• Title/Summary/Keyword: K-GIC

Search Result 77, Processing Time 0.032 seconds

COMPARISON OF MARGINAL LEAKAGE OF WEDGE-SHAPED CLASS V CAVITY ACCORDING TO RESTORATIVE MATERIALS (쐐기 형태의 5급와동에서 수복재료에 따른 변연 미세누출의 비교)

  • Jang, Hyun-Joo;Lee, Hee-Joo;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.56-62
    • /
    • 2000
  • The purpose of this study was to assess the effects of restorative materials on the marginal leakage of wedge-shaped class V cavity. The study was performed in vitro in 25 defect-free permanent, extracted teeth. Wedge-shaped class V cavities were prepared and then the teeth were randomly selected and restored according to the following. Group A : restoration with Tetric Ceram(composite resin) Group B : restoration with Tetric flow(flowable resin) Group C : restoration with Compoglass after acid etching(compomer) Group D : restoration with Compoglass(compomer) Group E : restoration with Fuji II LC improved(resin-modified GIC) After thermocycling, the specimens were immersed in 5% basic fuchsin solution for 6 hours and sectioned longitudinally through the center of the restoration. The degree of marginal leakage was measured as the extent of dye penetration under the stereomicroscope. The data were analysed using one-way ANOVA. When significant differences found, multiple comparisons were made using Duncan's Multiple Range Test. The results were as follows: 1. The occlusal margins of all groups except for Fuji II LC improved showed lesser leakage than gingival margins and there was statistically significant difference(p<0.05). 2. At the occlusal margins, group A, B showed same marginal leakage scores, and others were decreased as group C, D, E in that order. There were statistically significant difference between group A, Band group D, E, group C and group E(p<0.05). 3. At the gingival margins, group B, C showed same marginal leakage scores, and others were decreased as group A, D, E in that order. But there was statistically significant difference between group B, C and group E(p<0.05). 4. In the Compoglass restoration, acid-etching technique was beneficial for marginal sealing ability at all of margins. But there was no statistically significant difference (p>0.05). In the restorations for wedge-shaped class V cavities, resin restoration with acid etching technique is recommended.

  • PDF

Sedimentological Study of the Nakdong Formation to analyse the Forming and Evolving Tectonics of the Cretaceous Gyeongsang Basin, I: Depositional Setting, Source, and Paleocurrent Analyses of the Nakdong Formation in the Southwestern Gyeongsang Basin (백악기 경상분지의 생성 및 진화에 관여한 지구조운동의 분석과 최하부 낙동층에 대한 퇴적학적 연구 I: 경상분지 서남단 낙동층의 퇴적환경과 기원암, 고수류 분석)

  • Cheong, Dae-Kyo;Kim, Yong-In
    • Economic and Environmental Geology
    • /
    • v.29 no.5
    • /
    • pp.639-660
    • /
    • 1996
  • The lowest formation of the Cretaceous Gyeongsang Supergroup, the Nakdong Formation, unconformably overlies the gneiss complex basement in Hadong, Gyeongsangnam-do and Gwangyang, Chullanam-do. The Nakdong Formation of the study area is 500-600 m thick and occurs as a belt shape. Based upon lithology, sedimentary structure, and bedding geometry the formation consists of three conglomerate facies (Gd, Gn, Gic), five sandstone facies (Sh-n, Sh-i, Sp, Sr, Sm), and four mudstone facies (Mf, Mfn, Mc, Mv). Sandstone facies are the most prominent in the study area. The twelve facies can be grouped into five facies associations. The depositional settings are elucidated from analyses of 12 facies and five facies associations of the formation. The lower part of the Nakdong Formation was deposited in alluvial plain, and the middle and upper parts were in a riverine system. The lithologies of the Nakdong Formation of the Gyeongsang Basin have been considered to consist of generally conglomerates and pebbly sandstones that were accumulated in alluvial fans. But the common lithology of the study area is sandstone which was formed in lower part of alluvial fan or fluvial setting. It is supposed that the coarser sedimentary sequence distributed west to the study area should be eroded out after deposition and early uplift, and the finer sandstone sequence in the east remains behind. The mineral composition of sandstones and the clast composition of conglomerates indicate that the Nakdong Formation was derived mainly from the metamorphic source rocks. Some reworked intraclasts were also supplied from the intrabasinal sedimentary layers. Paleocurrent data collected from cross-beddings, ripple marks, asymmetric sand dune suggest that most sediments were transported from north to south during the Nakdong Formation time.

  • PDF

Verification on the Calculated Geoelectric Field on Power Grid during Geomagnetic Disturbances (지자기 교란으로 인한 전력망 유도전기장 예상값 검증)

  • Park, Sung Won;Yoo, Chung-Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.1
    • /
    • pp.94-100
    • /
    • 2015
  • Coronal mass ejection (CME) released due to solar flare explosion cause geomagnetic disturbance. The induced current by massive geomagnetic disturbance can cause damage to the transformer. The calculated geoelectric field is a major parameter of the geomagnetically induced current (GIC). The method applying a Fourier transform has a high accuracy but it needs all data measured for 24 hours. And the other method applying a integral equation can calculate in real time but it requires to check an accuracy. To reduce the gap between the calculated results of two methods, it adjusts the integration section. As a result, the correlation between two calculated geoelectric fields is high, and the event time and direction of the calculated current is the same as that of the measured current, and it's accuracy rate is above 92 percent.

Evaluation of internal adaptation of dental adhesive restorations using micro-CT

  • Kwon, Oh-Hyun;Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.1
    • /
    • pp.41-49
    • /
    • 2012
  • Objectives: The internal adaptation of composite restorations with or without resin modified glass ionomer cement (RMGIC) was analyzed non-destructively using Microcomputed tomography (micro-CT). Materials and Methods: Thirty intact human teeth were used. The specimens were divided into 3 groups. In the control group, the cavities were etched with 10% phosphoric acid for 15 sec. Composite resin was filled into the cavity without adhesive. In group 1, light cured glass ionomer cement (GIC, Fuji II LC, GC) was applied as a base. The cavities were then etched, bonded, light cured and filled with composites. In group 2, the cavities were then etched, bonded, light cured and filled with composites without base application. They were immersed in a 25% silver nitrate solution. Micro-CT was performed before and after mechanical loading. One-way ANOVA with Duncan analysis was used to compare the internal adaptation between the groups before or after loading. A paired t-test was used to compare internal adaptation before and after mechanical loading. All statistical inferences were made within the 95% confidence interval. Results: The silver nitrate solution successfully penetrated into the dentinal tubules from the pulp spaces, and infiltrated into the gap between restoration and pulpal floor. Group 2 showed a lower adaptation than the control group and group 1 (p < 0.05). There was no significant difference between the control group and group 1. For all groups, there was a significant difference between before and after mechanical loading (p < 0.05). Conclusions: The internal adaptation before and after loading was better when composites were bonded to tooth using adhesive than composites based with RMGIC.

Effects of a bleaching agent on properties of commercial glass-ionomer cements

  • de Camargo, Fernanda Lucia Lago;Lancellotti, Ailla Carla;de Lima, Adriano Fonseca;Martins, Vinicius Rangel Geraldo;de Souza Goncalves, Luciano
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.3
    • /
    • pp.32.1-32.11
    • /
    • 2018
  • Objectives: This study evaluated the effects of a bleaching agent on the composition, mechanical properties, and surface topography of 6 conventional glass-ionomer cements (GICs) and one resin-modified GIC. Materials and Methods: For 3 days, the specimens were subjected to three 20-minute applications of a 37% $H_2O_2$-based bleaching agent and evaluated for water uptake (WTK), weight loss (WL), compressive strength (CS), and Knoop hardness number (KHN). Changes in surface topography and chemical element distribution were also analyzed by energy-dispersive X-ray spectroscopy and scanning electron microscopy. For statistical evaluation, the Kruskal-Wallis and Wilcoxon paired tests (${\alpha}=0.05$) were used to evaluate WTK and WL. CS specimens were subjected to 2-way analysis of variance (ANOVA) and the Tukey post hoc test (${\alpha}=0.05$), and KH was evaluated by one-way ANOVA, the Holm-Sidak post hoc test (${\alpha}=0.05$), and the t-test for independent samples (${\alpha}=0.05$). Results: The bleaching agent increased the WTK of Maxxion R, but did not affect the WL of any GICs. It had various effects on the CS, KHN, surface topography, and the chemical element distribution of the GICs. Conclusions: The bleaching agent with 37% $H_2O_2$ affected the mechanical and surface properties of GICs. The extent of the changes seemed to be dependent on exposure time and cement composition.

Effects of Flexural Modulus and Fiber Bridging on the Interlaminar Fracture Energy of Multidirectional Composite Laminates under High Rate Loading (고속하중을 받는 다방향복합적층판의 층간파괴에너지에 미치는 굽힘탄성계수와 섬유가교의 효과)

  • ;A.J.Kinloch
    • Composites Research
    • /
    • v.12 no.5
    • /
    • pp.40-53
    • /
    • 1999
  • The interlaminar facture behavior of multidirectional carbon-fiber/epoxy composite laminates under low and high rates of test, up to rate of about 11.4m/s has been investigated using the double cantilever beam specimens. The mode I loasing with rates above 1.0m/s had considerable dynamic effects on the load-time curves and thus revealed higher values of the average crack velocity than thet expected from a simple proportional relationship with the test rate. The modified beam analysis utilizing only the opening displacement and crack length exhibited an effective means for evaluating the dynamic fracture energy $G_{IC}$. Flexural modulus increased gradually with an increase of the test rate, which was utilized in the evaluation of $G_{IC}$. Values of $G_{IC}$ at the crack initiation and arrest were scarcely changed with increasing test rate up to 1.0m/s. However the maximum $G_{IC}$ was much enlarged at 11.4m/s due to the large amount of fiber bridging the crack tip. The larger the initial crack length, the smaller the maximum $G_{IC}$ at high rate.

  • PDF

Cure Kinetics and Mechanical Interfacial Characteristics of Zeolite/DGEBA Composites (제올라이트/DGEBA 복합재료의 경화 동력학과 기계적 계면특성)

  • Soo-Jin Park;Young-Mi Kim;Jae-Sup Shin
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.5
    • /
    • pp.472-478
    • /
    • 2003
  • In this work, the zeolite/diglycidylether of bisphenol A(DGEBA) systems were investigated in terms of the cure kinetics and mechanical interfacial properties of the composites. The 4, 4-diamino diphenyl methane(DDM) was used as a curing agent for epoxy. Two types of zeolite(PZ) were prepared with 15 and 35 wt% KOH treatments(15-BZ and 35-BZ, respectively) for 24 h, and their surface characteristics were studied by X-ray photoelectron spectroscopy (XPS) and X-ray diffraction(XRD). Cure kinetics of the composites were examined in the context of differential scanning calorimetry(DSC), and mechanical interfacial properties were investigated in critical stress intensity factor($K_{IC}$) and critical strain energy release rate($G_{IC}$). In the results of XPS and XRD, sodium ion(Na) of zeolite was exchanged for potassium ion(K), resulting from the treatment of KOH. Also, $Si_{2p}/Al{2p}$ composition ratios of the treated zeolite were increased, which could be attributed to the weakening of Al-O bond in framework. Cure activation energy($E_a$) of 15-BZ composites was decreased, whereas KIC and $G_{IC}$ were increased, compared with those of the pure zeolite/DGEBA composites. It was probably accounted that the acidity of zeolite was increased by surface treatments and the cure reaction between zeolite and epoxy was influenced on the increased acidity of zeolite.

STRESS ANALYSIS OF MAXILLARY PREMOLARS WITH COMPOSITE RESIN RESTORATION OF NOTCH-SHAPED CLASSⅤCAVITY AND ACCESS CAVITY ; THREE-DIMENSIONAL FINITE ELEMENT STUDY (쐐기형 5급 와동과 근관와동을 복합레진으로 수복한 상악 소구치에 대한 응력 분석: 3차원 유한요소법적 연구)

  • Lee, Seon-Hwa;Kim, Hyeon-Cheol;Hur, Bock;Kim, Kwang-Hoon;Son, Kwon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.6
    • /
    • pp.570-579
    • /
    • 2008
  • The purpose of this study was to investigate the distribution of tensile stress of canal obturated maxillary second premolar with access cavity and notch-shaped class V cavity restored with composite resin using a 3D finite element analysis. The tested groups were classified as 8 situations by only access cavity or access cavity with notch-shaped class V cavity (S or N), loading condition (L1 or L2), and with or without glass ionomer cement base (R1 or R2). A static load of 500 N was applied at buccal and palatal cusps. Notch-shaped cavity and access cavity were filled microhybrid composite resin (Z100) with or without GIC base (Fuji II LC). The tensile stresses presented in the buccal cervical area, palatal cervical area and occlusal surface were analyzed using ANSYS. Tensile stress distributions were similar regardless of base. When the load was applied on the buccal cusp, excessive high tensile stress was concentrated around the loading point and along the central groove of occlusal surface. The tensile stress values of the tooth with class Ⅴ cavity were slightly higher than that of the tooth without class V cavity. When the load was applied the palatal cusp, excessive high tensile stress was concentrated around the loading point and along the central groove of occlusal surface. The tensile stress values of the tooth without class V cavity were slightly higher than that of the tooth with class V cavity.

The relation of structural transition, thermal and electrical stability deintercalation of Li- CICs(II) : For Li-EaGDICs and Li-EGDICs (Li-CICs의 Deintercalation에 따른 구조변이와 열적, 전기적 안정성과의 관계(II) : Li-EaGDICs와 Li-EGDICs에 관하여)

  • Oh, Won-Chun;Park, Chung-Oh;Back, Dae-Jin;Ko, Young-Shin
    • Analytical Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.43-51
    • /
    • 1996
  • We have discussed on the deintercalation process of Li-EaGICs and Li-EGICs synthesized under pressure and temperature by spontaneous oxidation reaction of those compounds based on the results of X-ray diffraction, thermal analysis and electrical specific resistivity analysis. According to the results of the X-ray analysis for the intercalation process, we have found that the stage 1 for Li-EaGICs and Li-EGICs were not completly formed, but their lower stages were formed mainly. And from this results of the deintercalation process, we have found that the deintercalation process did not occur any more after 4 weeks, and the Li-EGDICs have more residual lithium metals than LiEaGDICs between the graphite interlayers. According to the thermal decomposition analysis, Li-two compounds had included very hard exothermic reaction. And we have found that these compounds did not occrurred deintercalation reaction above $400^{\circ}C$. According to the results of the electrical specific resistivity measurements, Li-EGDICs have relatively lower electrical specific resistivity than Li-EaGDICs, and Li-EaGDICs showed a formation of the ideal curve. From these results, we can suggest that Li-EaGDICs have a better properties as an anode material secondary than Li-EGICs.

  • PDF

CHARACTERISTICS OF FLUORIDE RELEASING RESTORATIVE MATERIALS AFTER TOOTHBRUSH-DENTIFRICE ABRASION (잇솔질 마모 처리한 불소방출성 수복재의 특성)

  • Park, Jong-Ha;Baik, Byeong-Ju;Yang, Yeon-Mi;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.705-713
    • /
    • 2004
  • The objectives of this study were to evaluate the fluoride release and the change of surface roughness of fluoride releasing restorative materials after toothbrush-dentifrice abrasion. Seven commercially available fluoride releasing restorative materials (Fuji II LC Improved: FL, Compoglass F: CG, Dyract AP: DR, F2000: FT, Ariston: AT, Tetric: TR, and Gradia: GD) were selected as experimental materials. The results obtained were summarized as follows: 1. The AT, FL, and CF groups produce an initially large burst of fluoride release and comparatively low but continuous release of fluoride. But other groups produce no initial burst of fluoride and levels of release remain relatively constant. 2. The rate of fluoride release remains steady state after 40 days. The results of Tukey's test (P<.05), the fluoride release showed the order of decreasing rank as follows: AT > FL > compomers > TC and GD. 3. The surface roughness indicated that the highest value was observed in the FT group and the lowest value was observed in the CF group. The surface roughness of Tukey's test showed the significant differences between groups of FT, AT and FL and groups of CF, DR, GD and TC (P<0.05).

  • PDF