• 제목/요약/키워드: KEPCO Power System

검색결과 1,269건 처리시간 0.033초

극저온 정제시스템의 품질관리를 위한 SF6 가스 분석방법 개선 (Improved sulfur hexafluoride(SF6) gas analysis method for quality management of cryogenic refinement system)

  • 이정은;조민;이원석
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권1호
    • /
    • pp.37-41
    • /
    • 2022
  • Because sulfur hexafluoride(SF6) is classified as one of the six major greenhouse gases, SF6 handling in power plant such as recovery, purification, and reuse is considered to be important. KEPCO has focused to develop the advanced recovery and purification technology of SF6 reuse. SF6 analysis includes the on-site analyses and on-line analyzer; i.e., (1) on-site analysis has an error rate of ±0.5% and (2) on-line analysis has an error rate of ±0.1%, which is possible to adjust operating conditions and to make the work more conveniently by analyzing SF6 concentration before and after purification step. This paper presents an online analysis method in the SF6 purification and reuse system. In addition, the analysis results and quality guarantees for each section of the analysis system were presented.

확률론적 공급신뢰도 평가를 위한 전압레벨별 데이터베이스 구축방안 (Construction of Database for Reliability Evaluation of the Large Power System)

  • 문승필;신태우;장병훈;전동훈;곽희섭;한경남;최재석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.74-75
    • /
    • 2006
  • The reliability evaluation methods for the bulk power system habe been studied by several electric utilities. The evaluation methods based on the probability theory and the computer packages are being developed or already practicalized. But without correct probabilistic data, accurate result couldn't be expected. In this point, the construction of database is needed. Some of probabilistic data for evaluation of bulk power system are shown in this paper.

  • PDF

Analysis of Voltage Regulation by DSTATCOM - Using the EMTDC Program

  • Jeon Young-Soo;Kwak No-Hong;Choo Jin-Boo
    • Journal of Power Electronics
    • /
    • 제5권4호
    • /
    • pp.329-334
    • /
    • 2005
  • The DSTATCOM(Distribution Static Synchronous Compensator) is one of the Custom Power Devices that can regulate voltage. The DSTATCOM operates as a shunt connected static var compensator whose capacitive or inductive output current can be controlled independent of the system voltage. The magnitude of the compensated voltage is limited by characteristics of the system and the load. Compensation capability of the DSTATCOM which can inject 1 MVAR reactive power was simulated by EMTDC under several conditions. This paper analyzes the effect of the DSTATCOM's compensation considering the length and kind of distribution line, the power factor and magnitude of the load, and the duration and magnitude of the voltage variation.

국내 계통의 단기 전압 안정도에 대한 부하 모델의 영향성 검토 및 부하 모델 파라미터 선정 (Impact of Dynamic Load Model on Short-Term Voltage Stability of Korea Power System and Estimation of Dynamic Load Model Parameters)

  • 문재민;김재경;허견;남수철;김용학
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권1호
    • /
    • pp.17-24
    • /
    • 2019
  • 본 논문은 전력계통의 부하 모델이 단기 전압 안정도 해석 결과에 미치는 영향을 분석하였다. 우선, 본 논문에서는 일반적으로 많이 사용되는 부하 모델을 소개하였고, 일부 부하 모델은 모델 파라미터를 최적화하더라도 실제 측정된 계통 현상을 재현할 수 없다는 것을 확인하였다. 또한, 본 논문에서는 상정사고 상황을 고려하여 국내 전력계통의 단기 전압 안정도 해석 시 부하 모델의 영향과 지역별 부하 모델의 영향성을 검토하였다. 해당 결과를 통해 부하 모델 선정의 중요성을 재차 확인할 수 있었으며, 상정사고 인근 지역의 부하 특성을 보다 더 정확하게 반영해야 함을 알 수 있다.

Comparative Analysis of 10 MW Superconducting Wind Power Generators with Three-phase and Nine-phase Armature Windings

  • Kim, Taewon;Woo, Sang-Kyun;Sung, Hae-Jin
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권4호
    • /
    • pp.343-347
    • /
    • 2019
  • When referring to weight, volume, and efficiency, a SuperConducting Synchronous Generator (SCSG) is definitely superior to conventional generators as a large-scale wind power generation system. The SCSG is connected to a full power converter that transmits the energy from the SCSG to the power grid. To reduce the current stress and system cost, the SCSG which has nine-phase armature windings with three converters is used. This paper deals with a comparative analysis of 10 MW superconducting wind power generators with three-phase and nine-phase armature windings. The stator windings of SCSGs are of various types. Using the finite element method, SCSGs are analyzed and compared in terms of the weight and volume of SCSGs, the total length of the superconducting wire, harmonics, torque performance, and efficiency. The analyzed results will be effectively utilized to design large-scale superconducting generators for wind power generation systems.

풍력발전단지가 도입되는 한전 실배전계통의 전압변동에 대한 분석 (A Study on Voltage Variation in KEPCO Distribution System by Introducing the Wind Power Plant)

  • 황진수;정원재;강성수;김병숙;강흥식;김재언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.16-18
    • /
    • 2001
  • Recently, a study on operation in parallel between Distributed Generation(DG) unit and power distribution system has been growing interest in power distribution system. But, introducing the DG unit causes the problem due to rising the voltage variation on power distribution system. So, This paper presents the effect of introducing DG unit on distribution system. For this simulation, KEPCO distribution system is used.

  • PDF

디지털 TRS를 이용한 배전자동화통신망 구축 방안 (Design of the digital TRS network for for the Distribution Automation System)

  • 김태경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.420_421
    • /
    • 2009
  • The digital TRS(Trunked Radio System) is an excellent alternative for the transmission medium for the DAS(Distribution Automation System). KEPCO(Korea Electric Power Corporation) made the power IT network with digital TRS system. The main function of the radio network is transmitting and receiving information for the DAS. KEPCO's digital TRS is based on TETRA standard. The digital TRS supports data communication for the electric power control and monitoring systems in various ways.

  • PDF

Study on Application of Reinforcement Device to Provide Greater Dynamic Stability for Power Transmission Towers and its Effect

  • Yang, Kyeong-hyeon;Bae, Choon-hee;Jeong, Nam-geun;Kim, Doo-young;Kim, Sung-min;Jang, Yong-hee
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권1호
    • /
    • pp.33-41
    • /
    • 2016
  • To verify that the friction damper used to high buildings as a kind of control technology of wind vibration can reduce dynamic behaviors of PTTs effectively, slip dampers in this paper are proposed to absorb the energy through relatively frictional movement of slip dampers applied to main post of a PTT (Power Transmission Tower) when dynamic displacement of a PTT occurs. The result of dynamic analysis is presented to determine the capacity of the damper system by controlling damping ratio on the resonance condition. It is observed that by installing slip dampers at a PTT the strain amplitudes of the main post caused by wind load are effectively reduced. Therefore it is shown that the proposed damper satisfies the strengthened wind-load design standards, and its efficacy was also validated experimentally by field testing.

전력설비의 수명계산을 위한 통계적 분석기법의 활용 및 검증에 대한 연구 (A Study on the Application and Verification of Statistical Techniques for Calculating the Life of Electric Power Facilities)

  • 이온유;김강식;이홍석;조종은;김상봉;박기훈
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권1호
    • /
    • pp.9-14
    • /
    • 2022
  • Social infrastructure facilities such as production, transportation, gas and electricity facilities may experience poor performance depending on time, load, temperature, etc. and may require maintenance, repair and management as they are used. In particular, in the case of transformers, the process of managing them for the purpose of preventing them from failing is necessary because a failure can cause enormous social damage. The management of transformers should consider both technical and economic aspects and strategic aspects at the same time. Thus, it applies the Asset Management concept, which is widely used in the financial industry as an advanced method of transformer management techniques worldwide. In this paper, the operation and power outage data were secured for the asset management of the transformer for distribution, and the asset status was analyzed. Analysis of asset status using actual operation and power outage data is essential for assessing the statistical life and failure rate of the facility. Through this paper, the status of transformer assets for arbitrary A group distribution was analyzed, and the end of life and replacement life were calculated.

우리나라 전력계통의 물리적 및 운영 측면에서의 공급 여유력 평가 (Physical and Operational Supply Margin Evaluation of KOREA Power System)

  • 권중지;정상헌;사박;트란트룽틴;최재석;차준민;윤용태
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.18-27
    • /
    • 2007
  • Successful operation of power system under regulated as well as deregulated electricity markets is very important. This paper presents marginal power flow evaluation of KEPCO system in view point of physical and operation mode by using Physical and Operational Margins (POM Ver.2.2), which is developed by V&R Energy System Research. This paper introduces feature and operation mode of POM Ver.2.2 and then evaluates scenarios of 6 lines contingencies of 765kv of KEPCO system at peak load time on summer in 2006 you. The case study for actual 2006 year KEPCO system shows that this POM program is applicable sufficiently to KEPCO system. Futhermore, it demonstrates that it is helpful for operator's operating the system successfully by evaluating physical and operational margins quickly for various contingencies occurred in KEPCO system. Eventually, it will assist operators to operate more reliably the KEPCO system in future.