Journal of the Korea Institute of Military Science and Technology
/
v.9
no.2
s.25
/
pp.42-52
/
2006
Tube erosion can be defined as a phenomenon for an increment of bore diameter, a declination of accuracy and utility of tube by firing. This study introduces the characteristics of tube life for the 155 mm K9 SHP Using a tube history book with bore measurement data and firing data of standard charge, this study analyzed the EFC vs Tube life and EFC with heat transfer effect formula as a consideration of continuous firing vs tube life. The results were compared with Firing Table(FT 155-K9-1) after the analysis. Also, this study suggests that CN98 tube can be rifled as 1000 EFC through the severe condition with continuous firing.
Joo, Geunsu;Huh, Hoon;Jung, Yeong Hyuk;Kim, Ju Yeong;Seo, Songwon
Transactions of the Korean Society of Mechanical Engineers A
/
v.41
no.9
/
pp.877-885
/
2017
This paper is concerned with numerical simulation of a gun-launched projectile considering a rifled gun-tube. Gun-launched conditions induce dynamic behaviors, such as high pressure and high speed rotation. A projectile and its internal electronic components may be damaged in such harsh environments. Hence, it is necessary to perform numerical simulation of a gun-launched projectile to predict its dynamic behaviors and stability. In this work, preceding research studies on gun-launched projectiles are investigated, and the simulation method is developed to rotate the projectile through between its rotating band and a rifled-gun tube. The proposed method is verified by comparison with experimental results, and the dynamic behaviors and stability of the projectile are evaluated under gun-launched conditions.
Kim, Ja Hyung;Kim, You Jeong;Lee, Byeong Seon;Ko, Tae Sung;Park, Young Seo
Clinical and Experimental Pediatrics
/
v.45
no.2
/
pp.232-239
/
2002
Purpose : Renal cystic diseases comprise a mixed group of heritable, developmental and acquired disorders. Recently the use of imaging modalities such as ultrasonography and radionuclide scanning has increased the detection rate of renal cystic diseases. We studied to review the clinical features and treatment of renal cystic diseases in children. Methods : This study was performed in 95 children with renal cystic diseases in the Department of Pediatrics, Asan Medical Center from October 1989 to June 2001. Results : In 95 patients, there were 55 cases(58.0%) with multicystic dysplastic kidney(MCDK), 19 cases(20.0%) with simple renal cysts, 13 cases(13.7%) with hereditary polycystic kidney diseases( 7 with autosomal recessive type, 5 with autosomal dominant type, 1 with undetermined), 6 cases(6.3%) with renal cysts in tuberous sclerosis and 1 case(1.0%) with medullary cystic disease. All MCDK patients had no renal dysfunction and hypertension during the follow-up period. Three out of 13 with polycystic kidney diseases had progressed to end-stage renal disease during the follow-up period. One case with a simple cyst underwent laparoscopic malsupialization for decompression. Conclusion : Renal cystic diseases have diverse clinicopathologic features and variable prognosis. We emphasize that routine follow-up should be performed to prevent and to detect early treatable complication in renal cystic diseases. Therefore, their natural history and treatment need further investigation and long term follow-up is required.
Transactions of the Korean Society of Mechanical Engineers A
/
v.35
no.7
/
pp.773-778
/
2011
Accelerometers are widely used to measure the lateral vibrations of pipe-like structures such as a gun tube under impulse loads. Stress waves that precede the lateral vibrations due to the explosion within a gun contribute little to the vibrations, but saturate the accelerometer input. A mechanical filter eliminates this high-frequency stress wave and only transmits the signal corresponding to the lateral vibrations. The mechanical filter consists of a mechanical structure for mounting the accelerometers and a damping material. The low-pass filter characteristics are determined from the equivalent damping and stiffness property of this damping material. In this paper, we tested nine commercially available damping materials for their vibration characteristics by using a test rig. We also observed the change in the vibration characteristics while compressing the material. We designed and manufactured a mechanical filter and verified its filtering performance.
Journal of the Korea Institute of Military Science and Technology
/
v.24
no.4
/
pp.401-407
/
2021
To confirm the change of muzzle velocity and the most suitable probability distribution model of the 155 mm K9 howitzer barrel with chrome plating and changed rifling. Using a statistical program, the muzzle velocity were plotted on a normal distribution, a 2-parameter and 3-parameter Weibull distribution on a probability paper. Also, statistical parameters were estimated and muzzle velocity fitness test and probability of K676 charge were plotted. In both the chrome-plated with standard rifling and changed rifling for K9 barrel, the 2-parameter and 3-parameter Weibull distribution were skewed to the left compared to the normal distribution. It was confirmed that the muzzle velocity of the K9 barrel with chromium-plated is suitable for the normal distribution and 3-parameter Weibull distribution model.
The Journal of Korean Institute of Electromagnetic Engineering and Science
/
v.28
no.9
/
pp.756-759
/
2017
In this paper, the radar cross section of a tank is analyzed at millimeter wave W-band. We calculate the radar cross section of the tank using the program based on PO and PTD and the computed results are compared with those of commercial simulator to check the accuracy of computations. The radar cross section is calculated in terms of the incident angle, polarization, and tank with or without cannon. The radar cross section can be reduced by changing the shape of the turret that can be applied to stealth tanks.
Journal of the Korea Institute of Military Science and Technology
/
v.9
no.3
/
pp.12-19
/
2006
A gun barrel of infantry fighting vehicle is supported like a type of cantilever. Temperature of a gun barrel is increased by heat transfer due to the combustion of propellant charge during the firing. Thus, the muzzle of a gun barrel is deflected in accordance with its temperature and the accuracy rate is decreased by deflection of the muzzle. In this study, deflection of a gun barrel is estimated by measuring its restoration rate because measuring the deflection rate is difficult due to the vibration of the gun barrel during the firing. In order to obtain the relations between deflection rate and restoration rate of the 40mm gun barrel of Next Infantry Fighting Vehicle(NIFV) under varying temperature, measurement of deflection rate and restoration rate is carried out using 5.56mm Remington rifle barrel. Effect of the estimated deflection rate of a gun barrel of NIFV on the hit probability is also analyzed.
Park, Kyung-Bae;Awh, Ok-Doo;Kim, Jae-Rok;Lim, Sang-Moo;Hong, Seong-Woon
The Korean Journal of Nuclear Medicine
/
v.23
no.1
/
pp.71-83
/
1989
For the development of $^{99m}Tc-labelled$ antimony sulfide colloid and hydroxyethyl starch, various experiments such as preparation of colloid, control of the distribution of particle size, establishment of labelling conditions, determination of labelling yield and radiochemical purity, examination of stability, and organ imagings of rabbits etc. were carried out. 1) Antimony sulfide colloid was readily prepared by the reaction of aqueous solution of antimony potassium tartrate with hydrogen sulfide generated by treating ferrous sulfide with dilute sulfuric acid. The colloid could be stabilized by adding small amount of polyvinylpyrrolidone. 2) Electron microscopy analysis exhibited the distribution of colloid size in the range of $1\sim15nm$ with a major portion of 9 m. The colloid solution was sterilized by membrane filtration $(0.2{\mu}m)$ and then stored at $4^{\circ}C$. This sterilized colloid was so stable that it was usable at least for one year. 3) The antimony sulfide colloid was labelled by adding sodium $pertechnetate-^{99m}Tc$ solution to the reaction vial, followed by adding hydrochloric acid and then boiled for 30 min. The optimal pH of the reaction mixture was found to be in the range of $1.3\sim1.4$. Instant thin layer chromatography (ITLC) analysis showed high labelling yield of above 99.5%. This labelled colloid maintained high radio-chemical purity of above 99% until 10 hours after labelling. 4) Animal studies showed high uptake of $^{99m}Tc-Sb_2S_3$ colloid at lymph vessels and nodes indicating a suitable agent for lymphoscintigraphy. Satisfactory results were also abtained in other clinical studies. 5) Hydroxyethyl starch (HES $0.6\sim1.0%$) was labelled with $Na^{99m}TcO_4$ in the presence of $SnCl_2$ with high labelling yield of above 99.5%. The optimal pH of the reaction mixture was in the range of $1.8\sim2.0$. $^{99m}Tc-HES$ maintained high radiochemical purity of above 99% until 10 hours after labelling. 6) Animal studies showed that $^{99m}Tc-HES$ migrated more rapidly from the injection sites into the lymph vessels than $^{99m}Tc-Sb_2S_3$ colloid while less amount of the former was uptaken at lymph nodes than that of the latter. Similar phenomenon was also observed in other clinical studies. As a result, $^{99m}Tc-Sb_2S_3$ colloid was found to be more effective lymphoscintigraphic agent than $^{99m}Tc-HES$.
Hong Hyun-Soook;Choi Deuk-Lin;Kim Eun-Mi;Kim Sung-Jun
Childhood Kidney Diseases
/
v.3
no.2
/
pp.187-195
/
1999
Purpose : VUR is state where urine regurge from bladder to ureter and kidney. It is shown in about 1/3 of urinary tract infection patients and it is classified as grade I to V. We compared results from RI VCUG(Radiisotope voiding cystourethrography) and X-ray VCUG which used in diagnosing VUR in children, to evaluate which is better in diagnosing VUR in children. Methods : 41 Patients(19 males, 21 females), who visited Pediatric department, Soonchunhyang university Hospital from peroid of 1991. January to 1998. July for recurrent urinary tract infection or abnormalities in ultrasonogams, were enrolled in the study. The age ranged from 9 months to 17 years and mean age was 5 1/2 years. Both RI VCUG and X-ray VCUG were done and follow-up test of urine culture, renal ultrasonogram and RI VCUG were done every month, every 3 month and every 6 month, respectively to observe the disappearance of VUR and evaluated the prognosis. Results : 24 patients had taken RI VCUG and 17(70.1%) patients showed positive result. 22 patients had taken X-ray VCUG and 9(40.1%) patients showed findings of VUR. 17 patients had taken both tests and 14 patients showed positive result in RI VCUG and 6 of these patients also showed reflux in X-ray VCUG. 3 patients who showed negative in RI VCUG, showed negative also in X-ray VCUG. For prognosis, resolution and scar formation was shown in 8 patients each. Persistent VUR was shown in 6 patients and 2 of these patients VUR was corrected by operation, 1 patient showed decreased renal function, and 1 patient was not follwed up. 8 of 9 patients who showed findings of VUR on DMSA scan formed a scar and 8 patients who showed no findings of VUR didn't form a scar. Urine culture was positive in 17 of 19 patients with VUR. Positive rate in urine culture was higher than that of patients with no VUR who showed positivity in 15 of 21 patients for urine culture. E. coli was most common organism and the period free of UTI was 14 months in VUR patients and it was shorter compared to patients without VUR which was 26 months. Conclusion : In diagnosing VUR in children, the positive rate was higher in RI VCUG than X-ray VCUG. Therefore, in early diagnosis when VUR is suspicious but not shown in X-ray VCUG, RI VCUG should be done and it will help to make accurate diagnosis.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.