• Title/Summary/Keyword: KEPCO

Search Result 3,426, Processing Time 0.043 seconds

Technical and Economic Assessment of CO2 Transportation Options for Large-scale Integrated Carbon Capture & Sequestration(CCS) Project in South Korea

  • Lee, Ji Hyun;Kim, Beom-Ju;Kwak, No Sang;Shim, Jae-Goo;Shin, Su Hyun;Hwang, Sun-Na;Lee, Jung-Hyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.1
    • /
    • pp.49-56
    • /
    • 2017
  • In order to examine the feasibility of Carbon Capture & Sequestration, a major technological strategy for the national goal of greenhouse gas reduction, this paper studies the various methods and corresponding costs for the transportation of $CO_2$ captured at the domestic thermal power plants, as well as performing comparative analysis with overseas CCS demonstration projects. It is predicted that the investment cost would be about 98 million USD when the using land-based pipelines to transport captured $CO_2$ from the thermal power plant located in the south coast. And using marine-based offshore pipelines, it will cost about twice the amount. When the captured $CO_2$ is transported from the power plant in the west coast instead, the cost is expected to increase substantially due to the transportation distance to the storage site being more than double to that of the south coast power plant case.

Investigation on Effective Operational Temperature of HTS Cable System considering Critical Current and AC loss

  • Kim, Tae-Min;Yim, Seong-Woo;Sohn, Song-Ho;Lim, Ji-Hyun;Han, Sang-Chul;Ryu, Kyung-Woo;Yang, Hyung-Suk
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.307-310
    • /
    • 2016
  • The operational cost for maintaining the superconductivity of high-temperature superconducting (HTS) cables needs to be reduced for feasible operation. It depends on factors such as AC loss and heat transfer from the outside. Effective operation requires design optimization and suitable operational conditions. Generally, it is known that critical currents increase and AC losses decrease as the operational temperature of liquid nitrogen ($LN_2$) is lowered. However, the cryo-cooler consumes more power to lower the temperature. To determine the effective operational temperature of the HTS cable while considering the critical current and AC loss, critical currents of the HTS cable conductor were measured under various temperature conditions using sub-cooled $LN_2$ by Stirling cryo-cooler. Next, AC losses were measured under the same conditions and their variations were analyzed. We used the results to select suitable operating conditions while considering the cryo-cooler's power consumption. We then recommended the effective operating temperature for the HTS cable system installed in an actual power grid in KEPCO's 154/22.9 kV transformer substation.

Drone Operation Scheme for Patrolling & Inspecting Power Transmission Lines and on Public Drone Road Construction (송전선로 드론 순시·정밀점검 운용 및 공공용 드론길 구축방안에 대한 연구)

  • Woo, Jung-Wook;Park, Joon-Young;Kim, Seok-Tae;Lee, Jae-Kyung;Ryu, Seo-Hyeon
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.3
    • /
    • pp.271-278
    • /
    • 2020
  • KEPCO Research Institute developed a GIS-based autopilot drone inspection system for electric power facilities and since its pilot application in 2017, it has been successfully used to detect defects in power transmission lines. This paper presents how to operate this system in the field of power line inspection. Power transmission lines are located in a wide variety of environments such as plains, mountains, river crossings, sea crossings, and industrial areas. Among these, some transmission lines are difficult for human workers to access because of their geographies and some should be checked more often due to their severe contamination. Considering these field conditions, we classified drone operation in two categories to increase its effectiveness and efficiency - patrol surveillance and detailed inspection tasks. This paper describes the detailed procedures of the two tasks above and their field application experiences. In addition, this paper newly proposes how to construct public drone roads by using the information of KEPCO's power transmission lines.

A Case of Immunoglobulin G4-Related Disease Presenting as a Pleural Mass

  • Kim, Dong Hyun;Koh, Kyu Han;Oh, Hyeon Sik;Kim, Se Joong;Kang, Sae Han;Jung, Byung Wook;Song, Jun Gyu;Cheon, Mi Ju;Yoon, Seon Bin;Park, Yong Won;Ko, Young Min;Lee, Seung Hyeun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.76 no.1
    • /
    • pp.38-41
    • /
    • 2014
  • Immunoglobulin G4 (IgG4)-related disease is a newly recognized condition characterized by fibroinflammatory lesions with dense lymphoplasmacytic infiltration, storiform-type fibrosis and obliterative phlebitis. The pathogenesis is not fully understood but multiple immune-mediated mechanisms are believed to contribute. This rare disease can involve various organs and pleural involvement is even rarer. We report a case of IgG4-related disease involving pleura. A 66-year-old man presented with cough and sputum production for a week. Chest radiography revealed consolidation and a pleural mass at right hemithorax. Treatment with antibiotics resolved the consolidation and respiratory symptoms disappeared, but the pleural mass was unchanged. Video-assisted thoracoscopic surgery was performed. Histopathology revealed dense lymphoplasmacytic infiltration and storiform fibrosis with numerous IgG4-bearing plasma cells. The serum IgG4 level was also elevated. Further examination ruled out the involvement of any other organ. The patient was discharged without further treatment and there is no evidence of recurrence to date.

Study to Application of Controlled Switching HVAC Circuit Breaker in KEPCO Grid (개폐제어형 초고압차단기의 해외적용사례와 한전계통 적용검토)

  • Oh, Seung-Ryle;Kwak, Joo-Sik;Jeong, Moon-Gyu;Han, Ki-Seon;Goo, Sun-Geun;Ju, Hyoung-Jun;Park, Min-Hae;Kim, Hyun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.433-434
    • /
    • 2015
  • Dictionary meaning of circuit-breaker is a mechanical switching device, capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time and breaking currents under specified abnormal circuit conditions such as those of short circuit. and it had been recognized as being operated simultaneously. Controlled Switching System(CSS), which is technology for individual pole operation, are widely used to reduce transient phenomenon, for example switching surges, inrush current, for a all switching cases and nowadays it have become and economical solution for a switching place. The conventional solution to these problem is the use of pre-insertion resistors of $520{\Omega}$. However, it is recognised that the cost for products and maintenance are expensive and this apparatus makes more complex the circuit-breaker mechanism. Korea Electric Power Cooperation (KEPCO) has been study for relevant CCS technology since pilot application in substation in 2003 and plan to apply the actual power grid in 2017. This paper deals with the investigation of international CCS operation status and preview for application in KEPCO power grid.

  • PDF

Development of AMI NMS (Network Management System) using SNMP for Network Monitoring of Meter Reading Devices (원격검침 설비의 네트워크 상태감시를 위한 SNMP 기반의 저압 AMI 망관리시스템 개발)

  • Kim, Young-Il;Park, So-Jeong;Kim, Young-Jun;Jung, Nam-Jun;Choi, Moon-Suk;Park, Byung-Seok
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.259-268
    • /
    • 2016
  • KEPCO installed AMI (Advanced Metering Infrastructure) metering system for low-voltage customers from 2008. AMI metering system of KEPCO has operated 2.55 million customers and will plan to operate 22 million customers until 2020. KEPCO developed AMI NMS (Network Management System) to operate the meter reading network efficiently. NMS monitors the network status of DCUs (Data Concentration Unit) and modems. NMS provides functionalities of data collection and analysis. It collects property data of network device, network topology information, communication performance information, fault information, and etc. It analyzes collected data and controls network devices by remote access. AMI NMS collects about 370 MIBs (Mangement Information Bases) using SNMP (Simple Network Management Protocol). This paper introduces main functionalities, designed context, and implemented service screen.

Development and Test of a Cooling System for a 154 kV Superconducting Fault Current Limiter

  • Kim, Heesun;Han, Young Hee;Yang, Seong-Eun;Yu, Seung-Duck;Park, Byung Jun;Park, Kijun;Yoo, Jaeun;Kim, Hye-Rim;In, Sehwan;Hong, Yong Joo;Yeom, Hankil
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.141-144
    • /
    • 2015
  • The superconducting fault current limiter (SFCL) is an electric power device that limits the fault current immediately in a power grid. Korea Electric Power Corporation (KEPCO) has been developing a 154 kV, 2 kA SFCL since 2011 to protect power grids from increasing fault current and improve the stability and quality of electric power. This SFCL adopts 2G YBCO wires and operates at 71 K and 5 bars. In this paper, a cooling system for the 154 kV SFCL and its cooling test results are reported. This cooling system uses a Stirling-type cooler to make sub-cooled liquid nitrogen ($LN_2$), which cools the superconductor modules of the SFCL. The $LN_2$ is circulated between the cooler and the cryostat that contains superconductor modules. The $LN_2$ also plays the role of a high voltage insulator between the modules and the cryostat, so the pressure was maintained at 5 bars for high insulation performance. After installation in a test site, the cooling characteristics of the system were tested. In this operation test, some important data were measured such as temperature distribution in $LN_2$, pressure change, performance of the heat exchanger, and cooling capacity of the total system. Consequently, the results indicate that the cooling system operates well as designed.

KEPCO's Overseas Transmission Business Strategy and Goals (한국전력의 송전분야 해외사업 진출전략과 과제)

  • Byun, Gang;Lee, Hyoung-Han;Min, Byeong-Wook;Yang, Joon-Cheol;Kim, Jong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.14-16
    • /
    • 2003
  • For four decades now KEPCO has experienced an incredible growth rate of over 10% per year in each year. This growth led to the fast development of new facilities, especially in the transmission systems field, and we also managed to gain an enormous amount of experience and technology in the construction and design. With this experience and technology we curbed the electricity demand. Experts now predict that we will enter a new phase in which our growth rate will stagnate and eventually level off. This isn't what KEPCO or any company wants. We are looking for continued growth. In the last decade KEPCO began selling its technology in the generation sector of the electricity business to overseas markets. Sales in the generation sector have been a great success. This decade marks another milestone for KEPCO as overseas sales in the transmission sector began. Our first project, "Myanmar Power System Development Study" and its subsequent successful completion gave us the ammunition necessary to expand in this line of business. This success has also given birth to this paper. KEPCO is still the People's company, but with a new vision. It now hopes to not only sustain a high growth level but to also increase the growth of domestic companies by sharing with them a piece of the proverbial pie, as it ventures forth to be a Global player on the international stage.

  • PDF

A study on the characteristic test of the grounding electrodes used in distribution lines (배전용 접지전극의 전극별.공중별 특성시험에 관한 연구)

  • Park, Sang-Man;Park, Jae-Duck;Kang, Moon-Ho;Choi, Jong-Kee;Park, Young-Keun;Shim, Keun-Bo
    • Proceedings of the KIEE Conference
    • /
    • 2005.05b
    • /
    • pp.54-56
    • /
    • 2005
  • On the overhead distribution lines, we generally use a copper rod as a grounding electrode. It is a economical metallic structure. Recently, many new electrodes have been developed and used in the distribution system of KEPCO. Before using new grounding electrode. we need to measure the performance of each electrode for comparative analysis. This report describes the characteristic test of the grounding electrodes used in KEPCO.

  • PDF

Study on IED Engineering Method based on IEC 61850 (IEC 61850 기반 IED 엔지니어링 기법에 관한 연구)

  • An, Yong-Ho;Kim, Yong-Hak;Jang, Byung-Tae;Lee, Nam-Ho;Han, Jeong-Yeol;Lee, You-Jin;Shim, Eung-Bo;Cho, Jin-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.778-779
    • /
    • 2011
  • Recently, IED engineering method in home and abroad require high ability of expert based on IEC 61850 since IED engineering has been carrying out based on text. In this paper, Proposed easy IED engineering method is able to provide best solution to without specialized knowledge about IEC 61850. Also, This paper deals with easy method in order to provide to accomplish using SLD(single line diagram) and SSD(system specification description) file based on SLD.

  • PDF