• Title/Summary/Keyword: K2P distance

Search Result 1,048, Processing Time 0.034 seconds

The Study of Distance and Near AC/A Ratio by Stimulus (조절자극 방식에 따른 원거리와 근거리 AC/A비에 관한 연구)

  • Jo, Tae-Sik;Kim, In-Suk;Jang, Jung-Un
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.417-423
    • /
    • 2011
  • Purpose: This study was to investigate that near gradient AC/A ratio could be used to prescribe a patient with distance exophoria, we compared the difference between distance gradient AC/A ratio and near gradient AC/A ratio. Also, this thesis was to understand the relationship between calculated AC/A ratio and gradient AC/A ratio. Methods: Objective and subjective refractive error were corrected and we used Howell (3 m) chart for distance phoria tests and Howell-Kim (40 cm) chart for near phoria tests. The near gradient AC/A ratio and calculated AC/A ratio were used by Howell-Kim (40 cm) combined with +1.00 D, -1.00 D, +2.00 D and -2.00 D. Results: The average value of distance exophoria was 1.17${\pm}$1.17 $\Delta$, and the average value of near exophoria was 3.71${\pm}$2.80 $\Delta$ (t-test. p<0.001). The correlation of distance phoria with near phoria was little higher (r = 0.59, p < 0.001). Gradient AC/A ratios depending on measuring distance and stimulus were higher (r = 0.11~0.53. P < 0.001), when distance was shorter and stimulus to accommodation was more. Also, stimulus to accommodation by plus lens was higher than stimulus to accommodation by minus lens (paired t-test. p < 0.001). There was negative correlation between calculated AC/A ratio and gradient AC/A ratio. As the calculated AC/A ratio was higher, gradient AC/A ratio was lesser. Near gradient AC/A ratio was slightly higher than distance gradient AC/A ratio. Distance and near gradient AC/A ratio taken through the subjective -1.00 D were 1.30 $\Delta$/D and 1.68 $\Delta$/D(t-test. t=1.67, p < 0.001). Conclusions: There is negative correlation between calculated AC/A ratio and gradient AC/A ratio. Also, there is subtle difference between near gradient AC/A ratio and distance gradient AC/A ratio. Therefore, we need to measure distance gradient AC/A ratio when a practitioner prescribe glasses for a patient with distance exophoria.

DEPENDENCY OF SINGLE-PHASE FAC OF CARBON AND LOW-ALLOY STEELS FOR NPP SYSTEM PIPING ON PH, ORIFICE DISTANCE AND MATERIAL

  • Moon, Jeong-Ho;Chung, Hung-Ho;Sung, Ki-Woung;Kim, Uh-Chul;Rho, Jae-Seong
    • Nuclear Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.375-384
    • /
    • 2005
  • To investigate the flow-accelerated corrosion (FAC) dependency of carbon steel (A106 Gr. B) and low-alloy steels (1Cr-1/2Mo, 21/4Cr-1Mo) on pH, orifice distance, and material, experiments were carried out. These experiments were performed using a flow velocity of 4 m/sec (partly 9 m/sec) at pH $8.0\~10.0$ in an oxygen-free aqueous solution re-circulated in an Erosion-Corrosion Test Loop at $130^{\circ}\;{\ldots}$ for 500 hours. The weight loss of the carbon steel specimens appeared to be positively dependent on the flow velocity. That of the carbon and low-alloy steel specimens also showed to be distinguishably dependent on the pH. At pH levels of $8.0\~9.5$ it decreased, but increased from 9.5 to 10.0. Utility water chemistry personnel should carefully consider this kind of pH dependency to control the water system pH to mitigate FAC of the piping system material. The weight loss of the specimens located further from the orifice in the distance range of $6.8\~27.2$ mm was shown to be greater, except for 21/4Cr-1Mo, which showed no orifice distance dependency. Low alloy steel specimens exhibited a factor of two times better resistance to FAC than that of the carbon steel. Based on this kind of FAC dependency of the carbon and low-alloy steels on the orifice distance and material, we conclude that it is necessary to alternate the composition of the secondary piping system material of NPPs, using low-alloy steels, such as 21/4Cr-1Mo, particularly when the system piping has to be replaced.

Evaluating different interrow distance between corn and soybean for optimum growth, production and nutritive value of intercropped forages

  • Kim, Jeongtae;Song, Yowook;Kim, Dong Woo;Fiaz, Muhammad;Kwon, Chan Ho
    • Journal of Animal Science and Technology
    • /
    • v.60 no.2
    • /
    • pp.1.1-1.6
    • /
    • 2018
  • Background: Maize fodder is being used as staple feed for livestock but it lacks protein and essential amino acids; lysine and tryptophan. Intercropping maize with leguminous soybean crop is promising technique under limited land resources of South Korea but it can only give considerable advantages when adequate distance is provided between corn and soybean rows. Main aim of present study was to find-out adequate distance between corn and soybean seeding rows for optimum growth, yield and nutritive value of intercropped forage. Methods: Different interrow distances between corn and soybean were evaluated under four treatments, viz. 1) Corn sole as positive control treatment 2) Zero cm between corn and soybean (control); 2) Five cm between corn and soybean; 3) 10 cm between corn and soybean, with three replicates under randomized block design. Results: Findings depicted that height and number of corn stalks and ears were similar (P > 0.05) among different treatments. Numerically average corn ear height was decreased at zero cm distance. Dry matter percentage in all components; corn stalk, corn ear and soybean was also found not different (P > 0.05) but dry matter yield in component of corn ear was lower (P < 0.05) at zero cm distance as compared to that of 5 and 10 cm interrow distances. In case of nutritive value, total digestible nutrient yield in intercropped corn was also found lower (P < 0.05) at zero cm distance than that of 5 and 10 cm interrow distances between corn and soybean seeding rows. Substantial decrease in dry matter yield of maize ear at zero cm distance might be attributed to factor of closed interrow spacing which made interplant competition more intensified for light interception, necessary for photosynthetic activity. Lower dry matter yield in ear also reduced total digestible nutrients in intercropped maize because it was determining factor in calculation of digestible nutrients. The optimum yield and nutritive value of forage at wider interrow distance i.e. 5 cm between corn and soybean might be due to adequate interseed distance. Conclusion: Conclusively, pattern of corn and soybean seeding in rows at 5 cm distance was found suitable which provided adequate interrow distance to maintain enough mutual cooperation and decreased competition between both species for optimum production performance and nutritive value of intercropped forage.

Evaluation of Visual Responses in Viewing a 3D Image (3D 영상 시청 시 시각반응의 평가)

  • Lee, Mu-Hyuk;Son, Jeong-Sik;Kim, Jaedo;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.165-170
    • /
    • 2012
  • Purpose: The aim of this study was to measure and evaluate changes of visual responses in viewing a 2D and 3D (three-dimensional) image. Methods: The subjects were 44 college students aged 19 to 25 years with normal binocular vision. The visual responses measured were CA/C (convergence accommodation/convergence) ratio, convergence-induced PD(interpupillary distance), accommodative responses, perceived distance in viewing a 3D image. Results: Convergence and accommodative responses in viewing the 3D image were significantly larger (p<0.05) than in 2D. A moderate positive correction was found between CA/C ratio and accommodative response (r = 0.477, p = 0.001). It was indicated that smaller PD had larger depth perception. Convergence in viewing the 3D image was significantly larger (p<0.05) than that at cognitive distance. Conclusions: The visual fatigue may be more intense in larger CA/C ratio and smaller PD when viewing 3D images.

Graphic Method of Visual Analysis and Norms Determination for the Far Distance Phoria (원거리사위별 그래프 분석과 표준값 결정)

  • Joo, Seok-Hee;Park, Seong-Jong;Sim, Hyun-Seog
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.193-200
    • /
    • 2006
  • We investigated the visual analysis of the far distance phoria for 83 subjects who have emmetropia or myopia eyes, using the graphic method, and determined new norms. We got the following results from these experiments. 1. The measured norm of far distance phoria is $1.12{\Delta}$, exophoria, the that of near distance phoria is $0.50{\Delta}$, exophoria, the that of negative relative convergence at far distance(N.R.C.) is ${\times}$/11/5, the that of positive relative convergence at far distance(P.R.C.) is 10/20/8, the that negative relative convergence at near distance(N.R.C.) is 11/21/5, the that of positive relative convergence at near(P.R.C.) is 10/20/8, the that of negative relative accommodation(N.R.A.) is +2.54D, and the that of positive relative accommodation(P.R.A.) is -2.60D, respectively. We know from theses results that the measured norms of far distancet phoria is higher than Morgan's norms, while those of near distance phoria are lower than Morgan's norms. 2. We also know from these experiments that Morgan's norms are closely related to A, B, and C groups and Morgan's criterion can more usefully apply to the visual analysis. 3. In Sheard's criterion and Percival's criterion, the prism prescription is occurred when the exophoria of the far-point phoria is over $7{\sim}9{\Delta}$, and the esophoria of that is over $4{\sim}6{\Delta}$.

  • PDF

Aided Distance Visual Acuity and Refractive Error Changes by Using Smartphone (스마트폰 사용이 원거리 교정시력과 굴절 이상 변화에 미치는 영향)

  • Kim, Bong-Hwan;Han, Sun-Hee;Shin, Young Gul;Kim, Da Yeong;Park, Jin Young;Sin, Won Chul;Yoon, Jeong Ho
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.305-309
    • /
    • 2012
  • Purpose:This study was conducted to research any effect on aided distance visual acuity and refractive error changes by using smartphone at near for long term. Methods: 20($20.6{\pm}0.9$ years) young adults subjects with no ocular diseases, over 0.8 of aided distance visual acuity, normal amplitude of accommodation and normal accommodative facility agreed to participate in this study. The subjects were divided into two group, Group 1 (15 cm fixation distance) included 10 subjects and Group 2(40 cm fixation distance) included 10 subjects. Aided distance visual acuity and refractive error were measured before and after using smartphone for 30 minutes by auto-chart project (CP-1000, Dongyang, Korea), phoropter (VT-20, Dongyang, Korea), auto refractor-keratometer (MRK-3100, Huvitz, Korea). After then, the subjects looked at distance with wearing spectacles. Refractive error was measured at 5 minutes, 10 minutes, and 15 minutes later, respectively. Results: After using smartphone at 15 cm for 30 minutes, there was statistically significant reduction of aided distance visual acuity (p=0.030) and increasing myopia (p=0.001). The increased myopia was not statistically significant after 5 minutes rest (p${\geq}$0.464). However there was no statistically significant changes in aided distance visual acuity (p=0.163) and refractive error (p=0.077) after using smartphone at 40 cm for 30 minutes. Conclusions: It is recommend to keep 40 cm off the smartphone from eyes to avoid any aided distance visual acuity and refractive error changes. If smartphone is used closer than 40 cm, a rest for 5 minutes is also recommend after every 30 minutes use with smartphone to avoid any aided distance visual acuity and refractive error changes.

A Study on Accuracy in Determining the Hinge Axis Location (접번축(蝶番軸) 위치(位置) 결정시(決定時)의 정밀성(精密性)에 대(對)한 연구(硏究))

  • Kim, Choon-Ho;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.24 no.1
    • /
    • pp.17-26
    • /
    • 1986
  • The purpose of this study was to investigate true hinge axis location with different times (8:00-9:00 A.M.,2:00-3:00 P.M.) and with experienced and inexperienced groups. 25 subjects, 23-27 years of age , with functionally acceptable occlusion, and no clinical signs of temporomandibular joint dysfunction were participated in this study. In this study arbitrary hinge axis point was located 13 mm anterior to the posterior margin of the tragus on a line from the center of the tragus to the outer canthus of the eye and then the true hinge axis point was located with T.M.J. hinge axis locator. The discrepancies of distance and the direction between true hinge axis point and arbitrary hinge axis point were studied according to times and two groups. The results obtained were as follows : 1. The mean distance from arbitrary hinge axis point to the true hinge axis point on the right and left sides was as follows : Experienced group: linear distance: $1.228{\pm}3.145mm$, vertical distance: $-1.128{\pm}2.515mm$, horizontal distance: $-0.484{\pm}1.806mm$. Inexperience group: linear distance: $1.628{\pm}3.158mm$, vertical distance: $-1.169{\pm}2.090mm$, horizontal distance: $-1.133{\pm}2.367mm$. Horizontal distance between experienced and inexperienced groups was significant statistically. (P<0.1) 2. True hinge axis points located within 5 mm of arbitrary hinge axis point were 86.7% in the experienced group and 84% in the inexperienced group. 3. For experienced operator A with time, the mean distance from arbitrary hinge axis point to true hinge axis point was as follows: Horizontal distance: AM: $-0.613{\pm}1.966mm$, PM: $-0.860{\pm}2.156mm$. Vertical distance: AM: $-0.886{\pm}2.518mm$, PM : $-1.226{\pm}2.660mm$. True hinge axis points had tendency to be located posterior-inferiorly to tragus-canthus line in the afternoon than in the morning, but there was not significant statistically. (P>0.1)

  • PDF

Comparison of Three-dimensional Kinematic Changes of the Lower Extremity between the Two Different Braking Distances of Snowplow in Alpine Skiing

  • Kim, Joo-Nyeon;Kim, Jin-Hae;Ryu, Jiseon;Yoon, Sukhoon;Park, Sang-Kyoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.4
    • /
    • pp.361-367
    • /
    • 2016
  • Objective: The aim of this study was to compare three-dimensional kinematic changes of the lower extremity between the two different braking distances during snowplow in alpine skiing. Method: Six alpine ski instructors (age: $25.3{\pm}1.5yr$, height: $169.3{\pm}2.9cm$, weight: $66.2{\pm}5.9kg$, career: $4.2{\pm}2.9yr$) participated in this study. Each skier was asked to perform snowplow on the two different braking distances (2 and 4 m). Results: Snowplow and edging angles (p = .006 and p = .005), ankle adduction and inversion (p = .033 and p = .002), knee extension (p = .003), and hip abduction and internal rotation (p = .043 and p = .006) were significantly greater in the 2 m than in the 4 m braking distance. Conclusion: Based on our results, we suggest that skiers should make greater snowplow and edging angles on the shorter braking distance. In this situation, ankle joint adduction/inversion angle and hip joint internal-rotation make greater snowplow angle, and hip joint abduction make greater edging angle. In addition, greater knee joint extension angle may lead to more posteriorly positioned center of mass.

L(4, 3, 2, 1)-PATH COLORING OF CERTAIN CLASSES OF GRAPHS

  • DHANYASHREE;K.N. MEERA
    • Journal of applied mathematics & informatics
    • /
    • v.41 no.3
    • /
    • pp.511-524
    • /
    • 2023
  • An L(p1, p2, p3, . . . , pm)-labeling of a graph G is an assignment of non-negative integers, called as labels, to the vertices such that the vertices at distance i should have at least pi as their label difference. If p1 = 4, p2 = 3, p3 = 2, p4 = 1, then it is called a L(4, 3, 2, 1)-labeling which is widely studied in the literature. A L(4, 3, 2, 1)-path coloring of graphs, is a labeling g : V (G) → Z+ such that there exists at least one path P between every pair of vertices in which the labeling restricted to this path is a L(4, 3, 2, 1)-labeling. This concept was defined and results for some simple graphs were obtained by the same authors in an earlier article. In this article, we study the concept of L(4, 3, 2, 1)-path coloring for complete bipartite graphs, 2-edge connected split graph, Cartesian product and join of two graphs and prove an existence theorem for the same.

Influence of Multicultural contact Experience on the Relationship between Social Distance and Multicultural Acceptance among Nursing Students. (간호대학생의 사회적거리감과 다문화수용성의 관계에서 다문화접촉경험의 영향)

  • Noh, Yoon Goo;Lee, Oi Sun
    • Journal of Digital Convergence
    • /
    • v.16 no.1
    • /
    • pp.187-195
    • /
    • 2018
  • The purpose of this study was to identify the moderated effects of multicultural contact experience on the relationship between social distance and multicultural acceptability among nursing students. The sample for this study consisted of 174 nursing students from four universities located in Korea. Data were analyzed by descriptive statistics, t-test, ANOVA, $Scheff{\acute{e}}$ test, Pearson correlation and hierarchical multiple regression with SPSS/WIN 23.0. It was found that: (a) multicultural acceptability had a negative correlation with social distance(r=-.61, p<.001), whereas a positive correlation was observed with experience of multicultural contact(r=.24, p=.002); (b) the interaction effect by multicultural contact experience and social distance had a significant influence on the multicultural acceptability(${\beta}=-.18$, p=.003); (c) experience of multicultural contact moderated the relationship between social distance and multicultural acceptability(${\Delta}R^2=0.30$, p=.003). Results of the study suggest that the greater the experience of multicultural contact, the greater the negative effect of social distance on multicultural acceptability. Therefore, to increase the multicultural acceptability of nursing students, it is important to encourage the positive experiences of multicultural contact and thus reduce social distance.