• Title/Summary/Keyword: K5 system

Search Result 31,957, Processing Time 0.063 seconds

Study on Induction Capability of Chilled Beam HVAC System (Chilled Beam 공조시스템의 유인성능 해석)

  • Kim, Jung-Yup;Shin, Hyun-Jun;Kim, Ji-Seok;Joo, Sang-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.5
    • /
    • pp.255-260
    • /
    • 2013
  • Since a chilled beam system can reduce the conveyance energy for air conditioning and has many advantages in terms of constructability and indoor environment, its supply has been rapidly expanding mainly in Europe. For this chilled beam system to be effectively available in Korea, a product suitable for the domestic climatic environment and HVAC system operating conditions needs to be developed. Also, domestic products need to have an edge in cost competitiveness compared to overseas products. In this study, the induction structure of a chilled beam is deduced and an analysis on the induction performance is carried out while the chilled beam system that meets domestic situations is in the process of development.

Analysis of Power Supply System for 8.5 MVA Magnetic Power Supply Using EI (EMTDC를 이용한 8.5 MVA급 Magnetic Power Supply의 전력공급 시스템 분석)

  • Jeong, Yong-Hoo;Nho, Eui-Cheol;Kim, In-Dong;Choi, Jung-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1114-1116
    • /
    • 2002
  • The characteristics of voltage drop and THD for parallel operating 11 PCRs (Phase Controlled Rectifiers) are analysed. The PCRs are used to drive high current (1.6 kA ${\sim}$ 3.7 kADC) electromagnetic coils for electromagnets. All the PCRs operate simultaneously in pulsed mode, and the pulse shot occurs every 150 seconds. During the pulse operation the PCR output current ramps up for 4 seconds, and then keeps flat top state for 2 seconds, and finally ramps down for 4 seconds. For the flat top mode a severe voltage drop and distortion appear in the power system because transformers for the PCRs are designed considering pulsed mode operation. It is expected that the analysis method can be applied to improve the system performance including power factor and design of high power pulsed mode operating power supply systems.

  • PDF

Large-area Synthesis of Well-aligned, Thin Multi-walled Carbon Nanotubes at Low Temperature (수직 정렬된 저직경 다중벽 탄소나노튜브의 저온 대면적 합성)

  • Kim, Young-Rae;Jang, In-Goo;Cho, Jung-Keun;Hwang, Ho-Soo;Kong, Byung-Yun;Lee, Nae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.418-419
    • /
    • 2007
  • 플라즈마 열화학기상 증착법으로 Fe-Ni-Co 3원계 측매합금을 이용하여 $442^{\circ}C$의 저온에서 다중벽 탄소나노튜브를 합성하였다. 수소의 유량이 일정할 때 아세틸렌의 유량이 감소함에 따라 성장속도가 증가하였다. 합성된 탄소나노튜브는 약 8.4 nm의 직경과 $5.5\;{\mu}m$의 길이를 보였으며, 기판에 대해 수직으로 성장되었다. 4인치 웨이퍼 위에서도 전면적에서 균일한 성장을 보였다.

  • PDF

The Energy Performance Evaluation of Multi-purpose Solar Window System (다기능 복합 솔라윈도우 시스템의 에너지성능평가)

  • Cho, Yil-Sik;Kim, Byoung-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.10-15
    • /
    • 2010
  • The aim of this study was to analysis the Heating/cooling performance of Solar Window System built in apartments. The solar window is the idea to integrate daylight as a third form of solar energy into a PV/Solar Collector system and allows more control due to the possibility to close the reflectors. However, there can be a conflict between the desire for on one hand daylight and view and on the other hand optimal energy conversion for the PV/Solar Collector system. The process of this study is as follows: 1) The Solar Window system is designed through the investigation of previous paper and work. 2)The simulation program(ESP-r, Therm5.0, Window6.0) was used in energy performance analysis. The reference model of simulation was made up to analysis energy performance on Solar Window system. 3)Selected reference model(Floors:15, Area of Unit:$148.5m^2$) for heating/cooling energy analysis, Energy performance simulation with various variants, such as U-value of Solar Window system according to its position and angle. Consequently, When Solar Window system is equipped with balcony window of Apartment, Annual heating and cooling energy of reference model was cut down about 5%~11%.

IN VITRO MICRO-SHEAR BOND STRENGTH OF FIVE COMPOSITE RESINS TO DENTIN WITH FIVE DIFFERENT DENTIN ADHESIVES (미세-전단 결합 강도 시험을 이용한 상아질 접착제와 수복용 복합 레진의 호환성에 관한 연구)

  • Chung, Jin-Ho;Roh, Byoung-Duck
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.4
    • /
    • pp.353-364
    • /
    • 2004
  • The purpose of this study was to compare and to evaluate the combination use of 5 kinds of dentin adhesive systems and 5 kinds of composite resins using micro-shear bond test. Five adhesive systems (Prime & Bond NT (PBN). Onecoat bond (OC), Excite (EX), Syntac (SY), Clearfil SE bond (CS)) and five composite resins (Spectrum (SP), Synergy Compact (SC), Tetric Ceram (TC), Clearfil AP-X (CA), Z100 (Z1)) were used for this study ($5{\;}{\times}{\;}5{\;}={\;}25group$, n =14/group). The slices of horizontally sectioned human tooth were bonded with each bonding system and each composite resin, and tested by a micro-shear bond strength test. These results were analyzed statistically. The mean micro-shear bond strength of dentin adhesive systems were in order of CS (22.642 MPa), SY (18.368 MPa), EX (14.599 MPa). OC (13.702 MPa). PBN (12.762 MPa). The mean bond strength of self-etching primer system group (CS, SY) in dentin was higher than that of self-priming adhesive system groups (PBN, EX, OC) significantly (P<0.05). The mean bond strength of composite resins was in order of SP (19.008 MPa), CA (17.532 MPa). SC (15.787 MPa), TC (15.068 MPa). Z1 (14.678 MPa). Micro-shear bond strength of SP was stronger than those of other composite resins significantly (P < 0.05). And those of TC and Z1 were weaker than other composite resins significantly (P < 0.05). No difference was found in micro-shear bond strength of composite resin in self-etching primer adhesive system groups (CS, SY) statistically. However, there was significant difference of micro-shear bond strength of composite resin groups in self-priming adhesive systems group (PBN, EX, OC). The combination of composite resin and dentin adhesive system recommended by manufacturer did not represent positive correlation. It didn't seem to be a significant factor.

A Study on the Actual Conditions of School Food Service in Japan (일본 학교급식 실태에 관한 연구)

  • Yoo, Young-Sang;Masamitchu, Miyoshi
    • Journal of the Korean Society of Food Culture
    • /
    • v.9 no.5
    • /
    • pp.467-478
    • /
    • 1995
  • The school food service system has been an important national policy in Korea. To find out the reference data of the school food service system, we surveyed four primary schools, one middle school, and one food service center in Nara, Japan. The results are as follows; 1. The school food service was carried out in 99.4% of primary school children and in 82.5% of middle school students. 2. The central commissary school food service system was utilized at 49.0% of primary schools and 68.5% of middle schools. 3. The expense of the system is supported partially by the student's parents and partially by the government, of which the support rate was noticed by the law of school food service. 4. The dietary content of school food service was laid down by 'The rule of the operation basis of school food service'. The menu was chosen by the 7 kinds of stepwise meetings. 5. The teachers emphasized on the food etiquette, the appreciation to the food and the personal relationship during meal, as well as on the nutritional balance. 6. We found other problems in Japanese food service system, such as the sanitary problems, the problems of the new tableware, and whether the central kitchen had less advantage than the individual school kitchen. We can conclude that the school food service system is becoming the essential part in school education, and hope to design not only economical but also educational system in Korea, with the consideration of Japanese system.

  • PDF

Development of Transportational Guide System for Joining Small Wire with Gabion (개비온 끝단 소둔선 결합용 이송 가이드 장치 개발 연구)

  • Lee, Jong kil;Kin, Jong-Tae
    • 대한공업교육학회지
    • /
    • v.31 no.1
    • /
    • pp.211-225
    • /
    • 2006
  • Gabion can be used for the purpose of preventing overflow of river and side loss of road. However the manufacturing process of the gabion is manually controlled especially to the joining process at the terminal part of gabion with small diameter wire. In this paper automatic feeding guide system was designed and fabricated to make automation. The fabricated system was tested in the factory level. Pneumatic system was considered as the main idea of the feeding system. 3/2-way and 5/2-way manual control valve, eight double-acting cylinders were used. The system took 46.48 seconds during a cycle. Additional environmental noise and vibration were not detected when the machine operated at the working area. Based on the theoretical simulation and actual test the fabricated system was well controlled. The system was applied to the patent in 2006.

Development of the Parental Educational Multimedia System for Health Promotion of Children in Chungnam Province (충남지역 아동의 건강증진을 위한 멀티미디어 재택 부모교육 시스템 개발)

  • Yoo, Kyung-Hee;Lee, Hye-Kyung;Woo, Hee-Kyoung
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.7 no.1
    • /
    • pp.81-93
    • /
    • 2001
  • The purpose of this study was to develop Parental Educational Multimedia System for Health Promotion of Children in Chungnam province. This system includes education programs for information of diseases, prevention of disease, and health promotion of children. Computer language used in this study were html, OS used was Microsoftware NT Server 4.0, the graphic tool was Adobe Photoshop 5.5, and Webpage tool was Notepade. The results of this study were show at internet 'www. ggomalove.co.kr'. Finally, the author suggests that this system could be adequately applied to promoting children's health. Further this study contributes to designing an appropriate health promotion strategy for children.

  • PDF

Numerical Studies on the Deceleration Characteristics of Supersonic Projectile According to the Test Condition Parameters in a Soft Recovery System (저감속 회수장비 시험조건에 따른 초음속 시험탄 감속특성에 대한 수치해석적 연구)

  • Song, Minsup;Kim, Jaehoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.485-493
    • /
    • 2020
  • Numerical analyses were performed using a one-dimensional Euler equation and Godunov Harten-Lax-Van Leer(HLL) Riemann solver in order to study the deceleration characteristics of a 155 mm projectile in a soft recovery system. The soft recovery system consisting of a series of pressure tubes is a system that decelerates the test projectile fired at supersonic speed using a high-pressure gas and filled water inside. Therefore, depending on the gas pressure and the amount of water filling, the deceleration and the exit velocity of the test projectile inside the pressure tube are determined. In this paper, the deceleration characteristics of the test projectile were analyzed according to the gas pressure and water mass filled.

Stand-Alone Wind Energy Conversion System with an Asynchronous Generator

  • Singh, Bhim;Sharma, Shailendra
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.538-547
    • /
    • 2010
  • This paper deals with a stand-alone wind energy conversion system (WECS) with an isolated asynchronous generator (IAG) and voltage and frequency (VF) control feeding three-phase four-wire loads. The reference generator currents are estimated using the instantaneous symmetrical component theory to control the voltage and frequency of an IAG system. A three-leg voltage source converter (VSC) with an isolated star/delta transformer is used as an integrated VSC. An integrated VSC with a battery energy storage system (BESS) is used to control the active and reactive powers of the WECS. The WECS is modeled and simulated in MATLAB using the Simulink and the Sim Power System (SPS) toolboxes. The proposed VF controller functions as a voltage and frequency regulator, a load leveler, a load balancer and a harmonic eliminator in the WECS. A comparison is made on the rating of the VSC with and without ac capacitors connected at the terminals of an IAG. Simulation and test results are presented to verify the control algorithm.