• Title/Summary/Keyword: K2P distance

Search Result 1,048, Processing Time 0.036 seconds

Analysis on Differences in Muscle Activities Depending on Distance Changes and Success or Failure in Connection with Golf Approach Swings (골프 어프로치 스윙 시 거리변화와 성공·실패에 따른 EMG 차이 분석)

  • Lee, Kyung-Ill;You, Moon-Seok;Hong, Wan-Ki
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.1
    • /
    • pp.21-28
    • /
    • 2015
  • Objectives : The purpose of this study was to compare differences in muscle activities according to distance changes, and success or failure in relation to approaches during a round of golf in order to obtain basic data on golf swings. Methods : To achieve our research goal, we asked eight professional golfers playing for the Korea Professional Golfers' Association (height: $1.76{\pm}0.05m$, weight: $73.87{\pm}9.21kg$, career duration: $12.87{\pm}4.48yr$) to perform approach swings at distances of 30, 50, and 70 m. Results : No differences were observed in the muscle activity of the extensor carpi radialis that were caused by the distance changes. In addition, we found that the wrist extensors seemed unaffected by the increase in approach distance. Also, we found that the powers of the approach shots were driven by efficient movements rather than by the strength of the arms. We confirmed that when the distance of the approach increased, the golfers should perform their back-swing tops and follow-through right from the right to the left pelvic limb. To achieve successful approach swings despite distance changes, golfers should first work on the activity of the erector spinae to prepare for rotatory power in the P1 section. Moreover, golfers should increase the activity of the erector spinae on the left when they need to deal with the distance improvements in the P2 and P3 sections. Conclusion : In the light of the discussion above, we may infer that despite approach distance changes during a round of golf, ideal swings can be realized by consistent activities of the wrist extensor muscles and improved performances of the pelvic limb muscles. Furthermore, this study suggests that golfers should improve the consistency of muscle activities in all the other body parts to achieve the ideal swing.

A Study of Comparison Between Refractive Errors by Fixation Distance Variation with N-vision(open-view type) Auto-refractor and Refractive Error with Canon(Internal Fixation Target Type) Auto-refractor (개방형 자동굴절검사기의 주시거리에 따른 굴절이상도와 가상주시형 자동굴절 검사기의 굴절이상도와의 비교 연구)

  • Kim, Jae-Do;Kim, Tae-Hyun;Jeon, In-Chul
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.433-438
    • /
    • 2011
  • Purpose: To investigate the proper distance from patient to target when measuring refractive error using open view target type auto-refractor(OVTAR), it was compared refractive errors between by OVTAR using N-vision-K5001 auto-refractor and internal fixation target type auto-refractor(IFTAR) using Canon auto-refractor. Methods: 21 subjects(42 eyes) aged 22.2(${\pm}$3.4) years old who had over 1.0 of corrected visual acuity and no ocular disease were participated for this study. Noncycloplegic measurements of refractive error were performed using a IFTAR(RK-F1, Canon, Japan) and an OVTAR(N-vision-K5001, Shin-nippon, Japan). The distances from subjects to targets in using the open the view target type auto-refractor were 1 m, 3 m, 4 m and 6 m. The refractive errors were compared between by IFTAR and by 1 m, 3 m, 4 m and 6 m target distances respectively using OVTAR. Results: At 1 m fixation distance the mean of refractive errors for total subjects was not significantly different between by OVTAR(-2.75${\pm}$1.84 D) and by IFTAR(-2.95${\pm}$2.04 D)(p=0.06). However at 3, 4 and 6 m fixation distance refractive errors by OVTAR were significantly lower myopic refractive errors than by IFTAR(p<0.05). Conclusions: The distance from subject to fixation target is needed over 3 m for the measurement of refractive error using OVTAR even not to 5~6 m distance.

Influence of Multiple Rib Fracture upon Traumatic Hemo-pneumothorax (다발성 늑골골절의 외상성 혈기흉 발생에 대한 영향)

  • Yang, Seung-Joon;Lee, Je-won;Jin, Sang-Chan;Joo, Myeong-Don;Choi, Woo-Ik
    • Journal of Trauma and Injury
    • /
    • v.21 no.2
    • /
    • pp.91-99
    • /
    • 2008
  • Purpose: Multiple rib fracture (MRF) and a hemopneumothorax accompany with most blunt chest traumas. We aimed to analyze the factors increasing the probability of a hemopneumothorax. In addition, other injuries accompanying MRF were analyzed. Methods: We retrospectively reviewed the medical records of 154 mutiple rib fracture patients who visited our hospital between January 2005 and December 2007. The medical records were reviewed for sex, age, mechanism of injury, location, number of fractures, distance of dislocated rib fragments, and presence of complications. We measured the distance of bony dislocations by using the PACS (Picture Archiving and Communication System). Results: The average number of rib fractures was $3.7{\pm}2.1$, and the number of rib fractures significantly influenced the incidence of a hemothorax (p<0.001). The risk of a hemothorax was increased in a bilateral MRF compared to a unilateral MRF (p=0.027). The distance of dislocated rib fragments influenced the probability of a hemothorax significantly (p=0.018), and subcutaneous emphysema and lung contusion were significantly associated with a pneumothorax (p=0.021, p=0.036). Conclusion: The number of MRFs did not influence the risk for a pneumothorax, but did influence the risk for a hemothorax. The laterality, distance of dislocation, also had an influence on the risk for a hemothorax. Also, subcutaneous emphysema and lung contusion were increased in cases with a pneumothorax. We must consider the possibility of a hemothorax even when the initial chest X-ray shows no evidence of a hemothorax. If a lung contusion is present, then an occult pneumothorax must be considered.

Preliminary Ecological Environmental Assessments of a Brooklet in Jeungchon (증촌 도랑의 생태환경 조사와 평가)

  • Han, Jeong-Ho;An, Kwang-Guk
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.6
    • /
    • pp.841-857
    • /
    • 2012
  • Preliminary ecological environmental assessments including physico-chemical constituents, water quality, fish fauna analysis, physical habitat health, and ecological health assessment were conducted as a primary step for Jeungchon micro-habitat ecosystem restoration in 2012. Water chemistry analysis of conductivity, dissolved oxygen, chlorophyll-a and etc. indicated that there were no significant differences(p < 0.05) among 6 sites between the headwaters and downstream. Multi-metric model analysis of Qualitative Habitat Evaluation Index(QHEI) showed that brooklets were at "good condition" as a mean QHEI of 158.7(n = 6) and the longitudinal differences of the model values between the sites were minor(QHEI range: 153 - 165). Total fish species and the number of individuals were 12 and 481, respectively, and dominant species were Zacco platypus(49.5%) and Zacco koreanus(36.8%). Tolerance guild analysis showed that the proportion of sensitive species($S_S$) had a negative linear function[$S_S=86.35-0.31(D_H)$; $R^2$ = 0.892, p < 0.01] with a distance from the headwaters, while the proportion of tolerant species($T_S$) had a positive linear function($R^2$ = 0.950, F = 90.28, p < 0.001) with the distance. Trophic feeding guild analysis showed that the proportion of insectivore species($I_n$) had a negative linear function($R^2$ = 0.934, p < 0.01) with a distance from the headwaters, while the proportion of omnivore species($O_m$) had a positive linear function($R^2$ = 0.958, p < 0.001) with the distance. Index of Biological Integrity(IBI) model, based on fish assemblages, showed a "fair condition" as a mean IBI of 23(n = 6), and there was a distinct differences of ecological health between the headwaters(S1 = 30; "good condition") and the downstreams(S6 = 14; "poor condition"). Overall, the preliminary environmental impact assessments suggest that water quality, physical habitat conditions(QHEI model), and ecological health(IBI model) were maintained well, even if the state was not an excellent conditions.

Evaluation of the Changes in Polymerization of TheraCal LC with Various Light-curing Time and Distance (광중합 시간과 거리의 변화에 따른 TheraCal LC의 중합도 평가)

  • Bae, Sangyong;Lee, Jewoo;Ra, Jiyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.4
    • /
    • pp.392-399
    • /
    • 2019
  • The purpose of this study was to evaluate polymerization of TheraCal LC, one of the tricalcium silicate cements. To measure the Vickers hardness number (VHN), the specimens were cured at different light curing time and distance. As a result, the VHN of the upper surface was significantly higher than the lower surface's in all groups (p < 0.05). The VHN of the lower surface was increased significantly with the increase of the light curing time in all distance (p < 0.05). When the distance was more than 4.0 mm at all light curing time, the VHN of lower surface was significantly decreased (p < 0.05). When the specimen was light cured for 20 seconds, the VHN of the lower surface did not exceed 2, which corresponds to 10% of the upper surface's. These results suggested that the 20 second light curing time was not sufficient to polymerize the lower surface under specific conditions and that light-curing time should be increased.

Net Center of Pressure Analysis during Gait Initiation Patient with Hemiplegia : a pilot study (편마비 환자의 보행시작 시 총 압력중심 변화 : 사전연구)

  • Hwang, S.H.;Park, S.W.;Choi, H.S.;Kim, Y.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.1
    • /
    • pp.50-55
    • /
    • 2010
  • Gait initiation is a transitional process from the balanced upright standing to the beginning of steady-state walking. Dysbalanced gait initiation often causes stroke patients to fall. The net center of pressure, measured by two triaxial force plates from twenty healthy subjects and two stroke patients, was investigated to assess asymmetry of gait initiation in hemiparetic subjects. The time interval and distance of the net center of pressure(CoP) moved from the initiation point to the toe off(S1) and from the toe off to the initial contact(S2) were calculated during gait initiation of normal and stroke patients. When the patient with right hemiplegia(A) initiated his gait with right foot, the time interval and the distance of the net CoP in S1 and S2 were smaller than that of normal subjects' values. However, he initiated the gait with left foot(unaffected side) the time interval and the distance of net CoP in S1 were larger than normative values. Differently, the patient with left hemiplegia(B) has shown that larger time interval and distance in S1 and smaller time interval and distance in S2 in both sides. His asymmetry(with which side the gait initiated) was not significant. It is too early to conclude that these results could be general characteristics of the stroke patients because the variations were large and moreover, the level of motor recovery of the patients was different. However, it is expected that these trials could help to set up the strategy of the therapy for the rehabilitation or prevention of fall in stroke patients.

A STUDY ON DIMENSIONAL STABILITY OF IMPRESSION MATERIALS FOLLOWING IMMERSION DISINFECTION (수종 인상재의 침지 소독이 경석고 모형의 크기 안정성에 미치는 영향에 관한 연구)

  • Song, Ki-Yong;Yang, Jae-Ho;Lee, Sun-Hyung;Chung, Hun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.506-515
    • /
    • 1999
  • Dental practice can produce and spread some infectious diseases from patients to dentist, dental assistant, and dental labors. One possible method for preventing these cross-contamination is to immerse dental impression in chemical disinfectants. So for many investigators studied on the dimensional changes of dental impressions and on the surface qualities of stone casts made from impression following immersion in disinfectants. This study was proposed to evaluate some popular impression disinfectant combination from the point of dimensional stability. Impression was taken from dental arch-shaped metal model. Irreversible hydrocolloid and 3 elastomers(polyvinyl siloxane, polysulfide, polyether) were immersed in 3 disinfectants (2% glutaraldehyde, 1% povidone-iodine, 0.5% sodium hypochlorite) for 10 minutes and measured both cross-arch and anterior-posterior distance under stereo microscope to evaluate dimensional change. The results obtained were as follows: 1. Dimensional changes of irreversible hydrocolloid impression was statistically different in cross-arch and anterior-posterior distance when immersed in 2% glutaraldehyde solution and in anterior-posterior distance when immersed in 0.5% sodium hypochlorite solution from control group (p<0.05). 2. Dimensional changes of polyvinyl siloxane and polysulfide impression were not statistically different from control group (p>0.05). 3. Dimensional changes of polyether impression was statistically different in cross-arch distance when immersed in 0.5% sodium hypochlorite solution and in anterior-posterior distance when immersed in 1% povidone-iodine solution from control group (p<0.05). 4. In all cases, dimensional changes were less than 0.1% from the original dimension and concluded clinically acceptable.

  • PDF

Core-Collapse Supernovae in Spiral Galaxy M74 and the Hubble Constant

  • Jang, In Sung;Lee, Myung Gyoon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.68.1-68.1
    • /
    • 2014
  • M74 is a nearby face-on spiral galaxy that hosts three core-collapse supernovae (SNe) : SN Ic 2002ap, SN II-P 2003gd, and SN II-P 2013ej. Therefore it is an ideal target to investigate the properties of the core-collapse SNe and to improve the calibration of Type II-P SNe as a standardizable candle. However, its distance is not well known. We present a new distance estimate to M74 based on the tip of the red giant branch (TRGB). From the photometry of archival F555W and F814W images taken with the Hubble Space Telescope, we derive the TRGB to be at $ITRGB=26.13{\pm}0.02$ and the distance modulus to be $30.04{\pm}0.04$ (random) ${\pm}0.12$ (systematic) (corresponding to a linear distance, $10.19{\pm}0.14{\pm}0.56Mpc$). With this result, we calibrate the standardized candle method of SNe II-P. From the absolute magnitude of SN 2003gd corrected for its expansion velocity and reddening, we derive the value of the Hubble constant, $H0=72{\pm}6{\pm}7km\;s-1\;Mpc-1$. It is in agreement with the uncertainty with the recent estimates based on the luminosity calibration of Type Ia SNe.

  • PDF

A Study on Performance Enhancement of Distance Relaying by DC Offset Elimination Filter (직류옵셋제거필터에 의한 거리계전기법의 성능 개선에 관한 연구)

  • Lee, Kyung-Min;Park, Yu-Yeong;Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.2
    • /
    • pp.67-73
    • /
    • 2015
  • Distance relay is widely used for the protection of long transmission line. Most of distance relay used to calculate line impedance by measuring voltage and current using DFT. So if there is a computation error due to the influence of phasor by DC offset component, due to excessive vibration by measuring line impedance, overreach or underreach can be occurs, and then abnormal and non-operation of distance relay can be issue. It is very important to implement the robust distance relaying that is not affected by DC offset component. This paper describes an enhanced distance relaying based on the DC offset elimination filter to minimize the effects of DC offset on a long transmission line. The proposed DC offset elimination filter has not need any prior information. The phase angle delay of the proposed DC offset filter did not occurred and the gain error was not found. The enhanced distance relay uses fault current as well as residual current. The behavior of the proposed distance relaying using off-line simulation has been verified using data about several fault conditions generated by the ATP simulation software.

Relationship of Fixation Disparity and Heterophoria According to Fixation Distance (원, 근거리에서 주시시차와 사위와의 관계)

  • Kim, Chang-Jin;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.79-87
    • /
    • 2008
  • Purpose: This study measured Y-intercept that means a fixation disparity, X-intercept that means a associated phoria and slope of a fixation disparity curve (FDC), which are variables of dissociated phoria and the FDC. We searched for the result value and examined the direction, distribution pattern and a variable that give an most affect on dissociated phoria and the FDC at distance and near. Also this study examined that there were statistically significant differences between distance and near, comparing the result value. Methods: We measured the dissociated phoria and the fixation disparity for 51 subjects at distance and near in June, 2007. All subjects ranged from 20 to 25 years of age (average 21.72${\pm}$1.88 years old) and had no eye disease. At distance the dissociated phoria measured with the distance MIM card (muscle imbalance measure card, Bernell co., USA), and the fixation disparity measured with the modified Mallett Far Unit (Bernell co., USA). At near the dissociated phoria measured with the near MIM card (muscle imbalance measure card, Bernell co., USA), and the fixation disparity measured with the Wesson fixation disparity card (American Optical co., USA). Results: The percentage distribution of types of fixation disparity curves was that at distance prevalence of Type I (74.6%) was the highest, followed by Type IV (17.6%) and Type II (3.9%), Type III (3.9%) and that at near prevalence of Type I (53.0%) was the highest, followed by Type III (29.4%), Type IV (13.7%) and Type II (3.9%). 2. There were significantly correlation in dissociated phoria, fixation disparity (Y-intercept) and associated phoria (X-intercept). 3. The fixation disparity at distance was most affected by associated phoria (X-intercept) (p=0.000). The distance dissociated phoria was most affected by fixation disparity (Y-intercept) (p=0.342), but the influence was weak. 4. The fixation disparity at near was most affected by associated phoria (X-intercept) (p=0.000). The near also dissociated phoria was most affected by associated phoria (X-intercept) (p=0.009). The result that compared the each variables with the same variables at distance and near had statistically significant on paired t-test for among dissociated phoria (t=7.529, p=0.000), X-intercept (t=5.860, p=0.000), the Y-intercept (t=4.640, p=0.000) but slope of the FDC did not differ significant (t=1.336 p=0.188). Conclusions: Relationship of fixation disparity and Heterophoria had close correlation at distance and near.

  • PDF