as an indicator to remove surface radiation dose in radiography using air gap.

A Study of Image Quality and Exposed Dose by Field Size Changing on CBCT (CBCT 촬영 시 조사야 조절에 따른 영상의 최적화 및 피폭선량에 관한 고찰)

  • Bang, Seung Jae;Kim, Young Yeon;Jeong, Il Seon;Kim, Jeong Soo;Kim, Young Gon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.175-180
    • /
    • 2013
  • Purpose: Modern radiation therapy technique such as IGRT has become a routine clinical practice on LINAC for decrease patient's set-up error. CBCT can be used to adjust patient set-up error and treat patient more accurately. The Purpose of this study is to evaluate field size of CBCT for improving Image quality and suggest reference date of CBCT field size. Materials and Methods: Image date were acquired using KV CBCT and Catphan phantom (Half fan and full fan mode were scanned from 2 ~16 cm, at intervals of 2 cm). Field size were categorized by Small field size (2 cm, 4 cm), Medium field size (8 cm, 10 cm), Large field size (more than 14 cm) and evaluate. To estimated the CTDi using CTDi phantom and Ion chamber. Results: CT number linearity of Small and Large field size are greater than Medium field size. Spatial resolution are not significantly different without Small field size. But half fan mode is more different than full fan mode. In full fan, except Medium field size, all field size exceed recommendation for HU uniformity. But half pan has stability for all field except Small field size. CTDi makes radical sign function graph in Medium field size. Conclusion: The worst result was given by Small field size for Image quality and practically. Medium field size can be useful to prevent patient from radiation exposure and give better Image quality. So this study recommends that Medium field size (8~10 cm) is more suitable for CBCT.

  • PDF

Experiences of the First 130 Patients in Gangnam Severance Hospital (강남세브란스병원 토모테라피를 이용한 치료환자의 130예 통계분석 및 경험)

  • Ha, Jin-Sook;Jeon, Mi-Jin;Kim, Sei-Joon;Kim, Jong-Dae;Shin, Dong-Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.45-53
    • /
    • 2008
  • Purpose: We are trying to analyze 130 patients' conditions by using our Helical Tomotherapy, which was installed in our center in Oct. 2007. We will be statistically approach this examination and analyze so that we will be able to figure out adaptive plans according to the change in place of the tumor, GTV (gross tumor volume), total amount of time it took, vector (${\upsilon}=\surd$x2+y2+z2) and the change in size of the tumor. Materials and Methods: Objectives were the patients who were medicated with Tomotherapy in our medical center since Oct. 2007 August 2008. The Average age of the patients were 53 years old (Minimum 25 years old, Maximum 83 years old). The parts of the body we operated were could be categorized as Head&neck (n=22), Chest (n=47), Abdomen (n=25), Pelvis (n=11), Bone (n=25). MVCT had acted on 2702 times, and also had acted on our adaptive plan toward patients who showed big difference in the size of tumor. Also, after equalizing our gained MVCT and kv-CT we checked up on the range of possible mistake, using x, y, z, roll and vector. We've also investigated on Set-up, MVCT, average time of operation and target volume. Results: Mean time on table was 22.8 minutes. Mean treatment time was 13.26 minutes. Mean correction (mm) was X=-0.7, Y=-1.4, Z=5.77, roll=0.29, vector=8.66 Head&neck patients had 2.96 mm less vector value in movement than patients of Chest, Abdomen, Bone. In increasing order, Head&neck, Bone, Abdomen, Chest, Pelvis showed the vector value in movement. Also, there were 27 patients for adaptive plan, 39 patients, who had long or multiple tumor. We could know that When medical treatment is one cure plan, it takes 32 minutes, and when medical treatment is two cure plan, it takes 40 minutes that one medical treatment takes 21 minutes, and the other medical treatment takes 19 minutes. Conclusion:With our basic tools, we could bring more accurate IMRT with MVCT. Also, through our daily image, we checked up on the change in tumor so that adaptive plan could work. It was made it possible to take the cure of long or multiple tumor, the cure in a nearby OAR, and the complicated cure that should make changes of gradient dose distribution.

  • PDF

Application of Radiological Study by Small Bowel Disease - Comparison of Diagnostic Results of Small Bowel Series and Abdominal Pelvic Computed Tomography - (소장 질환별 방사선학적 검사의 적용에 관한 연구 - 소장조영술과 복부골반전산화단층촬영의 결과 분석을 중심으로 -)

  • Lee, Hee-Jung;Son, Soon-Yong;Lee, Won-Hong
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.279-286
    • /
    • 2005
  • Purpose : There are two modalities, those are small bowel series(SBS) and abdominal pelvic computed tomography(CT), for diagnosis of small bowel disease. The aim of this study is to lend radiological technologists who are doing the two modalities assistance in the understanding characteristic of disease by comparing the two results. Meterials and method : 284 patients were examined the two SBS and abdominal pelvic CT together from 1999 to 2003. 250 ml $BaSO_4$ suspension 40 w/v% and 600ml carboxy methyl cellulose 0.5 w/v% were used for SBS. Abdominal Pelvic CT was examined in one hour before taking 450 ml $BaSO_4$ suspension 1.5 w/v%. The CT scan was done in 72 sec after 150 ml contrast media injection. the used protocol was helical mode 5:5 mm pitch 1.375:1, speed 27.50, exposure 120 kv, 240 mA, tube rotation time 0.5 sec. the statistic analysis was conducted with statistical program SPSS 10 version with frequency and crossing analysis. P-value less than 0.05 were considered significant. Results : In the results of SBS, normal findings were 131 patients(46.1%), inflammatory bowel disease(IBD) 64(22.9%), ischemia+ileocolitis+vasculitis 22(7.7%), Obstruction+stricture 21(7.7%) and Others 45(15.9%). In the results of abdominal pelvic CT, normal findings were 103 patients(36.3%), inflammatory bowel disease 65(22.9%), wall thickening+lymphadenopathy 42(14.8%), Fluid collection 17(6%), and Others 57case(20%). The same results of the two were 130patients(45.8%). 30patients(10.6%) of normal finding in SBS were diagnosed as wall thickening+lymphadenopathy and IBD in CT, and 15patients(5.3%) of normal finding in CT were diagnosed as ischemia+ileocolitis+vasculitis, mass and IBD in SBS(p<0.05). Transit time delay was diagnosed in 10patients(3.5%) on only SBS, wall thickening+lymphadenopathy was diagnosed in 20patients(7%) in only CT(p<0.05). Conclusion : We think that proper examination method will be selected in the small bowel disease, if we understand the characteristics of the disease and method.

  • PDF