• Title/Summary/Keyword: Jugular veins

Search Result 37, Processing Time 0.027 seconds

Laryngeal Transplantation in the Canine by End-to-end Anastomosis of the Recurrent Laryngeal Nerve Branches (반회신경분지의 단단문합에 의한 개의 후두이식)

  • 최홍식;김영호;조정일;김세헌;김상균;김광문;홍원표
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.9 no.1
    • /
    • pp.59-65
    • /
    • 1998
  • Instead of brilliant advancement of the organ transplantation in the medical fields, laryngeal transplantation still has couple of problems to be solved before trial on human. Among them functional restoration of the implanted larynx is the most important point. Recent advancement in animal model studies showed possibility of solving the main problem. Eighteen cases of canine laryngeal transplantation in mongrel dogs were done in this department. One cranial artery and two external jugular veins were connected. External and internal branches of the superior layngeal nerve and anterior and posterior branches of the recurrent laryngeal nerve were connected individually. Only two dogs have lived longer than 4 weeks(4weeks, and 10 1/2weeks) and they died unfortunately due to asphixia caused by obstruction of the cannula. Thirteen dogs only lived five days through 15 days. The main causes of the failure were obstruction of the connecting vein, pharyngocutaneous fistula and the wound infection. Although the result was not good enough to evaluate the functional restoration of the implanted larynx, the implanted larynges from the two dogs lived longer than minimum criteria of long term survival(4 weeks) were relatively good in shape at the time of autopsy. This program will be continued after renovation of the animal lab. facilities.

  • PDF

Study on the Changes in Enzyme and Insulin-like Growth Factor-1 Concentrations in Blood Serum and Growth Characteristics of Velvet Antler during the Antler Growth Period in Sika Deer (Cervus nippon)

  • Park, Jaehyun;Jeon, Byongtae;Kang, Sungki;Oh, Mirae;Kim, Myonghwa;Jang, Seyoung;Park, Pyojam;Kim, Sangwoo;Moon, Sangho
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.9
    • /
    • pp.1303-1308
    • /
    • 2015
  • This study was conducted to investigate changes in blood enzyme parameters and to evaluate the relationship between insulin-like growth factor-1 (IGF-1), antler growth and body weight during the antler growth of sika deer (Cervus nippon). Serum enzyme activity and IGF-1 concentrations were measured in blood samples collected from the jugular and femoral veins at regular intervals during the antler growth period. Blood samples were taken in the morning from fasted stags (n = 12) which were healthy and showed no clinical signs of disease. Alfalfa was available ad libitum and concentrates were given at 1% of body weight to all stags. The experimental diet was provided at 9 am with water available at all times. There were no significant differences in alkaline phosphatase, aspartate aminotransferase, and alanine aminotransferase during antler growth, but alkaline phosphatase concentrations increased with antler growth progression, and the highest alkaline phosphatase concentration was obtained 55 days after antler casting. Serum IGF-1 concentrations measured from blood samples taken from the jugular vein during antler growth, determined that levels of IGF-1 was associated with body weight and antler growth patterns. Serum IGF-1 concentrations were higher at the antler cutting date than other sampling dates. Antler length increased significantly during antler growth (p<0.001), and there was a similar trend to between right and left beams. Body weight increased with antler growth but was not significant. Consequently it appeared that serum alkaline phosphatase concentration was related to antler growth and both antler growth and body weight were associated positively with IGF-1 concentrations during antler growth.

Dilatation of Superior Ophthalmic Vein and Visual Disturbance by Central Venous Stenosis: A Case Mimicking Cavernous Sinus Dural Arteriovenous Fistula (상안정맥 확장 및 시력 저하를 보인 중심정맥협착: 해면경막 동정맥루로 오인된 증례 보고)

  • Young Hun Jeon;Kyung Sik Yi;Chi Hoon Choi;Yook Kim;Yeong Tae Park
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1619-1627
    • /
    • 2021
  • Central venous stenosis is a relatively common complication in hemodialysis patients; however, jugular venous reflux (JVR) and increased intracranial pressure are rare, and associated progressive visual disturbance was reported in only a few cases. Here, we report a case of JVR with visual disturbance and increased intracranial pressure. Notably, the MRI was accompanied by a dilatation of the superior ophthalmic vein, which was mistaken for a cavernous sinus dural arteriovenous fistula (CSdAVF). The patient had JVR on time-of-flight MR angiography (TOF-MRA) and severe stenosis of the left brachiocephalic vein on conventional angiography. After balloon angioplasty for central venous stenosis, he was discharged after improvement of his visual disturbance. Although JVR due to central venous stenosis and CSdAVF might show similar symptoms, treatment plans are different. Therefore, it is important to distinguish radiologically based on a thorough review of MRI and TOF-MRA and confirm the central venous stenosis on cerebral angiography for the accurate diagnosis.

Incidents and Complications of Permanent Venous Central Access Systems: A Series of 1,460 Cases

  • El Hammoumi, Massine;El Ouazni, Mohammed;Arsalane, Adil;El Oueriachi, Faycal;Mansouri, Hamid;Kabiri, El Hassane
    • Journal of Chest Surgery
    • /
    • v.47 no.2
    • /
    • pp.117-123
    • /
    • 2014
  • Background: Implanted venous access devices or permanent central venous access systems (PCVASs) are routinely used in oncologic patients. Complications can occur during the implantation or use of such devices. We describe such complications of the PCVAS and their management. Methods: Our retrospective study included 1,460 cases in which PCVAS was implanted in the 11 years between January 2002 and January 2013, including 810 women and 650 men with an average age of 45.2 years. We used polyurethane or silicone catheters. The site of insertion and the surgical or percutaneous procedure were selected on the basis of clinical data and disease information. The subclavian and cephalic veins were our most common sites of insertion. Results: About 1,100 cases (75%) underwent surgery by training surgeons and 360 patients by expert surgeons. Perioperative incidents occurred in 33% and 12% of these patients, respectively. Incidents (28%) included technical difficulties (n=64), a subcutaneous hematoma (n=37), pneumothoraces (n=15), and an intrapleural catheter (n=1). Complications in the short and medium term were present in 14.2% of the cases. Distortion and rupture of the catheter (n=5) were noted in the costoclavicular area (pinch-off syndrome). There were 5 cases of catheter migration into the jugular vein (n=1), superior vena cava (n=1), and heart cavities (n=3). No patient died of PCVAS insertion or complication. Conclusion: PCVAS complications should be diagnosed early and treated with probable removal of this material for preventing any life-threatening outcome associated with complicated PVCAS.

Central Vein Occlusion Secondary to Hemodialysis Catheterization in Chronic Renal Failure Patient -One Case Report- (만성 신부전 환자에서 혈액투석 도관에 의한 중심정맥 폐쇄증의 수술치험 -1례 보고-)

  • Lee, Seock-Yeol;Lee, Jun-Bock;Lee, Man-Bok;Youm, Wook;Lee, Kihl-Rho
    • Journal of Chest Surgery
    • /
    • v.31 no.6
    • /
    • pp.619-623
    • /
    • 1998
  • A 51-year-old male with chronic renal failure had marked swelling and tenderness of the right arm. Venography revealed central vein occlusion involving stenosis of right proximal subclavian vein, right internal jugular vein, and left distal innominate vein, and obstruction of right brachiocephalic vein. Multiple obstruction of these veins was thought to have resulted from repeated subclavian catheterization. Right subclavian-superior vena cava was bypassed with 10 mm Gore-tex vascular graft and then left subclavian vein with 8 mm Gore-tex vascular graft was bypassed to the 10 mm Gore-tex vascular graft. The results were excellent.

  • PDF

Quality Assessment of Longissimus and Semitendinosus Muscles from Beef Cattle Subjected to Non-penetrative and Penetrative Percussive Stunning Methods

  • Sazili, A.Q.;Norbaiyah, B.;Zulkifli, I.;Goh, Y.M.;Lotfi, M.;Small, A.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.26 no.5
    • /
    • pp.723-731
    • /
    • 2013
  • This study provides a comparative analysis of the effects of pre-slaughter penetrative and non-penetrative stunning and post-slaughter stunning on meat quality attributes in longissimus lumborum (LL) and semitendinosus (ST) muscles in heifers. Ten animals were assigned to each of four treatment groups: i) animals were subjected to conventional Halal slaughter (a clean incision through the structures at the front of the upper neck - the trachea, oesophagus, carotid arteries and jugular veins) and post-cut penetrating mechanical stun within 10 to 20 s of the neck cut (Unstunned; US); ii) high power non-penetrating mechanical stunning followed by the neck cut (HPNP); iii) low power non-penetrating mechanical stunning followed by the neck cut (LPNP); and iv) penetrative stunning using a captive bolt pistol followed by the neck cut (P). For each carcass, muscle samples were removed within 45 min of slaughter, portioned and analysed for pH, cooking loss, water holding capacity (WHC), tenderness (WBS), lipid oxidation (TBARS) and color, over a two week storage period. Stunning did not affect pH and cooking loss. Significant differences in water holding capacity, tenderness, lipid oxidation and color were present at different storage time points. HPNP stunning resulted in lower WHC and color values, particularly lightness ($L^*$), higher TBARS values and peak force values compared with those stunned using LPNP, P and US. These adverse effects on quality were mostly encountered in the ST muscle. In conclusion, the meat quality achieved using P, LPNP and US treatments was comparable, and no treatment stood out as considerably better than another.

Needle Entry Angle to Prevent Carotid Sheath Injury for Fluoroscopy-Guided Cervical Transforaminal Epidural Steroid Injection

  • Choi, Jaewoo;Ha, Doo Hoe;Kwon, Shinyoung;Jung, Youngsu;Yu, Junghoon;Kim, MinYoung;Min, Kyunghoon
    • Annals of Rehabilitation Medicine
    • /
    • v.42 no.6
    • /
    • pp.814-821
    • /
    • 2018
  • Objective To suggest rotation angles of fluoroscopy that can bypass the carotid sheath according to vertebral levels for cervical transforaminal epidural steroid injection (TFESI). Methods Patients who underwent cervical spine magnetic resonance imaging (MRI) from January 2009 to October 2017 were analyzed. In axial sections of cervical spine MRI, three angles to the vertical line (${\alpha}$, angle not to insult carotid sheath; ${\beta}$, angle for the conventional TFESI; ${\gamma}$, angle not to penetrate carotid artery) were measured. Results Alpha (${\alpha}$) angles tended to increase for upper cervical levels ($53.3^{\circ}$ in C6-7, $65.2^{\circ}$ in C5-6, $75.3^{\circ}$ in C4-5, $82.3^{\circ}$ in C3-4). Beta (${\beta}$) angles for conventional TFESI showed a constant value of $45^{\circ}$ to $47^{\circ}$ ($47.5^{\circ}$ in C6-7, $47.4^{\circ}$ in C5-6, $45.7^{\circ}$ in C4-5, $45.0^{\circ}$ in C3-4). Gamma (${\gamma}$) angles increased at higher cervical levels as did ${\alpha}$ angles ($25.2^{\circ}$ in C6-7, $33.6^{\circ}$ in C5-6, $43.0^{\circ}$ in C4-5, $56.2^{\circ}$ in C3-4). Conclusion The risk of causing injury by penetrating major vessels in the carotid sheath tends to increase at upper cervical levels. Therefore, prior to cervical TFESI, measuring the angle is necessary to avoid carotid vessels in the axial section of CT or MRI, thus contributing to a safer procedure.

Prediction of air inflow during central venous catheter insertion: experimental study (중심정맥관 삽입 시 발생하는 공기유입량의 예측: 실험연구)

  • Jung, Hyo Jae;Kim, Yang Weon;Park, Chang Min;Park, Chul Ho;Kang, Ji Hun;Yoon, Yoo Sang
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.6
    • /
    • pp.641-648
    • /
    • 2018
  • Objective: This study examined the incidence and amount of air inflow during central venous catheter (CVC) insertion. Methods: This study was an experimental study aimed at designing an apparatus to implement blood vessel and blood flow in the human body. A 1.5-m long core tube with a Teflon tube, suction rubber tube, and polyvinyl chloride tube were made. This core tube was assumed to be the blood vessel of the human body. Blood was replaced with a saline solution. The saline solution was placed higher than the core tube and flowed into the inside of the tube by gravity. The CVC was injected 15-cm deep into the core tube. The air was collected through a 3-way valve into the upper tube. The experiments were carried out by differentiating the pressure in the tube, CVC insertion step, and diameter of the end of the catheter. The experiment was repeated 10 times under the same conditions. Results: The amount of air decreased with increasing pressure applied to the tube. Air was not generated when the syringe needle was injected, and the amount of air increased with increasing size of the distal end catheter. Conclusion: To minimize the possibility of air embolism, it is necessary to close the distal end catheter at the earliest point as soon as possible.

Development of Biocompatible Vascular Graft -Endothelialization of Small Vascular Graft- (생체적합성 인조혈관의 개발 -혈관내피화 인조혈관-)

  • 김형묵;이윤신
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.373-380
    • /
    • 1996
  • Prevention of thromboembolism is the most important task in the development of bioconpatible small caliber artificial vascular graft. In normal vessels, vascular endothelial cells maintain homeosatsis by secreting numerous factors. The aim of this study is to develope a method which Improves biocompatibility of small caliver polyurethane graft using endothelial cell culture technique, and ev luate the efTectiveness of extracelluar matrix for endothelization which was produced by cultured fibroblast. Methods ; Multiporous polyurethane tube of 3 mm diameter, 0.3 mm thickness was manufactured for vascular graft. Three mongrel dogs were intubated and internal jugular veins removed. Extracelluar matrix produced by cultured flbrobast which was obtained from dog's internal jugular vein were coated to the polyurethane graft. Then, endothelial cells extracted from Jugular vein were cultured and fixed on the extracelluar matrix layer of vascular graft. Endothelial cell coated vascular grafts were implanted to the carotid arteries of experimental dogs as interposed autograft. Implanted grafts were removed after 3 and 6 weeks. As a control, PTFE graft was interposed on carotid artery. These experiments demonstrated that extracelluar matrix produced by fibroblast can afford a base for endothelial cell linings of polyurethane graft. Although thrombosis were developed on autografted en othelial cell coated graft, 33% opening was noticed, and showed less adhesion to adjacent tissue layer. These findings suggest that fiboblast produced extracelluar matrix which can be used for edothelial cell lining vascular graft, and by improving the cultured endothelial cell function, there will be a new modality for reducing thrombosis on small vascular graft.

  • PDF

Transarterial Coil Embolization in Two Maltese Dogs with Patent Ductus Arteriosus Using a Mini Cobra-tip Angiocatheter (말티스 견에서 시술된 미니코브라 카테터와 코일을 이용한 동맥관 개존증의 치료 2 증례)

  • Han, Dong-Hyun;An, Hyo-Jin;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.27 no.6
    • /
    • pp.740-745
    • /
    • 2010
  • Patent ductus arteiosus (PDA) is the persistent opening of ductus arterious located between pulmonary artery and descending aorta after birth. Although PDA can be occluded by surgical ligation, interventional closure of PDA using various devices is being rapidly replaced to surgical ligation, because of its non-invasive nature of treatment and minimal post-care after treatment. Main problem encountering in interventional treatment in toy breed dogs is vascular inaccessibility due to small size of artery. Although transvenous approach using jugular veins has been developed, this technique requires experienced skill to locate occlude devices into PDA and has high risk of accidental dislodgement of occluding devices (i.e. embolization coils or vascular plugs). Therefore, in this study, we developed a modified technique for coil embolization using mini-angiocatheter with trans-femoral approach in toy breed dogs (< 3.0 kg of body weight). With this modified method, we were successfully treated two toy breed (Maltese) dogs with the left to right shunted PDA.