• Title/Summary/Keyword: K5 system

Search Result 31,957, Processing Time 0.059 seconds

Reflecting and Dielectric Characteristics of $P_2O_5-ZnO\;and\;SiO_2-ZnO-B_2O_3$ Dielectric Systems due to the Contents of $TiO_2$ ($TiO_2$ 함량에 따른 $P_2O_5-ZnO$계와 $SiO_2-ZnO-B_2O_3$계 유전체의 반사 및 유전특성)

  • Ryu, Boo-Hyung;Kwon, Soon-Suk
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.4 s.72
    • /
    • pp.29-33
    • /
    • 2005
  • In this paper, reflectance and the dielectric characteristics for $P_2O_5-ZnO-BaO$ system and $SiO_2-ZnO-B_2O_3$ system have been investigated as a function of contents of $TiO_2$. The reflectance was decreased with increasing the contents of $TiO_2$ and the reflectance of $P_2O_5-ZnO-BaO$ system was lowered than that of $SiO_2-ZnO-B_2O_3$ system. The dielectric constant of $P_2O_5-ZnO-BaO$ system was higher than $SiO_2-ZnO-B_2O_3$ system, and the dielectric constant in the both system was increased with increasing of $TiO_2$ contents. This can be explained as the space charge effects. These results are could be applied to the under plate dielectrics of PDP required high reflective ratio and breakdown strength.

Synthesis and Photovoltaic Properties of Novel Ruthenium(II) Sensitizers for Dye-sensitized Solar Cell Applications

  • Ryu, Tae-In;Song, Myung-Kwan;Lee, Myung-Jin;Jin, Sung-Ho;Kang, Sun-Woo;Lee, Jin-Yong;Lee, Jae-Wook;Lee, Chan-Woo;Gal, Yeong-Soon
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.10
    • /
    • pp.2329-2337
    • /
    • 2009
  • Three heteroleptic ruthenium sensitizers, Ru(L)($L^1)(NCS)_2$ [L = 4,4'-dicarboxylic acid-2,2'-bipyridine, Ru-T1: $L^1$ = (E)-2-(4'-methyl-2,2'-bipyridin-4-yl)-3-(thiophen-2-yl)acrylonitrile, Ru-T2: $L^2$ = (E)-3-(5'-hexyl-2,2'-bithiophen-5- yl)-2-(4'-methyl-2,2'-bipyridin-4-yl)acrylonitrile, and Ru-T3: $L^3$ = (E)-3-(5"-hexyl-2,2':5',2"-terthiophen-5-yl)-2- (4'-methyl-2,2'-bipyridin-4-yl)acrylonitrile)], were synthesized and used as photosensitizers in nanocrystalline dyesensitized solar cells (DSSCs). The introduction of the 3-(5-hexyloligothiophen-5-yl)acrylonitrile group increased the conjugation length of the bipyridine donor ligand and thus improved their molar absorption coefficient and light harvesting efficiency. DSSCs with the configuration of Sn$O_2$: F/Ti$O_2$/ruthenium dye/liquid electrolyte/Pt devices were fabricated using these Ru-$T1{\sim}T3$ as a photosensitizers. Among the devices, the DSSCs composed of Ru-T2 exhibited highest power conversion efficiency (PCE) of 2.84% under AM 1.5 G illumination (100 mW/$cm^2$).

A Study of the HTML5-based Mobile Order Communication System

  • Ahn, Yoon-Ae;Cho, Han-Jin
    • International Journal of Contents
    • /
    • v.9 no.1
    • /
    • pp.11-17
    • /
    • 2013
  • Recently, online real-time web accessible mobile devices such as smartphones, tablet PCs and application services have been developing rapidly. Hospitals also need to adopt an efficient information system that can provide decent medical services under mobile computing environments to complete future medical services. This study proposes a system in which a doctor can examine a patient and make out a prescription in a ward on a real-time based on the current Order Communication Systems (OCSs) through mobile interfaces. The proposed system implements mobile web pages using HTML5, instead of a mobile app. Web processing speed can be enhanced using the web socket and web storage functions of HTML5.

Volume Optimization of a Combined System of LNT and SCR Catalysts Considering Economic Feasibility and De-NOx Performance

  • Seo, Choong-Kil;Choi, Byung-Chul;Kim, Young-Kwon
    • Journal of Power System Engineering
    • /
    • v.17 no.1
    • /
    • pp.19-26
    • /
    • 2013
  • The purpose of the study is carried out volume optimization of a combined system consisting of an LNT and SCR catalysts from the standpoint of its economic feasibility and de-NOx performance. Under the rich air-fuel ratio conditions for 5s (${\Phi}$=1.1), CO, $H_2$ and THC were generated at levels of 4%, 1.2% and $110ppmC_1$, respectively. The NOx conversion of the 1+1 combination was 5% lower than that of the 1.5+0.5 combination, however the reduced volume of the LNT catalyst decreased the total cost by about 6%. Therefore, the optimal volume ratio of the LNT and SCR catalysts was found to be the 1+1 catalyst combination, which has the highest total score in the terms of an economic feasibility and the NOx performance.

5-Axis Cross-Coupling Control System Based on a Novel Real-Time Tool Orientation Error Model (새로운 실시간 공구방향오차 모델에 기초한 5 축 연동제어 시스템)

  • Byun, Je-Hyung;Jee, Sung-Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.8
    • /
    • pp.48-53
    • /
    • 2010
  • 5-axis CNC machining now is getting popular because it can deal with complex shapes such as impeller, turbine blade and propeller without additional equipment or process, proving a set of various tool orientations. CAM software related to 5-axis machining is being developed quickly so that users can take advantage of potential capacities of 5-axis machine tools. However, only a few researches can be found in the area of control strategy development for 5-axis machining. This paper proposes a 5-axis cross-coupling control system based on a novel tool orientation error model. The proposed tool orientation error model provides accurate information on the tool orientation error in real time, which in turn enables directly controlling the tool orientation accuracy. The proposed control system also employs a contour error model to calculate the contour error and reflect it in the control as well. The accuracy of the proposed tool orientation error model is verified and the performance of the 5-axis cross-coupling control system in terms of both contouring and tool orientation accuracy is evaluated through computer simulations compared with existing 5-axis control systems.

The Conversion of Lithocholic Acid into 5$\beta$-Androstan-3, 17-dione in the Cell-free System of Mycobacterium sp. NRRL B-3805

  • Lee, Kang-Man;Park, Hye-Kyung
    • Archives of Pharmacal Research
    • /
    • v.14 no.3
    • /
    • pp.261-265
    • /
    • 1991
  • In a microbial cell-free extract system, side chain cleavage on various sterols and steroids was tested. The cell-free extracts of Mycobacterium sp. NRRL B-3805 showed the side chain cleavage activity on lithocholic acid to form 5$\beta$-androstan-3.17-dione. The properties of the activity were examined.

  • PDF

RADIO ASTRONOMICAL DATA PROCESSING USING MARK5B (MARK5B 시스템을 이용한 전파천문 데이터 처리)

  • Oh, Se-Jin;Yeom, Jae-Hwan;Roh, Duk-Gyoo;Chung, Hyun-Soo;Je, Do-Heung;Kim, Kwang-Dong;Kim, Bum-Koog;Hwang, Cheol-Jun;Jung, Gu-Young
    • Publications of The Korean Astronomical Society
    • /
    • v.21 no.2
    • /
    • pp.95-100
    • /
    • 2006
  • In this paper, we describe the radio astronomical data processing system implementation using Mark5B and its development. KASI(Korea Astronomy and Space Science Institute) is constructing the KVN (Korean VLBI Network) until the end of 2007, which is the first VLBI(Very Long Baseline Interferometery) facility in Korea and dedicated for the mm-wave VLBI observation. KVN will adopt the DAS (Data Acquisition System) consisting of digital filter with various function and 1Gsps high-speed sampler to digitize the radio astronomical data for analyzing on the digital filter system. And the analyzed data will be recorded to recorder up to 1Gbps data rates. To test this, we have implemented the system which is able to process 1Gbps data rates and carried out the data recording experiment.

Performance Analysis and Automatic Configuration of Threshold on Anti-Pinch System Based on Current Information for Power Windows (전류정보 기반의 파워 윈도우용 안티핀치 시스템의 전류 임계값 자동 설정 및 성능 분석)

  • Park, Seung-Seob;Jeong, Seok-Kwon
    • Journal of Power System Engineering
    • /
    • v.21 no.5
    • /
    • pp.63-70
    • /
    • 2017
  • This paper deals with anti-pinch system based on current information which prevents some risks for trapping, squeezing or injury to people in smart window on vehicles. Automatic configuration of current threshold is suggested to recognize pinch states in the current based anti-pinch system. Also, some factors affecting to the squeezing force were analyzed by some experimental results and simulations. The validity of the suggested system was verified to satisfy the strengthened American safety regulation, FMVSS 118-S5, through some experimental results.

Study on Suggestion of Smoke-proof System Using a Restroom for a Refuge Space (화장실 이용 피난공간의 방연시스템 제안 및 실규모 실험)

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.61-66
    • /
    • 2012
  • In restroom on high-rise building, exhaust system comprising the blower and duct is installed to discharge the odor and the water is suppled. Thus the restroom with fire and flame protection system may be used as refuge area in a fire situation. The study presents the smoke-proof system which operates such that the exhaust system to discharge the odor is converted to air supply system and appropriate pressure difference between the restroom and the accommodation is maintained. Also real-scale test facilities of smoke-proof system for refuge space using a restroom are installed on 5-story smoke control test building and experiments for evaluating the operational performance of smoke-proof system are carried out.

Analysis of Human Safety and System Effect according to Grounding Scheme in LVDC Distribution System (LVDC 배전계통의 접지방식에 따른 인체안전 및 계통영향 분석)

  • Oh, Yun-Sik;Han, Joon;Gwon, Gi-Hyeon;Kim, Doo-Ung;Noh, Chul-Ho;Jung, Tack-Hyun;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.5
    • /
    • pp.608-614
    • /
    • 2014
  • Recent developments and trends in the electric power consumption clearly indicate an increasing use of DC in end-user equipment. According to the trends, new DC power distribution systems have been researched and developed although we presently enjoy a predominantly AC power distribution system. We can use various grounding schemes in DC distribution system as well as in AC distribution system to protect human body and equipments. However, we need to evaluate carefully which grounding scheme is appropriate for a specific system before applying those schemes. In this paper, we analyze the human safety and system effect according to various grounding schemes in Low Voltage DC (LVDC) distribution system. Some components in LVDC distribution system are modeled and computer simulations are conducted by using ElectroMagnetic Transient Program (EMTP).