Photon Beam에 대한 Kerma와 흡수선량의 측정 (A Measurement of Kerma and Absorbed Dose in Photon Fields)

  • 김성희;신승애;추성실
    • Journal of Radiation Protection and Research
    • /
    • 제11권1호
    • /
    • pp.77-82
    • /
    • 1986
  • Kerma와 흡수선량 사이의 관계를 결정하는 것은 선량측정의 기본적인 문제이다. 본 연구에서는 고에너지 치료용 선형가속기의 6MV X-선과 감마치료기의 $^{60}Co$에 대한 kerma와 흡수선량을 측정하였다. 본 실험결과는 $^{60}Co$감마선에 의한 물과 알루미늄의 과도 평형 영역에서의 흡수선량이 실제적으로 kerma와 일치하였으며, 최대선량 깊이는 6MV와 $^{60}Co$에서 각각 $1.45g/cm^2$$0.48g/cm^2$이었다. 최대 build-up에서의 흡수선량과 표면에서의 충돌 kerma의 비($K^{att}$)는 표준 조사면에서 물과 알루미늄에 대해, 6MV인 경우는 0.949, $^{60}Co$인 경우는 0.992이었다. 이 결과는 $K^{att}$의 물질에 대한 의존성이 매우 작음을 보여준다.

  • PDF

Analytical Consideration of Surface Dose and Kerma for Megavoltage Photon Beams in Clinical Radiation Therapy

  • Birgani, Mohammad Javad Tahmasebi;Behrooz, Mohammad Ali;Razmjoo, Sasan;Zabihzadeh, Mansour;Fatahiasl, Jafar;Maskni, Reza;Abdalvand, Neda;Asgarian, Zeynab;Shamsi, Azin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권1호
    • /
    • pp.153-157
    • /
    • 2016
  • Background: In radiation therapy, estimation of surface doses is clinically important. This study aimed to obtain an analytical relationship to determine the skin surface dose, kerma and the depth of maximum dose, with energies of 6 and 18 megavoltage (MV). Materials and Methods: To obtain the dose on the surface of skin, using the relationship between dose and kerma and solving differential equations governing the two quantities, a general relationship of dose changes relative to the depth was obtained. By dosimetry all the standard square fields of $5cm{\times}5cm$ to $40cm{\times}40cm$, an equation similar to response to differential equations of the dose and kerma were fitted on the measurements for any field size and energy. Applying two conditions: a) equality of the area under dose distribution and kerma changes in versus depth in 6 and 18 MV, b) equality of the kerma and dose at $x=d_{max}$ and using these results, coefficients of the obtained analytical relationship were determined. By putting the depth of zero in the relation, amount of PDD and kerma on the surface of the skin, could be obtained. Results: Using the MATLAB software, an exponential binomial function with R-Square >0.9953 was determined for any field size and depth in two energy modes 6 and 18MV, the surface PDD and kerma was obtained and both of them increase due to the increase of the field, but they reduce due to increased energy and from the obtained relation, depth of maximum dose can be determined. Conclusions: Using this analytical formula, one can find the skin surface dose, kerma and thickness of the buildup region.

DR(Digital Radiography)에서 PCXMC 2.0을 이용한 Kerma와 다목적 선량계, 유리선량계의 선량비교를 통한 흡수선량 평가 시 유리선량계의 유용성에 관한 연구 (A Study on the Usefulness of Glass Dosimeter in the Evaluation of Absorbed Dose by Comparing the Doses of Multi-purpose Dosimeter and Glass Dosimeter Using Kerma with PCXMC 2.0 in DR(Digital Radiography))

  • 황준호;이경배
    • 한국콘텐츠학회논문지
    • /
    • 제17권9호
    • /
    • pp.292-299
    • /
    • 2017
  • 방사선 방호는 결정적 영향을 방지하고 확률적 영향을 최소화하는데 목적이 있다. 결정적 영향과 확률적 영향을 과대평가하면 미래에 일어날 위험성에 대해 잘못된 평가를 내릴 수 있기 때문에 이들의 기본량인 흡수선량의 정확한 평가가 특히 중요하다. 본 연구는 몬테카를로 시뮬레이션을 기반으로 한 PCXMC 2.0을 이용하여 Kerma를 측정하고, 다목적 선량계 및 유리선량계를 이용하여 나타난 선량을 비교하여 정확한 흡수선량을 평가하는 것에 목적을 두었다. 실험은 부위를 두개부, 복부, 골반부로 정하였고 Kerma는 몬테카를로 시뮬레이션을 기반으로 한 PCXMC 2.0로 측정하였다. 흡수선량은 다목적 선량계와 유리선량계로 측정하였다. 그 결과 PCXMC 2.0, 다목적 선량계, 유리선량계에서 두개부, 복부, 골반부 모두 PCXMC 2.0, 다목적 선량계, 유리선량계 순으로 선량 차이가 크게 났으며, 다목적 선량계는 Kerma에 더 가까운 값을 나타냈다. 결과적으로 실제 흡수선량 측정은 유리선량계가 가장 유리하다는 것을 알 수 있었다.

RALS에 장착한 Ir-192 선원의 강도측정에 대한 고찰 (Calibration of an $^{192}Ir$ Source Used for High Dose Rate RALS.)

  • 문언철
    • 대한방사선치료학회지
    • /
    • 제6권1호
    • /
    • pp.56-60
    • /
    • 1994
  • In the past, brachytherapy was carried out mostly with radium or radon sources. Currently. use of artificially produced radionuclially produced radionuclides such as $^{137}Cs,\;^{192}Ir,\;^{198}Au,\;and\;^{125}I$ is rapidly increasing. Although electrons are often used as an alternative to interstitial implants, brachytherapy continues to remain an important mode of therapy, either alone or combined with external beam. The National Council on Radiation Protection and Measurements(NCRP) recommends that the strength of any ${\gamma}$ emitter should be specified directly in terms of exposure rate in air at a specified distance such as 1m. The air kerma strength is defined as the product of air kerma rate in 'free space' and the square of the disrance of the calibration point from the source center along the perpendicular bisector, i. e., $S_k=K_L{\times}L^2$. Where $S_K$ is the the air kerma strength and K is the air kerma rate at a specified distance L. (usually 1m). Recommended units for all kerma strength are ${\mu}Gym^{2}h^{-1}$.

  • PDF

Fast Low Dose C-arm CT와 DSA의 선량 비교 (Dose Comparison between Fast Low Dose C-arm CT and DSA)

  • 김찬우;김재석
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.613-618
    • /
    • 2020
  • 간동맥화학색전술 중 사용되고 있는 Fast Low Dose C-arm CT의 평균선량을 DSA의 평균선량과 비교해 보고, 전체 누적선량에서 검사기법별 평균선량 분석을 통해 피폭선량을 분석해 보았다. 본원에서 환자 50명을 임의로 선정하여 Fast Low Dose C-arm CT와 DSA의 DAP 및 Air Kerma를 조사하여 비교하였으며, 4가지 검사기법(DSA, Fast Low Dose C-arm CT, Roadmap, Fluoroscopy)의 누적선량(DAP, Air Kerma)이 차지하는 비율을 분석하였다. 통계적인 비교 분석을 위해 통계프로그램 SPSS 20.0을 이용하여 대응표본 T검정, ANOVA 검증(post hoc test : Tukey)하였다. Fast Low Dose C-arm CT가 DSA에 비해 평균선량(DAP, Air Kerma)이 통계적으로 유의하게 낮았다.(p<.001) 간동맥화학색전술에서 항암제 주입 전후로 Fast Low Dose C-arm CT를 적극 활용하여 DSA의 검사 횟수를 줄인다면 환자의 의료방사선 피폭을 감소시킬 수 있다.

방사선촬영에서 면적선량 및 새로운 실질면적선량 개념의 비교 평가 (Comparative Evaluation of Kerma Area Product and New Fundamental of Kerma Area Product on Radiography)

  • 최우철;김용민;김정수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권1호
    • /
    • pp.53-58
    • /
    • 2021
  • Kerma Area Product (KAP) is best indicator of radiation monitoring on radiographic examinations. KAP can be measured differently depending on the X-ray irradiation area, air kerma, souce-skin distance, type of equipment, etc. The major factors are exposure area and the air krema. The KAP currently used only considers the exposure area with X-rays and has a problem that KAP is always excessively overestimated from the dose received by an actual subject. Therefore, in this study, in order to measure the accurate KAP, a new area dose calculation that can be calculated by dividing the area where the actual X-ray is irradiated is presented, and the KAP is the real area. We compared and analyzed how much it was overestimated compared to the dose. The Skull AP projection and seven other projection were compared and analyzed, and the KAP was overestimated in each test by 52% to 60%. In this way, the effective KAP (EKAP) calculation developed through this study should be utilized to prevent extra calculation of the existing KAP, and only the accurate patient subject area should be calculated to derive the accurate area dose value. EKAP is helpful for control the patient's exposure dose more finely, and it is useful for the quality control of medical radiation exposure.

Ir-192 고선량률 선원에 대한 공기커마강도의 품질보증 (Quality Assurance of Air Kerma Strength for Ir-192 High Dose Rate Source)

  • 김종언;윤천실;김성현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권2호
    • /
    • pp.147-151
    • /
    • 2007
  • AAPM TG43 프로토콜에서 선원 강도의 측정은 공기커마강도로 권고하고 있다. 본 연구는 제조사에서 제공되는 공기커마강도의 정확성이 ${\pm}5%$ 범위 이내에 있는지 측정으로 검증하는데 목적이 있다. Standard imaging사의 MAX-4001 Electrometer와 HDR 1000 Plus, 그리고 6 french bronchial Applicator를 재료로 사용하여, 이온함의 중심축의 바닥으로부터 10 mm 지점에서 90 mm 지점까지 이온화 전류를 측정하였다. 측정된 이온화 전류 곡선에서 최대 이온화 전류를 나타내는 거리를 교정의 기준점으로 정하고, 이 이온화 전류 측정치로부터 공기커마강도를 구하였다. 이온화 전류 곡선의 정점인 최대 이온화 전류에 대응하는 거리는 50 mm이었다. 이 거리는 UW-ADCL의 교정 검증서의 선원의 기준점과 완전히 일치하였다. 측정으로 계산된 공기커마강도는 제조사에서 제공된 교정치보다 약 0.5% 더 높게 측정되었다. 제조사에서 제공되는 교정 검증서의 공기커마강도는 신뢰할 수 있는 정확성을 가졌다는 결과를 얻었다. 측정에서 우물형 이온함 안의 dead space의 길이와 선원의 dwell position으로 이동 오차 그리고 산란선의 영향 등을 고려하면, 정확한 측정과 교정의 결과를 얻을 수 있다고 생각된다.

  • PDF

Airborne HPGe spectrometer for monitoring of air dose rates and surface activities

  • Marcel Ohera;Lubomir Gryc;Irena Cespirova;Jan Helebrant;Lukas Skala
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4039-4047
    • /
    • 2023
  • This contribution describes the application of HPGe detector for the airborne quantitative analysis. The hardware of the airborne HPGe system was designed from the commercial components with only exception of the newly designed AirHPGeSpec special software to control, measure and process the data. The system was calibrated for the local air kerma rates measured on helicopter board and its conversion to the air kerma rates at 1 m above the ground was proposed. Two examples of the air kerma rates measured over the former uranium mining areas are presented and compared with the results of other airborne system on the board. This airborne HPGe system could be also used for measuring the surface activities in a radiation event. The nuclides of 131I, 132Te - 132I, 133I, 134I, 135I, 137Cs, 134Cs, 88Rb and 103Ru were selected from possible nuclear power plant emergency scenarios. The Monte Carlo simulation was used to calculate HPGe detector efficiencies for the flight altitudes from 25 to 300 m for the energies from 300 keV to 3 MeV of the nuclides in question. Also, the detection limits according to the Currie method as well as ISO 11929-2010 for selected nuclides are presented.

Region-wise evaluation of gamma-ray exposure dose in decontamination operation after a nuclear accident

  • Jeong, Hae Sun;Hwang, Won Tae;Han, Moon Hee;Kim, Eun Han;Lee, Jo Eun;Lee, Cheol Woo
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2652-2660
    • /
    • 2021
  • The gamma-ray exposure doses in decontamination operation after a nuclear accident were evaluated with a consideration of various geometrical conditions and specific gamma-ray energies. The calculation domain is organized with three residence types and each form is divided into two kinds of geometrical arrangements. The position-wise air KERMA values were calculated with an assumption of evenly distributed gamma-ray source based on Monte Carlo radiation transport analysis using the MCNP code. The radioactivity is initially set to be unity to be multiplied by the deposition value measured in the actual accident condition. The workforce data set depending on the target object was determined by modifying the Fukushima report. The external exposure doses for decontamination workers were derived from the calculated KERMA values and the workforce analysis. These results can be used to efficiently determine the workforce required by the characteristics of the area and the structure to be decontaminated within the dose limits.

진단용 DR 발생장치에서 IEC 표준규격과 상용부하의 공기커마 직선성에 대한 일관성 비교 (Consistent Comparison for The Linearity Air Kerma of IEC Standards and Commercial Load in Diagnosing DR Generators)

  • 한범희;김종일;이상호;한상현;유인규
    • 한국방사선학회논문지
    • /
    • 제6권5호
    • /
    • pp.389-394
    • /
    • 2012
  • 본 연구에서는 IEC 60601-2-54에서 제시한 표준을 근거로 부하조건에서의 제한된 간격으로 걸친 공기커마를 절대측정하여 X선의 직선성을 면밀히 평가하여 다음과 같은 결과를 얻었다. 10대를 대상으로 한 모든 진단용 X선 발생장치(DR)는 IEC 60601-2-54 표준에서 제시한 공기커마의 직선성이 부적합으로 나타났고, 일반적인 조사선량의 직선성 평가방법에서는 4대에서 최고 관전압의 50%와 80%의 두 개 측정 계열 모두 부적합으로 나타났으며, 나머지 6대에서는 최고 관전압의 50%와 80%의 두 개 측정 계열 모두에서 적합으로 나타났다. IEC 60601-2-54 표준에서 제시한 직선성 시험과 기존의 조사선량 직선성 시험이 많은 차이를 보였다. IEC 60601-2-54 표준+에서 제시한 공기커마의 직선성은 국제표준의 권고사항이므로 기존의 조사선량 직선성 보다 상당히 타당성이 있고, 방사선량을 정량화하기 위한 표준으로 IEC 60601-2-54 표준에서 제시한 공기커마의 직선성이 진단용 X선 영상장치 성능관리에 중요한 평가 요소라 사료된다.