• Title/Summary/Keyword: K-$\varepsilon$ model

Search Result 750, Processing Time 0.032 seconds

Efficiency of Different Roof Vent Designs on Natural Ventilation of Single-Span Plastic Greenhouse (플라스틱 단동온실의 천창 종류에 따른 자연환기 효과)

  • Rasheed, Adnan;Lee, Jong Won;Kim, Hyeon Tae;Lee, Hyun Woo
    • Journal of Bio-Environment Control
    • /
    • v.28 no.3
    • /
    • pp.225-233
    • /
    • 2019
  • In the summer season, natural ventilation is commonly used to reduce the inside air temperature of greenhouse when it rises above the optimal level. The greenhouse shape, vent design, and position play a critical role in the effectiveness of natural ventilation. In this study, computational fluid dynamics (CFD) was employed to investigate the effect of different roof vent designs along with side vents on the buoyancy-driven natural ventilation. The boussinesq hypothesis was used to simulate the buoyancy effect to the whole computational domain. RNG K-epsilon turbulence model was utilized, and a discrete originates (DO) radiation model was used with solar ray tracing to simulate the effect of solar radiation. The CFD model was validated using the experimentally obtained greenhouse internal temperature, and the experimental and computed results agreed well. Furthermore, this model was adopted to compare the internal greenhouse air temperature and ventilation rate for seven different roof vent designs. The results revealed that the inside-to-outside air temperature differences of the greenhouse varied from 3.2 to $9.6^{\circ}C$ depending on the different studied roof vent types. Moreover, the ventilation rate was within the range from 0.33 to $0.49min^{-1}$. Our findings show that the conical type roof ventilation has minimum inside-to-outside air temperature difference of $3.2^{\circ}C$ and a maximum ventilation rate of $0.49min^{-1}$.

Effects of Meteorological and Reclaiming Conditions on the Reduction of Suspended Particles (기상 조건과 매립 조건이 비산 먼지 발생에 미치는 영향)

  • Choi, Jae-Won;Lee, Young-Su;Kim, Jae-Jin
    • Journal of Environmental Science International
    • /
    • v.19 no.11
    • /
    • pp.1423-1436
    • /
    • 2010
  • The effects of meteorological and reclaiming conditions on the reduction of suspended particles are investigated using a computational fluid dynamics (CFD) model with the k-$\varepsilon$ turbulence closure scheme based on the renormalization group (RNG) theory. Twelve numerical experiments with different meteorological and reclaiming conditions are performed. For identifying the meteorological characteristics of the target area and providing the inflow conditions of the CFD model, the observed data from the automatic weather station (AWS) near the target area is analyzed. Complicated flow patterns such as flow distortion, horse-shoe vortex, recirculation zone, and channeling flow appeared due to the topography and buildings in the domain. Specially, the flow characteristics around the reclamation area are affected by the reclaiming height, reclaiming size and windbreak height. Reclaiming height affected the wind speed above the reclaiming area. Windbreak induces more complicated flow patterns around the reclaiming area as well as within the reclaiming area. In front of the windbreak, flow is distorted as it impinges on the windbreak. As a result, upward flow is generated there. Behind the windbreak, a secondary circulation, so called, a recirculation zone is generated and flow is reattached at the end of the recirculation zone (reattachment point). At the lower part of the recirculation zone, there is a reverse flow toward the windbreak. Flow passing to the reattachment point starts to be recovered. Total amounts of suspended particles are calculated using the frictional and threshold frictional velocities, erosion potential function, and the number of surface disturbance. In the case of a 10 m-reclaiming and northerly wind, the amount of suspended particles is largest. In the presence of 5 m windbreak, the friction velocity above the reclaiming area is largely reduced. As a result, the total amount of the suspended particles largely decreases, compared to the case with the same reclaiming and meteorological conditions except for the windbreak The calculated suspended particle amounts are used as the emission rate of the dispersion model simulations and the dispersion characteristics of the suspended particles are analyzed.

Mapping the water table at the Cheongju-Gadeok site of the Korea National Groundwater Monitoring Network using multiple geophysical methods

  • Ju, Hyeon-Tae;Sa, Jin-Hyeon;Kim, Ji-Soo
    • The Journal of Engineering Geology
    • /
    • v.27 no.3
    • /
    • pp.305-312
    • /
    • 2017
  • The most effective way to distinguish subsurface interfaces that produce various geophysical responses is through the integration of multiple geophysical methods, with each method detecting both a complementary and unique set of distinct physical properties relating to the subsurface. In this study, shallow seismic reflection (SSR) and ground penetrating radar (GPR) surveys were conducted at the Cheongju-Gadeok site of the Korea National Groundwater Monitoring Network to map the water table, which was measured at 12 m depth during the geophysical surveys. The water table proved to be a good target reflector in both datasets, as the abrupt transition from the overlying unsaturated weathered rock to the underlying saturated weathered rock yielded large acoustic impedance and dielectric constant contrasts. The two datasets were depth converted and integrated into a single section, with the SSR and GPR surveys conducted to ensure subsurface imaging at approximately the same wavelength. The GPR data provided detailed information on the upper ~15 m of the section, whereas the SSR data imaged structures at depths of 10-45 m. The integrated section thus captured the full depth coverage of the sandy clay, water table, weathered rock, soft rock, and hard rock structures, which correlated well with local drillcore and water table observations. Incorporation of these two geophysical datasets yielded a synthetic section that resembled a simplified aquifer model, with the best-fitting seismic velocity, dielectric constant, and porosity of the saturated weathered layer being $v_{seismic}=1000m/s$, ${\varepsilon}_r=16$, and ${\phi}=0.32$, respectively.

Analysis of Grain Boundary Phenomena in ZnO Varistor Using Dielectric Functions (유전함수를 이용한 ZnO 바리스터의 입계 특성 분석)

  • Hong, Youn-Woo;Shin, Hyo-Soon;Yeo, Dong-Hun;Kim, Jong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.178-178
    • /
    • 2008
  • ZnO 바리스터는 인가되는 전압에 따라 저항이 변하는 전압 의존형 저항체이며 각종 전기 전자 정보통신용 제품에 정전기(ESD) 대책용 소자로 폭 넓게 사용되는 전자 세라믹스 부품이다. 특별히 Bi-based ZnO 바리스터는 다양한 상(phase)으로 구성되어 있으며 그 입계의 전기적 특성은 소량 첨가되는 dopant의 종류에 따라 다양하게 변하는 것으로 알려져 있다. 본 연구에서는 Bi-based ZnO 바리스터 (ZnO-$Bi_2O_3$, ZnO-$Bi_2O_3-Mn_3O_4$)에서 각종 유전함수$(Z^*,M^*,\varepsilon^*,Y^*,tan{\delta})$를 이용하여 입계의 주파수-온도에 대한 특성을 살펴 보았다. 일반적인 ZnO 바리스터 제조법으로 시편을 제작하여 78K~800K 온도 범위에서 각종 유전함수를 이용하여 복소 평면도(complex plane plot)와 주파수 응답도(frequency explicit plot)의 방법으로 defect level과 입계 특성(활성화 에너지, 정전용량, 저항, 입계 안정성 등)에 대하여 고찰하였다. ZnO-$Bi_2O_3$(ZB)계와 ZnO-$Bi_2O_3-Mn_3O_4$(ZBM)계 모두 상온 이하의 온도에서 $Zn_i$$V_o$의 결함이 나타났으며, 이들의 결함 준위는 각 유전함수에 따라 다소 차이가 났다. 입계 특성으로 ZB계는 이상구간(560~660K)을 전후로 1.15 eV $\rightarrow$ 1.49 eV의 활성화 에너지의 변화가 나타났지만, ZBM계는 이러한 현상이 나타나지 않았다. 또한 입계 전위 장벽의 온도 안정성에 대해서는 Cole-Cole model을 적용하여 분포 파라미터 (distribution parameter; $\alpha$)를 구하여 고찰하였다. ZB계의 입계 안정성은 온도에 따라 불안정해 졌지만, ZBM계는 안정하였다.

  • PDF

A combination method to generate fluctuating boundary conditions for large eddy simulation

  • Wang, Dayang;Yu, X.J.;Zhou, Y.;Tse, K.T.
    • Wind and Structures
    • /
    • v.20 no.4
    • /
    • pp.579-607
    • /
    • 2015
  • A Combination Random Flow Generation (CRFG) technique for obtaining the fluctuating inflow boundary conditions for Large Eddy Simulation (LES) is proposed. The CRFG technique was developed by combining the typical RFG technique with a novel calculation of k and ${\varepsilon}$ to estimate the length- and time-scales (l, ${\tau}$) of the target fluctuating turbulence field used as the inflow boundary conditions. Through comparatively analyzing the CRFG technique and other existing numerical/experimental results, the CRFG technique was verified for the generation of turbulent wind velocity fields with prescribed turbulent statistics. Using the turbulent velocity fluctuations generated by the CRFG technique, a series of LESs were conducted to investigate the wind flow around S-, R-, L- and U-shaped building models. As the pressures of the models were also measured in wind tunnel tests, the validity of the LES, and the effectiveness of the inflow boundary generated by the CRFG techniques were evaluated through comparing the simulation results to the wind tunnel measurements. The comparison showed that the LES accurately and reliably simulates the wind-induced pressure distributions on the building surfaces, which indirectly validates the CRFG technique in generating realistic fluctuating wind velocities for use in the LES. In addition to the pressure distribution, the LES results were investigated in terms of wind velocity profiles around the building models to reveal the wind flow dynamics around bluff bodies. The LES results quantitatively showed the decay of the bluff body influence when the flow moves away from the building model.

The Study on Natural Ventilation in Working Places with the Noxious Gas and Dust (유해가스 및 분진이 발생하는 작업장내의 자연환기에 대한 연구)

  • Chu, Byung-Gil;Kim, Chul;Choi, Jong-ook;Yoo, Soo-Yul
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.1
    • /
    • pp.72-79
    • /
    • 2000
  • In recent, occupational diseases in harmful working places become a social issue. It is the well-known fact that a respiration in polluted working places exert a serious effect on health of workers. Accordingly, the cutting off contaminants air originally is the best way to improve working environments. In these cases, ventilation systems should be essentially installed to dilute or exhaust the contaminated indoor air. In this study, we investigated the characteristics of ventilation system of the noxious gas in working indoor places with natural ventilation by using COMET. The numerical simulations were carried out the natural ventilation with two phase(air, dust). For turbulent flow, Reynolds stresses were closed by the standard $\kappa$-$\varepsilon$ model. The results are as follows ; 1) In the natural exhaust in the working place, the flows of the central region have a more rapid velocity vector than the right and left one. 2) Numerical results show that the distribution of contaminants concentration have greater influence on convection than the case of diffusion by government of velocity vectors. 3) To observe the velocity variation with distance, three location of distance are considered. As results, it shows that the velocity are 0.075(m/s) at y=5(m), 10(m) and mean concentration are raised 10.6% at y=5(m), 10(m). 4) We have presented the useful data for the adequate counterplan in the harmful working places by carrying out the various investigation of the natural ventilation.

  • PDF

Numerical Analysis for the Pressure and Flow Fields past a Two-Staged Conical Orifice (이단 원추형 오리피스를 지나는 압력장과 유동장에 관한 수치적 연구)

  • Kim, Yeon-Su;Kim, Yu-Gon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.2
    • /
    • pp.278-287
    • /
    • 2002
  • The objective of the paper was to calculate the pressure drop and to investigate the recirculation region of the conical orifices used in Kwang-yang Iron & Steel Company. The flow field with water used as a working fluid was the turbulent flow for Reynolds number of 2$\times$10$^4$. The effective parameters fur the pressure drop and the recirculation region were the conical orifice\`s inclined angle ($\theta$) against the wall, the interval(S) between orifices, the relative angle of rotation($\alpha$) of the orifices, the shape of the orifice's hole(circle, rectangle, triangle) having the same area, the number(N) of the orifice's holes having the same mass flow rate, and the thickness(t) of the orifices. It was fecund that the shape of the orifice's hole, the number of the orifice's holes and the thickness of the orifice affected the total pressure drop a lot and that the conical orifice's inclined angle against the wall, the relative angle of rotation of the orifices, the number of the orifice's holes and the thickness of the orifices affected the center location of the recirculation region. The PISO algorithm with FLUENT code was employed to analyze the flow field.

Genesis of the REE Ore Deposits, Chungju District, Korea: Occurrence Features and Geochemical Characteristics (충주지역 희토류 광상의 성인: 산출상태와 지화학적 특성)

  • Park, Maeng-Eon;Kim, Gun-Soo
    • Economic and Environmental Geology
    • /
    • v.28 no.6
    • /
    • pp.599-612
    • /
    • 1995
  • Some REE ore deposits are located in the middle part the of Korean peninsula. Geotectonically, the REE ore deposits situated on the Kyemyeongsan Formation of northern margin of the Okcheon geosynclinal belt and in the transitional zone between Kyeonggi massif and the Okcheon belt, with a deep-seated fracture separating the two tectonic units. The Kyemyeongsan Formation are different in lithology and metamorphic grade from the Gyeonggi massif and the Okcheon super group. The sequence of Kyemyeongsan Formation is dominantly composed of acidic metavolcanic and volcaniclastic rocks associated with alkaline igneous rocks which are related to volcano-plutonism. The REE ore deposits contain mainly Ce-La, Ta-Nb, Y, Y-Nd and Nd-Th group minerals. More than 15 RE and REE minerals have been found in the deposits, such as allanite, fergusonite, thorite bestnaesite, euxenite, polyclase, monazite, columbite, (Nb)-rutile, okanoganite, sphene, zircon, illmenite and some other unknown minerals. According to the characteristics of the mineral association, the REE ore deposits may be divided into 4 ore types; Zircon-REE, allanite-REE, feldspar-REE and fluorite-REE type. The Sm-Nd isochron age of the REE ore is 330 Ma, and the Sm-Nd model age is 1.11 Ga with ${\varepsilon}_{Nd(t)}$ being - 2.9. This data suggest that the REE ore deposit was formed in the early Carboniferous, and the ore-forming material came from the mantle. The REE ores show distinct light REE enrichment with strong negative Eu anomaly. The REE patterns of schistose rocks from Kyemyeongsan Formation are similar to felsic volcanics from rifts or back arc basins in or near continental crust. The genesis of the REE ore deposit is quite complicated. Different geologic processes are displayed in the studied area; sedimentation, volcanic activity, metamorphism and hydrothermal replacement. Alkali granite has suffered extensive post-magmatic metasomatism of a high temperature to produce alkali metasomatites. Geochemical charateristics show that metasomatism of alkaline fluid was probably the dominant ore-forming process in Chungju district.

  • PDF

A Numerical Study of the 2-D Cold Flow for a Qubec City Stoker Incinerator (큐벡시 스토커 소각로 2차원 비반응 유동장 수치해석)

  • 박지영;송은영;장동순
    • Journal of Energy Engineering
    • /
    • v.2 no.3
    • /
    • pp.268-275
    • /
    • 1993
  • A series of parametric investigations are performed in order to resolve the flow characteristic of a Quebec city stoker incinerator. The parameters considered in this study are five internal configurations of the Quebec city stoker itself and its modified ones, primary air velocity, the injection velocity and angle of the secondary air, and the reduction of the stoker exit area. A control-volume based finite-difference method by Patankar together with the power-law scheme is employed for discretization. The resolution of the pressure-velocity coupling is made by the use of SIMPLEC algorithm. The standard, two equation, k-$\varepsilon$ model is incorporated for the closure of turbulence. The size of recirculation region, turbulent viscosity, the mass fraction of the secondary air and pressure drop are calculated in order to analyze the characteristics of flow field. The results are physically acceptable and discussed in detail. The flow field of the Quebec city stoker shows the strong recirculation zone together with the high turbulence intensity over the upper part of the incinerator.

  • PDF

CFD Analysis on Base Region of Small Scaled 4 Nozzle Clustered Engine Configuration (CFD를 이용한 축소형 공기 클러스터드 노즐의 저부 유동 분석)

  • Kim, Seong-Lyong;Kim, In-Sun
    • Aerospace Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.68-77
    • /
    • 2012
  • Flow characteristics of base region of small scaled 4 nozzle clustered engine has been analyzed with CFD approach along with the tests of numerical methods. The numerical test shows that Spalart-Allmaras turbulence model is appropriate for the present research. Plumes expanded from nozzles exits collide with each other and make high pressure stagnation region. Some of collided plumes expand again reversely into the base region with supersonic speeds. The reversed plume in the base region goes out to the outer region through the minimum vent area formed by the nearest nozzle exterior surfaces. But different from the empirical theory, the minimum vent area does not play a role of throat. Additionally the temperature of the nozzle inner surface strongly affects the temperature of the reversed plumes.