• Title/Summary/Keyword: K&C test

Search Result 10,687, Processing Time 0.058 seconds

Effect of Volume Fraction on Mechanical and Fatigue Crack Growth Properties of SiC Particle Reinforced AL Alloy Composites (체적비가 $SiC_{p}$/AL 복합재료의 기계적 및 피로균열진전 특성에 미치는 영향)

  • Gwon, Jae-Do;An, Jeong-Ju;Mun, Yun-Bae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.4
    • /
    • pp.1301-1308
    • /
    • 1996
  • In order to save the energy and protect the environment, it were studied about ecomaterials with the developed countries as central figure. In the Metal Matrix Composites(MMCs), this trends appeared the development of the MMCs which had excellent mechanical properties in spite of the low volume fraction of reinforcement. Therefore, in this study, fatigue crack growth test, tensile and hardness test were conducted in order to investigate the mechanical and fatigue properties of 5 %, and 10 % $SiC_{p}$/Al composites. As the results, in the tensile and hardness test, tensile strength and hardness increased but fatigue crack growth rate decreased with $SiC_{p}$/Al volume fraction. And in the view of fatigue failured surface through the SEM, fatigue crack initiated around the SiC particle and in low $\Delta{K}$ regions, fatigue creck detoured the SiC particle but crack propagated through the SiC particle in the high $\DeltaK$ regions.

Static and Dynamic Characteristics of AC4C Aluminum Alloy (AC4C 알루미늄 합금의 정적 및 동적 특성)

  • Kwon, Y.G.;Ju, W.K.;Song, J.I.
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.220-225
    • /
    • 2007
  • The mechanical characteristics of AC4C Aluminum Casting Alloy were investigated by tensile test and impact test. Based on the tensile test' s result, we found that the yield strength of a high speed was about 10% higher than that of a low speed test and the maximum rupture strain mostly occurred in low speed tensile test. The impact energy of curved surface specimen was higher than that of plane surface specimen that can be measured in impact test.

  • PDF

Feasibility of utilizing oven-drying test to estimate the durability performance of concrete

  • Chen, How-Ji;Tang, Chao-Wei;Peng, Hsien-Sheng
    • Computers and Concrete
    • /
    • v.8 no.4
    • /
    • pp.389-399
    • /
    • 2011
  • The increasing concern for reinforced concrete structure durability has been justifying in many ways in the last few decades. However, there is no perfect durability test method till now. In this research an alternative method, which is based on the cumulative moisture loss percent of the concrete specimens after oven-drying, was proposed to estimate the durability performance of the concrete. Two temperatures were considered for the oven-drying tests: $100^{\circ}C$ and $200^{\circ}C$. Test results showed that oven-drying at $200^{\circ}C$ was obviously an unsuitable procedure to preserve the fragile microstructure of cement-based materials. By contrast, experimental results through oven-drying at $100^{\circ}C$ allowed estimating the moisture loss percent of cement-based materials in a more rational manner. Moreover, the magnitudes of the cumulative moisture loss percent obtained from oven-drying tests at $100^{\circ}C$ for 48 hours have good correlations with the data of other well-known methods, namely, electrical resistance test, water permeability test, and mercury intrusion porosimetry test. This investigation established that regarding the oven-drying test as one of the tests for evaluating the potential durability of concrete is considerably practicable.

The Size of the Cochran-Armitage Trend Test in 2 X C Contingency Tables: Two Multinomial Distribution Case

  • Kang, Seung-Ho;Ahn, Sun-Young
    • Communications for Statistical Applications and Methods
    • /
    • v.15 no.3
    • /
    • pp.403-409
    • /
    • 2008
  • In this paper we show that the peak of the type I error rate of the Oochran-Armitage trend test could be greater than the nominal level when $2\;{\times}\;C$ contingency tables obtained from two multinomial distributions are extremely unbalanced. This result justifies the use of the exact Cochran-Armitage trend test in extremely unbalanced $2\;{\times}\;C$ contingency tables.

A Study on the microstructure and Surge Characteristics of ZnO varistors for distribution Arrester (배전급 피뢰기용 ZnO 바리스터 소자의 미세구조 및 서지 특성에 관한 연구)

  • 김석수;조한구;박태곤;박춘현;정세영;김병규
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.2
    • /
    • pp.190-197
    • /
    • 2002
  • In this thesis, ZnO varistors with various formulation, such as A∼E, were fabricated according to ceramic fabrication method. The microstructure, electrical properties, and surge characteristics of ZnO varistors were investigated according to ZnO varistors with various formulation. In the microstructure, A∼E\`s ZnO varistor ceramics sintered at 1130$\^{C}$ was consisted of ZnO grain(ZnO), spinel phase (Zn$\_$2.33/Sb$\_$0.67/O$\_$4/), Bi-rich phase(Bi$_2$O$_3$) and intergranuler phase, wholly. Lightning impulse residual voltage of A, B, C and E\`s ZnO varistors suited standard characteristics, below 12kV at current of 5kA. On the contrary, D\`s ZnO varistor exhibited high residual voltage as high reference voltage. In the accelerated aging test, leakage current and watt loss of B, C and D\`s ZnO varistors increases abruptly with stress time under the first a.c. stress(115$\^{C}$/3.213kV/300h). Consequently, C varistor exhibited a thermal run away. On the contrary, leakage current and watt loss of A and C\`s ZnO varistors which show low initial leakage current exhibited constant characteristics. After high current impulse test, A\`s ZnO varistor has broken the side of varistor but impulse current flowed. On the contrary, E\`s ZnO Varistor exhibited good discharge characteristics which the appearance of varistor was not wrong such as puncture, flashover, creaking and other significant damage. After long duration impulse current test, E\`s ZnO varistor exhibited good discharge characteristics which the appearance of varistor was not wrong such as puncture, flashover, creaking and other significant damage. After high current impulse test and long duration impulse current test, E\`s ZnO varistor exhibited very good characteristics which variation rate of residual voltage is 1.4% before and after test.

Effects of Vitamin C on Airway Hyperresponsiveness in Heavy Smokers (흡연자의 기도 과민반응에 대한 비타민 C의 효과)

  • Lee, Sang-Gab;Kim, Ki-Ryang;Eim, Jeong-Ook;Kim, Heung-Up;Lee, Sang-Soo;Chung, Lee-Young;Kim, Hwi-Jong;Lee, Jong-Deog;Hwang, Young-Sil
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.4
    • /
    • pp.723-735
    • /
    • 1998
  • Background : Vitamin C has been reported to have a role in the decrease of airway hyperresponsiveness in animal models. This data is based on some metabolic actions of vitamin C, such as promotion of histamine degradation, producing more $PGE_2$ than $PGF_{2\alpha}$ in cyclooxygenase pathway, decrease of smooth muscle contraction, and acting as reducing agent of oxidant. It has been also known that heavy smokers have lower blood levels of vitamin C than nonsmokers and this deficiency in heavy smokers have been explained by several mechanisms, such as increased oxidation by oxidants and free radicals, increased biosynthesis of catecholamine and serotonin released by nicotine, and inadequate dietary intake. In this study, We attempted to assess effect of vitamin C on bronchial hyperresponsiveness in heavy smokers who have bronchial hyperresponsiveness and role of vitamin C on bronchial hyperresponsiveness. Method: To assess acute effect of vitamin C on airway hyperresponsiveness, blood sample for vitamin C level and spirometry, methacholine challenge test were done in 17 smokers and 8 nonsmokers, and one hour after oral administration of vitamin C 3 g, blood sample for vitamin C level and spirometry, methacholine challenge test were repeated. To assess chronic effect of vitamin C on airway hyperresponsiveness, after daily administration of vitamin C 1 g for one week in 17 smokers, blood sample for vitamin C level and spirometry, methacholine challenge test were done. To assess role of vitamin C, after oral administration of vitamin C 3 g plus indomethacin 100 mg in 12 of 15 smokers who were reactive to methacholine challenge test, spirometry and methacholine challenge test were done and after oral intake of indomethacin 100 mg in 12 smokers who were reactive to methacholine challenge test, spirometry and methacholine challenge test were repeated. Result: There were no significant differences in whole blood vitamin C levels between smokers($1.17{\pm}0.22$ mg/dL) and nonsmcikers($1.14{\pm}0.19$ mg/dL) (p>0.05). Fifteen of the 17 smokers(88.2%) were reactive to methacholine challenge test and 10 of the 15 smokers who were reactive to methacholine challenge test were less than 8 mg/dL in $PC_{20}FEV-2$, and 7 of the 8 nonsmokers(87.5%) were nonreactive to methacholine challenge test There were significant decrease in bronchial responsiveness after oral administration of vitamin C 3 g in 13 of the 15 smokers who were reactive to methacholine challenge test This significant decrease persisted with maintenance daily administration of 1 g for one week. $PC_{20}FEV-2$ were not correlated to vitamin C levels in smokers. After oral administration of indomethacin 100 mg, significant reduction of bronchial responsiveness that occured after oral administration of vitamin C 3 g in smokers were attenuated. Conclusion: Although there were no significant differences in whole blood vitamin C levels between smokers and nonsmokers. heavy smokers have significant increase in bronchial responsiveness than nonsmokers. This bronchial hyperresponsiveness of heavy smokers can be attenuated by vitamin C supplement. Disappearance of vitamin C effect by indomethacin supplement may suggest that vitamin C exert its effect via alteration of arachidonic acid metabolism.

  • PDF

Cyclic fatigue resistance tests of Nickel-Titanium rotary files using simulated canal and weight loading conditions

  • Cho, Ok-In;Versluis, Antheunis;Cheung, Gary S.P.;Ha, Jung-Hong;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.1
    • /
    • pp.31-35
    • /
    • 2013
  • Objectives: This study compared the cyclic fatigue resistance of nickel-titanium (NiTi) files obtained in a conventional test using a simulated canal with a newly developed method that allows the application of constant fatigue load conditions. Materials and Methods: ProFile and K3 files of #25/.06, #30/.06, and #40/.04 were selected. Two types of testing devices were built to test their fatigue performance. The first (conventional) device prescribed curvature inside a simulated canal (C-test), the second new device exerted a constant load (L-test) whilst allowing any resulting curvature. Ten new instruments of each size and brand were tested with each device. The files were rotated until fracture and the number of cycles to failure (NCF) was determined. The NCF were subjected to one-way ANOVA and Duncan's post-hoc test for each method. Spearman's rank correlation coefficient was computed to examine any association between methods. Results: Spearman's rank correlation coefficient (${\rho}$ = -0.905) showed a significant negative correlation between methods. Groups with significant difference after the L-test divided into 4 clusters, whilst the C-test gave just 2 clusters. From the L-test, considering the negative correlation of NCF, K3 gave a significantly lower fatigue resistance than ProFile as in the C-test. K3 #30/.06 showed a lower fatigue resistance than K3 #25/.06, which was not found by the C-test. Variation in fatigue test methodology resulted in different cyclic fatigue resistance rankings for various NiTi files. Conclusions: The new methodology standardized the load during fatigue testing, allowing determination fatigue behavior under constant load conditions.

Bioequivalence Test of Rifampicin Preparations(II) (리팜피신 제제의 생물학적 동등성시험(제2보))

  • Chang, Il-Hyo;Burm, Jin-Pil;Choi, Jun-Shik
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.2
    • /
    • pp.49-55
    • /
    • 1994
  • Bioequivalence test of commercially available rifampicin capsules was performed. Sixteen volunteers were divided into 2 groups and the reference and test drug were given orally (450 mg) by cross-over design. Statistical evaluation of AUC, $C_{max}\;and\;T_{max}$ involved an analysis of variance (ANOVA). The differences of mean value in AUC, $C_{max}\;and\;T_{max}$ between the reference and test drug were within 20% with reference drug. ANOVA showed no significant differences for ‘between group’, ‘drug’ and ‘period’, but not for ‘between subjects’. The power of test $(1-{\beta})\;of\;AUC\;and\;$C_{max}$ was larger than 0.8 and the confidence of bioavailability was $within\;{\pm}20%$. From these results, it was concluded that the two preparations were bioequivalent for AUC and $C_{max}$, but was not for $T_{max}$.

  • PDF

A New Multi-site Test for System-on-Chip Using Multi-site Star Test Architecture

  • Han, Dongkwan;Lee, Yong;Kang, Sungho
    • ETRI Journal
    • /
    • v.36 no.2
    • /
    • pp.293-300
    • /
    • 2014
  • As the system-on-chip (SoC) design becomes more complex, the test costs are increasing. One of the main obstacles of a test cost reduction is the limited number of test channels of the ATE while the number of pins in the design increases. To overcome this problem, a new test architecture using a channel sharing compliant with IEEE Standard 1149.1 and 1500 is proposed. It can significantly reduce the pin count for testing a SoC design. The test input data is transmitted using a test access mechanism composed of only input pins. A single test data output pin is used to measure the sink values. The experimental results show that the proposed architecture not only increases the number of sites to be tested simultaneously, but also reduces the test time. In addition, the yield loss owing to the proven contact problems can be reduced. Using the new architecture, it is possible to achieve a large test time and cost reduction for complex SoC designs with negligible design and test overheads.

Development of a Rice Circulating Concurrent-flow Dryer (I) - Performance Test of Pilot Scale Dryer - (순환식 병류형 곡물건조기 개발 (I) -시작기의 성능시험 -)

  • Han J.W.;Keum D.H.;Han J.G.;Kim H.;Hong S.J.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.4 s.117
    • /
    • pp.349-354
    • /
    • 2006
  • This study was performed to evaluate the performances for a concurrent flow rice dryer of pilot scale with devices for circulating rice. The pilot scale dryer with the capacity of 700 kg was developed to obtain design informations for the development of actual scale dryer of holding capacity of 10 tons. Three drying tests were conducted at two temperature levels of $100^{\circ}C\;and\;120^{\circ}C$, and two air flow rates levels of $28.5cmm/m^2\;and\;57.1cmm/m^2$. Drying conditions for Test-1, Test-2 and Test-3 were $100^{\circ}C\;-28.5cmm/m^2,\;120^{\circ}C-28.5cmm/m^2\;and\;120^{\circ}-57.1cmm/m^2}$ respectively. Drying rates were 0.73%(w.b./h) for Test-1, 0.90%(w.b./h) for Test-2 and 1.46%(w.b./h) for Test-3. The crack ratios of brown rice after drying ranged from 2.4% to 8.4%, and increased with the increase of drying rate and airflow rate. The energy consumptions were from 6,225 kJ/kg to 6,993 kJ/kg which was higher than that of conventional cross-flow rice circulating type dryer used in Korea. This results were due to the lower ambient air temperatures of $4.5^{\circ}C\;to\;13.4^{\circ}C$ during drying tests.