Korea Design Standard (KDS) will be updated with two major revisions on the assessment of wind load and performance-based wind design (PBWD). Major changes on the wind load assessment are the wind load factor and basic wind speed. Wind load factor in KDS is reduced from 1.3 to 1, and mean recurrence interval (MRI) for basic wind speed increases from 100 years to 500 years considering the reduction of wind load factor. Additional modification is made including pressure coefficient, torsional moment coefficient and spectrum, and aeroelastic instability. Combined effect of the updates of KDS code on the assessment of wind load is discussed with the case study on the specified sites and building. PBWD is newly added in KDS code to consider the cases with various target performance, vortex-induced vibration, aeroelastic instability, or inelastic behavior. Proposed methods and target performance for PBWD in KDS code are introduced.
For low-rise piloti-type buildings that suffered significant damage in the Pohang earthquake, the seismic performance of those designed by codes issued before and after the earthquake has been recently revised. This study started with the expectation that many of the requirements presented in the current codes may be excessive, and among them, the spacing of column stirrup could be relaxed. In particular, the recently revised design code of concrete structures for buildings, KDS 41 20 00, suggests that the column stirrup spacing is 1/2 of the minimum cross-sectional size or 200 mm, which is strengthened compared to KBC 2016, but relaxed than the current KDS, 41 17 00, which is 1/4 of the minimum size or 150 mm. As a result of the study, it was found that the target performance level was sufficiently satisfied by following the current standards and that it could be satisfied even if the relaxed spacing was followed. Therefore, the strict column stirrup spacing of KDS 41 17 00 could be relaxed if a wall other than core walls is recommended in the current guideline for the structural design of piloti-type buildings.
액상화 평가를 수행할 때 진동전단응력비(CSR)는 일반적으로 지반응답해석 또는 Seed & Idriss의 간편법을 수정한 방법을 통해 산정하고 있다. 본 연구에서는 진동전단응력비 산정방법의 적용성을 분석하기 위하여 1차원 등가선형 지반응답해석을 수행한 후 미연방도로국(FHWA), 일본도로협회(JRA), 국내설계기준(KDS) 등에서 제안한 방법을 적용하여 진동전단응력비를 산정하였다. 연구결과, 국내설계기준(KDS)으로 산정한 진동전단응력비가 해석 결과와 가장 큰 오차를 나타내었다. 그 이유는 국내설계기준의 경우 깊이에 따른 응력감소계수를 최대진동전단응력의 비가 아닌 최대지반가속도의 비로 정의하는 오류가 있기 때문이다.
각형강관 기둥에 콘크리트를 충전하여 사용하는 콘크리트충전 강관구조가 구조부재로 사용되면 기둥 부재의 내력과 변형 능력이 증가되어 높은 효율성을 가진 구조물 구현이 가능해 진다. 콘크리트충전 강관구조에 대한 국내의 설계 기준은 대한건축학회에서 2005년에 제정한 후, 2009년과 2016년에 각각 개정되었다. 연구 목적은 콘크리트충전 각형강관 단주를 대상으로 일축 압축실험을 실시하여 압축내력 및 변형능력에 주는 영향을 파악하고, 국내의 건축구조기준의 기준식을 검증하여 차후 수정 및 보완에 필요한 자료를 제공하는데 있다. 실험에서 강관은 냉간가공으로 제작된 각형강관을 사용하였고, 시험체는 강관의 폭두께비를 변수로 총 26개를 제작하여 중심 압축실험을 실시하였다. 실험결과 콘크리트충전 각형강관 단주의 압축내력과 변위관계 및 파괴모드를 얻었고, 실험결과를 분석하여 콘크리트의 충전효과와 폭두께비의 영향을 파악하였다. 충전된 콘크리트의 압축내력은 일축응력 상태보다 9%정도 증가하였는데, 이것은 차후 건축구조기준에 반영할 필요가 있다. 실험결과를 건축구조기준과 비교한 결과, 냉간가공된 각형강관의 경우 건축구조기준의 콤팩트단면 한계폭두께비 2.26은 다소 과대 평가하고 있기 때문에 수정이 필요하며, 보수적으로 보완한 계수 1.35로 제한하여 보다 더 안정적인 설계식을 제안하였다.
현행 내진설계 일반(KDS 17 10 00)에 따르면 내진설계 시 사용하는 입력지진파에 대한 기준이 명확히 제시되어 있고 실지진파에 대해서는 표준설계응답스펙트럼에 맞추어 보정하도록하고 있으나, 실지진파 선택에 따른 영향이 사전에 평가되지 않아 지진파 선택 시 어려움이 있다. 본 연구에서는 국내외에서 발생한 실지진파에 대하여 국내 설계기준이 제시하는 표준설계응답스펙트럼에 부합하도록 보정한 후, 수치해석을 통하여 필댐의 침하량 변화를 평가하였다. 그 결과 댐 하단에 작용하는 자유장 가속도의 영향보다 댐 마루에서의 최대가속도, 댐제체를 통한 증폭 특성등 제체 상부의 거동이 침하량에 가장 큰 영향을 미치는 것으로 나타났다. 또한, 동일한 표준설계응답스펙트럼으로 보정한 입력지진파일지라도 초기 실지진파와 댐 제체에서의 증폭 특성에 따라 침하량이 달리 평가될 수 있음을 확인하였다.
김해평야 퇴적층의 동적 특성을 결정하기 위해 6개의 위치에서 상시미동 수평-수직비(HVSR)법으로 지반 고유진동수(f0)를 도출하고 High frequency f-k방법과 Modified Spatial Autocorrelation 방법을 적용하여 상시미동 기반 표면파 분석을 수행하였다. 레일리파 분산곡선과 지반 고유진동수를 바탕으로 역해석을 실시하여 전단파 속도 주상도를 도출하였다. 분석 결과에 의하면 김해평야 퇴적층 지역은 1hz 이상의 진동수 대역에서 상당한 규모의 지반운동 증폭이 예상된다. 천부 퇴적층은 대체로 200m/s 내외의 전단파 속도를 보이고 60m~100m 사이의 깊이에서 기반암이 존재할 것으로 추정되며, 다수의 위치에서 천부 퇴적층과 기반암 사이에 Vs=400m/s 가량의 하성 퇴적층이 존재하는 것으로 나타났다. 역해석 결과를 바탕으로 김해평야 퇴적층의 전단파 속도-깊이 모델을 도출하였으며, 본 연구에 따르면 김해평야 퇴적층 지역에서 내진설계일반(KDS 17 10 00)의 S6지반에 해당하는 위치의 면적은 상당할 것으로 예상된다.
The damage to non-structural elements in buildings has been increasing due to earthquakes. In Korea, post-installed anchors produced overseas have been mainly used for seismic anchorage of non-structural components to structures. Recently, a new cast-in-place concrete insert anchor installed in concrete without drilling has been developed in Korea. In this paper, an experimental study was conducted to evaluate the tensile and shear strengths of the newly developed anchor under monotonic load. The failure modes of the tension specimens were divided into concrete breakout failure and steel failure, and all shear specimens showed steel failure. In both tension and shear, the maximum loads of specimens were greater than the nominal strengths predicted by the concrete design code (KDS 14 20 54). As a result, it is expected that the current code can also be used to calculate the strength of the developed cast-in anchor.
최신 내진설계기준 KDS 41 17 00에 비선형동적해석에 사용될 지반운동 선정 및 보정에 관한 절차가 반영되었으나 관련 문헌 부족으로 실무적 차원에서의 적용이 여전히 어려운 실정이다. 본 연구는 비선형동적해석 수행을 위한 지반운동을 선정하고 보정하기 위해 부지응답해석을 수행한 사례를 소개한다. 이에 근거하여, 현행 설계기준에 명기된 부지응답해석 관련 조항을 실무적용 차원에서 검토하였다. 그 결과 암반운동선정에 관한 설계조항이 지나치게 엄격하여 과도한 결과를 초래하는 것으로 나타났다. 이는 가속도 민감 구간을 포함한 관심주기범위를 지닌 저층 구조물일수록 더욱 부각되는 것으로 판단된다. 특히 표면지진파가 기준에 적합한 응답을 보였음에도 불구하고, 해석 전 절차의 암반운동선정과 관련된 조항으로 인해 해석 후 절차와 관계없이 지진파를 다시 선정 및 보정해야만 했다. 또한, 연약지반이거나 해당 지반에 강한 지진이 발생하는 경우에는 지반물성과 적절한 해석 기법을 올바르게 선정하기 위해 더욱 엄격한 조사가 선행되어야 한다고 판단된다. 지반물성과 해석기법에 관한 신뢰도가 조금이라도 문제가 있다면 설계용도로 사용하기에 부적합한 결과를 초래할 수 있기 때문이다.
In this study, alternative seismic force-resisting systems for plant structure supporting equipment were designed, and the seismic performance thereof was compared using nonlinear dynamic analysis. One alternative seismic force-resisting system was designed per the requirement for ordinary moment-resisting and concentrically braced frames but with a reduced base shear. The other seismic force-resisting system was designed by accommodating seismic details of intermediate and unique moment-resisting frames and special concentrically braced frames. Different plastic hinge models were applied to ordinary and ductile systems based on the validation using existing test results. The control model obtained by code-based flexible design and/or reduction of base shear did not satisfy the seismic performance objectives, but the alternative structural system did by strengthened panel zones and a reduced effective buckling length. The seismic force to equipment calculated from the nonlinear dynamic analysis was significantly lower than the equivalent static force of KDS 41 17 00. The comparison of design alternatives showed that the seismic performance required for a plant structure could be secured economically by using performance-based design and alternative seismic-force resisting systems adopting minimally modified seismic details.
국내 지진발생의 증가에 따라 구조물 간의 접합 및 비구조물과 구조물의 연결에 사용되는 앵커의 내진설계가 필요하다. 이 논문에서는 지진 발생으로 균열폭이 커지는 경우에도 인장성능을 발현할도록 개발된 내진용 스테인리스스틸 확장식 후설치 앵커의 인장실험을 수행하였다. 현장에서 주로 사용하는 앵커의 지름 중 12 mm와 20 mm 앵커를 사용하였다. 확장식 후설치앵커의 내진성능을 평가하기위해 비균열 콘크리트와 균열 콘크리트에서 실험을 수행하였고 실험 방법은 콘크리트용 앵커 설계법 및 예제집 2판(KCI, 2018)에 따라 수행하였다. 실험변수는 균열의 유무, 콘크리트 압축강도, 앵커의 묻힘깊이 3가지이다. 평가는 콘크리트용 앵커 설계법 및 예제집 2판(KCI, 2018)에 제시된 방법인 유효계수(kc)값에 5% 분위수 안전율을 적용한 특성강도(K5%)를 이용하여 평가하였다. 설계기준에서 정의된 콘크리트브레이크아웃파괴를 위한 특성강도(K5%)는 비균열과 균열콘크리트에서 각각 9.8과 7.0 이다. 실험군에서 설계기준보다 높은 특성강도(K5%)가 발현되어 이 값을 콘크리트브레이크아웃강도로 사용할 수 있다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.