• Title/Summary/Keyword: KINEMATICS

Search Result 1,681, Processing Time 0.023 seconds

3-Dimensional Gait analysis and the relationship between lower limb alignment and knee adduction moment in elderly healthy women (3차원적 동작 분석기를 이용한 건강한 여자 노인의 하지 정렬 상태와 슬관절 내전 모멘트의 상관 관계에 관한 연구)

  • Cho, You-Mi;Lee, Wan-Hee
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.1
    • /
    • pp.90-101
    • /
    • 2003
  • Gait analysis can provide a better understanding of how the alignment of the lower limb and foot can contribute to force observed at the knee. Anatomic and mechanical factors that affect loading in the knee pint can contribute to pathologic change seen at the knee in degenerative pint disease and should be considered in treatment plan. The purpose of this study is to present the gait analysis data and to determine whether there is any relationships between alignment of the lower limb, foot progression angle and knee pint moments in elderly healthy women with 3-dimensional motion analyzer. The results were as follows; 1. Cadence showed 114.8 steps/min, gait speed showed 1.05 m/s, time per a stride showed 1.06 sec, time per a step showed 0.53 sec, single-supporting phase was 0.41 sec, double-supporting phase was 0.24 sec, stride length was 1.04 m, Step length was 0.56 m. 2. According to the parameters of kinematics, the maximal knee flexion angle through swing phase showed left $46.82^{\circ}$, right $40.19^{\circ}$ and the maximal knee extension angle showed left $-1.32^{\circ}$, right $2.01^{\circ}$. knee varus showed left $26.90^{\circ}$, right $30.93^{\circ}$. 3. Moment, one of kinetic parameters of knee pint the maximal flexion moment showed left 0.363. Nm/kg, right 0.464 Nm/kg and maximal extension moment showed left 0.389 Nm/kg, right 0.463 Nm/kg. The maximal. adduction moment showed left 0.332 Nm/kg, right 0.379 Nm/kg and the maximal internal rotatory moment showed left 0.13 Nm/kg, right 0.140 Nm/kg. 4. On sagittal plane, the maximal power of knee joint showed left 0.571 J/kg, right 0.629 J/kg. On coronal plane, the maximal power of knee joint showed left 0.11 J/kg, right 0.12 J/kg. On transverse plane, the maximal power of knee joint showed left 0.058 J/kg, right 0.072 J/kg. 5. The subject who had varus alignment of the lower extremity had statistically higher in knee adduction moment in mid stance phase. 6. The subject who had large foot progression angle had statistically lower in knee adduction moment in late stance phase. A relationship was observed between the alignment of the lower extremity and the adduction moment of the knee joint during stance phase. Hence, we need some research to figure, out the change of adduction moment according to the sort of knee joint osteoarthritis and the normal geriatrics as well. And we also require more effective, specific therapeutic program by making use of those background of researches.

  • PDF

Unlinked and Convertible Total Elbow Arthroplasty (비연결형 및 전환형 주관절 전치환술)

  • Moon, Jun-Gyu;Chun, Sung-Kwang
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.2
    • /
    • pp.163-169
    • /
    • 2013
  • Designs of total elbow arthroplasty have been evolving with clinical experiences. Newer implants are expected to resolve current limitations and improve long term outcomes. This review article focuses on the basic knowledge of unlinked and convertible total elbow arthroplasty. There have been a variety of designs of unlinked total elbow prostheses. Some implants are still used in the market, while others are no longer commercially available. Modified and newer designs include more congruent contact surface, stemmed implant, and radiocapitellar arthroplasty. Two convertible elbow prostheses have been developed, and one implant is currently available in Korea. Conversion from an unlinked to a linked mode is performed by adding a linking cap. Unlinked total elbow arthroplasty, which restores native elbow kinematics, has a biomechanical rationale of lowering polyethylene wear and loosening of implants. It can be indicated in younger and higher demand patients, who have adequate bone stock and soft tissues. Convertible total elbow arthroplasty broadens implant selection and simplifies revision surgery. These newer prostheses possibly improve the long term outcomes and resolve disadvantages of linked prostheses in total elbow arthroplasty.

Optimal Sensor Allocation for Health Monitoring of Roller-Coaster Structure (롤러코스터의 모니터링을 위한 최적 센서 구성)

  • Heo, Gwang Hee;Jeon, Seung Gon;Park, In Joon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.4
    • /
    • pp.165-174
    • /
    • 2011
  • This research aims at the optimal constitution of sensors required to identify the structural shortcoming of roller-coaster. In this research we analyzed the dynamic characteristics of roller-coaster by three dimensional FE modelling, decided on the appropriate location and number of sensors through optimal transducer theory, abstracted the mathematical value of modal features before and after damage on the basis of optimally placed and numbered sensors. and then presented it as a primary information about the basic structure which would be applied to damage estimation. As a target structure, the roller-coater at Seoul Children's Grand Park was chosen and built as a model reduced by one twentieth in size. In order to consider the Kinetics features particular to the roller-coaster structure, we made an exact three-dimensional FE modelling for the model structure by means of Spline function. As for the proper location and number of sensors, it was done by applying EIM and EOT. We also estimated the damage from the combination of strength, flexibility, and model corelation after abstracting the value of modal features. Finally the optimal transducer theory presented here in this research was proved to be valid, and the structural damage was well identified through changes in strength and flexibility. As a result, we were able to present the optimal constitution of sensors needed for the analysis of dynamic characteristics and the development of techniques in dynamic characteristics, which would ultimately contribute to the development of health monitoring for roller-coaster.

A Preliminary Study on the Exhumation Mechanism of the Paleozoic Gwangcheon Gneiss in the Southwestern Margin of the Gyeonggi Massif (경기육괴 남서 연변부에 발달하는 고생대 광천편마암의 노출기작에 대한 예비 연구)

  • Park, Seung-Ik
    • Economic and Environmental Geology
    • /
    • v.50 no.6
    • /
    • pp.525-535
    • /
    • 2017
  • Exhumation mechanism of migmatite in orogenic belts provides insights into thermo-mechanical evolution of lithosphere in association with orogeny. This study deals with kinematics of structures in and around the Gwangcheon Gneiss, as a preliminary study on exhumation mechanism, which is a main constituent of a domal structure (viz., Oseosan Dome) in the Hongseong area, southwestern margin of the Gyeonggi massif. Geological structures in the Gwangcheon Gneiss, which mainly comprises southern and northwestern part of the Oseosan Dome, generally have kinematic component of top-outward shear. This feature is likely to represent diapiric dome-up movement. In addition, a high strain zone, by which the tectonic domain involving the Gwangcheon Gneiss is bounded on the west, show structural features with normal sense of shear component. Taking available (thermo)chronological data into account, it is interpreted that activation of the high strain zone and exhumation of the Gwangcheon Gneiss occurred during Late Triassic, when the Gyeonggi massif was widely affected by post-collisional processes. It means that the Gwangcheon Gneiss was diapirically moved up and exhumed in the footwall of extensional high strain zone in association with Triassic post-collisional processes.

Enhancement of Manganese Removal Ability from Water Phase Using Biochar of Prinus densiflora Bark (소나무 수피 바이오차를 이용한 수중에서 망간의 제거능력 향상)

  • Kim, Min-Ji;Choi, Jung Hoon;Choi, Tae Ryeong;Choi, Suk Soon;Ha, Jeong Hyub;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.31 no.5
    • /
    • pp.526-531
    • /
    • 2020
  • Manganese ions contained in water phase are acting as a toxic substance in the human body and also known to affect the nervous system. In particular, effective treatment technology is required since manganese removal is difficult due to its high solubility in a wide pH range. In this study, Prinus densiflora bark was chemically modified with hydrogen peroxide, and the modified adsorbent was used for removing manganese ions in an aqueous solution. The modified adsorbent showed high removal capacity of 82.1 and 56.2%, respectively, at conditions of 5 and 10 mg/L manganese ions. Also, the adsorption isotherm from the data was applied to the theoretical equation. As a result, the adsorption behavior of manganese ions was better suited to the Langmuir than Freundlich model, and it was also found from kinematics that the pseudo-second order kinetic model was more suitable. In addition, the changes of Gibbs free energy indicated that the adsorption reaction became more spontaneously with increasing temperature. Consequently, these experimental results may be used as a water treatment technology which can efficiently treat manganese ions contained in water.

Image Quality of a Rotating Compton Camera Evaluated by Using 4-D Monte Carlo Simulation Technique (4-D 전산모사 기법을 이용한 호전형 컴프턴 카메라의 영상 특성 평가)

  • Seo, Hee;Lee, Se-Hyung;Park, Jin-Hyung;Kim, Chan-Hyeong;Park, Sung-Ho;Lee, Ju-Hahn;Lee, Chun-Sik;Lee, Jae-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.3
    • /
    • pp.107-114
    • /
    • 2009
  • A Compton camera, which is based on Compton kinematics, is a very promising gamma-ray imaging device in that it could overcome the limitations of the conventional gamma-ray imaging devices. In the present study, the image quality of a rotating Compton camera was evaluated by using 4-D Monte Carlo simulation technique and the applicability to nuclear industrial applications was examined. It was found that Compton images were significantly improved when the Compton camera rotates around a gamma-ray source. It was also found that the 3-D imaging capability of a Compton camera could enable us to accurately determine the 3-D location of radioactive contamination in a concrete wall for decommissioning purpose of nuclear facilities. The 4-D Monte Carlo simulation technique, which was applied to the Compton camera fields for the first time, could be also used to model the time-dependent geometry for various applications.

ON THE GALACTIC SPIRAL PATTERNS: STELLAR AND GASEOUS

  • MARTOS MARCO;YANEZ MIGUEL;HERNANDEZ XAVIER;MORENO EDMUNDO;PICHARDO BARBARA
    • Journal of The Korean Astronomical Society
    • /
    • v.37 no.4
    • /
    • pp.199-203
    • /
    • 2004
  • The gas response to a proposed spiral stellar pattern for our Galaxy is presented here as calculated via 2D hydrodynamic calculations utilizing the ZEUS code in the disk plane. The locus is that found by Drimmel (2000) from emission profiles in the K band and at 240 ${\mu}m$. The self-consistency of the stellar spiral pattern was studied in previous work (see Martos et al. 2004). It is a sensitive function of the pattern rotation speed, $\Omega$p, among other parameters which include the mass in the spiral and its pitch angle. Here we further discuss the complex gaseous response found there for plausible values of $\Omega$p in our Galaxy, and argue that its value must be close to $20 km s^{-l}\;kpc^{-1}$ from the strong self-consistency criterion and other recent, independent studies which depend on such parameter. However, other values of $\Omega$p that have been used in the literature are explored to study the gas response to the stellar (K band) 2-armed pattern. For our best fit values, the gaseous response to the 2-armed pattern displayed in the K band is a four-armed pattern with complex features in the interarm regions. This response resembles the optical arms observed in the Milky Way and other galaxies with the smooth underlying two-armed pattern of the old stellar disk populations in our interpretation. The complex gaseous response appears to be related to resonances in stellar orbits. Among them, the 4:1 resonance is paramount for the axisymmetric Galactic model employed, and the set of parameters explored. In the regime seemingly proper to our Galaxy, the spiral forcing appears to be marginally strong in the sense that the 4:1 resonance terminates the stellar pattern, despite its relatively low amplitude. In current work underway, the response for low values of $\Omega$p tends to remove most of the rich structure found for the optimal self-consistent model and the gaseous pattern is ring-like. For higher values than the optimal, more features and a multi-arm structure appears.

The Effect of High-Heeled Shoes With Total Contact Inserts in the Gait Characteristics of Young Female Adults During Lower Extremity Muscle Fatigue (하지 근육의 피로상태 동안 높은 굽 신발에 적용한 전면접촉인솔이 젊은 여성의 보행 특성에 미치는 영향)

  • Ko, Eun-Hye;Choi, Houng-Sik;Kim, Tack-Hoon;Cynn, Heon-Seock;Kwon, Oh-Yun;Choi, Kyu-Han
    • Physical Therapy Korea
    • /
    • v.15 no.1
    • /
    • pp.38-45
    • /
    • 2008
  • This study investigated gait characteristics, kinematics, and kinetics in the lower extremities between two different shoe conditions (high heeled shoes (7 cm), and high heeled shoes with a total contact insert (TCI)) after lower extremity muscle fatigue. Although TCI shave been applied in high heeled shoes to increase comfort and to decrease foot pressure, no study has attempted to identify the effects of TCI in fatigue conditions. The purpose of this study was to determine the effects of walking in high heeled shoes with TCI after lower extremity muscle fatigue was induced. This study was carried out in a motion analysis laboratory at Hanseo University. A volunteer sample of 14 healthy female subjects participated. All in fatigue conditions, the subjects were divided into two groups. The muscle fatigue was induced by 40 voluntary dorsi- and plantar-flexion exercises and 40 heel-rise exercises of the dominant foot. Surface electromyography was used to confirm the localized muscle fatigue using power spectral analysis of three muscles (tibialis anterior, gastrocnemius medialis and lateralis). The results were as follows: (1) In muscle fatigue conditions, the use of TCI decreased the peak flexion angle of the hip joint significantly in the early stance phase (p<.05) and increased the peak hip flexion moment in the terminal stance phase (p<.05). (2) In muscle fatigue conditions, the application of TCI also increased peak hip power generation in the early stance phase and peak hip power absorption in the terminal stance phase (p<.05). (3) In muscle fatigue conditions, the use of TCI reduced the impact force significantly and increased the secondary peak vertical GRF. These findings suggest that the TCI may provide beneficial effects when muscle fatigue occurs for a high heeled shoe gait. Future research employing the patient population and various types of TCI materials are required to clarify the effects of TCI.

  • PDF

The Effects of Wearing Roller Shoes on Ground Reaction Force Characteristics During Walking (롤러 신발과 조깅 슈즈 신발 착용 후 보행 시 지면반력의 형태 비교 분석)

  • Chae, Woen-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.1
    • /
    • pp.101-108
    • /
    • 2006
  • The purpose of this study was to compare GRF characteristics during walking wearing jogging and roller shoes. Twelve male middle school students (age: $15.0{\pm}0.0\;yrs$, height: $173.6{\pm}5.0\;cm$, weight: $587.6{\pm}89.3\;N$) who have no known musculoskeletal disorders were recruited as the subjects. Kinematic data from six S-VHS camcorders(Panasonic AG456, 60 fields/s) and GRF data from two force platform; (AMII OR6-5) were collected while subjects walked wearing roller and jogging shoes in random order at a speed of 1.1 m/s. An event sync unit with a bright LED light was used to synchronize the video and GRF recordings. GRF data were filtered using a 20 Hz low pass Butterworth. digital filter and further normalized to the subject's body weight. For each trial being analyzed, five critical instants and four phases were identified from the recording. Temporal parameters, GRFs, displacement of center of pressure (DCP), and loading and decay rates were determined for each trial. For each dependent variable, paired t-test was performed to test if significant difference existed between shoe conditions (p <.05). Vertical GRFs at heel contact increased and braking forces at the end of initial double limb stance reduced significantly when going from jogging shoe to roller shoe condition. Robbins and Waked (1997) reported that balance and vertical GRF are closely related It seems that the ankle and knee joints are locked in an awkward fashion at the heel contact to compensate for the imbalance. The DCP in the antero-posterior direction for the roller shoe condition was significantly less than the corresponding value for the jogging shoe condition. Because the subjects tried to keep their upper body weight in front of the hip to prevent falling backward, the DCP for the roller shoe condition was restricted The results indicate that walking with roller shoes had little effect on temporal parameters, and loading and decay rates. It seems that there are differences in GRF characteristics between roller shoe and jogging shoe conditions. The differences in GRF pattern may be caused primarily by the altered position of ankle, knee, and center of mass throughout the walking cycle. Future studies should examine muscle activation patterns and joint kinematics during walking with roller shoes.

The Differences of the Normalized Jerk According to Shoes, Velocity and Slope During Walking (보행시 신발, 속도, 그리고 경사도에 따른 정규 저크의 차이)

  • Han, Young-Min;Choi, Jin-Seung;Kim, Hyung-Sik;Lim, Young-Tae;Yi, Jeong-Han;Tack, Gye-Rae;Yi, Kyung-Ok;Park, Seung-Bum
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.2
    • /
    • pp.1-8
    • /
    • 2006
  • The purpose of this study was to evaluate normalized jerk according to shoes, slope, and velocity during walking. Eleven different test subjects used three different types of shoes (running shoes, mountain climbing boots, and elevated forefoot walking shoes) at various walking speeds(1.19, 1.25, 1.33, 1.56, 1.78, 1.9, 2, 2.11, 2.33m/sec) and gradients(0, 3, 6, 10 degrees) on a treadmill. Since there were concerns about using the elevated forefoot shoes on an incline, these shoes were not used on a gradient. Motion Analysis (Motion Analysis Corp. Santa Rosa, CA USA) was conducted with four Falcon high speed digital motion capture cameras. Utilizing the maximum smoothness theory, it was hypothesized that there would be differences in jerk according to shoe type, velocity, and slope. Furthermore, it was assumed that running shoes would have the lowest values for normalized jerk because subjects were most accustomed to wearing these shoes. The results demonstrated that elevated forefoot walking shoes had lowest value for normalized jerk at heel. In contrast, elevated forefoot walking shoes had greater normalized jerk at the center of mass at most walking speeds. For most gradients and walking speeds, hiking boots had smaller medio-lateral directional normalized jerk at ankle than running shoes. These results alluded to an inverse ratio for jerk at the heel and at the COM for all types of shoes. Furthermore, as velocity increased, medio-lateral jerk was reduced for all gradients in both hiking boots and running shoes. Due to the fragility of the ankle joint, elevated forefoot walking shoes could be recommended for walking on flat surfaces because they minimize instability at the heel. Although the elevated forefoot walking shoes have the highest levels of jerk at the COM, the structure of the pelvis and spine allows for greater compensatory movement than the ankle. This movement at the COM might even have a beneficial effect of activating the muscles in the back and abdomen more than other shoes. On inclines hiking boots would be recommended over running shoes because hiking boots demonstrated more medio-lateral stability on a gradient than running shoes. These results also demonstrate the usefulness of normalized jerk theory in analyzing the relationship between the body and shoes, walking velocity, and movement up a slope.