• 제목/요약/키워드: KEPCO Grid

검색결과 214건 처리시간 0.036초

경수로 핵연료집합체 진동의 실험적 고찰 (An Experimental Study on PWR Nuclear Fuel Assembly Vibration)

  • 장영기;김규태;조규종
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.82-87
    • /
    • 2003
  • Nuclear fuel with a big slenderness ratio is susceptible to flow-induced vibration under very severe conditions of high temperature, high flow and exposure to irradiation in nuclear reactor. The fuel assembly should, therefore, be designed to escape any resonance due to the vibration during the reactor operation, in particular, in case of the design changes. In addition, the amplitudes due to the grid vibration, the fuel rod vibration and the fuel assembly vibration should be minimized to reduce the grid-to-rod fretting wear. Fuel assembly vibration tests in air at room temperature and in water at high temperature have been performed to investigate fuel vibration behaviors. The frequency and damping during the test in air have been compared to those in water. Through the hydraulic test, the advanced assembly has been evaluated not to be susceptible to any resonance. In addition, the test data from the tests can be used to make fuel model and to evaluate grid-to-rod fretting wear.

  • PDF

Effects of house load operation on PSA based on operational experiences in Korea

  • Lim, Hak Kyu;Park, Jong-hoon
    • Nuclear Engineering and Technology
    • /
    • 제52권12호
    • /
    • pp.2812-2820
    • /
    • 2020
  • House load operation (HLO) occurs when the generator supplies power to the house load without triggering reactor trips during grid disturbances. In Korea, the HLO capability of optimized power reactor 1000 (OPR1000) plants has prevented several reactor trips. Operational experiences demonstrate the difference in the reactor trip incidence due to grid disturbances between OPR1000 plants and Westinghouse plants in Korea, attributable to the availability of the HLO capability. However, probabilistic safety assessments (PSAs) for OPR1000 plants have not considered their specific design features in the initiating event analyses. In an at-power PSA, the HLO capability can affect the initiating event frequencies of general transients (GTRN) and loss of offsite power (LOOP), resulting from transients within the grid system. The initiating event frequencies of GTRN and LOOP for an OPR1000 plant are reduced by 17.7% and 78.7%, respectively, compared to the Korean industry-average initiating event frequencies, and its core damage frequency from internal events is reduced by 15.2%. The explicit consideration of the HLO capability in initiating event analyses makes significant changes in the risk contributions of the initiating events. Consequently, for more realistic at-power PSAs in Korea, we recommend incorporating plant-specific HLO-related design features when estimating initiating event frequencies.

이천 초전도시범사업관련 22.9kV 초전도 케이블 실계통 적용을 위한 열동계전기 검토 (Thermal Protection Study on 22.9kV HTS Power Cable for Applying to Real Grid)

  • 양병모;강지원;장태인;박진우;조흥상;김태훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.499-500
    • /
    • 2011
  • 국내전력수요의 지속적인 성장과 더불어 전력산업의 대용량화, 고밀도화에 따른 친환경 고신뢰도의 전력계통 구성을 위하여 친환경 녹색기술의 초전도케이블이 실증시험을 통한 실계통 적용 사업이 이천변전소에서 정부지원으로 한전전력공사 주관으로 진행되고 있다. 그래서 향후 초전도 케이블이 실계통에 연계한 계통이 운용되는 것을 고려해야 하기 때문에 기존 전력기기와 협조하여 운영되기 위해서는 계통영향 분석이 필요하다. 특히 초전도케이블은 초전도성이라는 물리적인 특성 때문에 기존 계통해석과정과는 다른 계통 과도현상의 모델링이 필요하다. 따라서 본 논문에서는 초전도케이블의 실계통 적용을 위해서 이천변전소에 시범 적용된 22.9kV 50MVA 500m 초전도케이블 계통을 대상으로 열적특성을 분석하고 안정적인 대규모 전력전송을 위해서 초전도 케이블을 열적특성으로부터 보호하기 위한 열동계전기(Thermal Protection Relay)의 운영방법과 적용방안을 소개하고자 한다. 향후 대용량 초전도케이블의 실계통 적용 확대를 고려한 열동계전기의 운영방법과 적용방안도 제시하고자 한다.

  • PDF

스마트그리드 통신망 구축 및 운영방안 연구 (Study on Construction and operation of the Smart Grid Communication Network)

  • 양호욱;황우현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.139-140
    • /
    • 2011
  • 스마트그리드 통신망은 발전, 송전, 배전, 소비자 등의 각 도메인들이 상호운영성을 확보할 수 있도록 시스템과 시스템, 시스템과 단말, 단말과 단말간에 유무선 통합통신망을 구축하는 것이다. 현재 제주도 실증단지 스마트그리드 통신망은 기존 송전선로 OPGW와 4개 배전선로에 첨가 광케이블을 이용하여 각 시스템이 연계될 수 있도록 구축했다. 이에 현재 설치된 현황을 살펴보고 미래 스마트그리드로 가기 위한 통신망 구축과 운영방안을 제시하고자 한다.

  • PDF

전력자동화 통신망 인프라를 이용한 네트워크 서비스 최적 구축 방안 (Optimal design of the network service for the Electric Power Automation IT Infra.)

  • 박수환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.730-731
    • /
    • 2011
  • EPA(Electric Power Automation IT Infra) is a System for Protective Information Transmitter & Receiver and network service. KEPCO(Korea Electric Power Corporation) is building up a high-speed communication network to accept Smart Grid Infra expansion and various terminal communication media characteristic. Recently, MSPP(Multi Service Provisioning Platform) System is establishted to network service. But there are many considerations for optimal design of network service for the Electric Power Automation IT Infra.

  • PDF

LSTM을 활용한 풍력발전예측에 영향을 미치는 요인분석 (Analysis on Factors Influencing on Wind Power Generation Using LSTM)

  • 이송근;최준영
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권4호
    • /
    • pp.433-438
    • /
    • 2020
  • Accurate forecasting of wind power is important for grid operation. Wind power has intermittent and nonlinear characteristics, which increases the uncertainty in wind power generation. In order to accurately predict wind power generation with high uncertainty, it is necessary to analyze the factors affecting wind power generation. In this paper, 6 factors out of 11 are selected for more accurate wind power generation forecast. These are wind speed, sine value of wind direction, cosine value of wind direction, local pressure, ground temperature, and history data of wind power generated.

Development and Test of a Cooling System for a 154 kV Superconducting Fault Current Limiter

  • Kim, Heesun;Han, Young Hee;Yang, Seong-Eun;Yu, Seung-Duck;Park, Byung Jun;Park, Kijun;Yoo, Jaeun;Kim, Hye-Rim;In, Sehwan;Hong, Yong Joo;Yeom, Hankil
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제1권1호
    • /
    • pp.141-144
    • /
    • 2015
  • The superconducting fault current limiter (SFCL) is an electric power device that limits the fault current immediately in a power grid. Korea Electric Power Corporation (KEPCO) has been developing a 154 kV, 2 kA SFCL since 2011 to protect power grids from increasing fault current and improve the stability and quality of electric power. This SFCL adopts 2G YBCO wires and operates at 71 K and 5 bars. In this paper, a cooling system for the 154 kV SFCL and its cooling test results are reported. This cooling system uses a Stirling-type cooler to make sub-cooled liquid nitrogen ($LN_2$), which cools the superconductor modules of the SFCL. The $LN_2$ is circulated between the cooler and the cryostat that contains superconductor modules. The $LN_2$ also plays the role of a high voltage insulator between the modules and the cryostat, so the pressure was maintained at 5 bars for high insulation performance. After installation in a test site, the cooling characteristics of the system were tested. In this operation test, some important data were measured such as temperature distribution in $LN_2$, pressure change, performance of the heat exchanger, and cooling capacity of the total system. Consequently, the results indicate that the cooling system operates well as designed.

에너지 저장장치용 슈퍼커패시터 이온 도핑 제어를 통한 에너지 밀도 향상 연구 (Improvement of Energy Density in Supercapacitor by Ion Doping Control for Energy Storage System)

  • 박병준;유선미;양성은;한상철;노태무;이영희;한영희
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권3호
    • /
    • pp.209-213
    • /
    • 2019
  • 최근 전력 계통에 사용되는 주파수 조정용(F/R) 에너지 저장장치에 대하여 높은 에너지 밀도와 장수명의 안정성에 대한 요구가 증대되고 있다. 이와 관련하여 슈퍼커패시터는 장수명과 급속 충방전 특성이 우수하므로 이러한 F/R 적용을 위한 에너지 저장장치로 적합하게 여겨지고 있다. 슈퍼커패시터는 단주기 F/R 영역의 보완 운전을 담당하고 전력계통에 설치된 ESS의 장주기 운영 수명을 연장함으로써 기존 용량을 담당하는 리튬 배터리의 설치 규모와 양을 획기적으로 줄일 수 있다. 하지만 낮은 에너지 밀도는 전력 계통과 같은 큰 시스템에서 적용에 한계가 있으며 여전히 배터리를 대체할 수 있는 높은 에너지 밀도 요구에 어려움을 겪고 있다. 그러나 최근에는 리튬이온 커패시터(Lithium ion capacitor; LIC) 구조가 3.8 V 이상의 전압 구간을 구현할 수 있기 때문에 전기이중층 커패시터(Electric double layer capacitor; EDLC) 구조보다 고에너지 밀도 구현을 위한 구조로 각광을 받고 있지만 여전히 상용화를 위해서는 여러가지 전기화학적 성능에 대한 구체적인 검증 및 개발이 필요한 실정이다. 본 연구에서는 LIC의 에너지 밀도와 관계되는 용량을 증대하기 위하여 새로운 전극사전-도핑 방법을 설계하였다. 양극 활물질은 0.1% 이하의 상대습도 분위기 드라이룸에서 기계적 강도와 음극 도핑을 안정되게 수행될 수 있도록 $100{\mu}m$의 두께로 제작되었다. 또한 접촉 저항을 최소화하기 위하여 제조된 전극은 상온에서 $65^{\circ}C$까지 열 압축공정을 실시하였다. 최종적으로 LIC 구조에 대한 다양한 사전-도핑법을 설계하고 그 메커니즘을 분석하여 용량과 전기화학적 안정성이 향상된 새로운 LIC 사전-도핑 방법을 제안하였다.

매설 배관 피복 결함 탐상 정확도에 미치는 인접 정류기 및 접지 구리망 간섭의 영향 (Effects of Rectifier and Copper Grid Interference on the Detection Reliability of Coating Flaws on Buried Pipes)

  • 김민기;임부택;김기태;장현영;박흥배;김영식
    • Corrosion Science and Technology
    • /
    • 제19권4호
    • /
    • pp.211-223
    • /
    • 2020
  • The external corrosion of buried piping can be controlled using both coating and cathodic protection. Several factors are involved in the damage and deterioration of the coating on pipes. There are many detection methods for coating defects on pipes and the direct current voltage gradient (DCVG) method is one of the most powerful methods. However, the detection reliability of DCVG can be affected by interferences such as stray current, metal objects connected to rectifiers, and copper grids. Therefore, this study focused on the interference effects of rectifiers and a copper grid on the reliability of coating flaw detection. As the length of the interference pipe connected to the rectifier increased, the reliability decreased. In contrast, as the distance between the pipe and the copper grid increased, the reliability of the coating flaw detection increased. The detection results produced by the DCVG method were discussed using current and potential simulations for a pipe with a rectifier and copper grid interference in the soil.

스마트 그리드 환경의 통합 플랫폼 구현을 위한 기술현황 및 전망 (The Technical Trend and Prospect of Platform Integration for Smart Grid System)

  • 최승환;오도은;김영일;김영준;강신재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1977-1978
    • /
    • 2011
  • 스마트그리드는 기존의 전력망에 정보통신 기술을 융합하여 공급자와 소비자가 양방향으로 실시간 전력 정보를 교환함으로써 에너지 효율을 최적화 하고자 하는 차세대 전력망이다. 기존의 공급자 중심의 일방향성, 폐쇄성, 획일적인 전력망에서 수요자 중심의 양방향성, 개방성을 특징으로 하며 다양한 서비스를 제공하게 된다. 스마트그리드의 운영환경에서의 비즈니스 모델에 따라 기존 서비스 플랫폼과 신규 서비스 플랫폼을 융합할 수 있는 정보통합 체계가 구축되어야 한다. 또한 이종 플랫폼을 융합할 수 있는 적응 모듈이 체계적으로 설계되어야 하며, 이종 체계간 상호운용성 확보는 필수사항이다. 한편 우리나라는 기후변화 등 범 세계적인 이슈에 대응하기 위하여 저탄소 녹색성장, 에너지 효율향상 및 신성장 동력 창출을 위하여 국가 전략 로드맵을 수립하고 국가 단위의 실증사업을 통한 선제적 대응에 총력을 다하고 있다. 실제로 국가 로드맵과 실증사업은 지능형 전력망, 지능형 소비자, 지능형 운송, 지능형 신재생, 지능형 전력서비스의 5개 분야의 응용서비스 영역 기반으로 나누어져 각각의 서비스 플랫폼 구조를 가지고 있으며, 이에 대한 스마트그리드 플랫폼 통합 체계 기술은 스마트그리드의 핵심 기술이다.

  • PDF