• 제목/요약/키워드: Junction field

Search Result 350, Processing Time 0.023 seconds

Real-Time HIL Simulation of the Discontinuous Conduction Mode in Voltage Source PWM Power Converters

  • Futo, Andras;Kokenyesi, Tamas;Varjasi, Istvan;Suto, Zoltan;Vajk, Istvan;Balogh, Attila;Balazs, Gergely Gyorgy
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1535-1544
    • /
    • 2017
  • Advances in FPGA technology have enabled fast real-time simulation of power converters, filters and loads. FPGA based HIL (Hardware-In-the-Loop) simulators have revolutionized control hardware and software development for power electronics. Common time step sizes in the order of 100ns are sufficient for simulating switching frequency current and voltage ripples. In order to keep the time step as small as possible, ideal switching function models are often used to simulate the phase legs. This often produces inferior results when simulating the discontinuous conduction mode (DCM) and disabled operational states. Therefore, the corresponding measurement and protection units cannot be tested properly. This paper describes a new solution for this problem utilizing a discrete-time PI controller. The PI controller simulates the proper DC and low frequency AC components of the phase leg voltage during disabled operation. It also retains the advantage of fast real-time execution of switch-based models when an accurate simulation of high frequency junction capacitor oscillations is not necessary.

Roles for α1-adrenoceptors during contractions by electrical field stimulation in mouse vas deferens

  • Alsufyani, Hadeel A.;Docherty, James R.
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.25 no.6
    • /
    • pp.525-532
    • /
    • 2021
  • We have investigated the relative roles of α1-adrenoceptors and purinoceptors in contractions to low and high frequency stimulation of the mouse vas deferens, in terms of the time course of responses. In separate experiments, isometric contractile responses were obtained to 10 pulses at 1 Hz and 40 pulses at 10 Hz. Responses to 1 Hz stimulation consisted of a series of discrete peaks. The α1A-adrenoceptor antagonist RS100329 (10-9M-10-7M) significantly reduced the response to the first pulse, the α1D-adrenoceptor antagonist BMY7378 (10-7M-10-6M) significantly reduced the response to the first two pulses, and the non-selective α1-adrenoceptor antagonist prazosin (10-8M) reduced the response to the first 4 pulses at 1 Hz. Responses to 10 Hz stimulation consisted of an early peak response and a maintained plateau response. RS100329 significantly reduced the peak response but did not significantly affect the plateau response. Prazosin, significantly reduced both the peak and plateau responses. The α1A-adrenoceptor antagonist RS17053 in high concentrations reduced mainly the plateau response leaving a clear early peak response. The plateau response of contraction was almost abolished by the purinoceptor antagonist suramin. These results suggest that there is a relatively minor early α1D-adrenoceptor and a larger early α1A-adrenoceptor component to stimulationevoked contractions of mouse vas deferens, but the major α1-adrenoceptor component is revealed by prazosin to be α1B-adrenoceptor mediated. α1B-Adrenoceptor activation probably facilitates contractions mediated by other α1-adrenoceptors and by purinoceptors. These results suggest that combined non-selective α1-adrenoceptor blockade, particularly α1B-adrenoceptor blockade, in addition to P2X1-purinoceptor blockade is useful in reducing male fertility.

Temperature reliability analysis according to the gate dielectric material of 4H-SiC UMOSFET (4H-SiC UMOSFET의 gate dielectric 물질에 따른 온도 신뢰성 분석)

  • Jung, Hang-San;Heo, Dong-Beom;Kim, Kwang-Su
    • Journal of IKEEE
    • /
    • v.25 no.1
    • /
    • pp.1-9
    • /
    • 2021
  • In this paper, a 4H-SiC UMOSFET was studied which is suitable for high voltage and high current applications. In general, SiO2 is a material most commonly used as a gate dielectric material in SiC MOSFETs. However, since the dielectric constant value is 2.5 times lower than 4H-SiC, it suffers a high electric field and has poor characteristics in the SiO2/SiC junction. Therefore, the static characteristics of a device with high-k material as a gate dielectric and a device with SiO2 were compared using TCAD simulation. The results show BV decreased, VTH decreased, gm increased, and Ron decreased. Especially when the temperature is 300K, the Ron of Al2O3 and HfO2 decreases by 66.29% and 69.49%. and at 600K, Ron decreases by 39.71% and 49.88%, respectively. Thus, Al2O3 and HfO2 are suitable as gate dielectric materials for high voltage SiC MOSFET.

Overviews on the Clinical Use of Stem Cells in Orthopaedics (근골격계에서 줄기세포를 이용한 재생치료의 개관)

  • Im, Gun-Il
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.6
    • /
    • pp.475-477
    • /
    • 2019
  • Stem cell research arose from the need to explore new therapeutic possibilities for intractable and lethal diseases. Although musculoskeletal disorders are basically nonlethal, their high prevalence and the relative ease of performing clinical trials have facilitated the clinical application of stem cells in this field. On the other hand, despite the plethora of in vitro and preclinical studies in stem cell research for regenerative medicine in the musculoskeletal system, few reliable clinical studies have been published. Stem cell therapy can be applied locally for bone, cartilage, and tendon regeneration. The candidate disease modalities in bone regeneration include large bone defects, nonunion of fractures, and osteonecrosis. Focal osteochondral defect and osteoarthritis are the current targets for cartilage regeneration. For tendon regeneration, bone-tendon junction problems, such as rotator cuff tears are hot topics in clinical research. To date, the literature supporting stem cell-based therapies comprises mostly case reports or case series.

A Practical Study on the New Revenue Estimate Model Of SSM (국내 대형슈퍼의 개량확률모델에 관한 실증연구)

  • Ahn, Sung-Woo;Lee, Sang-Youn;Kim, Pan-Jin;Youn, Myoung-Kil
    • Journal of Distribution Science
    • /
    • v.7 no.3
    • /
    • pp.5-24
    • /
    • 2009
  • In the retail management, store location has an important influence like business skills. The reason for failure to selecting location is that the market analysis model is not popular in business field. It gets worse in supermarket industry. Currently, store developers are relying on simple statistics and the sixth sense as market analysis techniques. lt proves that the market analysis model is not distributed well in the field. This market analysis model can apply to medium and small business market using an existing market analysis model, broad market model. And its study outcome can be theorized as a result. Converse's new retail model can be used as to analyze junction market. Pareto_Huff model can also be used to compute shopping probability. To do so, this study can be divided into walking distance market and driving distance market as a model market. Also it examines industry type such as SM and SSM. By taking consumer survey, condition of consumers to select store will be counted in shopping probability so that it improves the objectivity and reliability. Through this process, derived study outcome can be a new estimated revenue model for practical application of selecting store location in large and medium-sized supermarket.

  • PDF

A Study on Magnetoresistance Uniformity of NiFE/CoFe/AlO/CoFe/Ta TMR Devices Prepared by ICP Sputtering (ICP 스퍼터를 이용한 NiFe/CoFe/AlO/CoFe/Ta TMR 소자 제작에 있어서의 자기저항 균일성 연구)

  • 이영민;송오성
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.5
    • /
    • pp.189-195
    • /
    • 2001
  • We prepared TMR junctions of NiFe(170 )/CoFe(48 )/Al(13 )-O/CoFe(500 )/Ta(50 ) structure on 2.5$\times$2.5 $\textrm{cm}^2$ area Si/SiO$_2$ substrates in order to investigate the uniformity of magnetoresistance(MR) value using a ICP magnetron sputter. Each layer was deposited by the ICP magnetron sputter and tunnel barrier was formed by the plasma oxidation method. We measured MR ratio and resistance of TMR devices with four-terminal probe system by applying external magnetic field. Although we used ICP sputter which is known as superior to make uniform films, the standard variation of MR ratio was 2.72. The variation was not dependent on the TMR devices location of a substrate. We found that MR ratio and spin-flip field (H's) increased as the resistance increased, which may be caused by local interface irregularity of the insulating layer. The variation of resistance value was 64.19 and MR ratio was 2.72, respectively. Our results imply that to improve the insulating layer fabrication process including annealing process to lessen interface modulation in order to mass produce the TMR devices.

  • PDF

Dose Alterations at the Distal Surface by Tissue Inhomogeneity in High Energy Photon Beam (조직 불균질성에 의한 고에너지 광자선의 선량변화)

  • Kim, Young-Ai;Choi, Tae-Jin;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.13 no.3
    • /
    • pp.277-283
    • /
    • 1995
  • Purpose : This study was performed to measure dose alteration at the air-tissue interface resulting from rebuild-up to the loss of charged particle equilibrium in the tissues around the air-tissue interfaces. Materials and Methods : The 6 and 10-MV photon beam in dual energy linear accelerator were used to measure the surface dose at the air-tissue interface The polystyrene phantom sized $25{\times}25{\times}5\;cm^3$ and a water phantom sized $29{\times}29{\times}48\;cm^3$ which incorporates a parallel-plate ionization chamber in the distal side of air gap were used in this study. The treatment field sizes were $5{\times}5\;cm^2,\;10{\times}10\;cm^2\;and\;20{\times}20\;cm^2$. Air cavity thickness was variable from 10 mm to 50 mm. The observed-expected ratio (OER) was defined as the ratio of dose measured at the distal junction that is air-tissue interface to the dose measured at the same point in a homogeneous phantom. Results : In this experiment, the result of OER was close or slightly over than 1.0 for the large field size but much less (about 0.565) than 1.0 for the small field size in both photon energy. The factors to affect the dose distribution at the air-tissue interface were the field size, the thickness of air cavity. and the photon energy. Conclusion : Thus, the radiation oncologist should take into account dose reduction at the air-tissue interface when planning the head and neck cancer especially pharynx and laryngeal lesions, because the dose can be less nearly $29{\%}$ than predicted value.

  • PDF

About Short-stacking Effect of Illite-smectite Mixed Layers (일라이트-스멕타이트 혼합층광물의 단범위적층효과에 대한 고찰)

  • Kang, Il-Mo
    • Economic and Environmental Geology
    • /
    • v.45 no.2
    • /
    • pp.71-78
    • /
    • 2012
  • Illite-smectite mixed layers (I-S) occurring authigenically in diagenetic and hydrothermal environments reacts toward more illite-rich phases as temperature and potassium ion concentration increase. For that reason, I-S is often used as geothermometry and/or geochronometry at the field of hydrocarbons or ore minerals exploration. Generally, I-S shows X-ray powder diffraction (XRD) patterns of ultra-thin lamellar structures, which consist of restricted numbers of sillicate layers (normally, 5 ~ 15 layers) stacked in parallel to a-b planes. This ultra-thinness is known to decrease I-S expandability (%S) rather than theoretically expected one (short-stacking effect). We attempt here to quantify the short stacking effect of I-S using the difference of two types of expandability: one type is a maximum expandability ($%S_{Max}$) of infinite stacks of fundamental particles (physically inseparable smallest units), and the other type is an expandability of finite particle stacks normally measured using X-ray powder diffraction (XRD) ($%S_{XRD}$). Eleven I-S samples from the Geumseongsan volcanic complex, Uiseong, Gyeongbuk, have been analyzed for measuring $%S_{XRD}$ and average coherent scattering thickness (CST) after size separation under 1 ${\mu}m$. Average fundamental particle thickness ($N_f$) and $%S_{Max}$ have been determined from $%S_{XRD}$ and CST using inter-parameter relationships of I-S layer structures. The discrepancy between $%S_{Max}$ and $%S_{XRD}$ (${\Delta}%S$) suggests that the maximum short-stacking effect happens approximately at 20 $%S_{XRD}$, of which point represents I-S layer structures consisting of ca. average 3-layered fundamental particles ($N_f{\approx}3$). As a result of inferring the $%S_{XRD}$ range of each Reichweite using the $%S_{XRD}$ vs. $N_f$ diagram of Kang et al. (2002), we can confirms that the fundamental particle thickness is a determinant factor for I-S Reichweite, and also that the short-stacking effect shifts the $%S_{XRD}$ range of each Reichweite toward smaller $%S_{XRD}$ values than those that can be theoretically prospected using junction probability.

Clinical Application Analysis of 3D-CRT Methods Using Tomotherapy (토모테라피를 이용한 3차원 입체 조형 치료의 임상적 적용 분석)

  • Cho, Kang-Chul;Kim, Joo-Ho;Kim, Hun-Kyum;Ahn, Seung-Kwon;Lee, Sang-Kyoo;Yoon, Jong-Won;Cho, Jeong-Hee;Lee, Jong-Seok;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.327-335
    • /
    • 2013
  • This study investigates the case of clinical application for TomoDirect 3D-CRT(TD-3D) and TomoHelical 3D-CRT(TH-3D) with evaluating dose distribution for clinical application in each case. Treatment plans were created for 8 patients who had 3 dimensional conformal radiation therapy using TD-3D and TH-3D mode. Each patients were treated for sarcoma, CSI(craniospinal irradiaion), breast, brain, pancreas, spine metastasis, SVC syndrome and esophagus. DVH(dose volume histogram) and isodose curve were used for comparison of each treatment modality. TD-3D shows better dose distribution over the irradiation field without junction effect because TD-3D was not influenced by target length for sarcoma and CSI case. In breast case, dosimetric results of CTV, the average value of D 99%, D 95% were $49.2{\pm}0.4$ Gy, $49.9{\pm}0.4$ Gy and V 105%, V 110% were 0%, respectively. TH-3D with the dosimetric block decreased dose of normal organ in brain, pancreas, spine metastasis case. SCV syndrome also effectively decreased dose of normal organ by using dose block to the critical organs(spinal cord <38 Gy). TH-3D combined with other treatment modalities was possible to boost irradiation and was total dose was reduced to spinal cord in esophagus case(spinal cord <45 Gy, lung V 20 <20%). 3D-CRT using Tomotherapy could overcomes some dosimetric limitations, when we faced Conventional Linac based CRT and shows clinically proper dose distribution. In conclusion, 3D-CRT using Tomotherapy will be one of the effective 3D-CRT techniques.

INHIBITORY EFFECT OF Er:YAG LASER ON THE GROWTH OF STREPTOCOCCUS MUTANS (Er:YAG 레이저 조사가 Streptococcus mutans의 증식억제에 미치는 효과)

  • Song, Gwang-Chul;Lee, Chang-Seop;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.15-24
    • /
    • 2003
  • The purpose of this study is to investigate the sterilization effect of Er:YAG laser against the intraoral acid producing bacterium, S. mutans, by irradiating the culture solution containing S. mutans KCTC 3065 with Er:YAG laser having a $650{\mu}m$ diameter beam through the non-contact method. We obtained the following results after examining the temperature changes of the culture solution, numbers of bacterial colonies, and acid-producing ability and attaching ability on teeth by measuring the amount of extracellular polysaccharide produced by S. mutans. The number of bacterial colony was decreased in $10{\mu}l$ culture solution irradiated with laser in overall compared to the control solution. The number decreased as the irradiation intensity and pulse repetition rate were larger and as the exposure time was increased. However, it did not change significantly in $100{\mu}l$ culture solution compared to the control solution. Although the acid-producing ability of S. mutans was inhibited for a certain duration after laser irradiation in 10r1 bacterial culture solution, it did not change in $100{\mu}m$ solution compared with the control solution. The amount of extracellular polysaccharide synthesized by S. mutans was partially decreased through laser irradiation in $10{\mu}m$ culture solution but did not change in $100{\mu}m$ culture solution. Based on these findings, we concluded that Er:YAG laser has an sterilization effect on S. mutans in which we presume that the mechanism is through the heat effect rather than the mechanical effect from development of ultrasound.

  • PDF