• Title/Summary/Keyword: Journal evaluation

Search Result 68,570, Processing Time 0.105 seconds

Urinary Tract Infections in Febrile Infants under Three Months of Age (3개월 이하 영아기 열성 요로감염증에 대한 임상적 관찰)

  • Eun, Byung Wook;Chung, Yoo Mi;Kang, Hee Gyung;Ha, Il Soo;Cheong, Hae Il;Lee, Hoan Jong;Choi, Yong
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.3
    • /
    • pp.265-270
    • /
    • 2003
  • Purpose : To characterize the infants under 3 months of age with urinary tract infections(UTIs), and especially patients with bacteremia or meningitis Methods : Hospital records of all the infants under 3 months of age discharged from our hospital for 69 consecutive months with the diagnosis of initial episode of UTI were reviewed. UTI was defined when patients had fever with pyuria, and had urine culture results of ${\geq}10^5$ colony forming units/mL from a bag specimen. Patients with previously known urologic abnormality or immunodeficiency were excluded. Nosocomial infections were also excluded from the study. Results : The male:female ratio was 35 : 6. Of the urine cultures, 40(97.6%) yielded single pathogen, one yielded two pathogens. Escherichia coli was the predominant isolate from the urine. Five patients(12%) also had bacteremia. Pathogens isolated from the blood cultures were E. coli(4) and Enterococcus faecalis(1). No patient had culture-positive meningitis or cerebrospinal fluid pleocytosis. Clinical or laboratory findings between patients with and without bacteremia were not different significantly. The rate of vesicoureteral reflux(VUR) was 44%. The sensitivity of ultrasound for detection of VUR was 38%; specificity was 50%. Conclusion : Clinical and laboratory data were not helpful for identifying patients with bacteremia at the time of presentation. Consequently, blood cultures need to be obtained from all febrile infants under 3 months of age with UTIs. A large-scale study including the indication of lumbar puncture for infants with a febrile UTI and study of evaluation and treatment of infants under 3 months of age with UTIs are required.

The usefulness of skin test in evaluation of immunity to varicella (수두에 대한 면역력 평가에 있어서 피부 시험의 유용성)

  • Kim, Ji-Young;Lee, Hye Jeen;Kim, Me Jin;Kim, Young Ho;Jung, Ji A;Yang, Seung;Hwang, Il Tae;Lee, Hae Ran
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.4
    • /
    • pp.377-382
    • /
    • 2008
  • Purpose : The aim of this study is to assess the usefulness of skin test by an inactivated, 1/50 diluted solution of attenuated varicella vaccine in evaluating the immune status to varicella. Methods : Total 41 subjects (22 males, 19 females, aged 1-32 years) were enrolled from July to August, 2005. Past medical history including varicella infection, varicella vaccination were investigated through questionnaires. The skin test solution was prepared from solution of attenuated varicella vaccine(Oka strain) which was inactivated by exposure to room temperature for 10 days and diluted at 1/50 with normal saline. Skin test was done by injecting 0.1 mL of the solution intradermally into the volar surface of the right forearm and sterile normal saline was used as a control on the left forearm. Positive reaction was defined when the transverse diameter of the induration was 5 mm or more. Serum varicella zoster virus specific IgG antibody test by ELISA (enzyme-linked immunosorbent assay) was done. Results : In adults, the sensitivity of the varicella zoster virus skin test compared to ELISA was 94.7% and the positive predictive value was 100%. In children, both the positive predictive value and specificity were 100% but the sensitivity and the negative predictive value were 50% and 30.7% respectively. Children showed smaller skin test reactivity compared to adults. Conclusion : The varicella zoster virus skin test using inactivated, 1/50 diluted solution of attenuated varicella vaccine was proved as one of the useful tools for evaluating the immunity and susceptibility of the varicella zoster virus.

Evaluation of the radiopacity and cytotoxicity of resinous root canal sealers (레진계 근관충전실러의 방사선 불투과성 및 세포 독성에 대한 평가)

  • Kim, Chang-Kyu;Ryu, Hyun-Wook;Chang, Hoon-Sang;Lee, Byung-Do;Min, Kyung-San;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.5
    • /
    • pp.419-425
    • /
    • 2007
  • The aim of this study was to evaluate the radiopacity and cytotoxicity of three resin-based (AH 26, EZ fill and AD Seal), a zinc oxide-eugenol-based (ZOB Seal), and a calcium hydroxide-based (Sealapex) root canal sealers. Specimens, 10 mm in diameter and 1 mm in thickness, were radiographed simultaneously with an aluminum step wedge using occlusal films, according to ISO 6876/2001 standards. Radiographs were digitized, and the radiopacity of sealers was compared to the different thicknesses of the aluminum step wedge, using the Scion image software. Using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay, the cytotoxicity of each material was determined in immortalized human periodontal ligament (IPDL) cells. The results demonstrated that EZ fill was the most radiopaque sealer, while Sealapex was the least radiopaque (p < 0.05). AH 26, AD Seal and ZOB Seal presented intermediate radiopacity values. All the materials evaluated, except for Sealapex, presented the minimum radiopacity required by ISO standards. The cell viabilities of resin-based root canal sealers were statistically higher than that of other type of root canal sealers through the all experimental time. Further, EZ fill showed statistically lower cell viability in 24 and 48 hours compared to AD Seal and in 72 hours compared to all other resin-based root canal sealers. However, there was no correlation between the radiopacity and cytotoxicity of three resin-based root canals sealers (p > 0.05). These results indicate that resin-based root canal sealer is more biocompatible and has advantage in terms of radiopacity.

Comparison of Turfgrass Density, Uniformity and Tiller Characteristics in Mixtures of Overseeded Warm-Season and Cool-Season Grasses (덧파종한 난지형 및 한지형 혼합 식생 잔디밭에서 잔디밀도, 균일도 및 분얼경 특성 비교)

  • Kim, Kyoung-Nam
    • Weed & Turfgrass Science
    • /
    • v.6 no.1
    • /
    • pp.67-76
    • /
    • 2017
  • The study was initiated to evaluate the effects of overseeding warm-season grass (Zoysia japonica Steud.) with cool-season grasses (CSG) on turfgrass density, uniformity and tiller appearance and to determine turfgrass species and seeding rate applicable for a practical use. Treatments were comprised of Kentucky bluegrass (KB, Poa pratensis L.), perennial ryegrass (PR, Lolium perenne L.), tall fescue (TF, Festuca arundinacea Schreb.) and their mixtures. Overall turfgrass density and uniformity were much better with the overseeded treatments over the control. In early stage after overseeding, the greater the PR in treatments, the greater the turfgrass density and uniformity. But the higher the KB, the lower the density and uniformity. From the middle-stage evaluation, however, we observed the opposite results as compared with early-stage findings. Accordingly, the KB was highest in turfgrass density and uniformity, while the PR lowest. In regards of mixtures, both turfgrass density and uniformity were better with increased KB and decreased PR in overseeding rates. As for a medium-quality mixtures of Korean lawngrass with CSG, it would be the best choice to apply with KB at $50g\;m^{-2}$ and equal combination of KB, PR and TF by 1/3 in mixing at $75g\;m^{-2}$ in terms of sustainable density and uniformity.

A Study of Cleaning Technology for Zirconium Scrap Recycling in the Nuclear Industry (원자력산업에서 지르코늄 스크랩 재활용을 위한 세정기술에 관한 연구)

  • Lee, Ji-Eun;Cho, Nam-Chan;An, Chang-Mo;Noh, Jae-Soo;Moon, Jong-Han
    • Clean Technology
    • /
    • v.19 no.3
    • /
    • pp.264-271
    • /
    • 2013
  • In this study, we optimized the removal condition of contaminants attached on the scrap surface to recycle the scrap generated from the Zr alloy tube manufacturing process back to the nuclear grade. The main contaminant is remnant of watersoluble cooling lubricant that is used in the pilgering manufacture during the tube production, and it is assumed to be compressed and carbonized on the surface of tube. Zirlo alloy tube of ${\phi}9.50mm$, which has high occurrence frequency of scrap, was selected as the object to be cleaned, and cleaning abilities of reagents were evaluated by measuring the characteristics of contaminants remained and by analyzing the surface of the tube after cleaning process. For evaluation of each cleaning agent, we selected two types of sodium hydroxide series and three types of potassium hydroxide series. Furthermore, to confirm dependence on tempe-rature and ultrasonic intensities, cleaning at the room temperature, $40^{\circ}C$, and $60^{\circ}C$ was conducted, and results showed that higher the cleaning temperature and higher the ultrasonic intensity, better the cleaning effect. As a result of the bare-eye inspection, while the use of sodium hydroxide provided satisfactory condition on the tube surface, the use of potassium hydroxide series provided satisfactory condition on the tube surface only when the ultrasonic intensity was over 120 W. In the cleaning effect analysis using the gravimetric method, cleaning efficiency of sodium hydroxide series was as high as 97.6% ($60^{\circ}C$, 120 W), but since the tube surface condition was poor after the use of potassium hydroxide, the gravimetric method was not appropriate. In the analytical result of surface contaminants on the tube surface, C, O, Ca, and Zr were detected, and mainly C and O dominated the proportion of contaminants. It was also found that the degree of cleaning on the tube affected the componential ratio of C and O; if the degree of cleaning is high, or if cleaning is well-conducted, the proportion of C is decreased, and the proportion of O is increased. Based on these results, optimal cleaning for application in the industry can be expected by categorizing cleaning process into three steps of Alkali cleaning, Rinsing, and Drying and by adjusting cleaning parameters in each step.

A Study on Formulation of Surfactant-free Aqueous Cleaning agents and Evaluation of Their Physical Properties and Cleaning Ability (계면활성제 무첨가 세정제의 배합 및 물성/세정성 평가 연구)

  • Lee, Jae Ryoung;Yoon, Hee Keun;Lee, Min Jae;Bae, Jae Heum;Bae, Soo Jeong;Lee, Ho Yeoul;Kim, Jong Hee
    • Clean Technology
    • /
    • v.19 no.3
    • /
    • pp.219-225
    • /
    • 2013
  • Environment-friendly and surfactant-free aqueous cleaning agents have been developed in order to solve various problems generated by surfactants in the aqueous cleaning agents. Aqueous surfactant-free cleaning agents, S-1 and S-2 have been formulated with water-soluble solvents such as propylene glycol and propylene glycol ether on their main components and with some additives. These solvents were chosen because of their good solubility in water and excellent solubility of fluxes which are major contaminants of printed circuit board in the electronic industry. Physical properties of the formulated and the imported cleaning agents were measured to predict their cleaning performance, and their cleaning abilities of flux and solder contaminants were evaluated under the various ultrasonic frequencies by a gravimetric method. The measurement results show that the physical properties of cleaning agent V are generally similar with those of formulated cleaning agents S-1 and S-2. Both the cleaning agent V and the formulated cleaning agents S-1 and S-2 showed similar trends that their pH decrease in the beginning and then increases later on with the increase of their dilution in water. It is considered that the wetting indices of the cleaning agents calculated with experimental values do not not have any influence on their cleaning ability. In ultrasonic cleaning tests under three ultrasonic frequencies of 28, 45, and 100 kHz, their best performances of cleaning solder and flux were obtained at 45 kHz and 28 kHz, respectively, and the cleaning performance of the formulated cleaning agents S-1 and S-2 was better than that of the cleaning agent V. However, in the case of the recommended diluted concentration of 25 wt% cleaning solution, the cleaning performance of the cleaner V for solder and flux was better in the initial stage of cleaning compared to the formulated cleaners. And it may be concluded that the formulated cleaning agents S-1 and S-2 can be applied to cleaning of solder and flux in the industry, based on the experimental results in this study.

Effects of CSV Activities on Purchasing Intention : on the Perspectives of Value Chain (공유가치창출(CSV)활동이 구매의도에 미치는 영향 : 가치사슬 관점)

  • Weon, Jong-Ha;Jung, Dae-Hyu
    • Management & Information Systems Review
    • /
    • v.36 no.4
    • /
    • pp.1-19
    • /
    • 2017
  • These days, the concept of creating shared value is drawn keen attentions to. This interest comes out of the expectation that Creating Shared Value(CSV) can offer an answer to some social issues by creating societal and economic values on the top of the achievements that existing Corporate Social Responsibility(CSR) has made. However, it is difficult to make a clear distinction between the achievements that the activities of CSR and CSV have made. In this regard, developing a methodology to make an actual proof analysis on the accomplishments of CSV and to verify customer's awareness of and attitude towards the CSV is necessarily required. A company needs to gain a competitive advantage in the marketplace as well as resolve a social issue by innovating value chain. The research has verified the cause and effect relationship between the CSV from the point of view of value chain and the purchase intention aroused by its economic, societal and cultural values through the company image and credibility with actual proof analysis and come up with following results. First, a societal and cultural value resulted in giving positive impact on a company's image, which implies that CSV activities can be the thin end of the wedge through which customers have a good image of the company involved in CSV. Second, a societal value makes a positive influence on the credibility of a company. In this regard, CSV should be recognized not just as a thing that generates a cost, but a way to win-win as well as future development. Third and last, the research results show that both company image and credibility influence on purchase intention. Considering that CSV generates a positive evaluation on a company that will ultimately cause continuous profit-making, the company's ultimate goal of activities, it should be approached from the perspective of making a mid-and-long term strategy.

  • PDF

Serial Survey on Group A beta-Hemolytic Streptococcal Carrier Rate and Serotyping in Elementary School Children in 1996~1998 (3년간(1996~1998) 초등학생의 A군 연쇄구균 보균율과 혈청학적 분류에 관한 연구)

  • Kim, Ji-Hyun;Kim, Ju-Ye;Kang, Hyeon-Ho;Cha, Sung-Ho;Lee, Young-Hee
    • Pediatric Infection and Vaccine
    • /
    • v.7 no.1
    • /
    • pp.143-151
    • /
    • 2000
  • Purpose : The accuracy of bacteriologic diagnosis of beta-hemolytic streptococcal pharyngotonsillitis depends on the degree of carrier rate in that area where the throat swabs are obtained and the evaluation of serological T typing as an epidemiologic marker is important to understand epidemiology of streptococcal infection. The purpose of this study is to know the carrier rates of group A streptococcus in normal children form four different areas and to find out the epidemiologic characteristic in distribution of the serotypes for 3 years. Method : Throat swabs were obtained from the tonsillar fossa of normal school children in four different areas(Uljin, Seoul, Osan, Kunsan) from March to May 1996, in Uljin in April 1997, and in Uljin in April 1998. The samples were plated on a 5% sheep blood agar plate and incubated overnight at $37^{\circ}C$ before examination for the presence of beta-hemolytic colonies. All isolated beta-hemolytic streptococcus were grouped and serotyped by T agglutination. Results : The carrier rate of beta-hemolytic streptococci and group A streptococci in 1996 were 27.6%, 18.6% at Uljin; 16.4%, 2.7% at Seoul; 33.0%, 26.0% at Osan; 20.0%, 12.3% at Kunsan, respectively. Among 1,192 normal school children from 4 different areas, we obtained 179 strains of group A streptococci. Fifty two percent of the strains were typable by T agglutination in 1996. Common T-type in 1996 were NT, T1, T3, T2 at Uljin; T12, T25 at Seoul; NT, T6, T28 at Osan; T25, T4, NT, T5 at Kunsan, in decreasing order, respectively. At Uljin, T1, T3, T25 accounted for 69% of strains in 1996, T1, T12, T25 accounted for 70% in 1997, and T12, T4 accounted for 88% in 1998. Conclusion : Higher carrier rates were found in Uljin and Osan, where there are a lower population density with scanty of medical facilities compared with another areas. We supposed that low carrier rates is likely to be related to antibiotic abuse or some epidemiologic factor. The periodic and seasonal serotyping analysis is important in monitoring and understanding the epidemiologic patterns of group A streptococci.

  • PDF

Efficiency Study of 2D Diode Array Detector for IMRT Quality Assurance (2D 어레이 다이오드 검출기를 통한 IMRT 계산선량의 정확성 평가 및 효용성 연구)

  • Kim, Tae-Ho;Oh, Seung-Jong;Kim, Min-Joo;Jung, Won-Gyun;Chung, Jin-Beom;Kim, Jae-Sung;Kim, Si-Yong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.61-66
    • /
    • 2011
  • In this study, we evaluated the effect of grid size on dose calculation accuracy using 2 head & neck and 2 prostate IMRT cases and based on this study's findings, we also evaluated the efficiency of a 2D diode array detector for IMRT quality assurance. Dose distributions of four IMRT plan data were calculated at four calculation grid sizes (1.25, 2.5, 5, and 10 mm) and the calculated dose distributions were compared with measured dose distributions using 2D diode array detector. Although there was no obvious difference in pass rate of gamma analysis with 3 mm/3% acceptance criteria for the others except 10 mm grid size, we found that the pass rates of 2.5, 5 and 10 mm grid size were decreased 5%, 20% and 31.53% respectively according to the application of the fine acceptance criteria, 3 mm/3%, 2 mm/2% and 1 mm/1%. The calculation time were about 11.5 min, 4.77 min, 2.95 min, and 11.5 min at 1.25, 2.5, 5, and 10 mm, respectively and as the grid size increased to double, the calculation time decreased about one-half. The grid size effect was observed more clearly in the high gradient area than the low gradient area. In conclusion, 2.5 mm grid size is considered acceptable for most IMRT plans but at least in the high gradient area, 1.25 mm grid size is required to accurately predict the dose distribution. These results are exactly same as the precious studies' results and theory. So we confirmed that 2D array diode detector was suitable for the IMRT QA.

Comparison of Intensity Modulated Radiation Therapy Dose Calculations with a PBC and AAA Algorithms in the Lung Cancer (폐암의 세기조절방사선치료에서 PBC 알고리즘과 AAA 알고리즘의 비교연구)

  • Oh, Se-An;Kang, Min-Kyu;Yea, Ji-Woon;Kim, Sung-Hoon;Kim, Ki-Hwan;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.48-53
    • /
    • 2012
  • The pencil beam convolution (PBC) algorithms in radiation treatment planning system have been widely used to calculate the radiation dose. A new photon dose calculation algorithm, referred to as the anisotropic analytical algorithm (AAA), was released for use by the Varian medical system. The aim of this paper was to investigate the difference in dose calculation between the AAA and PBC algorithm using the intensity modulated radiation therapy (IMRT) plan for lung cancer cases that were inhomogeneous in the low density. We quantitatively analyzed the differences in dose using the eclipse planning system (Varian Medical System, Palo Alto, CA) and I'mRT matirxx (IBA, Schwarzenbruck, Germany) equipment to compare the gamma evaluation. 11 patients with lung cancer at various sites were used in this study. We also used the TLD-100 (LiF) to measure the differences in dose between the calculated dose and measured dose in the Alderson Rando phantom. The maximum, mean, minimum dose for the normal tissue did not change significantly. But the volume of the PTV covered by the 95% isodose curve was decreased by 6% in the lung due to the difference in the algorithms. The difference dose between the calculated dose by the PBC algorithms and AAA algorithms and the measured dose with TLD-100 (LiF) in the Alderson Rando phantom was -4.6% and -2.7% respectively. Based on the results of this study, the treatment plan calculated using the AAA algorithms is more accurate in lung sites with a low density when compared to the treatment plan calculated using the PBC algorithms.