• Title/Summary/Keyword: K9 포신

Search Result 9, Processing Time 0.024 seconds

An Study on the Erosion Characteristics of Tube CN98 (CN98 포신의 마모특성 연구)

  • Kim, Jae-Kab
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.42-52
    • /
    • 2006
  • Tube erosion can be defined as a phenomenon for an increment of bore diameter, a declination of accuracy and utility of tube by firing. This study introduces the characteristics of tube life for the 155 mm K9 SHP Using a tube history book with bore measurement data and firing data of standard charge, this study analyzed the EFC vs Tube life and EFC with heat transfer effect formula as a consideration of continuous firing vs tube life. The results were compared with Firing Table(FT 155-K9-1) after the analysis. Also, this study suggests that CN98 tube can be rifled as 1000 EFC through the severe condition with continuous firing.

Numerical Simulation of a Gun-launched Projectile Considering Rifled-gun Tube (포신의 강선을 고려한 포 발사 해석)

  • Joo, Geunsu;Huh, Hoon;Jung, Yeong Hyuk;Kim, Ju Yeong;Seo, Songwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.9
    • /
    • pp.877-885
    • /
    • 2017
  • This paper is concerned with numerical simulation of a gun-launched projectile considering a rifled gun-tube. Gun-launched conditions induce dynamic behaviors, such as high pressure and high speed rotation. A projectile and its internal electronic components may be damaged in such harsh environments. Hence, it is necessary to perform numerical simulation of a gun-launched projectile to predict its dynamic behaviors and stability. In this work, preceding research studies on gun-launched projectiles are investigated, and the simulation method is developed to rotate the projectile through between its rotating band and a rifled-gun tube. The proposed method is verified by comparison with experimental results, and the dynamic behaviors and stability of the projectile are evaluated under gun-launched conditions.

Clinical Study of Renal Cystic Diseases in Children (소아의 낭포성 신질환에 대한 임상적 고찰)

  • Kim, Ja Hyung;Kim, You Jeong;Lee, Byeong Seon;Ko, Tae Sung;Park, Young Seo
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.2
    • /
    • pp.232-239
    • /
    • 2002
  • Purpose : Renal cystic diseases comprise a mixed group of heritable, developmental and acquired disorders. Recently the use of imaging modalities such as ultrasonography and radionuclide scanning has increased the detection rate of renal cystic diseases. We studied to review the clinical features and treatment of renal cystic diseases in children. Methods : This study was performed in 95 children with renal cystic diseases in the Department of Pediatrics, Asan Medical Center from October 1989 to June 2001. Results : In 95 patients, there were 55 cases(58.0%) with multicystic dysplastic kidney(MCDK), 19 cases(20.0%) with simple renal cysts, 13 cases(13.7%) with hereditary polycystic kidney diseases( 7 with autosomal recessive type, 5 with autosomal dominant type, 1 with undetermined), 6 cases(6.3%) with renal cysts in tuberous sclerosis and 1 case(1.0%) with medullary cystic disease. All MCDK patients had no renal dysfunction and hypertension during the follow-up period. Three out of 13 with polycystic kidney diseases had progressed to end-stage renal disease during the follow-up period. One case with a simple cyst underwent laparoscopic malsupialization for decompression. Conclusion : Renal cystic diseases have diverse clinicopathologic features and variable prognosis. We emphasize that routine follow-up should be performed to prevent and to detect early treatable complication in renal cystic diseases. Therefore, their natural history and treatment need further investigation and long term follow-up is required.

An Experimental Study on the Material Characteristics of Mechanical Filters for Eliminating High-Frequency Noise in Accelerometer Measurements (가속도 측정에 있어 고주파 잡음 제거를 위한 기계적 필터의 재료 특성에 관한 실험적 연구)

  • Choi, Won-Yeong;Yoo, Seong-Yeol;Cha, Ki-Up;Kim, Sung-Soo;Noh, Myoung-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.7
    • /
    • pp.773-778
    • /
    • 2011
  • Accelerometers are widely used to measure the lateral vibrations of pipe-like structures such as a gun tube under impulse loads. Stress waves that precede the lateral vibrations due to the explosion within a gun contribute little to the vibrations, but saturate the accelerometer input. A mechanical filter eliminates this high-frequency stress wave and only transmits the signal corresponding to the lateral vibrations. The mechanical filter consists of a mechanical structure for mounting the accelerometers and a damping material. The low-pass filter characteristics are determined from the equivalent damping and stiffness property of this damping material. In this paper, we tested nine commercially available damping materials for their vibration characteristics by using a test rig. We also observed the change in the vibration characteristics while compressing the material. We designed and manufactured a mechanical filter and verified its filtering performance.

Analysis of Probability Distribution of Muzzle Velocity for Chrome Plated Barrel (크롬도금 포열의 포구속도 확률분포 특성 분석)

  • Kim, Jaekab;Kim, Jaehoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.401-407
    • /
    • 2021
  • To confirm the change of muzzle velocity and the most suitable probability distribution model of the 155 mm K9 howitzer barrel with chrome plating and changed rifling. Using a statistical program, the muzzle velocity were plotted on a normal distribution, a 2-parameter and 3-parameter Weibull distribution on a probability paper. Also, statistical parameters were estimated and muzzle velocity fitness test and probability of K676 charge were plotted. In both the chrome-plated with standard rifling and changed rifling for K9 barrel, the 2-parameter and 3-parameter Weibull distribution were skewed to the left compared to the normal distribution. It was confirmed that the muzzle velocity of the K9 barrel with chromium-plated is suitable for the normal distribution and 3-parameter Weibull distribution model.

Analysis of Radar Cross Section of the Tank and Its Application at Millimeter Wave W-Band (밀리미터파 W-대역에서 전차의 레이다 단면적 해석 및 응용)

  • Shin, Hokeun;Song, Sung Chan;Kim, Jihyung;Park, Yong Bae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.9
    • /
    • pp.756-759
    • /
    • 2017
  • In this paper, the radar cross section of a tank is analyzed at millimeter wave W-band. We calculate the radar cross section of the tank using the program based on PO and PTD and the computed results are compared with those of commercial simulator to check the accuracy of computations. The radar cross section is calculated in terms of the incident angle, polarization, and tank with or without cannon. The radar cross section can be reduced by changing the shape of the turret that can be applied to stealth tanks.

Analysis of the Estimation of the Deflection and Hit Probability of a Gun Barrel of Next Infantry Fighting Vehicle (차기 보병전투장갑차 포신 처짐량 예측 및 명중률 분석)

  • Yoo, Sam-Hyeon;Chung, Dong-Yoon;Oh, Myoung-Ho;Shin, Nae-Ho;Nam, Suk-Hyun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.12-19
    • /
    • 2006
  • A gun barrel of infantry fighting vehicle is supported like a type of cantilever. Temperature of a gun barrel is increased by heat transfer due to the combustion of propellant charge during the firing. Thus, the muzzle of a gun barrel is deflected in accordance with its temperature and the accuracy rate is decreased by deflection of the muzzle. In this study, deflection of a gun barrel is estimated by measuring its restoration rate because measuring the deflection rate is difficult due to the vibration of the gun barrel during the firing. In order to obtain the relations between deflection rate and restoration rate of the 40mm gun barrel of Next Infantry Fighting Vehicle(NIFV) under varying temperature, measurement of deflection rate and restoration rate is carried out using 5.56mm Remington rifle barrel. Effect of the estimated deflection rate of a gun barrel of NIFV on the hit probability is also analyzed.

Studies on the Preparation of $^{99m}TC$ Labelled Antimony Sulfide Colloid and Hydroxyethyl Starch for Lymphoscintigraphy (림포신티그래피용 $^{99m}TC$를 표지황화안티몬 콜로이드 및 전분의 제조에 관한 연구)

  • Park, Kyung-Bae;Awh, Ok-Doo;Kim, Jae-Rok;Lim, Sang-Moo;Hong, Seong-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.1
    • /
    • pp.71-83
    • /
    • 1989
  • For the development of $^{99m}Tc-labelled$ antimony sulfide colloid and hydroxyethyl starch, various experiments such as preparation of colloid, control of the distribution of particle size, establishment of labelling conditions, determination of labelling yield and radiochemical purity, examination of stability, and organ imagings of rabbits etc. were carried out. 1) Antimony sulfide colloid was readily prepared by the reaction of aqueous solution of antimony potassium tartrate with hydrogen sulfide generated by treating ferrous sulfide with dilute sulfuric acid. The colloid could be stabilized by adding small amount of polyvinylpyrrolidone. 2) Electron microscopy analysis exhibited the distribution of colloid size in the range of $1\sim15nm$ with a major portion of 9 m. The colloid solution was sterilized by membrane filtration $(0.2{\mu}m)$ and then stored at $4^{\circ}C$. This sterilized colloid was so stable that it was usable at least for one year. 3) The antimony sulfide colloid was labelled by adding sodium $pertechnetate-^{99m}Tc$ solution to the reaction vial, followed by adding hydrochloric acid and then boiled for 30 min. The optimal pH of the reaction mixture was found to be in the range of $1.3\sim1.4$. Instant thin layer chromatography (ITLC) analysis showed high labelling yield of above 99.5%. This labelled colloid maintained high radio-chemical purity of above 99% until 10 hours after labelling. 4) Animal studies showed high uptake of $^{99m}Tc-Sb_2S_3$ colloid at lymph vessels and nodes indicating a suitable agent for lymphoscintigraphy. Satisfactory results were also abtained in other clinical studies. 5) Hydroxyethyl starch (HES $0.6\sim1.0%$) was labelled with $Na^{99m}TcO_4$ in the presence of $SnCl_2$ with high labelling yield of above 99.5%. The optimal pH of the reaction mixture was in the range of $1.8\sim2.0$. $^{99m}Tc-HES$ maintained high radiochemical purity of above 99% until 10 hours after labelling. 6) Animal studies showed that $^{99m}Tc-HES$ migrated more rapidly from the injection sites into the lymph vessels than $^{99m}Tc-Sb_2S_3$ colloid while less amount of the former was uptaken at lymph nodes than that of the latter. Similar phenomenon was also observed in other clinical studies. As a result, $^{99m}Tc-Sb_2S_3$ colloid was found to be more effective lymphoscintigraphic agent than $^{99m}Tc-HES$.

  • PDF

Comparison of X-ray VCUG with RI VCUG for Diagnosing VUR in Children (소아의 방광 요관 역류 진단시 X-ray 배뇨성 방광 요도 조영술(X-ray VCUG)과 방사성 동위원소 배뇨성 방광 요도 조영술(RI VCUG)의 비교)

  • Hong Hyun-Soook;Choi Deuk-Lin;Kim Eun-Mi;Kim Sung-Jun
    • Childhood Kidney Diseases
    • /
    • v.3 no.2
    • /
    • pp.187-195
    • /
    • 1999
  • Purpose : VUR is state where urine regurge from bladder to ureter and kidney. It is shown in about 1/3 of urinary tract infection patients and it is classified as grade I to V. We compared results from RI VCUG(Radiisotope voiding cystourethrography) and X-ray VCUG which used in diagnosing VUR in children, to evaluate which is better in diagnosing VUR in children. Methods : 41 Patients(19 males, 21 females), who visited Pediatric department, Soonchunhyang university Hospital from peroid of 1991. January to 1998. July for recurrent urinary tract infection or abnormalities in ultrasonogams, were enrolled in the study. The age ranged from 9 months to 17 years and mean age was 5 1/2 years. Both RI VCUG and X-ray VCUG were done and follow-up test of urine culture, renal ultrasonogram and RI VCUG were done every month, every 3 month and every 6 month, respectively to observe the disappearance of VUR and evaluated the prognosis. Results : 24 patients had taken RI VCUG and 17(70.1%) patients showed positive result. 22 patients had taken X-ray VCUG and 9(40.1%) patients showed findings of VUR. 17 patients had taken both tests and 14 patients showed positive result in RI VCUG and 6 of these patients also showed reflux in X-ray VCUG. 3 patients who showed negative in RI VCUG, showed negative also in X-ray VCUG. For prognosis, resolution and scar formation was shown in 8 patients each. Persistent VUR was shown in 6 patients and 2 of these patients VUR was corrected by operation, 1 patient showed decreased renal function, and 1 patient was not follwed up. 8 of 9 patients who showed findings of VUR on DMSA scan formed a scar and 8 patients who showed no findings of VUR didn't form a scar. Urine culture was positive in 17 of 19 patients with VUR. Positive rate in urine culture was higher than that of patients with no VUR who showed positivity in 15 of 21 patients for urine culture. E. coli was most common organism and the period free of UTI was 14 months in VUR patients and it was shorter compared to patients without VUR which was 26 months. Conclusion : In diagnosing VUR in children, the positive rate was higher in RI VCUG than X-ray VCUG. Therefore, in early diagnosis when VUR is suspicious but not shown in X-ray VCUG, RI VCUG should be done and it will help to make accurate diagnosis.

  • PDF