• 제목/요약/키워드: KS 시험

검색결과 500건 처리시간 0.028초

Study on the unification between KS I ISO standard and official test method enacted by Korean Ministry of Environment - drinking water and indoor air quality - (환경오염공정시험기준과 KS ISO규격의 일원화에 관한 연구 - 먹는 물 및 실내공기질 -)

  • Lee, Jeong-Il;Lee, Ju-Hee;Lee, Jeong-Hee;Lee, Jun-Hee;Lee, Won-Seok;Kim, Ji-In;Kim, Bo-Kyung;Choi, Sung-Hun
    • Analytical Science and Technology
    • /
    • 제25권2호
    • /
    • pp.102-113
    • /
    • 2012
  • Our study researched on unification of KS I ISO standard harmonized with ISO and Official Test Method enacted by Korean Ministry of Environment-drinking water and indoor air quality. We reviewed KS methods related to drinking water and indoor air quality for about 23,000 KS methods. KS methods related environmental field are classified as KS I, total 635 methods and 583 KS I methods were harmonized with ISO. For Environmental Standard methods for drinking water, 100 methods were reviewed according to 232 KS methods related to ISO/ TC 147 "Water Quality". Environmental Standard methods for indoor air quality were reviewed according to 95 KS standard methods related to ISO/TC 146 "Air Quality". By reviews and comparison tests for unifiable ES for drinking water and indoor air quality with KS methods harmonized with ISO, it was evaluated that for 100 ES methods for drinking water, 23 ES methods were unification complete, 29 ES methods were unification possible, 12 ES methods were unification impossible, no corresponding methods were found in KS I ISO for 36 ES methods and for 17 ES methods for indoor air quality,1 ES methods were unification complete, 3 ES methods were unification possible, 3 ES methods were impossible, no corresponding methods were found in KS I ISO for 10 ES methods.

Material Properties of 400MPa Grade Hot Rolled H-beam(SHN400) for Building Structure (400MPa급 건축구조용 열간압연 H형강(SHN400)의 소재 특성)

  • Kim, Hee-Dong;Choi, Byoung-Jeong;Kim, Sang-Sub;Kim, Chul-Hwan;Oh, Young-Suk
    • Journal of Korean Society of Steel Construction
    • /
    • 제23권4호
    • /
    • pp.515-522
    • /
    • 2011
  • The purpose of this study was to evaluate the material characteristics of SHN400 steel, which is suitable as a steel material for building structures, using the experimental approach. For this purpose, the chemical composition test, tensile test, macro test, micro test, and charpy notch impact test were conducted with specimens taken from the highest, thickest, and commonly used H-beams for girder or beam members. Each test was conducted under the Korean Standard(KS) test conditions. All the test results satisfied the requirements of KS (KS D 3866) and the steel material for seismic design. The carbon equivalent value (Ceq), which is related to weldability, and the yield ratio, which is related to inelastic behavior, showed especially good results. Thus, SHN400 is definitely suitable as the steel material for building structures.

Welding Characteristics of 400MPa Grade Hot Rolled H-beam(SHN400) for Building Structure (400MPa급 건축구조용 열간압연 H형강(SHN400)의 용접특성)

  • Kim, Hee-Dong;Yang, Jae-Geun;Lee, Eun-Taik;Kim, Woo-Bum;Oh, Young-Suk
    • Journal of Korean Society of Steel Construction
    • /
    • 제24권1호
    • /
    • pp.129-136
    • /
    • 2012
  • This study seeks to evaluate the welding characteristics of SHN400 steel, which is suitable for the steel material used in building structures in KS. For this purpose, the Y-groove weld crack test and hardness, tensile, bending, cross tensile, and charpy V notch tests at the welding point were conducted with specimens taken from the highest, the thickest and the commonly used H-beams for girder or beam members. Each test was conducted under the KS test conditions. All tests results satisfied the requirements of KS and the welding requirements for the proper inelastic behavior of structure, indicating that SHN400 can be used for the building structure as a structural material.

Assessment of Fungal Growth Resistance in Silicone Sealants According to Test Methods (시험법에 따른 실리콘 실란트의 곰팡이 저항성 평가)

  • Ahn, Myung-Su;Choi, Sung-Hyun;Lee, Ki-Hyang;Nah, Changwoon
    • Journal of the Korea Institute of Building Construction
    • /
    • 제24권1호
    • /
    • pp.43-53
    • /
    • 2024
  • This research undertook the assessment of six types of silicone sealants prepared. Their resistance to fungi was evaluated according to ASTM G 21, LH specification(LHCS 41 40 12), and the newly instituted KS F ISO 21265 test methods. The findings showed that KS F ISO 21265 test method exhibited the superior discriminative capability in assessing fungal resistance when compared to ASTM G 21 and LH specification(LHCS 41 40 12) test methods. Additionally, it was confirmed that oxime curing sealants demonstrated higher fungal resistance than alkoxy curing sealants. Furthermore, The introduction of a condition to assess fungal resistance after 4 weeks of immersion at 50℃ in KS F ISO 21265 is expected to enable long-term fungal resistance evaluation of sealants.

Enhancement of Insecticidal Activity of the Acetamiprid Soluble Concentrate using a Photostabilizer (광안정제를 이용한 acetamiprid 액제의 살충효과 증진)

  • Kim, Hyeong-Min;Lee, Weon-Kee;Kim, Jong-Kwan;Seok, Chang-Su;Lee, Chang-Hyuk;Yu, Yong-Man;Hwang, In-Cheon
    • The Korean Journal of Pesticide Science
    • /
    • 제10권3호
    • /
    • pp.210-217
    • /
    • 2006
  • The study was carried out to select the effective adjuvant as a photostabilizer for acetamiprid 5% SL(soluble concentrate) and to find its optimum content by using chemical and biological methods. Adjuvants used for the study were KS1 and KS2. Photodegradation test, insecticidal efficacies and residual analysis for the study were investigated. Although photodegradation rate of acetamiprid SL was decreased by addition of KS1 and KS2, the difference between KS1 and KS2 was not significant. As KS2 showed better efficacies against the cotton aphid (Aphis gossypii) and higher amount of residue on pepper than KS1, KS2 was selected as a photostabilizer for acetamiprid SL. Acetamipid SL with KS2 showed lower photodegradation rate, better efficacies against the cotton aphid (Aphis gossypii) and higher amount of residue on pepper as content of KS2 in acetamiprid SL was decreased. Therefore, it was concluded that the optimum content of KS2 was 0.1%. These results have demonstrated that the selected adjuvant could be used to enhance insecticidal activity and reduce spay dose of insecticide by protecting its photodegradation.

Soil Mechanical Properties for Fill Slope of Forest Road in Mt. Gari (춘천(春川) 가리산(加里山) 지역(地域)의 임도(林道) 성토사면(盛土斜面)의 토질역학적(土質力學的) 특성(特性))

  • Cha, Du Song;Chun, Kun Woo;Ji, Byoung Yun;Oh, Jae Heun
    • Journal of Forest and Environmental Science
    • /
    • 제15권1호
    • /
    • pp.98-106
    • /
    • 1999
  • This study was carried out to analyze the mechanical properties of soil for counterplan of recovery construction and the slope stability on fill slope of Sang-gul forest road in Mt. Gari. To analyze the mechanical properties of apparent soil on fill slope in forest road, various soils such as soil, gravelly sandy soil, weathered rock were used as experimental sample in this study. In each experimental sample, particle size distribution test, liquid limit test, plastic limit test, and specific gravity test were carried by Korean industrial standards(KS F 2302, KS F 2303, KS F 2304, KS F 2306, KS F 2308). Through the results of soil particle size distribution analysis, soil moisture content analysis, and specific gravity analysis, soil texture, uniformity coefficient, curvature coefficient, dry density and specific gravity were able to be determined in sampling site. As a results in this study, soil was classified as SP, SW, GP by Unified Soil Classification Standard (USCS). specific gravity and dry unit weight of soil have the value range of 2.52~2.60 and 1.39~1.43, respectively. Also plastic index showed non plastic condition.

  • PDF

Quality Tests for the Knee-Orthosis Velcro and Locking System (무릎보조기 벨크로 및 잠금장치에 대한 품질시험 연구)

  • Jung, Se-Wook;Seo, Won-San;Cho, KiHun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제17권5호
    • /
    • pp.275-283
    • /
    • 2016
  • In this study, three knee-orthoses (dial lock type, medium size, right side) were used for a quality level test (static bending test and solidity test of the locking system) of the knee-orthosis locking system. In the static bending test, a smaller maximum load was observed in samples A and C compared to the reference standard value (KS P 8408 standard value: 1000 N, sample A: 865 N, sample C: 833 N). In addition, in the solidity test of the locking system, a smaller maximum load was observed in the all samples compared to the referenced standard value (KS P 8411 standard value: 200 N, sample A: 41 N, sample B: 97 N, sample C: 54 N). Korean industrial standards for knee-orthoses and systematic test methods are lacking. Therefore, a systematic management plan for knee-orthoses is required. The result of the current study showed that a systematic management plan for the knee-orthosis locking system is required. In particular, the development of a quantitative and objective test method is needed. The findings of the current study may be useful for monitoring the quality of the knee-orthosis locking system and may provide foundational information for the development of a quantitative and objective test method.

Opening Size Determination of Geotextiles Using Dry and Wet Methods (건식/습식 방법을 이용한 토목섬유의 유효구멍크기 측정방법 평가)

  • Kim, Ju-Hyong;Cho, Sam-Deok
    • Journal of the Korean Geotechnical Society
    • /
    • 제23권2호
    • /
    • pp.19-27
    • /
    • 2007
  • Dry and wet test methods established by Korean industrial standards to estimate opening size of 3 types of geotextile which are widely used for filter of plastic drain board in Korea are performed to evaluate characteristics of the test methods and to compare the test results. Judging from test results, dry method is a relatively poor test, having lots of problems causing many errors but a simple-quick test. Wet method is a very specific test avoiding many of the problems of dry method such as electrostatic charges, trapping in the geotextiles and so on. However, one of wet test methods, KS K ISO 12956, takes long time to complete a test and is too strict to handle loss of granular material. Generally, opening size of a geotextile by wet test method is smaller than that of dry test method. Especially, opening size by KS F 2126 which is called hydrodynamic method but at present is not used anymore is similar to or smaller than that by KS K ISO 12956 method.

Review of Revised KOLAS Standard Regulations for Test and Calibration Laboratories: General Requirements for a Competence of Management System (KOLAS 시험 및 교정기관 운영을 위한 개정된 표준 규정 리뷰: 적격성에 대한 일반 요구사항)

  • Kim, Hee Sun
    • Applied Chemistry for Engineering
    • /
    • 제31권3호
    • /
    • pp.334-337
    • /
    • 2020
  • Korea Laboratory Accreditation Scheme (KOLAS) introduces a new standard for test and calibration laboratories to operate management system and to produce valid results in accordance with the requirements of KS Q ISO/IEC 17025. The standard is based on the national standard law for the accreditation of test, inspection and calibration laboratories. International Laboratory Accreditation Cooperation (ILAC) has recently established its new criteria. The accredited test and calibration laboratories should complete the transition of their management system by November 2020 following KS Q ISO/IEC 17025:2017. A total of 899 of test, inspection and calibration laboratories in Korea are influenced by the transition policy. This paper summarized general requirements for a competence of laboratory management system.