• Title/Summary/Keyword: K-stability

Search Result 20,078, Processing Time 0.049 seconds

Dynamic Analysis of an Automatic Ball Balancer with Triple Races (삼중레이스를 갖는 자동평형장치의 동적 해석)

  • Jwa, Seong-Hun;Jo, Eun-Hyeong;Son, Jin-Seung;Park, Jun-Min;Jeong, Jin-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.4
    • /
    • pp.764-774
    • /
    • 2002
  • Dynamic behaviors are analyzed for an automatic ball balancer (ABB) with triple races, which is a device to reduce the unbalanced mass of optical disk drives (ODD) such as CD-ROM or DVD drives. The nonlinear equations of motion are derived by using Lagrange's equations with the polar coordinate system. It is shown that the polar coordinate system provides the complete stability analysis while the rectangular coordinate system used in other previous studies has limitations on the stability analysis. For the stability analysis, the equilibrium positions and the linearized perturbation equations are obtained by the perturbation method. Based on the linearized equations, the stability of the system is analyzed around the equilibrium positions; furthermore, to confirm the stability, the time responses for the nonlinear equations of motion are computed by using a time integration method and experimental analyses are performed. Theoretical and experimental results show a superiority of the ABB with triple races.

Fusion Peptide Improves Stability and Bioactivity of Single Chain Antibody against Rabies Virus

  • Xi, Hualong;Zhang, Kaixin;Yin, Yanchun;Gu, Tiejun;Sun, Qing;Shi, Linqing;Zhang, Renxia;Jiang, Chunlai;Kong, Wei;Wu, Yongge
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.4
    • /
    • pp.718-724
    • /
    • 2017
  • The combination of rabies immunoglobulin (RIG) with a vaccine is currently effective against rabies infections, but improvements are needed. Genetic engineering antibody technology is an attractive approach for developing novel antibodies to replace RIG. In our previous study, a single-chain variable fragment, scFv57R, against rabies virus glycoprotein was constructed. However, its inherent weak stability and short half-life compared with the parent RIG may limit its diagnostic and therapeutic application. Therefore, an acidic tail of synuclein (ATS) derived from the C-terminal acidic tail of human alpha-synuclein protein was fused to the C-terminus of scFv57R in order to help it resist adverse stress and improve the stability and half-life. The tail showed no apparent effect on the preparation procedure and affinity of the protein, nor did it change the neutralizing potency in vitro. In the ELISA test of molecular stability, the ATS fusion form of the protein, scFv57R-ATS, showed an increase in thermal stability and longer half-life in serum than scFv57R. The protection against fatal rabies virus challenge improved after fusing the tail to the scFv, which may be attributed to the improved stability. Thus, the ATS fusion approach presented here is easily implemented and can be used as a new strategy to improve the stability and half-life of engineered antibody proteins for practical applications.

Investigation of muscle-specific beef color stability at different ultimate pHs

  • Wu, Shuang;Han, Jina;Liang, Rongrong;Dong, Pengcheng;Zhu, Lixian;Hopkins, David L.;Zhang, Yimin;Luo, Xin
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.12
    • /
    • pp.1999-2007
    • /
    • 2020
  • Objective: This study was aimed to investigate the muscle-specific beef color stability at normal and high ultimate pHs. Methods: The impact of muscle (Longissimus lumborum [LL] vs psoas major [PM]) and pH (normal ultimate pH [Np] vs high pH dark cutting beef [Hp]) on color stability, indicated by basic color traits, metmyoglobin reducing activity (MRA) and oxygen consumption (OC), as well as the lipid oxidation, were determined over 7 days of display at 4℃. Results: Hp-LL had the highest pH (6.92), followed by Hp-PM (6.01), Np-PM (5.76), and Np-LL (5.52). Hp-LL had increased (p<0.05) a, chroma and % oxymyoglobin during display. Hp-LL also had the highest metmyoglobin (MMb) reducing activity and OC among all the samples, thus, the greatest color stability, although very dark throughout storage, with lowest values for lightness (L) and yellowness (b). Np-LL also exhibited relatively high color stability, as a result of its lower % MMb and OC and higher MRA than psoas muscle samples. The 0.2 unit difference of the pH between Hp and Np psoas muscle, resulted in the difference of the color intensity, not the color stability. Interestingly, high pH psoas muscle (Hp-PM) did not have better color stability than Np-PM, and in fact had lower color stability than even Np-LL. The similar level of OC and lipid oxidation cannot explain the difference in color stability between Hp-PM and Np-LL. Conclusion: The Hp does not always show better color stability compared with Np beef, which depends on the muscle type. The balance of MRA and OC is important to keep the color in great intensity and stability in the meantime.

Extreme Learning Machine Approach for Real Time Voltage Stability Monitoring in a Smart Grid System using Synchronized Phasor Measurements

  • Duraipandy, P.;Devaraj, D.
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1527-1534
    • /
    • 2016
  • Online voltage stability monitoring using real-time measurements is one of the most important tasks in a smart grid system to maintain the grid stability. Loading margin is a good indicator for assessing the voltage stability level. This paper presents an Extreme Learning Machine (ELM) approach for estimation of voltage stability level under credible contingencies using real-time measurements from Phasor Measurement Units (PMUs). PMUs enable a much higher data sampling rate and provide synchronized measurements of real-time phasors of voltages and currents. Depth First (DF) algorithm is used for optimally placing the PMUs. To make the ELM approach applicable for a large scale power system problem, Mutual information (MI)-based feature selection is proposed to achieve the dimensionality reduction. MI-based feature selection reduces the number of network input features which reduces the network training time and improves the generalization capability. Voltage magnitudes and phase angles received from PMUs are fed as inputs to the ELM model. IEEE 30-bus test system is considered for demonstrating the effectiveness of the proposed methodology for estimating the voltage stability level under various loading conditions considering single line contingencies. Simulation results validate the suitability of the technique for fast and accurate online voltage stability assessment using PMU data.

Dynamic Stability Effect of Applicable Core and Neuromuscular Training for 12 Weeks (12주간 적용 가능한 코어, 신경근 훈련의 동적 안정성 효과)

  • Kim, Kyoung-Hun;Lee, Sung-Cheol
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.1
    • /
    • pp.101-108
    • /
    • 2010
  • Recently, core and neuromuscular training(CNT) is emerging as a clinically relevant tool to improve neuromuscular control and to prevent sports injuries. The purpose of this study was to examine the effect of a 12 weeks CNT program on the dynamic stability after drop landing. The subjects attempted drop landing onto the force platform on single foot from a 40 cm height distance. The collected data was used to calculate the dynamic stability index. The Dynamic stability index was derived by measuring the medial-lateral stability index(MLSI), anterior-posterior stability index(APSI), and the vertical stability index(VSI). In comparison to the control group, the MLSI and APSI showed no difference, yet, it resulted in higher VSI. The results of this study suggest that CNT is worthwhile to be considered as a way to improve neuromuscular control and to prevent traumatic injuries. However, the results are taking into consideration to discuss the limitations of CNT and suggested future approaches.

Dimensional Stability of Plastic Processing Wood Material - Compression Wood and Bentwood -

  • Hwang, Kweon-Hwan;Lee, Won-Hee
    • Journal of the Korea Furniture Society
    • /
    • v.18 no.2
    • /
    • pp.143-146
    • /
    • 2007
  • This study was carried out to assess the dimensional stability of wood material treated by plastic processing for bentwood and compression wood. The evaluation method was different between two wood materials, but the treatments for them were very similar to each other. One of the main methods is heat treatment with sufficient water vapor. In bentwood, the used species were painted maple (Acer mono), bitter wood (Picrasma quassioides) and birch (Betula schmidtii). Steaming was the worst treatment method for dimensional stabilization of bentwood. The best results could be attained with PEG treatment for dimensional stabilization of bentwood. Dimensional stability of bitter wood was found to be conspicuous. However the steaming treatment at lower temperatures, i.e., about $130^{\circ}C$ was not suitable for dimensional stability of bentwood. In compression wood, the used specimen was Italian poplar wood (Populus euramericana). Two heat compressive pressing conditions, an open-press system and an air-tighten closed-press system, were used. The recovery rate was measured after boiling and/or absorbing in water to estimate the dimensional stability of heat compressed wood. The best dimensional stability of compressed wood in the air-tighten closed-press system was found to be better at $200^{\circ}C$ than $180^{\circ}C$. The best compression rate for dimensional stability was 73 percent.

  • PDF

Stability of Paeoniflorin used as Anti-wrinkle Agents in Emulsions (피부 주름 개선 소재인 페오니플로린의 에멀젼 안정성)

  • Cho, Wan-Goo;Kyung, Kee-Youl;Yu, Sang-Mun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.191-198
    • /
    • 2009
  • We have tested the stability of paeoniflorin, a new cosmetic ingredient, extracted from the roots of Paeoniae lactiflora. The stability of aqueous paeoniflorin solution at pH 3, 5 and 7 varied by adding buffer solution was tested at $0^{\circ}C,\;25^{\circ}C,\;40^{\circ}C,\;and\;65^{\circ}C$. The test was performed with or without UV light. The solution of paeoniflorin was stable at pH 3.0, however, the recovery rate of paeoniflorin was 40% at pH 7.0. The stability of paeoniflorin solution was decreased as the pH of paeoniflorin solution was increased by pH 7.0. The effect of storage temperature of paeoniflorin solution shows that the stability of paeoniflorin solution was decreased as the temperature was increased. The stability of paeoniflorin was rather good under UV light than the condition given above $40^{\circ}C$. The stability of paeoniflorin in W/O emulsions shows similar pattern to that of aqueous solution.

A Study on the Color Stability of Temporary Resins according to Polymerizing Methods and Staining (온성 방법에 따른 수종의 임시 수복용 레진의 착색시의 색 안정성에 관한 연구)

  • Park, Sung-Ho;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.1
    • /
    • pp.1-11
    • /
    • 2000
  • Dental temporary resin should have adequate strength and similar esthetics as natural teeth. Recently esthetics has become a high priority in clinical dentistry. Thus the evaluation of color stability of dental temporary resin has become an important part in dental research. The purpose of this study was to evaluate the difference in color stability of 3 resins($Snap^{(R)}$, Temporary bridge $resin^{(R)}$, Trim $II^{(R)}$) according to polymerizing methods and stainning. The resins were divided into groups by 2 types of polymerizing methods ( air or pressure and heat curing) The resins were dyed with coffee, chlorhexidine and artificial saliva and then the color stability was evaluated with a spectrophotometer(CM-503i, Minolta, Japan). The results were as follows ; 1. In the color stability according to polymerizing method, pressure and heat polymerizing method was higher than air polymerizing method. 2. The color stability according to staining fluid decreased in the order of I, II, III group, there was significant difference among the groups of staining fluid. 3. The color stability according to resins decreased in the order of $Snap^{(R)}$, Trim $II^{(R)}$, Temporary Bridge $resin^{(R)}$, The $Snap^{(R)}$ resin was highest color stability, there was significant difference among the 3 resins.

  • PDF

An Experimental Assessment of Combustion Stability of Coaxial Swirl Injectors and an Impinging Injector through Simulating Combustion Test (상압기상연소시험을 통한 동축형 스월 분사기와 충돌형 분사기의 연소 안정성 평가)

  • Park, Junhyeong;Kim, Hongjip
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.1
    • /
    • pp.46-52
    • /
    • 2017
  • High-frequency combustion instabilities may occur during the development of feasible engine combustors. These instabilities can result in irreparable damages to the wall of combustors or the degradation of engine performance. So, it is essential to identify injectors that have high stability characteristics during the early stages of development. The objective of present study was to assess the stability of coaxial injectors and an impinging injector with different recess lengths in order to develop stable injectors optimally. Stability margin was evaluated based on the distance from operating condition to the unstable regions. A simulating combustion test method was used to analyze the stability of injectors. A small-scale combustion chamber was designed to simulate the first tangential acoustic mode of the actual combustor. Gaseous oxygen and a mixture of methane and propane were used as simulant propellants to satisfy their flow similarity to the actual propellants of a combustor in a liquid rocket combustor. The results indicated that injectors having small recess lengths showed relatively large combustion stability margins. For the injectors of large recess lengths, instability regions with large and super-large amplitude oscillations were observed. Thus, injector with shorter recess lengths had a higher stability than that of longer one due to the different mixing processes.

Relaxing of the Sampling Time Requirement in Prove of the EDMC Stability

  • Haeri, Mohammad;Beik, Hossein Zadehmorshed
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1829-1832
    • /
    • 2004
  • Closed loop stability of Extended Dynamic Matrix Control (EDMC) is investigated for limited sampling time. Linear approximation of the sensitivity functions is employed in the derivation of the stability condition. It is shown that the closed loop system will be stable if the control moves suppression coefficient ${\lambda}$ is taken arbitrarily large. Special cases such as M=P=1 and M=1, P>1 are discussed in more details.

  • PDF