• Title/Summary/Keyword: K-최근접법

Search Result 15, Processing Time 0.028 seconds

An Interpolation Method for a Barrel Distortion Using Nearest Pixels on a Corrected Image (방사왜곡을 고려한 보정 영상 위최근접 화소 이용 보간법)

  • Choi, Changwon;Yi, Joonhwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.7
    • /
    • pp.181-190
    • /
    • 2013
  • We propose an interpolation method considering barrel distortion of fisheye lens using nearest pixels on a corrected image. The correction of barrel distortion comprises coordinate transformation and interpolation. This paper focuses on interpolation. The proposed interpolation method uses nearest four coordinates on a corrected image rather than on a distorted image unlike existing techniques. Experimental results show that both subjective and objective image qualities are improved.

A Hardware Design for Realtime Correction of a Barrel Distortion Using the Nearest Pixels on a Corrected Image (보정 이미지의 최 근접 좌표를 이용한 실시간 방사 왜곡 보정 하드웨어 설계)

  • Song, Namhun;Yi, Joonhwan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.12
    • /
    • pp.49-60
    • /
    • 2012
  • In this paper, we propose a hardware design for correction of barrel distortion using the nearest coordinates in the corrected image. Because it applies the nearest distance on corrected image rather than adjacent distance on distorted image, the picture quality is improved by the image whole area, solve the staircase phenomenon in the exterior area. But, because of additional arithmetic operation using design of bilinear interpolation, required arithmetic operation is increased. Look up table(LUT) structure is proposed in order to solve this, coordinate rotation digital computer(CORDIC) algorithm is applied. The results of the synthesis using Design compiler, the design of implementing all processes of the interpolation method with the hardware is higher than the previous design about the throughput, In case of the rear camera, the design of using LUT and hardware together can reduce the size than the design of implementing all processes with the hardware.

A Study on the Development of Search Algorithm for Identifying the Similar and Redundant Research (유사과제파악을 위한 검색 알고리즘의 개발에 관한 연구)

  • Park, Dong-Jin;Choi, Ki-Seok;Lee, Myung-Sun;Lee, Sang-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.11
    • /
    • pp.54-62
    • /
    • 2009
  • To avoid the redundant investment on the project selection process, it is necessary to check whether the submitted research topics have been proposed or carried out at other institutions before. This is possible through the search engines adopted by the keyword matching algorithm which is based on boolean techniques in national-sized research results database. Even though the accuracy and speed of information retrieval have been improved, they still have fundamental limits caused by keyword matching. This paper examines implemented TFIDF-based algorithm, and shows an experiment in search engine to retrieve and give the order of priority for similar and redundant documents compared with research proposals, In addition to generic TFIDF algorithm, feature weighting and K-Nearest Neighbors classification methods are implemented in this algorithm. The documents are extracted from NDSL(National Digital Science Library) web directory service to test the algorithm.

EFFECT OF WALL PROXIMITY ON DRAG AND LIFT FORCES ON A CIRCULAR CYLINDER (벽 근접 효과에 의한 물체의 항력 양력 변화)

  • Park, Hyun-Wook;Lee, Chang-Hoon;Choi, Jung-Il
    • Journal of computational fluids engineering
    • /
    • v.17 no.3
    • /
    • pp.68-74
    • /
    • 2012
  • Near-wall effect on wakes behind particles is one of the important factors in precise tracking of particles in turbulent flows. However, most aerodynamic force models for particles did not fully consider the wall effect. In the present study, we focused on changes of hydrodynamic forces acting on a particle depending on wall proximity. To this end, we developed an immersed boundary method with multi-direct forcing incorporated to a fully implicit decoupling procedure for incompressible flows. We validate the present immersed boundary method through two-dimensional simulations of flow over a circular cylinder. Comprehensive parametric studies on the effect of the wall proximity on the drag and lift forces acting on an immersed circular cylinder in a channel flow are performed in order to investigate general flow patterns behind the circular cylinder for a wide range of Reynolds number (0.01 ${\leq}$ Re ${\leq}$ 200). As the cylinder is closer to the wall, the drag coefficient decreases while the lift coefficient increases with a local maximum. Maximum drag and lift coefficients for different wall proximities decrease with increment of Reynolds number. Normalized drag and lift coefficients by their maximum values show universal correlations between the coefficients and wall proximity in a low Reynolds number regime (Re ${\leq}$ 1).

Carotid Intima-Media Thickness Measurement in Obese Children (비만 소아들에서의 경동맥 내막중막 두께 측정)

  • Park, Kyung Ok;Choi, Suk Ju;Yeom, Hee Hyun;Chung, Sochung;Yu, Jeong Jin;Park, Youngshin;Lee, Dong Hwan
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.9
    • /
    • pp.935-938
    • /
    • 2005
  • Purpose : The aim of the present study was to ascertain whether the increase of carotid intima-media thickeness(cIMT) as one of premature pathologic changes of atherosclerosis, was present in obese children compared to normal weight children. Methods : The obese group consisted of 21 obese/overweight(body mass index(BMI) above 85 percentile of age, sex standards) children and the control group of 11 normal weight children. None of the children had any chronic illnesses or previous medication history. We investigated the age, sex, height, weight, and systolic/diastolic blood pressure. We measured cIMT by ultrasonogram. In 19 of the obese group, we tested the serum glucose level, liver transaminase level, and cholesterol level etc. Results : The increase of cIMT in obese group did not achieved statistical significance(obese group vs. control group; 0.42 vs. 0.40 mm, P=0.0592). In addition, cIMT showed no significant correlation with any physical/laboratory variables including BMI(P=0.0585). Conclusion : To our knowledge, this is the first study to measure the cIMT in Korean children. Though the results approached statistical significance, we could not prove an increase of cIMT in obese children or an association between cIMT and BMI, due to the study's small sample size. In the future, larger and more extensive trials are needed.

A Study on the Analysis of Non-point Source Runoff Characteristics and Verification of Unit Pollutant Load Considering Baseflow Runoff (기저유출을 고려한 비점오염 유출특성 분석과 원단위 검증에 관한 연구)

  • Park, Jaebeom;Kal, Byungseok;Lee, Chulgu;Hong, Seonhaw;Choi, Moojin
    • Journal of Wetlands Research
    • /
    • v.19 no.3
    • /
    • pp.279-286
    • /
    • 2017
  • In this study, the characteristics of non-point source pollution runoff and the possibility of using new unit load were investigated by using pollutant load based on monitoring data considering baseflow. For this purpose, the components of hydrograph were separated by using digital filter method and the numerical integration method was applied to calculate the non-point source pollutant load for nine rainfall events in Juwon river in the Geum River basin. As a result of this study, the mean contribution rate of non-point pollutant was 31.34% for BOD, 58.94% for T-N, and 50.42% for T-P and BOD was more influenced by baseflow pollutant. Also, it was analyzed the pollutant load using the new unit load is closer to the observation load than the old unit load. This result implies that it is necessary to manage not only pollutant load due to direct runoff but also pollutant load due to baseflow runoff for efficient water quality management of the watershed.

Reverse Design of F-Theta Lens for Compact Laser Scanner (소형 2차원 레이저 스캐너용 F-theta 렌즈 역설계)

  • Choi, Hae Woon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.3
    • /
    • pp.213-218
    • /
    • 2017
  • In this study, a reverse design of the F-theta lens was proposed for a 2D scanner in remote welding applications. The curvature and distance of the lens were set as variables, and the focal length of the lens was set as the marginal ray height. The ZEMAX commercial software was used to perform a simulation with unlimited iterations for the optimization process. The target value was optimized using the internal Merit function with the weight factors of focal length and spot diameter. The number of lenses was four, and the focal length obtained from the results was 135mm that is slightly less than that of the commercial lens, which is set with a focal length of 185 mm. The calculated spot diameters are $1.3{\mu}m$, $6.2{\mu}m$, and $16.1{\mu}m$ for $0^{\circ}$, $12.5^{\circ}$ and $23^{\circ}$ of incident laser beam, respectively. It is expected that an optimized lens design is possible by performing the reverse design of a lens by the ray tracing method.

Drift and Volatilization of Some Pesticides Sprayed on Chinese Cabbages (배추에 살포된 몇 가지 농약제제에 따른 성분의 휘산과 비산)

  • Lee, Ja-Young;Han, Il-Keun;Lee, Sang-Yun;Yeo, Ik-Hyun;Lee, Su-Rae
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.4
    • /
    • pp.373-381
    • /
    • 1997
  • In order to investigate the drift of pesticides sprayed on Chinese cabbage, 7 pesticides chlorpyrifos, EPN, pirimiphos-methyl, phenthoate, tetradifon, dicofol and bifenthrin were applied in two sets of field tests. The pesticide residues were quantified bar multiple-residue analysis, in which the recovery rate was 78${\sim}$92% and standard deviation was ${\pm}0.683{\sim}52%$. It was found that most of the tested pesticides were spread by drift to neighbouring area and brought about the contamination of the unsprayed crops. The extent of drift varied depending upon the pesticide, distance and wind direction. The mean residue levels on unsprayed crops were 0.66% at 3 meter distance, 0.10% at 6 m distance and 0.05% at 9 m distance from the applied area and the maximum level was 1.83% of the residue on sprayed crops.

  • PDF

Global Convergence for Healthcare ICT Services (헬스케어 ICT 서비스의 글로벌 컨버전스)

  • Won, Dal Soo;Lee, Sang San;Jung, Yong Gyu
    • The Journal of the Convergence on Culture Technology
    • /
    • v.2 no.2
    • /
    • pp.45-49
    • /
    • 2016
  • It may be summarized to four kinds of innovation through global convergence, and the convergence of adjacent areas according to mega-trends in medical services market and actively introduced ICT technologies, public and private partnership. Health care is no longer a local industry, it is becoming Global Convergence. In the case of developed countries, it is increased to income levels, the development of new medical technologies, while the increase in specialized medical services and need of aging population. It increases migration of foreign medical personnel, geographical proximity and choice of the best medical technology, regardless of the cost. The increasing demand for high quality yet relatively low foreign prices of medical services. Hospitals are especially spread of international certification such as the US JCI standards. Hospital exports are being evaluated and opened the way for the export industrialization as ICT convergence hospital that can be exported to the fusion-related technologies more efficiently. Current local hospital has already reached saturation, globalization of Korean hospital is being the time necessary. Thus, unlike a strategy for each country, as well as technology transfer it is also possible, such as total exports provided the building, medical equipment procurement, local medical personnel (doctors and nurses) selection and training, PR and marketing. In the current medical law and need to be revised prospectively maintained for publicity and abroad, there is a need for further legal dragons and actively support a more flexible policy on the application of national law overseas medical services.

Comparison of Solidification Pre-treatment Methods for the Determination of δ13C of Dissolved Organic Carbon: Alkaline Persulfate Oxidation-Carbonate Precipitation vs. Freeze Drying (용존유기탄소의 δ13C : 분석시 고형화 전처리 방법 비교 알칼린 과황산칼륨산화 탄산침전과 동결건조)

  • Jeon, Byeong-Jun;Park, Hyun-Jin;Choi, Woo-Jung;Park, Yong-Se;Lee, Sang-Mo;Yoon, Kwang-Sik
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.2
    • /
    • pp.113-118
    • /
    • 2017
  • BACKGROUND: The carbon (C) isotope ratio (${\delta}^{13}C$) of dissolved organic C (DOC) is an indicator of water pollution source. In this study, the potential use of two pre-treatments for the ${\delta}^{13}C$ analysis, alkaline persulfate oxidation coupled with carbonate precipitation (precipitation) and freeze drying (drying), were compared to suggest a more feasible pre-treatment method. METHODS AND RESULTS: Two reference materials with different ${\delta}^{13}C$ values were used for the experiments; chemical grade glucose ($-12.0{\pm}0.02$‰) and pig manure compost extract ($-23.3{\pm}0.04$‰). In the precipitation method, the measured ${\delta}^{13}C$ values were consistently lower than the theoretically calculated values as dissolved $CO_2$ could not be removed due to the alkaline property of the reagents and the dissolution of air $CO_2$ into the alkaline solution. The drying method also resulted in more negative ${\delta}^{13}C$ than the calculated ${\delta}^{13}C$; however, the difference was systematic ($3.9{\pm}0.3$‰) and there was a strong correlation (${\delta}^{13}C_{calculated}=0.87{\times}{\delta}^{13}C_{measured}-0.624$, $r^2=0.98$) between the calculated and measured ${\delta}^{13}C$. Calibration of ${\delta}^{13}C$ using the relationship between the calculated and the measured ${\delta}^{13}C$ values produced reliable and accurate ${\delta}^{13}C$ values. CONCLUSION: Our results suggest that the drying method is more accurate pre-treatment method to minimize the influence of air $CO_2$ compared to the precipitation method for the determination of ${\delta}^{13}C$ of DOC.