• Title/Summary/Keyword: Junction Device

Search Result 425, Processing Time 0.028 seconds

Drying Stream and Hydrological Environment for Gwangjucheon (광주천의 건천화와 수문환경문제)

  • Yang, Hea-Kun
    • Journal of the Korean association of regional geographers
    • /
    • v.10 no.3
    • /
    • pp.568-578
    • /
    • 2004
  • This study is aimed at investigating floodgate characteristics and environmental issues in Gwangjucheon and examining possible problems of expanding river maintenance water being carried on in the context of river recovery works. In general, the obtained results show the following. The treatment water provisioned in the restoration project of the drying stream going through the water circulation device can pollute the land and groundwater in the Gwangjucheon Basin. Besides, although about $17,565m^3$/day of water is available in the upper ground, most of it go to the junction and exhausting directly to the waste water treatment or going into the groundwater. Because of the drying stream, the amount of water going to the ground is increased. Therefore, efficient land use along with regulations to protect cultivated land and ensure recovery works of city stream through the recovery of water circulation by constructing and expanding a special drainage system are of vital importance.

  • PDF

LED visible light communication and their application (LED 가시광 통신시스템과 그 응용)

  • Chung, Wan-Young;Kim, Jong-Jin;Kwon, Tae-Ha
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.226-229
    • /
    • 2010
  • LED(Light Emitting Diode) is an emitting device which energy is same to the bandgap of p-type and n-type semiconductor junction. Recently high brightness LED is used in fish-luring light and traffic signal light alternative of normal light bulb, and widely used in the area of display pannel. Moreover nowadays LED has been used as a back light of LCD display. Recently, visible light communication(VLC) using LED, that allow two-way serial data communication between LEDs over a distance of sveral centimeters or meters, has been widely studied in the area of digital information transmission along with illumination and display. In this paper, we present LED communication system and their applications.

  • PDF

Numerical Analysis on Cooling Characteristics of the Heat Sink for Amplifier (앰프용 히트싱크의 방열특성에 관한 해석적 연구)

  • Seo, Jae-Hyeong;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.947-951
    • /
    • 2015
  • The objective of this study is to numerically investigate the cooling characteristics of the heat sink as a cooling device for the amplifier. In order to analyze the heat transfer performances of the heat sink, the steady-state thermal model of the ANSYS software was used and analyzed with the fin thickness, fin pitch and fin number of the heat sink. As a result, the temperature at the junction of heat sink was decreased with the increase of fin thickness and fin number. In addition, the thermal resistances of the heat sinks were enhanced from $0.764^{\circ}C/W$ to $0.739^{\circ}C/W$ and $1.254^{\circ}C/W$ to $0.610^{\circ}C/W$, respectively, with the increase of the fin thickness from 1 mm to 3 mm and fin number from 9 to 20, respectively.

Research on Heat-Sink of 40Watt LED Lighting using Peltier Module (펠티어 소자를 이용한 40[W]급 LED 조명기구의 방열에 관한 연구)

  • Eo, Ik-Soo;Yang, Hae-Sool;Choi, Se-Ill;HwangBo, Seung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.4
    • /
    • pp.733-737
    • /
    • 2007
  • The object of this paper is to propose a method to solve resulting heat in using numerous modulized watt-class LEDs in MCPCB as lighting device. To use LED for lighting, the chip needs to have a large capacity, resulting in extra heat in P-N connection area. To solve this problem, a Pottier Module, heat-sink panel and a fan was installed to measure variations in the temperature. Additionally, temperature variation characteristics were observed according to the heat conductor panel connecting cooling module and heat-sink panel, insulator and thermal grease. As a result, the type and amount of heat-sink panel was the most important facto. The fan would effect the temperature by max. $18[^{\circ}C]$ while other materials affected the temperature by $2{\sim}3[^{\circ}C]$, showing significant difference.

  • PDF

Effect of Dentin Desensitizer on the Hypersensitivity of Teeth with Non-carious Cervical Lesions Subsequent to Ultrasonic Scaling (지각과민처치제가 초음파 스케일링 처리한 비우식성 치경부 병소가 있는 치아의 지각과민증에 주는 영향)

  • Cho, Jae-Hyung;Seok, Soohwang;Lee, Sang-Hyeok;Lim, Bum-Soon
    • Korean Journal of Dental Materials
    • /
    • v.43 no.1
    • /
    • pp.17-28
    • /
    • 2016
  • The aim of this study was to evaluate the changes in dentinal permeability after application of dentin desensitizer on exposed dentin immediately after ultrasonic scaling to teeth with non-carious cervical lesions. Thirty caries-free extracted molars were fixed to slide glasses after horizontally being sectioned at 5 mm below the cemento- enamel junction (CEJ). The prepared specimen was connected to a fluid flow measuring device (nano-Flow), and a V-shaped cavity was formed at the CEJ to imitate the non-carious cervical lesion. After no fluid leakage was confirmed in the connected system with specimen, tooth surface was treated ultrasonic cleaning with piezoelectric ultrasonic scalers until dentinal tubules were exposed. And 6 different desensitizers were applied on exposed dentin. Real-time measurements of dentinal fluid flow were performed during ultrasonic scaling and application of dentin desensitizer. To evaluate the occlusion of exposed dentinal tubules, tooth surface was examined by SEM. Following results were observed. After ultrasonic scaling, more dentinal tubules were exposed on the tooth with non-carious cervical lesions compared to tooth without lesions. The rate of fluid flow measured with nano-Flow system had correlation with the degree of dentin occlusion observed with SEM after application of desensitizers on exposed dentin. Desensitizers with glutaraldehyde and HEMA did not decrease the rate of fluid flow and did not show dentin occlusion. Desensitizers with oxalate showed the limited effects on the rate of fluid flow and dentinal tubule occlusion. Desensitizer with resin monomer showed the significant effect on the rate of fluid flow and dentin occlusion.

The Monitoring System with PV Module-level Fault Diagnosis Algorithm (태양전지모듈 고장 진단 알고리즘을 적용한 모니터링시스템)

  • Ko, Suk-Whan;So, Jung-Hun;Hwang, Hye-Mi;Ju, Young-Chul;Song, Hyung-June;Shin, Woo-Gyun;Kang, Gi-Hwan;Choi, Jung-Rae;Kang, In-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.3
    • /
    • pp.21-28
    • /
    • 2018
  • The objects of PV (Photovoltaic) monitoring system is to reduce the loss of system and operation and maintenance costs. In case of PV plants with configured of centralized inverter type, only 1 PV module might be caused a large loss in the PV plant. For this reason, the monitoring technology of PV module-level that find out the location of the fault module and reduce the system losses is interested. In this paper, a fault diagnosis algorithm are proposed using thermal and electrical characteristics of PV modules under failure. In addition, the monitoring system applied with proposed algorithm was constructed. The wireless sensor using LoRa chip was designed to be able to connect with IoT device in the future. The characteristics of PV module by shading is not failure but it is treated as a temporary failure. In the monitoring system, it is possible to diagnose whether or not failure of bypass diode inside the junction box. The fault diagnosis algorithm are developed on considering a situation such as communication error of wireless sensor and empirical performance evaluation are currently conducting.

Optimization of Optical Coupling Properties of Active-Passive Butt Joint Structure in InP-Based Ridge Waveguide (InP계 리지 도파로 구조에서 활성층-수동층 버트 조인트의 광결합 효율 최적화 연구)

  • Song, Yeon Su;Myeong, Gi-Hwan;Kim, In;Yu, Joon Sang;Ryu, Sang-Wan
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.4
    • /
    • pp.47-54
    • /
    • 2020
  • Integration of active and passive waveguides is an essential component of the photonic integrated circuit and its elements. Butt joint is one of the important technologies to accomplish it with significant advantages. However, it suffers from high optical loss at the butt joint junction and need of accurate process control to align both waveguides. In this study, we used beam propagation method to simulate an integrated device composed of a laser diode and spot size converter (SSC). Two SSCs with different mode properties were combined with laser waveguide and optical coupling efficiency was simulated. The SSC with larger near field mode showed lower coupling efficiency, however its far field pattern was narrower and more symmetric. Tapered passive waveguide was utilized for enhancing the coupling efficiency and tolerance of waveguide offset at the butt joint without degrading the far field pattern. With this technique, high optical coupling efficiency of 89.6% with narrow far field divergence angle of 16°×16° was obtained.

Electrical Characteristics Analysis Depending on the Portion of MPS Diode Fabricated Based on 4H-SiC in Schottky Region (4H-SiC 기반으로 제작된 MPS Diode의 Schottky 영역 비율에 따른 전기적 특성 분석)

  • Lee, Hyung-Jin;Kang, Ye-Hwan;Jung, Seung-Woo;Lee, Geon-Hee;Byun, Dong-Wook;Shin, Myeong-Choel;Yang, Chang-Heon;Koo, Sang-Mo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.3
    • /
    • pp.241-245
    • /
    • 2022
  • In this study, we measured and comparatively analyzed the characteristics of MPS (Merged Pin Schottky) diodes in 4H-SiC by changing the areal ratio between the Schottky and PN junction region. Increasing the temperature from 298 K to 473 K resulted in the threshold voltage shifting from 0.8 V to 0.5 V. A wider Schottky region indicates a lower on-resistance and a faster turn-on. The effective barrier height was smaller for a wider Schottky region. Additionally, the depletion layer became smaller under the influence of the reduced effective barrier height. The wider Schottky region resulted in the ideality factor being reduced from 1.37 to 1.01, which is closer to an ideal device. The leakage saturation current increased with the widening Schottky region, resulting in a 1.38 times to 2.09 times larger leakage current.

Modeling and Simulation Analysis of the Setup Reduction Method in Automobile Painting Process (자동차 도장 공정의 셋업 감소 방법 모델링 및 시뮬레이션 분석)

  • Han, Yong-Hee
    • Journal of the Korea Society for Simulation
    • /
    • v.18 no.3
    • /
    • pp.147-154
    • /
    • 2009
  • In this study we investigate the problem of reducing color change cost at painting operations in an automobile assembly plant. Changing control logic at conveyor junction points prior to the top coat line has been proposed and analyzed using the discrete event simulation model we developed using AutoMod. We also discussed the project which initiated this research as well as the details of painting operations. Simulation analysis showed that the grouping ratio increases from 1.8 to 2.5 if the proposed control logic change is applied to the plant. Contrary to other approaches such as using dedicated equipment for resequencing, our approach has the merit of less investment cost, no need for additional space consumption. We finally note that the grouping ratio can be further increased if our algorithms is implemented as well as CRS (Color Rescheduling Storage) is installed.

Effects of Organic Passivation Films on Properties of Polymer Solar Cells with P3HT:PC61BM Active Layers (유기 패시베이션 박막이 P3HT:PC61BM 활성층을 갖는 고분자 태양전지의 특성에 미치는 영향)

  • Lee, Sang Hee;Park, Byung Min;Cho, Yang Keun;Chang, Ho Jung;Jung, Jae Jin;Pyee, Jaeho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.4
    • /
    • pp.105-110
    • /
    • 2014
  • It is required to improve the efficiency and the reliability of the polymer solar cells (PSCs) as the energy saving optical device for the future application of the smart farm facilities. In this study, we fabricated the bulk hetero junction PSCs with organic passivation film layer for the reliability improvement of the devices. The effects of the passivation layer on the electrical properties of the PSCs were studied. The materials of passivation layer are composed of poly vinyl alcohol (PVA) and ammonium dichromate, and the passivation films were fabricated by the spin coating method on the P3HT:$PC_{61}BM$/LiF/Al substrate. The prepared structure of the device is the glass/ITO/PEDOT:PSS/P3HT:$PC_{61}BM$/LiF/Al/passivation layer. The performances of the PSCs with the organic passivation film showed better electrical properties compared with the PSCs without passivation layers. The power conversion efficiency (PCE) values of passivated PSCs decreased from 3.0 to 1.3% after air exposure for 140 hrs. In contrast, the PCE values for the devices without passivation decreased sharply from 3.5 to 0.1% under the same exposure condition.