• Title/Summary/Keyword: K-7 Mode

Search Result 1,819, Processing Time 0.032 seconds

SLIDING MODE MOULD LEVEL CONTROL IN CONTINUOUS CASTING PROCESS

  • Kueon, Yeong-Seob
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.4
    • /
    • pp.50-55
    • /
    • 1998
  • Mould level control system for continuous casting process involves stick-slip friction in the sliding gate , time-delay, non-linearity, and certain uncertainties such as friction force variations between molten steel and the inner wall of mould. In this paper, sliding mode control technique was used to solve these complex control problem. The controller is then designed and implemented onto the continuous casting process. Testing result shows that sliding mode controller can decrease the fluctuating magnitude of the mould level and is superior to the existing PID controller.

Compact Triple-Mode Resonator and Triple-Mode Filter Design (소형의 삼중 모드 공진기와 삼중 모드 필터 설계)

  • Lee, Ja-Hyeon;Lim, Yeong-Seog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.4
    • /
    • pp.447-452
    • /
    • 2011
  • In this paper, we present a compact triple-mode resonator. The resonator itself can provide three transmission poles and one transmission zero. The resonance condition of each mode is analyzed theoretically, and the transmission zero is generated by open stub. Using this proposed resonator, a compact three pole bandpass filter for 2.4 GHz WLAN application with one transmission zero is designed and fabricated. The fabricated triple-mode filter shows 3 dB bandwidth of 15.8 % with the center frequency 2.4 GHz and less then 1.17 dB in 2.4~2.5 GHz passband. The size of fabricated triple-mode filter including the feed lines is 15.9 mm${\times}$9.7 mm and very compact compared with previous reported triple-mode filter.

Mode Control Design of Dual Buck Converter Using Variable Frequency to Voltage Converter (주파수 전압 변환을 이용한 듀얼 모드 벅 변환기 모드 제어 설계)

  • Lee, Tae-Heon;Kim, Jong-Gu;So, Jin-Woo;Yoon, Kwang-Sub
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.4
    • /
    • pp.864-870
    • /
    • 2017
  • This paper describes a Dual Buck Converter with mode control using variable Frequency to Voltage for portable devices requiring wide load current. The inherent problems of PLL compensation and efficiency degradation in light load current that the conventional hysteretic buck converter has faced have been resolved by using the proposed Dual buck converter which include improved PFM Mode not to require compensation. The proposed mode controller can also improve the difficulty of detecting the load change of the mode controller, which is the main circuit of the conventional dual mode buck converter, and the slow mode switching speed. the proposed mode controller has mode switching time of at least 1.5us. The proposed DC-DC buck converter was implemented by using $0.18{\mu}m$ CMOS process and die size was $1.38mm{\times}1.37mm$. The post simulation results with inductor and capacitor including parasitic elements showed that the proposed circuit received the input of 2.7~3.3V and generated output of 1.2V with the output ripple voltage had the PFM mode of 65mV and 16mV at the fixed switching frequency of 2MHz in hysteretic mode under load currents of 1~500mA. The maximum efficiency of the proposed dual-mode buck converter is 95% at 80mA and is more than 85% efficient under load currents of 1~500mA.

Monitoring of Airborne Fine Particle using SMPS in Ansan Area (SMPS(Scanning Mobility Particle Sizer)를 이용한 안산지역 대기중 초미세입자(30\~500nm) 분포연구)

  • Kim Yong-min;Ahn Kang-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.3
    • /
    • pp.295-301
    • /
    • 2005
  • The fine particles in the range of $30\~500nm$ are monitored at Hanyang University campus in Ansan using house made DMA (differential mobility analyzer) and commercial CPC (condensation particle counter, TSI inc.) in SMPS mode. The monitoring period is March 16th 2004 through May 7th, 2004. During the monitoring period, Aitken nuclei mode $(30\~100nm)$ particle concentration has a tendency of increase in the morning and evening hours. However, the accumulation mode $(100\~500nm)$ particle concentration stays rather stable than that of Aitken mode.

Operation Modes Can Affect the Activity of Immobilized Enzyme onto Silk Fibroin Nanofibrous Membrane

  • Oh, Hanjin;Lee, Ki Hoon
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.27 no.2
    • /
    • pp.322-325
    • /
    • 2013
  • In the present study, we report that the selection of operation mode is important to take the full advantage of nanofibrous membrane in enzyme immobilization. Silk fibroin nanofibrous membrane has been prepared by electrospinning, and a-chymotrypsin was immobilized as a model enzyme. When the immobilized enzyme was operated in the membrane reactor mode, the Michaelis constant, Km, was lower and the Vmax was higher compared to the batch reactor mode. No concentration gradient was observed in the membrane reactor mode and the immobilized enzyme was stable even after 7 times of re-use. Our results suggests that the enzyme immobilized nanofibrous membrane should be operated in the membrane reactor mode rather than in the bath reactor mode.

A System Operating Algorithm for the Effective Operation of a Multi-type Air-conditioning System (멀티형공조시스템의 효과적인 운전을 위한 시스템운전알고리즘)

  • Han Do-Young;Park Kwan-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.7
    • /
    • pp.587-595
    • /
    • 2006
  • A system operating algorithm was developed for the effective operation of a multi-type air-conditioning system. The system operating algorithm includes control algorithms for a safety mode, an initial operating mode, a stabilization mode, a fault diagnosis mode, an efficiency mode, and a tracking mode. Various tests were performed to show the effectiveness of these algorithms. Tests showed good results for the operation of a multi-type air-conditioning system. Therefore, these algorithms developed for this study may be used for the effective control of a multi-type air-conditioning system.

Improved Modulation Techniques of Three-Phase H7 Inverter to Reduce Common Mode Voltage (커먼 모드 전압 저감을 위한 3상 H7 인버터의 개선된 변조 기법)

  • Lee, Seung-Hwan;Jung, Jun-Hyung;Hwang, Seon-Ik;Kim, Jang-Mok
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.73-74
    • /
    • 2017
  • 본 논문에서는 H7 인버터와 DPWM 기반의 개선된 변조 기법을 이용한 2-레벨 인버터의 커먼 모드(Common Mode) 전압 저감 방법을 제안한다. 기존의 H7 인버터를 이용한 커먼 모드 전압 저감 방법은 스위칭 신호 구현을 위해 추가적인 논리회로가 필요하고, 일부 영역에서 커먼 모드 전압 저감이 이루어지지 않는 문제점이 있다. 제안하는 방법은 옵셋(Offset) 전압을 이용한 변조 방식을 사용하여 3상 인버터의 스위칭 신호를 생성하고, 3상의 지령 값을 이용하여 7번째 스위치의 스위칭 패턴을 결정한다. 이를 통해 추가적인 논리 회로 없이 하나의 캐리어만을 이용하여 모든 스위치의 스위칭 신호를 구현하며, 모든 영역에서 커먼 모드 전압 저감이 이루어지도록 하였다. 제안된 방법의 커먼 모드 전압 저감, 출력 상전류 왜곡 특성에 대한 성능을 시뮬레이션을 통해 검증하였다.

  • PDF

Comparison of Wound Healing in Porcine Skin with Continuous-Wave and Pulsed Mode $CO_2$ Laser Incisions (돼지에서 연속형 $CO_2$ 레이저와 펄스형 $CO_2$ 레이저를 이용한 피부절개시 창상치유 평가)

  • Lee, Jae-Yeon;Cho, Sung-Whan;Park, Chang-Sik;Kim, Myung-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.27 no.6
    • /
    • pp.647-651
    • /
    • 2010
  • The advantages of the $CO_2$ laser are offset by the delay in laser wound healing secondary to thermal damage. To minimize the undesirable thermal damage of the $CO_2$ laser, investigators have developed technical advances in the delivery system of the laser energy. This study compared tissue healing of the continuous and the pulsed modes $CO_2$ laser wounds in an animal surgery model. Five healthy Landrace and Yorkshire mixed breeds of both genders were used (45-51 kg, 4-6 months old, three males and two females). A full thickness wound of skin ($2{\times}2{\times}2cm^2$) was made over on the each pig's both sides of dorsal midline at 0, 7, 14, and 18 days. The wounds created at 18, 14, 7 and 0 days were named post-wounding day (PWD) 3, 7, 14 and 21, respectively. In each pig, one wound (left side) was treated pulsed $CO_2$ laser and the other wound (right side) was treated continuous wave $CO_2$ laser. Each wound was closed with two interrupted suture of 3-0 sutures. At 21 days after initial wounding, each wound was taken for histological evaluations. The degrees of reepithelialization were performed more prominently in the pulsed mode group than in the continuous mode group. The degrees of granulation were greater significantly in pulsed mode group than those in the continuous mode on PWD 3 (p < 0.05). The degrees of fibroblasts in the pulsed mode group were greater significantly in comparison to those in the continuous mode group on PWD 7, (p < 0.05). In conclusion, reepithelialization, granulation and fibroblasts in the pulsed mode group were greater markedly in comparison to those in the continuous mode group. It was considered that pulsed mode $CO_2$ laser was more suitable for the skin incision than the continuous mode $CO_2$ laser.

Step-Down Voltage Properties of Piezoelectric Transformer with Extensional Vibration Mode (Extensional 진동 모드를 이용한 압전 트랜스포머의 감압 특성)

  • Choi, Ji-Hyun;Bang, Kyu-Seok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.652-655
    • /
    • 2003
  • In this paper, step-down piezoelectric transformer is studied. The piezoelectric transformer, made of lead zirconate titanate solid solution ceramic, is operated by a fundamental contour-extensional vibration mode. The transformer of 14mm length, 14mm width and 4.5mm thickness was made up two shape(Type I and II). The resonant frequency (fr) is 144kHz and 128kHz at the load resistant of $7.5{\Omega}$ that is a similar to calculating matching impedance. The gain (G) obtained 0.19 and 0.08 at each resonant frequency, when applied input voltage is 25V. The temperature difference with the variation of load resistant was increased with increasing load resistant and was the lowest at $7.5{\Omega}$ near the matching of output impedance.

  • PDF

A Method of Intra Mode Coding for Joint Exploration Model (JEM) (차세대 비디오 부호화 실험모델(JEM)의 화면내 예측 모드 부호화 기법)

  • Park, Dohyeon;Lee, Jinho;Kang, Jung Won;Kim, Jae-Gon
    • Journal of Broadcast Engineering
    • /
    • v.23 no.4
    • /
    • pp.495-502
    • /
    • 2018
  • JVET (Joint Video Exploration Team) which explored evolving technologies of video coding with capabilities beyond HEVC (High Efficiency Video Coding), released a references software codec named the Joint Exploration Model (JEM) for performance verification of coding technologies. JEM has 67 intra prediction modes that extend the 35 modes of HEVC for intra prediction. Therefore, the enhancement of the coding performance is limited due to the overhead of prediction mode coding. In this paper, we analyze the probabilities of prediction modes selections, and then we propose a more efficient intra prediction mode coding based on the results of analyzed mode occurrence. In addition, we propose a context modeling for CABAC (Context-Adaptive Binary Arithmetic Coding) of the proposed mode coding. Experimental results show that the BD-rate gain is 0.02% on the AI (All Intra) coding structure compared to JEM 7.0. We need to optimize context modeling for additional coding performance enhancement.