• Title/Summary/Keyword: K-file

Search Result 1,997, Processing Time 0.022 seconds

IFCXML Based Automatic Data Input Approach for Building Energy Performance Analysis

  • Kim, Karam;Yu, Jungho
    • Journal of Construction Engineering and Project Management
    • /
    • v.3 no.1
    • /
    • pp.14-21
    • /
    • 2013
  • To analyze building energy consumption, the building description for building energy performance analysis (BEPA) is required. The required data input for subject building is a basic step in the BEPA process. Since building information modeling (BIM) is applied in the construction industry, the required data for BEPA can be gathered from a single international standard file format like IFCXML. However, in most BEPA processes, since the required data cannot be fully used from the IFCXML file, a building description for BEPA must be created again. This paper proposes IFCXML-based automatic data input approach for BEA. After the required data for BEPA has been defined, automatic data input for BEPA is developed by a prototype system. To evaluate the proposed system, a common BIM file from the BuildingSMART website is applied as a sample model. This system can increase the efficiency and reliability of the BEPA process, since the data input is automatically and efficiently improved by directly using the IFCXML file..

A Study on the Future Storage System as brain coordinator

  • Yi, Cheon-Hee;Yi, Jae-Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.8 no.1
    • /
    • pp.39-42
    • /
    • 2009
  • In this paper an attempt for realizing a storage system which works as a part of human brain has been discussed. The system is expected to be able to coordinate with human brain. And current storage may have inherent problem due to an intrinsic attribute of storage, exclusiveness. Directory structure in it must be a source of confusion, if it used out side of the range of limitation. Adapting multidimensional annotation of file name extension and directory-less file system, a new storage system able to associate and coordinate with human brain may be available near future. This paper showed that the limitation of current storage system clearly exists, because of human brain limitation to memorize directory name.

  • PDF

Classification of Non-Signature Multimedia Data Fragment File Types With Byte Averaging Gray-Scale (바이트 평균의 Gray-Scale화를 통한 Signature가 존재하지 않는 멀티미디어 데이터 조각 파일 타입 분류 연구)

  • Yoon, Hyun-ho;Kim, Jae-heon;Cho, Hyun-soo;Won, Jong-eun;Kim, Gyeon-woo;Cho, Jae-hyeon
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.30 no.2
    • /
    • pp.189-196
    • /
    • 2020
  • In general, fragmented files without signatures and file meta-information are difficult to recover. Multimedia files, in particular, are highly fragmented and have high entropy, making it almost impossible to recover with signature-based carving at present. To solve this problem, research on fragmented files is underway, but research on multimedia files is lacking. This paper is a study that classifies the types of fragmented multimedia files without signature and file meta-information. Extracts the characteristic values of each file type through the frequency differences of specific byte values according to the file type, and presents a method of designing the corresponding Gray-Scale table and classifying the file types of a total of four multimedia types, JPG, PNG, H.264 and WAV, using the CNN (Convolutional Natural Networks) model. It is expected that this paper will promote the study of classification of fragmented file types without signature and file meta-information, thereby increasing the possibility of recovery of various files.

Comparison of shaping ability between various hybrid instrumentation methods with ProTaper (ProTaper를 사용한 다양한 hybrid instrumentation methods의 근관성형 효율 비교)

  • Hong, Eun-Sook;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.1
    • /
    • pp.11-19
    • /
    • 2006
  • The purpose of this study was to compare and evaluate the shaping abilities of various hybrid instrumentation method using constant tapered file systems with $ProTaper\^{(R)}$ S1 and the difference between experts and inexperienced clinicians in use of NiTi file. Three hybrid methods used in this study were composed of $ProTaper\^{(R)}\;S1\;and\;K-Flexofile\^{(R)}\;(group S),\;ProTaper\^{(R)}\;S1\;and\;HeroShaper\^{(R)}\;(group\;H),\;and\;ProTaper\^{(R)}\;S1\;and\;ProFile\^{(R)}\;(group\;P)$respectively. The $ProTaper\^{(R)}$-alone method (group C) was introduced as a control group. After canal preparation, the lapse of time was recorded. The images of pre- and post-operative canal were scanned and superimposed. Amounts of instrumented canal widths and centering ratio were measured at apical 1, 2 and 3 mm levels and statistical analysis was performed In this study. both of the group C and S took more time to prepare canals than other groups, Inexperienced operators required more time for the entire preparation with the groups C and H than the experienced (p<0.05). And the centering ratio of group P were preferable to $ProTaper\^{(R)}$-alone method or the hybrid technique using stainless steel files. As such, within experienced operators, group H also showed better results in addition to the group P. Under these condition, the hybrid methods of each the $ProFile^{(R)}$ system and $HeroShaper^{(R)}$ with ProTaper are recommendable comparative to $ProTaper\^{(R)}$-alone method. According to the results, the hybrid instrumentation method is a more appropriate method of canal preparation than single file system for narrow or curved canals.

STRESS DISTRIBUTION OF THREE NITI ROTARY FILES UNDER BENDING AND TORSIONAL CONDITIONS USING 3-DIMENSIONAL FINITE ELEMENT ANALYSIS (세가지 니켈 티타늄 파일의 휨과 비틀림 조건에서의 응력 분포에 관한 3차원 유한요소 연구)

  • Kim, Tae-Oh;Lee, Chan-Joo;Kim, Byung-Min;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.323-331
    • /
    • 2008
  • Flexibility and fracture properties determine the performance of NiTi rotary instruments. The purpose of this study was to evaluate how geometrical differences between three NiTi instruments affect the deformation and stress distributions under bending and torsional conditions using finite element analysis. Three NiTi files (ProFile .06 / #30, F3 of ProTaper and ProTaper Universal) were scanned using a Micro-CT. The obtained structural geometries were meshed with linear, eight-noded hexahedral elements. The mechanical behavior (deformation and von Mises equivalent stress) of the three endodontic instruments were analyzed under four bending and rotational conditions using ABAQUS finite element analysis software. The nonlinear mechanical behavior of the NiTi was taken into account. The U-shaped cross sectional geometry of ProFile showed the highest flexibility of the three file models. The ProTaper, which has a convex triangular cross-section, was the most stiff file model. For the same deflection, the ProTaper required more force to reach the same deflection as the other models, and needed more torque than other models for the same amount of rotation. The highest von Mises stress value was found at the groove area in the cross-section of the ProTaper Universal. Under torsion, all files showed highest stresses at their groove area. The ProFile showed highest von Mises stress value under the same torsional moment while the ProTaper Universal showed the highest value under same rotational angle.

Implementation of a File Security Module in the Windows Operating System (윈도우 운영체제의 파일 보안 모듈 개발)

  • Lee, Seong-Heon;Jang, Seung-Ju
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.660-663
    • /
    • 2011
  • The file security function, which this paper suggests, restricts the access of an unauthorized users by using password algorithm and saving file. Saved files that are encrypted are read by decrypting them with decryption algorithm. These features are user interface to design the program for user friendly. The security function implements both file encryption and decryption programs and tests whether the experiment works or not. In addition, when a decryption is progressed and the settings of between decryption and encryption are different each other, the security function also checks the possibility of decryption. We can enhance the security on important files stored in Windows servers or personal computers by developing this program.

  • PDF

Authoring Tool of Musical Slide Show MAF Contents

  • Sabirin Muhammad Syah Houari;Kim Mun-Churl
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.289-295
    • /
    • 2006
  • The Musical Slide Show MAF, which currently being standardized by MPEG, conveys the concept of combining several established standard technologies in a single file format. It defines the format of packing up MP3 audio data, along with MPEG-7 Simple Metadata Profile and MPEG-21 Digital Item Declaration metadata; with JPEC images and optional text, and synchronizes them all together to create a slideshow of JPEC image data associated to MP3 audio data during the audio playback. The implementation of Musical Slide Show MAF can be a music karaoke file where users can sing along while listening to the music, view the JPEG slideshow and reading the lyrics; or a story-telling file where users can listen to the narrated story by looking at the related illustration slideshow of the story In this paper we present the tool to producing the Musical Slide Show MAF contents. Regardless the knowledge of user on the MAF file format, the authoring tool simplify the manner of packaging several multimedia contents into single file.

  • PDF

A Study of Communications Security by Using Key Generation and File Encryption (파일 암호화와 키 생성을 이용한 통신보안 연구)

  • Lee, Jae-Hyun;Park, Dea-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.316-319
    • /
    • 2010
  • File security is typically protected by encryption methods. The development of a network environment, such as the Internet according to the sharing of information between systems become commonplace, while providing convenience to users, individuals or organizations that facilitate access to sensitive information caused by hacking the system to attack the rapidly growing is a trend. This paper is the latest generation file system caused by the hacking attacks on the Sniffing for users using file encryption and key generation, Packet Sniffing Tool IP and data through the analysis are discussed. Through this study, the importance of protecting personal information by imprinting Proactive in the hacking incident, and what users will contribute to increase the level of security awareness.

  • PDF

THE EFFECT OF GUTTA-PERCHA REMOVAL USING NICKEL-TITANIUM ROTARY INSTRUMENTS (엔진 구동형 니켈 티타늄 파일을 이용한 거터퍼쳐의 제거 효과)

  • Jeon, Jeong-Hun;Min, Jeong-Beom;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.3
    • /
    • pp.212-218
    • /
    • 2004
  • The purpose of this study was to quantify the amount of remaining gutta-percha/sealer on the walls of root canals when three types of nickel-titanium rotary instruments (Profile. ProTaper and $K^3$) and a hand instrument(Hedstrom file) used to remove these materials. The results of this study were as follows: 1. In the total time for gutta-percha removal. Profile group was the fastest and followed by $K^3$, Protaper, Hedstrom file group. 2. In case of the evaluation of the volume of remained gutta-percha from radiograph. $K^3$ group got the highest score and followed by Protaper. Hedstrom file. Profile group in the apical 1/3. 3. In case of the evaluation of the volume of gutta-percha remained from stereomicroscope, $K^3$ group got the highest score and followed by Protaper. Hedstrom file. Profile group in the apical 1/3. These results showed that instrumentation using nickel-titanium rotary instrument groups was faster than that using hand instrument group. The effect of gutta-percha removal using Profile group was better than that using Protaper and $K^3$ group in the nickel-titanium rotary instrument groups.

Effect of internal stress on cyclic fatigue failure in K3 (K3에 축적된 내부 응력이 피로 파절에 미치는 영향)

  • Kim, Jun-Young;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.2
    • /
    • pp.74-78
    • /
    • 2012
  • Objectives: This study aimed to evaluate the relationship between the cyclic fatigue of a K3 file and internal stress intentionally induced until the activation of the autostop function of the torque-controlled motor. Materials and Methods: K3 (Sybron Endo) .04 and .06 taper, size 25, 30, 35, 40 and 45 were used in this study. To give the internal stress, the K3 files were put into the .02 taper Endo-Training-Bloc (Dentsply Maillefer) until the activation of the auto-stop function of the torque-controlled motor. The rotation speed was 300 rpm and torque value was 1.0 $N{\cdot}cm$. K3 were grouped by the number of induced internal stress and randomly distributed to 4 experimental groups (n = 10, Stress 0 [control], Stress 1, Stress 2 and Stress 3). For measuring the cyclic fatigue failure, the K3 files were worked against a sloped glass block and time for file separation was recorded. Data was statistically analyzed Statistical analyses were performed using two-way ANOVA and Duncan post-hoc test at p < 0.05 level. Results: Except .04 taper size 30 in Stress 1 group, there were statistically significant differences in time for file separation between control and all experimental groups. K3 with .04 taper showed higher cyclic fatigue resistance than those of .06 taper. Conclusion: In the limitation of this study, the cyclic fatigue of the K3 file was influenced by the accumulated internal stress from use until the auto-stop function was activated by the torque-controlled motor. Therefore, clinicians should avoid the reuse of the K3 file that has undergone auto-stops.