• Title/Summary/Keyword: KOMAC

Search Result 24, Processing Time 0.032 seconds

Design of A 350MHz RFQ for the KOMAC 1 GeV Proton Linac

  • J. M. Han;Y. S. Cho;Park, B. H.;S. H. Jin;I. S. Ko;B. S. Kang;B. S. Han
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.957-962
    • /
    • 1998
  • As the first stage accelerator of the Korea Multipurpose Accelerator Complex (KOMAC) 1GeV proton linac, a 350MHZ, cw Radio-Frequency Quadrupole (RFQ) will be built to produce 20㎃ of 3Mev. High current RFQ with cw operation is a major program in the KOMAC project to understand beam dynamics, engineering design, construction, control and diagnostics techniques. The beam dynamics and the engineering design of RFQ are described and the present status of the KOMAC RFQ project is discussed.

  • PDF

Study on production process of graphite for biological applications of 14C-accelerator mass spectrometry

  • Ha, Yeong Su;Kim, Kye-Ryung;Cho, Yong-Sub;Choe, Kyumin;Kang, Chaewon
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.6 no.1
    • /
    • pp.20-26
    • /
    • 2020
  • Accelerator mass spectrometry (AMS) is a powerful detection technique with the exquisite sensitivity and high precision compared with other traditional analytical techniques. Accelerator mass spectrometry can be widely applied in the technique of radiocarbon dating in the fields of archeology, geology and oceanography. The ability of accelerator mass spectrometry to measure rare 14C concentrations in microgram and even sub-microgram amounts suggests that extension of 14C-accelerator mass spectrometry to biomedical field is a natural and attractive application of the technology. Drug development processes are costly, risky, and time consuming. However, the use of 14C-accelerator mass spectrometry allows absorption, distribution, metabolism and excretion (ADME) studies easier to understand pharmacokinetics of drug candidates. Over the last few decades, accelerator mass spectrometry and its applications to preclinical/clinical trials have significantly increased. For accelerator mass spectrometry analysis of biological samples, graphitization processes of samples are important. In this paper, we present a detailed sample preparation procedure to apply to graphitization of biological samples for accelerator mass spectrometry.

A Study on Measurement of Gamma-ray Spectrum for the Natural Tungsten nuclear reaction by using KOMAC proton Linear Accelerator (KOMAC 양성자 선형가속기를 이용한 천연 텅스텐 핵반응에 대한 감마선 스펙트럼 측정에 대한 연구)

  • Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.133-138
    • /
    • 2018
  • The measurement of gamma-ray spectrum of $^{nat}W(p,xn)$ reaction with natural tungsten were performed by using a high energy proton generated from a 100-MeV proton linear accelerator of the Korea Multi-purpose Accelerator Complex (KOMAC). Gamma rays generated by various nuclides generated through the nuclide were measured using a gamma-ray spectroscopy system composed of HPGe detector. A gamma-ray standard source was used for energy calibration and efficiency measurement of the detector. Analysis of the gamma rays observed in the measured spectra showed that the radionuclides produced were $^{167}Re$, $^{178}Re$, $^{179}Re$, $^{180}Re$, $^{181}Re$, $^{182}Re$, $^{184}Re$, $^{172}Ta$, $^{174}Ta$, $^{178}Ta$, $^{182}Ta$, $^{184}Ta$, $^{175}W$, $^{176}W$, $^{177}W$ and $^{179}W$. Nuclides were generated. The results of this study will be applied to nuclear fusion, astrophysics, and nuclear medicine applications in the future.

Comparative study of 82Sr separation/purification methods used at Brookhaven National Laboratory and ARRONAX

  • Ha, Yeong Su;Yoon, Sang-Pil;Kim, Han-Sung;Kim, Kye-Ryung
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.5 no.2
    • /
    • pp.71-78
    • /
    • 2019
  • Nuclear imaging is one of the most powerful measures for non-invasive diagnosis of myocardial vascular disease. Radionuclide such as 13N, 15O, 201Tl and 82Rb is used for the measurement of cardiac blood flow. 13N, 15O and 201Tl are produced in cyclotrons while 82Rb is obtained from generator. Rubidium (Rb), an alkali ion, behaves biologically like potassium, and accumulates in myocardial tissue. Rb has rapid blood clearance profile which allows the use of 82Rb with a short physical half-life of 75 s for non-invasive evaluation of regional myocardial perfusion. There are several advantages of 82Rb over other radioisotopes. An ultra-short half-life significantly reduces the exposure of patients to radiation and allows to repeat injections for studying the effects of medical intervention. As a positron emitter, 82Rb allows positron emission tomography (PET) imaging which have shown superior diagnostic performances. 82Rb can be produced from generator by decay of its parent 82Sr. However, the preparation of 82Sr is difficult, because appropriate purity is required to meet the specification of the product. Recently reported procedure from ARRONAX research institute showed that a Chelex-100 resin is sufficient for this purpose and additional column is not necessary. Whereas Brookhaven National Laboratory (BNL) procedure contains three ion exchange resin separation, including Chelex-100 resin. Currently, since 82Sr production site is non-existent in Korea, Korea Atomic Energy Research Institute (KAERI) has plan to produce 82Sr within specifications. We compared 82Sr purification procedures reported from ARRONAX and BNL to investigate the most suitable procedure for our conditions.

Conceptual Design of the Superconducting Linac for KOMAC

  • Kim, Sang-Ho;Kim, Young-Hwan;Kim, Han-Sung;Lee, Kang ok;Chung, Kie-Hyung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.967-971
    • /
    • 1998
  • KOMAC (KOrea Multi-purpose Accelerator Complex) is the 1 Gev, 20 ㎃ proton linac. The superconducting linac for the high energy part acceleration from 100 MeV to 1 GeV is selected as a main candidate. As is well known, the superconducting linac has advantages for high current, high energy acceleration such as a large bore size, short accelerator length, and the RF efficiency. In this energy, the velocity of proton increases from $\beta$=0.87. For the design and fabrication simplicity, the cavity $\beta$ stages are divided into 3 parts. The maximum electric field in the cavity is designed below 20 ㎹/m. In this paper the design concepts and guides for this superconducting linac are introduced.

  • PDF

Design Parameter of CW Klystron System for KOMAC

  • Lee, J. H.;H. J. Kwon;Kim, T. Y.;K. H. Chung;H. S. Kang;Park, S. J.;J. S. Oh;Kim, Dong-Il
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.963-966
    • /
    • 1998
  • The KOMAC(KOrea Multi-purpose Accelerator Complex) linac is composed of RFQ(Radio Frequency Quadrupole), CCDTL(Coupled Cavity Drift Tube Linac) and SC(Superconducting)-linac. The required CW output power of RF system is about 25㎿ for 20㎿ proton beam power. Therefore high power RF sources are necessary for cost saving and reliability improvement. The number of klystrons for 0.5 ㎿ at 350MHz and 1 ㎿ at 700MHz are 1 and 31, respectively. In this paper, the design parameters of the klystron system including power supply and energy recovery system are presented.

  • PDF

KOMAC RFQ Vacuum System

  • Han, J.M.d;S.H.Jeong;Cho, Y.S.;Park, B.H.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.33-33
    • /
    • 1999
  • The design of a vacuum pumping system for the KOMAC (Korea Multipurpose Accelerator Complex) RFQ(Radio-Frequency Quadrupole) linac is described. [Fig] Resulted from the lost proton beam, gas streaming from the LEBT (Low Energy Beam Transport) and out-gassing from the surfaces of the RFQ cavity and vacuum plumbing, the total gas load will be on the order of 7.2$\times$10-4 Torr-liters/sec, consisting mainly of hydrogen. The system designed to pump on a continual basis with redundancy to ensure that the minimal operating vacuum level of 1.0$\times$10-6 Torr is maintained even under abnormal conditions. Details of the design, performance analysis and the preliminary test results of the cryogenic pumps are presented.