• Title/Summary/Keyword: K-file

Search Result 1,997, Processing Time 0.03 seconds

Extended Equal Service and Differentiated Service Models for Peer-to-Peer File Sharing

  • Zhang, Jianwei;Wang, Yongchao;Xing, Wei;Lu, Dongming
    • Journal of Communications and Networks
    • /
    • v.15 no.2
    • /
    • pp.228-239
    • /
    • 2013
  • Peer-to-peer (P2P) systems have proved the most effective and popular file sharing applications in recent years. Previous studies mainly focused on equal service and differentiated service strategies when peers have no initial data before their downloads. For an upload-constrained P2P file sharing system, we model both the equal service process and the differentiated service process when the initial data distribution of peers satisfies some special conditions. Moreover, we show how to minimize the time required to distribute the file to any number of peers. The proposed fluid-based models can reveal the intrinsic relations among the initial data amount, the peer set size, and the minimum last finish time. The closed-form expressions derived from the extended models can closely approximate chunk-based models and systems, especially for relatively large files. As an application of the extended models, we show how to provide differentiated service efficiently to multiple peer sets. Since no limits are imposed on the upload bandwidth of peers or the size of each peer set, we believe that our analytic process and the results achieved can provide not only fundamental insights into bandwidth allocation and data scheduling but also a helpful reference for both improving system performance and building an effective incentive mechanism for P2P file sharing systems.

Multiple Layer File Format for Safe Collaborative Design (안전한 협업 디자인 작업을 위한 다중 레이어 파일 포맷)

  • Kim, Kichang;Yoo, Sang Bong
    • The Journal of Society for e-Business Studies
    • /
    • v.18 no.4
    • /
    • pp.45-65
    • /
    • 2013
  • A design file can get larger in size as the complexity of the target object increases. A large design file may reside in a large parallel computing system, such as cloud computing systems, and many designers may work concurrently on the same design file. In such a case, it is obvious that we need some kind of protection mechanism so that each user can access only the area of the file he or she is entitled to. Two approaches can be taken for this problem: one is the traditional access control mechanisms and the other encryption techniques. We take the latter approach to ensure the safety of the file even in public domain such as clouding systems, and in this paper, we suggest an encryption scheme for a file where the file is encrypted in multi-layer so that each user is allowed to access the file only at the layer for which the user has the proper access right. Each layer of the file is encrypted with different keys and these keys are exposed only to those who have the right access permit. The paper explains the necessary file format to achieve this goal and discusses the file manipulation functions to handle this new file format.

The experimental study of the effect of the hybrid instrumentation method with ProTaper and ProFile on the change of root canal area and distance from the canal to the root surface after canal shaping. (ProTaper와 ProFile을 사용한 Hybrid instrumentation method의 근관 형성 전, 후 근관 단면적과 근관벽에서 치근외면까지 최단거리의 변화에 미치는 영향에 대한 실험적 연구)

  • Kim, Seok-Min;Park, Dong-Sung
    • The Journal of the Korean dental association
    • /
    • v.45 no.6 s.457
    • /
    • pp.362-369
    • /
    • 2007
  • The aim of this study was to investigate the effect of the hybrid instrumentation method with ProTaper and ProFile on the change of root canal area and distance from the canal to the root surface after canal shaping. The mesial canals of twenty extracted mandibular first molars having $10-20^{\circ}\Delta$ curvature were scanned using X-ray microcomputed tomography (XMCT)-scanner before root canals were instrumented. They were divided into four groups (n=10 canals ter group). In Group 1, root canals were instrumented by the step-back technique with stainless steel K-Flexofile after coronal flaring. The remainders were instrumented by the crown-down technique with, ProTaper system (Group 2), ProFile (Group 3) or ProTaper (Group 4). All canals were prepared up to size 25 at the end-point of preparation and scanned again. Pre- and post-operative cross-sectional images of 1, 3, 5, and 7 mm from the apical foramen were compared. For each level, change of cross-sectional canal are and distance to the nearest external root surface was calculated using Adobe Photoshop 6.0 and image software program. In the change of cross-sectional area, Group 4 was less than Group 2 at 3 mm and 5 mm level (p<0.05). In the difference of the distance from the canal to the root surface after canal shaping, Group 4 was least among the other groups at 7 mm level (p<0.05). According to the results, the methods using ProFile or K file only and the hybrid instrumentation technique using ProTaper and ProFile are more appropriate methods of canal preparation than ProTaper system for narrow of curved canals.

  • PDF

A USB DLP Scheme for Preventing Loss of Internal Confidential Files (내부 기밀파일 유출 방지를 위한 USB DLP 기법)

  • Shin, Gyu Jin;Jung, Gu Hyun;Yang, Dong Min;Lee, Bong Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.12
    • /
    • pp.2333-2340
    • /
    • 2017
  • Recently industry is suffering severe losses of important internal information, and most of the leaks result from the insiders. Thus, various technological counter measures are being studied in order to protect private organization information. In this paper, among various internal information leakage path protection mechanisms, we propose a technique for preventing files which are defined as confidential from being copied or moved through USB. The implemented confidential file loss prevention system is composed of both signature insert manager and confidential file detect manager. The signature insert manager allows a system administrator to insert a special pattern specifying a classified confidential file, while the confidential file detect manager protects confidential file leakage when a user attempts to move or copy a confidential file to the USB memory. This results would be contributed to reducing the damage caused by leakage of confidential files outside of the company via USB.

ROOT CANAL TREATMENT ON PRIMARY TEETH USING NICKEL-TITANIUM NOTARY FILES (회전식 nickel-titanium file을 이용한 유치의 근관치료)

  • Seo, Ju-Hee;Lee, Kwang-Hee;Kim, Dae-Eop;Yang, Kye-Sik
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.620-625
    • /
    • 2001
  • The pulpectomy or root canal treatment on primary teeth is to be done when there is evidence of chronic in flammation or necrosis in the radicular pulp. Due to the tortuous and ribbon-shaped anatomy of the primary teeth, the instrumentation of endodontic hand files and barbed broaches is not an easy procedure. Recently, many automatic Ni-Ti rotary instruments have been developed and has made endodontic treatment easier and faster. This report describes two cases of root canal treatment on primary molars using Ni-Ti rotary files. The cervical constricture was eliminated by the crown-down method, as smaller file proceeded unhindered into the apical third of the canal. In addition, the crown-down technique enhanced the efficacy of the endodontic irrigant. The use of rotary instrumentation for primary teeth seemed to be a more effective way to debride the uneven walls of primary teeth.

  • PDF

Performance Evaluation on Journaling File Systems using Iozone Tool in the Linux : Focus on read, write (리눅스에서 Iozone 도구를 이용한 저널링 파일 시스템 성능 평가 : read, write 중심으로)

  • Park, Hong-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.1
    • /
    • pp.39-46
    • /
    • 2013
  • If a file system is damaged because of the unusual system close, the system performs the consistency test using fsch and it takes long time. Especially, if it is a big file system, it will take a lot of time. The journaling file system that uses journaling technique, can reduce the restoring time because it uses meta data and it may increase the chance of restoration when restoring. The goal of this paper compared performance evaluation journaling file systems focused on the reading and writing using Iozone tool which is the kernel based benchmarking tool in linux operating system. In this paper, Ex4 which is the current basic Linux file system. is 1.28x faster than XFS file system in terms of file read performance and 1.22x faster than Ext3 file system in terms of file write performance.

Effects of ta-C Coatings on Surface Characteristics of Dental Ni-Ti Files (치과용 Ni-Ti파일의 표면특성에 미치는 ta-C코팅효과)

  • Sun-Kyun Park;Han-Cheol Choe
    • Corrosion Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.368-376
    • /
    • 2023
  • Dental Ni-Ti files must ensure stability and resistance to fatigue fracture. DLC and ta-C were coated to remove defects on the surface and ensure stability, and the surface characteristics were investigated. When coated with DLC, it was black, and in case of ta-C coating, it was blue-black. Scratches, which are defects caused by mechanical processing, were formed on the surface of the un-coated Ni-Ti file from the end of the file along the direction of processing, with the Pro-file appearing in the vertical direction and the K-file appearing in the file direction. Scratches were reduced on the coated surface, and the surface roughness was greatly reduced after coating compared to before coating. The un-coated Ni-Ti file had the lowest hardness, the DLC-coated file had the highest hardness, and ta-C showed relatively high hardness. The elastic modulus of the DLC coating film was high, and the ta-C elastic modulus was low. The adhesion of the DLC coating film tended to be higher than that of ta-C, and the wear loss amount of DLC coating of taC was lower. The corrosion potential of the ta-C coating increased significantly, and the corrosion current density decreased.

A STUDY ON TRANSPORTATION OF APICAL FORAMEN AFTER OVERINSTRUMENTATION BY PROFILE® ;PROTAPERTM AND K3TM IN SIMULATED CANALS WITH DIFFERENT CURVATURES (ProFile®, ProTaperTM 및 K3TM Ni-Ti 파일의 과기구 조작이 치근단공 변위에 미치는 영향)

  • Yang, Hyun;Yang, In-Seok;Hwang, Yun-Chann;Hwang, In-Man;Yoon, Suk-Ja;Kim, Won-Jae;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.87-94
    • /
    • 2007
  • This study was done to evaluate transportation of the apical foramen after 0.5 mm overinstrumentation by ProFile, ProTaper and $K^3$ in simulated resin root canal. Sixty simulated resin root canal with a curvature of J and S-shape were divided into two groups. Each group consisted of three subgroups with 10 blocks according to the instruments used: $ProFile^{(R)},\;ProTaper^{TM},\;and\;K^{3TM}$. Simulated resin root canal was prepared by ProFile, ProTaper and $K^3$ with 300 rpm by the crown-down preparation technique. Pre- and post-instrumentation apical foramen images were overlapped and recorded with Image-analyzing microscope 100X (Camcope, Sometech Inc, Korea). The amounts of difference in width and dimension on overlapped images were measured after reference points were determined by Image Analysis program ($Image-Pro^{(R)}$ Express, Media Cybernetic, USA). Data were analyzed using Kruskal-Wallis and Mann-Whitney U-test. The results suggest that ProFile showed significantly less canal transportation and maintained original apical foramen shape better than $K^3$ and ProTaper.

The effects of various exposure times in the detectability on the tips of the endodontic files in Digora$\textregistered$ (Digora$\textregistered$에서 노출시간의 변화가 근관치료용 file의 첨부식별에 미치는 영향)

  • Ko Jee-Young;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.1
    • /
    • pp.55-71
    • /
    • 1997
  • Digora/sup (R)/ an intraoral digital radiography system utilizing image plate (IP) - has a dynamic range of exposure time which allows it to decrease the patient's exposure time and to increase diagnostic ability through image processing, transmission and storage. The purpose of this study was to evaluate the Digora/sup (R)/ system by assessing the effects of various exposure times on the detectability on the tip of the endodontic file. Examining the root canals of 45 extracted sound premolars, K -files No. 10, 15, and 20 were placed at slightly varying distances from the apex. The teeth were glued onto resin-plaster blocks. Five exposure times varying between 0.01 seconds and 0.25 seconds were used. Four observers were asked to measure the distance between the tip of the file and a reduction of crown portion, and obtained mean errors (subtracting true file length from the measured file length), comparing Digora/sup (R)/ monitors with E-plus films, which were both obtained under the same geometrical positions. The results were as follows : 1. Comparing E-plus film with Digora/sup (R)/ at 0.01 seconds, the mean errors in E-plus film showed -4.453 nun, -4.497 nun, and -3.857 nun, while the mean errors in Digora/sup (R)/ showed 0.065 nun, 0.607 nun, and 0.719 mm according to the file groups. Therefore there was a significant difference between E-plus film and Digora/sup (R)/(p<0.05). 2. By comparison of mean errors according to the various exposure times in the Digora/sup (R)/ system, the mean error at 0.01 seconds was significantly lower than that at 0.12 and 0.25 seconds in the No. 10 file group(p<0.05). And the standard deviation was the highest at 0.01 seconds. 3. Comparing E-plus film at 0.25 seconds with the Digora/sup (R)/ system, the mean errors showed a significant difference between E-plus film at 0.25 seconds and the Digora/sup (R)/ system at 0.25 seconds in No. 10 and 20 file groups(p<0.05). 4. Comparing E -plus film at 0.25 seconds with other exposure times, the mean errors showed a significant difference between E-plus film at 0.25 seconds and E-plus film at 0 .. 01 and 0.03 seconds in 10 file group(p<0.05). In the No. 15 and 20 file groups, there was a significant difference between E-plus film at 0.25 seconds and E-plus film at 0.01 seconds(p<0.05). In conclusion, Digora/sup (R)/ was better than E-plus film in detectability on the tip of the file at the exposure time of 0.01 seconds in all file groups. And we concluded that Digora/sup (R)/ can shorten exposure times up to 4% of 0.25 seconds (0.01 sec), which is adequate exposure time for premolar in E-plus film using No. 15 and 20 files.

  • PDF

A User-Level File System for Streaming Media Caching (스트리밍 미디어 캐슁을 위한 사용자 수준 화일 시스템)

  • Oh, Jae-Hak;Cha, Ho-Jeong
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.29 no.8
    • /
    • pp.472-483
    • /
    • 2002
  • This paper presents the design and implementation of a cache file system, umcFS, which is specifically designed to provide an efficient caching and transmission of streaming media. The proposed file system is based on the concept of file disk and implemented as an application level on top of a general-purpose file system. The file disk favors the continuity of cached media and provides an efficient I/O mechanism for cache server. umcFS statically allocates control blocks as well as media cache blocks. These blocks are referenced by the single-level indirect management structure. As the file system is designed as an application level, it is easy to develop and port to other systems. The performance of the implemented system shows that umcFS performs about 13% better than the native file system in randomly accessing the cache blocks of 1024KB.