• Title/Summary/Keyword: K

Search Result 755,427, Processing Time 0.257 seconds

Bone Mineral Density of Normal Korean Adult Using QCT (적량적 전산화단층촬영을 이용한 한국인의 골밀도)

  • Lee Jong Deok
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.18 no.6
    • /
    • pp.1918-1926
    • /
    • 2004
  • Osteoporosis is defined as a progressive systemic skeletal disorder characterized by low bone mineral density, microarchitectual deteriorations of bone and susceptibility to fracture. numerous methods have been used for quantitative assessment of the skeleton in osteoporosis. QCT has been shown to measure changes in trabecular mineral content in the spine with great sensitivity and precision. To provide the normal reference values and changes of lumbar spinal bone mineral density in korean adult spinal bone mineral density was evaluated in 451 women (229 premenopausal and 222 postmenopausal women) and 206 men, aged 20 to 74 years old in Wonkwang hospital from 2000 to 2004, which was carried out by using QCT. women with oophorectomy, vertebral compression fracture, any history of endocrine disease and use of drugs that alter bone metabolism were excluded. According to the WHO definition, a patient is osteoporotic based on a bone mineral density(BMD) measurement that is 2.5 standard deviations (SDs) below typical peak bone mass of young healthy white women. This measurement of standard deviation from peak mass is called the T score. BMD values of normal women in their 20-24 years, 25-29 years, 30-34 years, 35-39 years, 40-44 years, 45-49 years, 50-54 years, 55-59 years, 60-64 years, 65-69 years, over 70 years were 168.95㎎/㏄ K₂PHO₄, 155.41㎎/㏄ K₂PHO₄, 166.87㎎/㏄ K₂PHO₄, 160.67㎎/㏄ K₂PHO₄, 154.06㎎/㏄ K₂PHO₄, 132.04㎎/㏄ K₂PHO₄, 114.05㎎/㏄ K₂PHO₄, 91.78㎎/㏄ K₂PHO₄, 78.61 ㎎/㏄ K₂PHO₄, 61.35㎎/㏄ K₂PHO₄, 50.53㎎/㏄ K₂PHO₄ Mean bone density of normal women was 115.77K₂PHO₄ K₂PHO₄. BMD values of normal men in their 20-24 years, 25-29 years, 30-34 years, 35-39 years, 40-44 years, 45-49 years, 50-54 years, 55-59 years, 60-64 years, 65-69 years, over 70 years were 171.46㎎/㏄ K₂PHO₄, 162.19㎎/㏄ K₂PHO₄, 155.62㎎/㏄ K₂PHO₄, 147.28㎎/㏄ K₂PHO₄, 137.56㎎/㏄ K₂PHO₄, 137.56㎎/㏄ K₂PHO₄, 101.25㎎/㏄ K₂PHO₄, 109.00㎎/㏄ K₂PHO₄, 103.32㎎/㏄ K₂PHO₄, 91.53㎎/㏄ K₂PHO₄, 88.35㎎/㏄ K₂PHO₄ Mean density of normal men was 115.77㎎/㏄ K₂PHO₄. Peak bone density of women and men was in the age group of 20-24 years and 168.95㎎/㏄ K₂PHO₄, 171.46㎎/㏄ K₂PHO₄, respectively. Bone loss was increased with aging and was accelerated in postmenopausal women than that of premenopausal women. The total loss of BMD for women and men was 70.09% and 48.47%, respectively. Postmenopausal women(mean BMD : 85.83㎎/㏄ K₂PHO₄) had significantly lower BMD than premenopausal women(meand BMD : 144.80㎎/㏄ K₂PHO₄)(p<0.001). The annual loss of BMD of women and men was 2.702㎎/㏄ K₂PHO₄ and 1.795㎎/㏄ K₂PHO₄, respectively. This study provided the BMD reference data for normal korean adult. further studies on BMD in healthy adult and comparison with published data are needed.

Kinetics and Mechanism of the Selective Oxidation of Ethylene for Ethylene Oxide over Monolithic Silver Catalyst (모놀리스형 은촉매상에서 에틸렌선택산화반응의 속도론적 고찰)

  • Park, Rho-Bum;Kim, Sang-Chai;Sunwoo, Chang-Sin;Yu, Eui-Yeon
    • Applied Chemistry for Engineering
    • /
    • v.2 no.2
    • /
    • pp.165-174
    • /
    • 1991
  • The kinetics and the mechanism for the selective oxidation of ethylene on the supported monolithic silver catalyst were experimentally investigated in a fixed bed tubular reactor. The formation rates of ethylene oxide and carbon dioxide were measured at the atmospheric pressure with various combinations of partial pressures of ethylene and oxygen at temperature range of $225-300^{\circ}C$, conversion with 1.2-7.5 %, and then the mechanism of the selective oxidation of ethylene was verified. Their formation rates fitted with the Langmuir-Hinshelwood mechnism. The ethylene oxide and carbon dioxide are produced by reation of adsorbed ethylene with monoatomic oxygen adsorbed on the active sites of Ag-surface, and their formation rate equation are expressed as : $R_{EO}={\frac{k_1K_0{^{1/2}}K_EK_SP_{02}{^{3/2}}P_E}{(1+{\sqrt{K_0P_{02}}}+K_EP_E+K_PP_P)^2(1+{\sqrt{K_SP_{02}})^2}}$ $R_C={\frac{k_2K_0{^3}K_EK_S{^{7/2}}P_{02}{^{13/2}}P_E}{(1+{\sqrt{K_0P_{02}}}+K_EP_E+K_PP_P)^7(1+{\sqrt{K_SP_{02}})^7}}$ The activation energies of ethylene oxide and dioxide and carbon dioxide formations can be estimated to be 12.25 and 17.85 Kcal/mol, respectively.

  • PDF

A Study on the Determination of Scan Speed in Whole Body Bone Scan Applying Oncoflash (Oncoflash를 적용한 전신 뼈 영상 검사의 스캔 속도 결정에 관한 연구)

  • Yang, Gwang-Gil;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.56-60
    • /
    • 2009
  • Purpose: The various studies and efforts to develop program are in progress in the field of nuclear medicine for the purpose of reducing scan time. The Oncoflash is one of the programs used in whole body bone scan which allows to maintain the image quality while to reduce scan time. When Those applications are used in clinical setting, both the image quality and reduction of scan time should be considered, therefore, the purpose of this study was to determine the criteria for proper scan speed. Materials and Methods: The subjects of this study were the patients who underwent whole body bone scan at the departments of nuclear medicine in the Asan Medical Center located in Seoul from 1st to 10th, July, 2008. The whole body bone images obtained in the scan speed of 30cm/min were classified by the total counts into under 800 K, and over 800 K, 900 K, 1,000 K, 1,500 K, and 2,000 K. The image quality were assessed qualitatively and the percentages of those of 1,000K and under of total counts were calculated. The FWHM before and after applying the Oncoflash were analyzed using images obtained in $^{99m}Tc$ Flood and 4-Quadrant bar phantom in order to compare the resolution according to the amount of total counts by the application of the Oncoflash. Considering the counts of the whole body bone scan, the dosed 2~5 mCi were used. 152 patients underwent the measurement in which the counts of Patient Postioning Monitor (PPM) were measured with including head and the parts of chest which the starting point of whole body bone scan from 7th to 26th, August, 2008. The correlations with total counts obtained in the scan speed of 30cm/min among them were analyzed (The exclusion criteria were after over six hours of applying isotopes or low amount of doses). Results: The percentage of the whole body bone image which has the geometric average of total counts of under 1,000K among them obtained in the scan speed of 30cm/min were 17.6%(n=58) of 329 patients. The qualitative analysis of the image groups according to the whole body counts showed that the images of under 1,000K were assessed to have coarse particles and increased noises. The analysis on the FWHM of the images before and after applying the Oncoflash showed that, in the case of PPM counts of under 3.6 K, FWHM values after applying the Oncoflash were higher than that before applying the Oncoflash, whereas, in the case of that of over 3.6 K, the FWHM after applying the Oncoflash were not higher than that before applying the Oncoflash. The average of total counts at 2.5~3.0 K, 3.1~3.5 K, 3.6~4.0 k, 4.1~4.5 K, 4.6~5.0 K, 5.1~6.0 K, 6.1~7.0 K, and 7.1 K over (in PPM) were $965{\pm}173\;K$, $1084{\pm}154\;K$, $1242{\pm}186\;K$, $1359{\pm}170\;K$, $1405{\pm}184\;K$, $1640{\pm}376\;K$, $1,771{\pm}324\;K$, and $1,972{\pm}385\;K$, respectively and the correlations between the counts in PPM and the total counts of image obtained in the scan speed of 30 cm/min demonstrated strong correlation (r=.775, p<.01). Conclusions: In the case of PPM coefficient over 3.6 K, the image quality obtained in the scan speed of 30cm/min and after applying the Oncoflash was similar to that obtained in the scan speed of 15 cm/min. In the case of total counts over 1,000 K, it is expected to reduce scan time without any damage on the image quality. In the case of total counts under 1,000 K, however, the image quality were decreased even though the Oncoflash is applied, so it is recommended to perform the re-image in the scan speed of 15 cm/min.

  • PDF