• Title/Summary/Keyword: Joint transfer

Search Result 350, Processing Time 0.027 seconds

A Study on Development of Arc Sensor for Arc Welding Robot Using Consumable Electrode (소모성 전극을 사용하는 아크용접 로봇을 위한 아크센서 개발에 관한 연구)

  • 이승영;문형순;나석주;장영주;안병규
    • Journal of Welding and Joining
    • /
    • v.11 no.3
    • /
    • pp.22-33
    • /
    • 1993
  • Arc sensor is indispensable to arc welding robot systems for compensating the joint misalignment such as mismatch of the workpiece, ill-conditioned positioner and thermal deformation during welding. Furthermore, the amount of these mismatches cannot be preivously expected, and changes from time to time. There are many kinds of seam trackers for correcting the welding path of the robot, where non-contact type sensors arc prevalently used in arc welding robot systems. In this study, an arc sensor was developed for GMA and FCA welding robot system. Since the arc sensor uses the arc characteristics during welding, the operating principle of the arc sensor must be adjusted according to the welding condition. Especially in GMA welding with the $CO_{2}$ shielding gas, the welding arc is not stable because of the short circuit and non-axial globular transfer mode of the molten droplet. In this study, the 2nd order least square curve fitting algorithm was adopted and the applicability of this algorithm was investigated for robot welding systems. For easy usage of the arc sensor, the operating parameters for arc sensor were limited to eight which can be easily determined by the operator.

  • PDF

Optimization of arc brazing process parameters for exhaust system parts using box-behnken design of experiment

  • Kim, Yong;Park, Pyeong-Won;Park, Ki-Young;Ryu, Jin-Chul
    • Journal of Welding and Joining
    • /
    • v.33 no.2
    • /
    • pp.23-31
    • /
    • 2015
  • Stainless steel is used in automobile muffler and exhaust systems. However, in comparison with other steels it has a high thermal expansion rate and low thermal conductivity, and undergoes excessive thermal deformation after welding. To address this problem, we evaluated the use of arc brazing in place of welding for the processing of an exhaust system, and investigated the parameters that affect the joint characteristics. Muffler parts STS439 and hot-dipped Al coated steel were used as test specimens, and CuAl brazing wire was used as the filler metal for the cold metal transfer (CMT) welding machine, which is a low heat input arc welder. In addition, a Box-Behnken design of experiment was used, which is a response surface methodology. The main process parameters (current, speed, and torch angle) were used to determine the appropriate welding quality and the mechanical properties of the brazing part was evaluated at the optimal welding condition. The optimal processing condition for arc brazing was 135A current, 51cm/min speed and $74^{\circ}$ torch angle. The process was applied to an actual exhaust system muffler and the prototype was validated by thermal fatigue, thermal shock, and endurance limit tests.

The Analysis of Welding Deformation in Large Welded Structure by Using Local & Global Model (Local & Global 모델을 이용한 용접구조물 변형 해석에 관한 연구)

  • Jang Kyoung-Bok;Cho Si-Hoon;Jang Tae-Won
    • Journal of Welding and Joining
    • /
    • v.22 no.6
    • /
    • pp.25-29
    • /
    • 2004
  • Some industrial steel structures are composed by components linked by several welding joints to constitute an assembly. The main interest of assembly simulation is to evaluate the global distortion of welded structure. The general method, thermo-elasto-plastic analysis, leads to excessive model size and computation time. In this study, a simplified method called "Local and Global approach" was developed to break down this limit and to provide a accurate solution for distortion. Local and global approach is composed of 3 steps; 1) Local simulation of each welding joint on a dedicated mesh (usually very fine due to high thermal gradients), taking into account for the non linearity of the material properties and the moving heat source. 2) Transfer to the global model of the effects of the welding joints by projection of the plastic strain tensors. 3) Elastic simulation to determine final distortions in global model. The welding deformation test for mock-up structure was performed to verify this approach. The predicted welding distortion by this approach had a good agreement with experiment results.

Clinical Application of OXYREX Hollow Fiber Membrane Oxygenator (국산 막형 산화기 (OXYREX)의 체외순환 임상 성적 - 개심수술 40례 적용 -)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.23 no.6
    • /
    • pp.1049-1056
    • /
    • 1990
  • The OXYREX hollow fiber membrane oxygenator developed by joint work of KIST and Green Cross Medical company has been evaluated by experimental investigation and clinical application, In this oxygenator gas exchanges occur through small pores of 0.1pm size which are distributed on 70% of surface of polypropylene hollow fiber. The Oxyrex membrane oxygenator consists of 36 thousand hollow fibers and it has 3.3m2 of gas exchange surface. The Oxyrex membrane oxygenator has unique blood flow path: blood enters the oxygenator passes between the hollow fibers and exits through outlet ports, that provides low transmembrane pressure drop. In the animal experiment and in vitro investigations of Oxyrex oxygenator, it showed low transmembrane pressure difference, effective heat exchanger performance, stable gas transfer function and less blood trauma. The Oxyrex oxygenator been used from March, 1990, to October, 1990, in 40 patients undergoing open heart operations. In the clinical applications of Oxyrex, adequate oxygenation[PaO2, 283$\pm$70mmHg] and carbon dioxide removal[PaCO2, 27\ulcorner6mmHg]were maintained under the condition of FiO2: below 0.6, Hct; 25%, perfusion flow; 2.4 L/min, gas flow: 2.1 L/min. During maximum 365 minutes of cardiopulmonary bypass[CPB] time period, the Oxyrex oxygenator maintained stable condition of PaO2, PaCO2 respectively and it also kept low plasma hemoglobin level. The complement proteins C3 and CH50 were not significantly changed pre to post CPB. There were no complications related to the oxygenator during and after the CPB.

  • PDF

A Study of Hygroscopic Moisture Diffusion Analysis in Multimaterial System (이종 소재 접합체의 흡습 질량 확산 해석)

  • Kim, Yong-Yun
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.2
    • /
    • pp.11-15
    • /
    • 2011
  • Heat transfer equation is first reviewed and then governing equation of moisture diffusion. Analogy scheme is applied to analysis the moisture absorption problem of polymers. It make possible to numerically analyze the diffusion problem for single medium by using commercial finite element code if it is under the isothermal loading condition. It is extended to special multimaterial system by introducing pressure ratio function, whose moisture characteristics of materials are proportional to temperature only. The weight changes of silicon-nonconductive-polymer joint model due to moisture absorption is measured and been very close to the numerical results as for single media with boundary condition with zero concentration, but yields numerical errors as for multisystem media.

TORANOMON HILLS - Super High-Rise Building on Urban Highway -

  • Hitomi, Yasuyoshi;Takahashi, Hiroshi;Karasaki, Hidenori
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.3
    • /
    • pp.167-171
    • /
    • 2014
  • TORANOMON HILLS is the main building of a large-scale re-development project located in the center of Tokyo. This high-rise building has a height of 247 m and 52 floors above ground, 5 floors below ground, and $62m{\times}80m$ in plan. It is used as hotel, residential facilities, offices, shops and conference facilities. The super structure is mainly a rigid steel frame with response-control devices, using concrete-filled steel tube columns. The underground section is a mixed structure composed of steel, steel-reinforced concrete and reinforced concrete framings. The piled-raft foundation type is used. The remarkable feature of this high-rise building is that the motorway runs through the basements of the building, which makes it stand just above the motorway. This condition is an important factor of the building design. The plan shape is designed to fit along the curve of the motorway. Special columns at the corners are required to avoid placing columns in the motorway. This special column is a single inclined column in the lower floors that branches into two columns in the mid-floors to suit the column location in the upper floors. The cast steel joint is used for the branching point of each special column to securely transfer the stress.

Experimental Study on the Inelastic Behavior of Single-layer Latticed Dome (단층 래티스 돔의 비탄성 거동에 대한 실험연구)

  • Kim, Jong-Soo;Kim, Sang-Dae;Kim, Myeong-Han;Oh, Myoung-Ho;Shin, Chang-Hoon
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.165-170
    • /
    • 2008
  • This study discusses the inelastic behavior of single-layer latticed dome, composed of tubular truss member and newly proposed joint sections, through loading test on the scale-down structure. The loading test was performed under displacement control conditions, using loading transfer system for the same value of point loads on all joints. Maximum applied load was nearly 1.6 times of the design load, and inelastic buckling occured beyond compressive yeilding in some members. The displacement of structure was maimtained upto the limit of oil jack. The behavior of latticed dome from the loading test was analyzed on the view of structural design practice.

  • PDF

A Study on the Civil Liability of Telemedicine and Some Legislative Proposals (원격의료의 법률관계 및 법제개선방안)

  • Jeong, Yong-Yeub
    • The Korean Society of Law and Medicine
    • /
    • v.7 no.1
    • /
    • pp.323-386
    • /
    • 2006
  • A combination of information technology and medical care has given rise to a new type of medicine, i.e., telemedicine. Broadly defined, telemedicine is the transfer of electronic medical data from one location to another. Both at home and abroad, telemedicine has come to success in establishing appropriate equipment and solutions for such non-conventional medicine. Sooner or later, telemedicine is believed to find itself as one of the universal treatments. In order to facilitate the full-fledged development of telemedicine, a number of legal and institutional problems have to be settled. In Korea, the Medical Act was amended to include such provisions as telemedicine, electronic medical records, electronic prescriptions, etc. and the Act came into force on March 31, 2002. Telemedicine is in common with the conventional medicine in that a physician treats a patient. However, telemedicine is basically differentiated in the followings: - The offer and acceptance of treatment and medication are usually made on-line; - Telemedicine is inherently dangerous because a physician cannot meet face-to-face with a patient; and - Joint and several liability is borne by all the physicians involved in a telemedical consultation. As a result, telemedicine is vulnerable in nature to medical malpractice. Accordingly, there must be some new theories and arguments in the formation of contract and torts. The discussion on the civil liability covers the above-mentioned issues, and would give an insight or guidelines in the concerted operation of provisions with respect to telemedicine. This study delves into the civil liability of physicians involved in telemedical consultations and treatments based upon the conventional malpractice theory.

  • PDF

General Concepts and Theories for the development and Integration of an advanced Unified Approach to Structure borne Noise Analysis (자동차의 구조 전달 소음 해석에 사용되는 현존 기법의 통합 관련 일반 개념 및 이론)

  • 이상엽;이세재
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1993.04a
    • /
    • pp.93-100
    • /
    • 1993
  • With increasing technology, requirement to car noise and related dynamics are getting competitive keypoint. Unfortunately, vibro - acoustic behavior of a car is nowadays only possible after development of prototypes. But, obviously, in the Area of Research, many of Industrials, Universities and research centers try to codevelop the design tools to predict the vibro-acoustic behaviors. At this stage, it is more realistic to represent the existing technologies in order for the engineer to get their own know-how to design and to Integrate existing techniques, to setup their test facility, and to develope some tools with which they can successfully predict noise levels of car in the design phase. Moreover, most of the theories which will be represented in this paper can be used in the design phase. At any way, finding the cause of trouble shooting is more urgent than the design of a car to the test engineer. In this paper, transfer path analysis, noise source identification, and the key test method of modal analysis is introduced. Later, if I get the opportunity to present in KSNVE, the approach method of modal analysis is introduced. Later, if I get the opportunity to present in KSNVE, the approach method of finding characteristics of joint and welding part will be introduced. Most parts of this paper was quoted from the papers of LMS.

  • PDF

Thumb Reconstruction with Rib Transplantation (늑골을 이용한 무지 결손의 재건)

  • Chung, Duke-Whan;Pyo, Na-Sil
    • Archives of Reconstructive Microsurgery
    • /
    • v.9 no.1
    • /
    • pp.56-61
    • /
    • 2000
  • Recommendable reconstructive surgery in the patient with thumb amputation through base of the first metacarpal bone is pollicization. Some patients who do not agree with harvest sound finger as a new thumb, we can consider other options as toe transplantation or osteoplastic thumb reconstruction for creating thumb. Toe transplantation to the thumb is effective procedure in the amputation of distal to metacarpal shaft, it is rarely indicated in the cases of proximal to base of the first metacarpal bone. We performed three cases of modified osteoplastic thumb reconstruction with free vascularized rib that combined with scapular free flap or radial forearm flap. The length of transplanted rib ranged from 7~11cm, the donor vessels are posterior intercostal artery and vein which anastomosed to radial artery. The grafted rib wrapped with additional free flap for creating new thumb. Result of that procedure was not much encouraging, aesthetic appearance and mobility of thumb were not so satisfactory but reconstructed thumb gave improvement of the hand function without sacrificing toe or other digit. That gave reasonable stability for powerful side pinch and three pod pinch and opposable thumb with normal carpo-metacarpal joint motion that can give much function to the thumb absent hand. In spite of those disadvantages, thumb reconstruction with rib transfer can be useful for patients who do not want to lose another part of the body for creating thumb in basal amputation of the thumb metacarpal.