Hydrogen sensor of SWNT-PdOx system using the vacuum filtering deposition method (진공여과증착법을 이용한 SWNT-PdOx계 수소센서)

  • Kim, Il-Jin;Park, Kee-Bae
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.87-91
    • /
    • 2010
  • Hydrogen gas sensors were fabricated using $PdO_x$ loaded with SWNTs. The nanoparticle powders of $SWNT_s-PdO_x$ composite were deposited on Si wafer substrates by a vacuum filtering deposition method. The fabricated sensors were tested against hydrogen gas. The composition ratio that exhibited the highest response to hydrogen gases was SWNTs : $PdO_x$ = 98 : 2 in wt% ratio at operating temperature of about $150^{\circ}C$. The response and recovery times were shorter than 1.0 min. in presence of 1000 ppm hydrogen.

Prospect and Influence Analysis of Jeju Wind Power System (제주풍력 전망 및 계통영향 분석)

  • Kim, Yeong-Hwan;Kang, Jee-Yoon;Byeon, Kun-Ik;Woo, Hyun-Chul;Kim, Gun-Hoon;Kim, Se-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.275-276
    • /
    • 2008
  • Construction of wind power plant is rapidly increasing since Jeju is known as the most suitable regarding wind power plants in Korea. But implementing wind power generation inevitably introduces new challenges due to its intermittent nature. In the paper, it is introduced the prospect of wind plant construction and influence analysis in Jeju power system.

  • PDF

The Heuristic Approach to the Order Consolidation Problem (주문 집약 문제에 대한 휴리스틱 기법)

  • Park, Jongho;Lim, Kyungkuk;Choi, Bongha
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.34 no.4
    • /
    • pp.408-413
    • /
    • 2008
  • We consider the batch processing of orders where either whole or part of a single order or a specific pair of different orders may be grouped in a batch within a fixed capacity. Our objective is to maximize the total number of batches filled up to the batch size. In this paper, we study the Level-2 problem where at most 2 kinds of orders can be grouped in a batch. This problem is known to be NP-hard and Max SNP-hard. So we develop heuristic algorithm and evaluate the performance of the algorithm.

Experimental Study on Single Bubble Growth Under Subcooled, Saturated, and Superheated Nucleate Pool Boiling

  • Kim Jeong-Bae;Lee Jang-Ho;Kim Moo-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.692-709
    • /
    • 2006
  • Nucleate pool boiling experiments with constant wall temperature were performed using pure R1l3 for subcooled, saturated, and superheated pool conditions. A microscale heater array and Wheatstone bridge circuits were used to maintain the constant wall temperature and to measure the instantaneous heat flow rate accurately with high temporal and spatial resolutions. Images of bubble growth were taken at 5,000 frames per second using a high-speed CCD camera synchronized with the heat flow rate measurements. The bubble geometry was obtained from the captured bubble images. The effect of the pool conditions on the bubble growth behavior was analyzed using dimensionless parameters for the initial and thermal growth regions. The effect of the pool conditions on the heat flow rate behavior was also examined. This study will provide good experimental data with precise constant wall temperature boundary condition for such works.

A Study on the Islanding Detection for Grid Connected Photovoltaic System (계통연계형 태양광발전시스템을 위한 단독운전 검출에 관한 연구)

  • Lee Gi-Je;Kim Min;Lee Jin-Seop;Yu Gwon-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.555-558
    • /
    • 2002
  • The general ways of the anti-islanding can be classified into the active method and passive method. The passive method which use only the voltage information when power failure occurs has much possibility of the wrong detection. And the active method detects the change of the voltage frequency as instantaneously changing the frequency of the inverter output current. Therefore, in this paper, the method to inject arbitrary order harmonics into controlled current is proposed. In this method islanding can be detected by measuring the amount of load voltage of injected harmonics order. And as a current control method predictive control method is used, which make actual current accurately to track reference current by Instantaneously computing converter output voltage and has fast response in transient state. This parer proposed method was verified by simulation.

  • PDF

Analysis of Performance Characteristic for Small Scale Hydro Power Plant with Rainfall Condition Change (강우형태 변화에 의한 소수력발전소 성능특성분석)

  • Park, Wan-Soon;Lee, Chul-Hyung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.614-618
    • /
    • 2009
  • The effects of design parameters for small scale hydro power(SSHP) plants due to rainfall condition have been studied. The model to predict hydrologic performance for SSHP plants is used in this study. The results from analysis for rainfall conditions based on KIER model show that the capacity and load factor of SSHP site had large difference between the period. Especially, the hydrologic performance of SSHP site such as design flowrate due to rainfall condition of recent period varied sensitively. And also, the methodology represented in this study can be used to decide the primary design specifications of SSHP sites.

  • PDF

Phase Equilibrium of the Carbon Dioxide and Methane Hydrate in Silica Gel Pores and Thermodynamic Prediction (실리카겔 공극에서의 이산화탄소 및 메탄 하이드레이트 상평형 측정 및 열역학적 예측)

  • Kang, Seong-Pil
    • New & Renewable Energy
    • /
    • v.3 no.2 s.10
    • /
    • pp.47-52
    • /
    • 2007
  • Hydrate phase equilibrium for the binary $CO_{2}$+water and $CH_{4}$+water mixtures in silica gel pore of nominal 6, 30, and 100 nm were measured and compared with the cacluated results based on van der Waals and Platteeuw model. At a specific temperature three-phase hydrate-water-vapor (HLV) equilibrium curves for pore hydrates were shifted to the higher-pressure condition depending on pore sizes when compared with those of bulk hydrates. Notably, hydrate phase equilibria for the case of 100 nominal nm pore size were nearly identical with those of bulk hydrates. The activities of water in porous silica gels were modified to account for capillary effect, and the calculation results were generally in good agreement with the experimental data.

  • PDF

Experimental Study on the Thermal Performance of Passive Solar Trombe Wall System (자연형태양열 트롬월 축열벽 시스템의 열성능 특성 실측 분석 연구)

  • Yoon, Jong-Ho;Baek, Nam-Choon;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.1
    • /
    • pp.75-81
    • /
    • 2008
  • Thermal performance of passive solar Trombe wall system which is applied on the south wall of KIER Zero energy Solar House has been monitored for 6 months of heating season. Based upon the long-term measurement results, extensive statistical analysis was conducted to investigate temperature profiler and heat flow pattern in Trombe wall system under actual operating condition. Heat flow characteristics depending on the time variation of day and month was clearly revealed. Heat gain and loss on the inner surface of the Trombe wall was calculated base upon measured temperature data. Those results would be utilized to improve the efficiency of new type solar storage wall system.

On-line Optimal Control Technology for Central Heating System (중앙난방시스템의 온라인 최적제어기법에 관한 연구)

  • Ahn Byung Cheon;Choi Sang Gon;Cho Sung Hwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.2
    • /
    • pp.140-146
    • /
    • 2005
  • The on-line optimal control algorithm for central heating system has been researched for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as indoor heating load and outdoor temperature variation. This study has been done by using TRNSYS Program in order to analyze the central heating system. The optimal control algorithm shows good energy Performances in comparison with the conventional one.

A Study of Rule-based Fault Detection Algorithm in the HVAC System (규칙기반 고장진단 알고리즘의 실험적 연구)

  • Cho, Soo;Tae, Choon-Seob;Jang, Cheol-Yong;Yang, Hoon-Cheol
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.241-246
    • /
    • 2005
  • The objective of this study is to develop a rule-based fault detection and diagnosis algorithm and an experimental verification using air handling unit. To develop an analytical algorithm which precisely detects a faulted component, energy equations at each control volume of AHU were applied. An experimental verification was conducted in the AHU at Green Building in KIER. In the experiment conducted in hot summer condition, the rule based FDD algorithm isolated a faulted sensor from HVAC components.

  • PDF