A Study on the microstructure and Surge Characteristics of ZnO varistors for distribution Arrester (배전급 피뢰기용 ZnO 바리스터 소자의 미세구조 및 서지 특성에 관한 연구)

  • 김석수;조한구;박태곤;박춘현;정세영;김병규
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.2
    • /
    • pp.190-197
    • /
    • 2002
  • In this thesis, ZnO varistors with various formulation, such as A∼E, were fabricated according to ceramic fabrication method. The microstructure, electrical properties, and surge characteristics of ZnO varistors were investigated according to ZnO varistors with various formulation. In the microstructure, A∼E\`s ZnO varistor ceramics sintered at 1130$\^{C}$ was consisted of ZnO grain(ZnO), spinel phase (Zn$\_$2.33/Sb$\_$0.67/O$\_$4/), Bi-rich phase(Bi$_2$O$_3$) and intergranuler phase, wholly. Lightning impulse residual voltage of A, B, C and E\`s ZnO varistors suited standard characteristics, below 12kV at current of 5kA. On the contrary, D\`s ZnO varistor exhibited high residual voltage as high reference voltage. In the accelerated aging test, leakage current and watt loss of B, C and D\`s ZnO varistors increases abruptly with stress time under the first a.c. stress(115$\^{C}$/3.213kV/300h). Consequently, C varistor exhibited a thermal run away. On the contrary, leakage current and watt loss of A and C\`s ZnO varistors which show low initial leakage current exhibited constant characteristics. After high current impulse test, A\`s ZnO varistor has broken the side of varistor but impulse current flowed. On the contrary, E\`s ZnO Varistor exhibited good discharge characteristics which the appearance of varistor was not wrong such as puncture, flashover, creaking and other significant damage. After long duration impulse current test, E\`s ZnO varistor exhibited good discharge characteristics which the appearance of varistor was not wrong such as puncture, flashover, creaking and other significant damage. After high current impulse test and long duration impulse current test, E\`s ZnO varistor exhibited very good characteristics which variation rate of residual voltage is 1.4% before and after test.

Epidemiological aspects of Salmonella spp infections of domestic animals in Gyeongbuk province (경북지역 가축에서 Salmonella속 균 감염증에 대한 역학적 특성)

  • Kim, Sang-Yun;Lee, Hee-Moo;Kim, Sin;Hong, Hyon-Pyo;Kwon, Heon-Il
    • Korean Journal of Veterinary Service
    • /
    • v.24 no.1
    • /
    • pp.51-68
    • /
    • 2001
  • The result of studying the epidemiological characteristics of Salmonella strains which have been isolated from the domestic animals in Gyeongbuk province from February 1998 to August 2000 were summarized as follows. The isolation rates of Salmonella strains were 2.0% from cattle feces, 6.3% from cattle lymph node, 9.5% from pig feces, and 25.1% from pig lymph node. In poultry, the isolation rates were 30.3%. The isolates of Salmonella showed positive reaction for MUCAP test, methyl red test, but showed negative reaction for urea test, indole test, Voges Proskauer test. On TSI agar, the isolates showed acid butt, alkaline slant. Also, the isolates were identified as Salmonella strain by API 20E kit. Non H$_2$S Production Salmonella strains isolated from poultry were identified as S gallinarum. As a result of serotyping, B group were the most common in cattle and pig, Dl in chickens. 21 serovars were found. the common serovar from the domestic animals was S typhimurium, S derby, S agona, S schwarzenground, S enteritidis and S gallinarum. The most commonly encountered serovars in cattle were S agona and S typhirimurium in pig, S gallinarum in chicken. As a result of antimicrobial susceptibility test, all Salmonella isolates were susceptible to amikacin, ciprofloxacin, norfloxacin; cefotaxime and polumcin B. The resistance rates to tetracycline and streptomycin was 58% and 56%, respectively. 69.3% of all isolates were resistant to more than one antimicrobial agent. Out of the resistant isolates, the isolates resistant to streptomycin and tetracycline was 36%. There were 24 strains of multiresistant isolates resistant to more than 5 antimicrobial agents. S typhimurium were resistant to all antimicrobial agents, also had a lot of multiresistant strains. Therefore, S typhimurium was considered as a major agent of antimicrobial resistance.

  • PDF

Evaluation on Environmental Bio-toxicity of Industrial Wastewater (산업폐수의 생물독성 발현에 관한 연구)

  • Kim, S.H.;Cheon, S.U.;Shin, K.S.;Jung, D.I.
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.3
    • /
    • pp.274-276
    • /
    • 2005
  • To investigate bioassay for toxic level evaluation of wastewater, toxic levels were checked influents and effluents of 6 wastewater discharge facilities with Daphnia magna and Vibrio fischeri. In view of test duration, D. magna is preferred at 48 hours. And it was judged to efficient that one of the two was choosen for toxicity test method (Daphnia test and Vibrio test). Analysis data for wastewater is average toxic level for influent more higher than effluent. And effluent toxic level is sharp decrease than effluents.

Universal Test Set for Programmable Storage/Logic Arrays (Programmable Storage/Logic Array에 대한 보편적인 Test Set)

  • Do, Yang-Hoe;Gwon, U-Hyeon;Kim, Chae-Yeong
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.1
    • /
    • pp.7-13
    • /
    • 1985
  • Design techniques for programmable storage/logic arrays(SLA's) with easily testable features are discussed. The easily testable SLA's will be designed by using additional hardware to provide an easy means to set or check the states. These augmented SLA's have the very short universal test sequences such that the test patterns and responses are uniquely determined only by the size of the SLA's independently of the function of them. The types of faluts considered here are single and multiple stuck faults, crosspoint faults, and bridge faults in SLA's. Fault location and reapir of SLA's are also considered.

  • PDF

A Type Test of 154 kV Transmission Line Arrester for improvement of lightning performance (내뢰성 향상을 위한 154 kV 송전선용 피뢰기의 성능 시험)

  • Kwak, J.S.;Kang, Y.W.;Woo, J.W.;Shim, E.B.;Kim, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.454-456
    • /
    • 2003
  • This paper describes a type test results of 154 kV transmission line arrester with external gap. The test was carried on surge arrester unit and line arrester with external gap, respectively. Withstand voltage test demonstrate the voltage withstand capability of the line arrester with external series gap under the dry and wet conditions. In insulation coordination test external series gap shall be discharged every time when lightning impulse voltage with the steepness of more than 1500 $kV/{\mu}s$ are applied under the wet condition.

  • PDF

Testing unknown age classes of life distributions based on TTT-transform

  • El-Din, M.M. Mohie;Abu-Youssef, S.E.;Ali, Nahed S.A.
    • International Journal of Reliability and Applications
    • /
    • v.14 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • A nonparametric procedure for testing exponentially against used better than aged in expectation (UBAE) class of life distributions is presented. We construct a test statistics based on scaled total time on test (TTT)-transformation, to test exponentiality against UBAE class of life distributions. The distribution of the statistic is investigated via simulation. Practical applications of the proposed test are presented.

  • PDF

Characteristic Analysis and Implementation of 30kW Portable Test Equipment for Performance Evaluation in Energy Storage System (30kW급 ESS용 이동형 성능평가 시험장치의 구현 및 특성분석)

  • Park, Jea-Bum;Kim, Mi-Sung;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.6
    • /
    • pp.715-723
    • /
    • 2018
  • The energy storage system consists of batteries, power conditioning system and energy management system. If ESS is installed and operated in the field, SAT(Site Acceptance Test) of ESS is being essentially required for the safety and performance of ESS. Furthermore, in order to more accurately and reliably validate the performance of the ESS in advanced countries, it has been required to perform not only performance testing by H/W equipments but also performance verification by S/W tool. Therefore, this paper proposes the modeling of portable test equipment in order to evaluate the performance and reliability of ESS by using the PSCAD/EMTDC S/W. And also, the prototype of 30[kW] scaled portable test equipments is implemented based on the S/W modeling. From the results of various simulations and testings such as power quality, LVRT and anti-islanding tests, it is confirmed that 30[kW] scaled portable test equipment is useful for SAT of ESS, because the simulation results of PSCAD/EMTDC are identical to them of 30[kW] test equipment at the same test conditions.

A Study on Load Test of Bogie for High Speed Electrical Multiple Unit (고속용 전동차 대차의 하중시험에 관한 연구)

  • Kim W.K.;Yoon S.C.;Jun C.S.;Kwon S.T.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.34-38
    • /
    • 2005
  • This paper describes the result of load test of a bogie frame. The purpose of test is to evaluate the safety which bogie frame shall be considered fully sufficient rigidity so as to satisfy proper system function under maximum load. Bogie system consist of the bogie frame, suspensions, wheel-sets, a brake system and a transmission system. Among these component, the bogie frame is most significant component subjected to the vehicle and passenger loads. The evaluation method is used the JIS E 4207 specifications throughout the static load test. The test results have shown the bogie frame to be safe and stable under design load conditions.