• 제목/요약/키워드: K ion detection

검색결과 477건 처리시간 0.033초

Application of Malononitrile Derivatization Method for Structural Glycomics Study in Matrix-assisted Laser Desorption/Ionization Time-of-flight Mass Spectrometry

  • Ahn, Yeong-Hee;Yoo, Jong-Shin
    • Journal of Photoscience
    • /
    • 제8권2호
    • /
    • pp.83-86
    • /
    • 2001
  • Structural analyses of oligosaccharide-malononitrile derivatives were conducted by matrix-assisted laser desorption/ionization post-source decay (MALDI-PSD) analysis in positive ion mode. The malononitrile derivatives of oligosaccharides, which were developed for highly sensitive detection of multi-component oligosaccharides by negative ion electrospray ionization mass spectrometry (ESI MS), were detected by positive-ion MALDI with the detection limit of 2 pmol level from the crude derivatization sample. The used matrix affected drastically the analytical results of oligosaccharide-malononitrile derivative by matrix-assisted laser desoprtion/ionization mass spectrometry (MALDI MS). The malononitrile derivatization of oligosaccharide also affect the patterns of MALDI-PSD spectra and give much more structural information than the free oligosaccharide.

  • PDF

미량원소 분석을 위한 GD/MS 이온원의 개발에 관한 연구 (Development of the Ion Source of Glow Discharge/Mass Spectrometry for the determination of trace elements)

  • 우진춘;임흥빈;문대원;이광우;김효진
    • 분석과학
    • /
    • 제5권2호
    • /
    • pp.169-176
    • /
    • 1992
  • 금속시료의 미량원소를 분석하기 위하여 jet형과 글로우방전 이온원을 제작하여 질량 분석기와 연결시킨 후 상대이온세기와 검출한계를 측정하였다. Jet형 이온원으로 구리시료의 시료 손실속도를 측정하였을 때 가스흐름속도가 0.01L/min이었을 때 0.23 mg/min이고 가스흐름이 없을 때는 0.11 mg/min이었다. 그러나 구리의 이온세기를 측정하였을 때는 두 이온원에서 큰 차이가 없었다. 여섯 개의 동합금시료의 검정곡선으로부터 구한 각 원소의 상대이온세기는 철의 0.57부터 크롬의 3.5 범위였다. Jet형 이온원으로 4mA, 1000V 방전시 순수 구리시료의 각 원소에 대한 검출한계는 0.9 ppm에서 2 ppm 수준으로 나타났다.

  • PDF

이온 선택성 미소전극과 전위계를 이용한 신호 계측 시스템의 특성 평가 (Characterization of Signal Measuring System Using ion Selective Microelectrode and Electrometer)

  • 전효용;선경숙;박정진;변임규;박태주
    • 대한환경공학회지
    • /
    • 제28권11호
    • /
    • pp.1148-1153
    • /
    • 2006
  • 이온 선택성 미소전극과 전위계를 이용하여 생물막내 이온 농도 측정을 위한 신호 계측 시스템을 구성하였다. 제작된 신호 계측 시스템의 성능과 적용성을 평가하기 위하여 보정곡선의 기울기, 검출한계, 시간경과에 따른 응답신호의 변화, 전위차 선택계수를 조사하였다. 보정곡선의 기울기는 목적이온 농도에 밀접한 비례관계를 나타내었다. 신호 계측 시스템은 $10{\mu}M$ 이하의 낮은 검출한계를 가졌으며, 실험에 사용된 방해이온에 민감하지 않았다. 본 연구에서 제작된 전위계는 상용되는 전위계와의 성능을 비교하였을 때 보정곡선 기울기, 검출한계, 응답시간에서 비슷한 경향을 나타내었다. 본 연구에서 제작된 신호 계측 시스템은 생물막내 이온농토 측정 연구를 위한 경제적이며 신뢰성 있는 시스템으로 사용될 수 있을 것이다.

수경재배용 배양액의 이온성분 분석을 위한 고체형 센서 모듈 개발 (Development of a Solid State Ion Sensor Module for Analysis of Hydroponic Nutrients)

  • 김기영;이상봉;장영창
    • Journal of Biosystems Engineering
    • /
    • 제32권5호
    • /
    • pp.348-353
    • /
    • 2007
  • A solid state ion sensor module has been developed and evaluated for hydroponic nutrients analysis. The sensor module consisted of five ion-selective electrodes (ISE) fabricated by screen-printing technology. The electrochemical responses of ion sensors for nitrate, ammonium, potassium, calcium, and pH were measured with specially designed 7-channel low voltage signal transducers. The analytical characteristics of the sensors were comparable with those of conventional ISE sensors. The solid state ion sensors exhibit linear relationships over five concentration decades. Detection limit of the sensors were $5.6{\times}10^{-5}{\sim}1.6{\times}10^{-7}M$ depends on ions. Performance test results showed that relative errors of measured ion concentrations were less than 5% for $NO_3{^-},\;K^+,\;Ca^{2+}$ ion, and pH. The concentration of $NO_3{^-},\;NH_4{^+},\;K^+,\;Ca^{2+}$, and pH ion in standard solution and nutrient solutions could be determined by direct potentiometric measurements without any conditioning before measurements.

오염된 QMS의 원인 분석과 세정 및 기능 복원 (Analysis of contaminated QMS, cleaning and restoration of functions)

  • 김동훈;주정훈
    • 한국표면공학회지
    • /
    • 제48권4호
    • /
    • pp.179-184
    • /
    • 2015
  • Quadrupole Mass Spectrometers (QMS) is a very useful tool in vacuum process diagnosis. Tungsten filament based ion sources are vulnerable to contamination from process gas monitoring. Common symptoms of quadrupole mass spectrometer malfunction is appearance of unwanted contaminant mass peaks or no detection of any ion peaks. We disassembled used quadrupole mass spectrometer and found out black insulating deposits on inside of ion source parts. Five steps of cleaning procedure were applied and almost full restoration of functions were confirmed in two types of closed ion source quadrupole mass spectrometer. By using a numerical modeling (CFD-ACE+) technique, the electric potential profile of ion source with/without insulating deposit was calculated and showed the possibility of quadrupole mass spectrometer malfunction by the deterioration of designed potential profile inside the ion source.

Incipient Fault Detection of Reactive Ion Etching Process

  • Hong, Sang-Jeen;Park, Jae-Hyun;Han, Seung-Soo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제6권6호
    • /
    • pp.262-271
    • /
    • 2005
  • In order to achieve timely and accurate fault detection of plasma etching process, neural network based time series modeling has been applied to reactive ion etching (RIE) using two different in-situ plasma-monitoring sensors called optical emission spectroscopy (OES) and residual gas analyzer (RGA). Four different subsystems of RIE (such as RF power, chamber pressure, and two gas flows) were considered as potential sources of fault, and multiple degrees of faults were tested. OES and RGA data were simultaneously collected while the etching of benzocyclobutene (BCB) in a $SF_6/O_2$ plasma was taking place. To simulate established TSNNs as incipient fault detectors, each TSNN was trained to learn the parameters at t, t+T, ... , and t+4T. This prediction scheme could effectively compensate run-time-delay (RTD) caused by data preprocessing and computation. Satisfying results are presented in this paper, and it turned out that OES is more sensitive to RF power and RGA is to chamber pressure and gas flows. Therefore, the combination of these two sensors is recommended for better fault detection, and they show a potential to the applications of not only incipient fault detection but also incipient real-time diagnosis.

흡착벗김 전압전류법에 의한 시안화이온의 정량 (Determination of Cyanide Ion by Adsorptive Stripping Voltammetry)

  • 차기원;고수진;김재균
    • 분석과학
    • /
    • 제14권6호
    • /
    • pp.540-544
    • /
    • 2001
  • Determination of cyanide ion has been studied by adsorptive stripping voltammetry using hanging mercury electrode. Cyanide ion complexed with copper ion is adsorpbed on the electrode and oxidised at the positive potential scan. Optimal conditions of CN determination were found to be ; supporting electrolyte solution ; 0.1 M NaCl of ammonium buffer at pH 10, accumulation potential; -800 mV vs Ag/AgCl, accumulation time ; 300 s, scan rate ; 50mV/s. The linear concentration of cyanide ion was observed in the range $1{\times}10^{-8}$, $1{\times}10^{-7}M$. The detection limit(n/s=3) was $0.13{\mu}g/L$($5{\times}10^{-9}M$) with 3.5% RSD.

  • PDF

전기자동차용 리튬이온전지를 위한 SOC 추정 및 센서 고장검출 (Estimation of State-of-charge and Sensor Fault Detection of a Lithium-ion Battery in Electric Vehicles)

  • 한만유;이기상
    • 전기학회논문지
    • /
    • 제63권8호
    • /
    • pp.1085-1091
    • /
    • 2014
  • A model based SOC estimation scheme using parameter identification is described and applied to a Lithium-ion battery module that can be installed in electric vehicles. Simulation studies are performed to verify the effect of sensor faults on the SOC estimation results for terminal voltage sensor and load current sensor. The sensor faults should be detected and isolated as soon as possible because the SOC estimation error due to any sensor fault seriously affects the overall performance of the BMS. A new fault detection and isolation(FDI) scheme by which the fault of terminal voltage sensor and load current sensor can be detected and isolated is proposed to improve the reliability of the BMS. The proposed FDI scheme utilizes the parameter estimation of an input-output model and two fuzzy predictors for residual generation; one for terminal voltage and the other for load current. Recently developed dual polarization(DP) model is taken to develope and evaluate the performance of the proposed FDI scheme. Simulation results show the practical feasibility of the proposed FDI scheme.

목표물질 스크리닝을 위한 피이크 인식 알고리즘 (A Peak Recognition Algorithm for the Screening of Target Compounds)

  • 민홍기;홍승홍
    • 대한의용생체공학회:의공학회지
    • /
    • 제14권2호
    • /
    • pp.185-193
    • /
    • 1993
  • In this paper, the peak detection algorithm was developed for the purpose of screening of the target compounds. Algorithm is divided into searching the characteristic ion and peak detection. The heuristic knowledge about analytical chemistry was applied for the searching the characteristic ion. Peak detection was accomplished in comparison with the peak identification strings and pattern strings around the retention time. Pattern strings are composed with the number which generated by pattern identification function. The variables of pattern identification function are the codes which represent the difference of two adjacent abundances Some of the free steroids were selected to demonstrate the proposed algorithm.

  • PDF