• Title/Summary/Keyword: Joint transfer

Search Result 350, Processing Time 0.024 seconds

Relaying Protocols and Delay Analysis for Buffer-aided Wireless Powered Cooperative Communication Networks

  • Zhan, Jun;Tang, Xiaohu;Chen, Qingchun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.8
    • /
    • pp.3542-3566
    • /
    • 2018
  • In this paper, we investigate a buffer-aided wireless powered cooperative communication network (WPCCN), in which the source and relay harvest the energy from a dedicated power beacon via wireless energy transfer, then the source transmits the data to the destination through the relay. Both the source and relay are equipped with an energy buffer to store the harvested energy in the energy transfer stage. In addition, the relay is equipped with a data buffer and can temporarily store the received information. Considering the buffer-aided WPCCN, we propose two buffer-aided relaying protocols, which named as the buffer-aided harvest-then-transmit (HtT) protocol and the buffer-aided joint mode selection and power allocation (JMSPA) protocol, respectively. For the buffer-aided HtT protocol, the time-averaged achievable rate is obtained in closed form. For the buffer-aided JMSPA protocol, the optimal adaptive mode selection scheme and power allocation scheme, which jointly maximize the time-averaged throughput of system, are obtained by employing the Lyapunov optimization theory. Furthermore, we drive the theoretical bounds on the time-averaged achievable rate and time-averaged delay, then present the throughput-delay tradeoff achieved by the joint JMSPA protocol. Simulation results validate the throughput performance gain of the proposed buffer-aided relaying protocols and verify the theoretical analysis.

Load Transfer Capacity for the Planar Joints between Existing Slab Retrofitted with Carbon Fiber Plate and New Slab (탄소판으로 보강된 기존 슬래브와 신규 슬래브 접합부의 횡방향 하중전달 능력)

  • Kim, Seung Hun;You, Young Chan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.2
    • /
    • pp.117-124
    • /
    • 2007
  • An experimental research has been performed to evaluate the load transfer capacity for the planar joints between existing and new slab in an apartment remodelling constructions expecially for enlarging the interior space. Post-installed dowel bars were used as a joint connector. The existing slabs were obtained from the existing apartment housing which will be demolished, and were retrofitted with carbon fiber plate. Test results showed that the planar joints with post-installed dowel bars behaved in full composite modes until ultimate capacity of test specimens, so sufficient ultimate and serviceability performance are confirmed.

The characteristics of R&D Network in Zhongguancun Cluster (중관촌(中關村) 클러스터 연구개발 네트워크의 특성)

  • Jun, Zhan;Lee, Chul Woo
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.550-569
    • /
    • 2012
  • This paper studies the R&D network of the Zhongguancun Cluster, the most representative innovative cluster of the high-tech industry in China at present. For this study, Zhongguancun Cluster was the first high-tech cluster to have been created in China, the current Zhongguancun Cluster has played a leading role in the development of the high-tech industry in China. In addition, the Zhongguancun Cluster has at helped elevate China as a key region in terms of research development in relation to the high-tech industry. In particular, companies evaluate the research development network culture of Zhongguancun cluster positively and this increases their tendency to approach the research development network with an open mind. The main contents in research development network are as follows; (1) joint or consigned research development and technology transfer in the case of research development network between companies, (2) joint or consigned research development, human resource support and employment, technical advice and consultant and technology transfer in the case of industrial-educational relationships (3) joint or consigned research development, technical advice and consultant and technology transfer in the case of industrial-research relationships, (4) financial support and participation in joint research development project held by government in the case of industrial and governmental relationships (5) financing for research development, utilization of research human resources, purchase of research development and use of research development equipment for mediators. The main difficulties in creating a research development network are 'lack of mutual trust', 'financial problems of companies' and 'lack of information'. Especially, the main key obstacles for the most important research development network between industry and government in the case of the Zhongguancun Cluster are 'complicated and strict procedures. Therefore, more accurate and detailed understanding of the conditions and the following institutional measures from government are required for research development among companies.

  • PDF

A Study on Dynamic Behaviour of Single Cylinder Reciprocating Compressor by Joint Simulation of Flexible Multi-body Dynamics and Electromagnetic Circuit (유연체 동역학 모델과 전력전자 회로의 연동해석을 통한 단기통 왕복 압축기 거동해석에 관한 연구)

  • Sung, Won-Suk;Hwang, Won-Gul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.1
    • /
    • pp.28-38
    • /
    • 2012
  • The characteristics of vibration and noise of a compressor used for electric appliances have significant influence on the quality of the products. For improvement on the quality of electric appliances, investigations for understanding the dynamic behaviour of the compressor are essential. Since Virtual Lab for the dynamics model and MAXWELL for the electromagnetics model are separate software programs with no interface, the joint simulation of the models could not be performed. This study suggests a way to develop the compressor model capable of the joint simulation with MATLAB/SIMULINK linking a flexible multi-body dynamics model, a torque model, and an electricity control model. The compressor model is found to be able to perform I/O data transfer among the sub-models and joint simulation. The simulation results of the flexible body and rigid body dynamics models were compared to check availability of the joint simulation system. In addition, the simulated vibration and driving torque of the compressor mechanisms were compared with measurements. Through the simulations, the influence of springs and LDT on the dynamic behaviour of the compressor was examined. This study examines the influence of the dynamic behaviour of the compressor mechanisms through joint simulation of the flexible multi-body dynamics model and electromagnetic circuit allows analysis.

Split Transfer of Extensor Digitorum Longus of the Second Toe for Elongation of EHB after Modified Jones' Procedure (변형된 Jones 술식 후에 발생한 단무지 신전건의 연장을 치료하기 위한 제2 장족지 신전건의 분리 이전술)

  • Kim, Jung-Rae;Lee, Woo-Chun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.3
    • /
    • pp.183-186
    • /
    • 2011
  • Extensor hallucis brevis (EHB) is only extensor of the first metatarsophalangeal (MTP) joint after modified Jones procedure. Therefore preserving the normal insertion of the EHB has been emphasized during that procedure. We experienced a case of EHB rupture after modified Jones procedure and had satisfied surgical outcome by partial transfer of extensor digitorum longus (EDL) of second toe.

Integral Bridge Using H-pile (H-말뚝을 이용한 일체식교대 교량)

  • 정경자;김성환;유성근
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.241-248
    • /
    • 1999
  • The existing bridge with deck joint has many problems during construction and maintenance. To overcome these difficulties, an integral bridge, which is defined as the practice of constructing bridges without deck joints, is proposed in this study. A test bridge with 3 spans of PC beam was selected to verify the function of the bridge and is under construction. Characteristics of integral bridge are followings: $\circled1$ Flexible H-piles under the abutment are installed to accommodate thermal movements of the superstructures of bridge. $\circled2$ PC beam of the superstructure and the abutment are integrated. $\circled3$ The existing approach and relief slabs are applied to minimize the stress transfer occurred from the bridge deck to the pavement. $\circled4$ A cyclic control joint is installed between approach and relief slabs to absorb the thermal movement. $\circled5$ It is used a dual direction bearing which is cheaper than single direction bearing and has a good workability as well. It is also installed a shear block on the top of pier coping to protect the lateral movement caused by temperature change and earthquake.

  • PDF

Key-hole Technique in Treatment of A-C Dislocation - Preliminary Report - (Key-hole 술식을 이용한 급성 견봉쇄골관절 탈구의 치료-예비보고-)

  • Choi Chang-Hyuk;Kwun Koing-Woo;Kim Shin-Kun;Lee Sang-Wook;Yun Young-Jun
    • Clinics in Shoulder and Elbow
    • /
    • v.2 no.1
    • /
    • pp.8-13
    • /
    • 1999
  • The results of the operative treatment of the Grade III acromioclavicular joint injury is defined by the durability of the reduced joint and free of exertional pain. Several surgical techniques have been applied to reduce and stabilize the joints effectively. Resection of clavicular lateral end and subacromial decompression also could be applied to prevent post-operative arthritic change. Biomechanical studies reveals the role of clavicular elevation and rotation to achieve more than 90 degrees of elevation. It also serves as a attachment site of deltoid and trapezius muscle. The stability and mobility of the both acromioclavicular and coracoclavicular joint are important to get full functional recovery. We modified the methods of coracoacromial ligament transfer described by Weaver-Dunn and by Shoji et a!. to pre­vent pullout of the transferred ligament and to get more improved functional results. Main technical point was harvesting full thickness bone block and fix it through the key-hole to reduce pull out angle.

  • PDF

Surgical Treatment for Painful Instability of the Second Metatarsophalangeal Joint - 1 Case Report - (동통을 동반한 제2 중족 족지 관절 불안정성의 치료경험 - 1예 보고 -)

  • Suh, Dong-Hyun;Park, Yong-Wook;Kim, Do-Young;Lee, Sang-Soo;Seo, Young-Jin;Park, Hyun-Chul;Kang, Seung-Wan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.2
    • /
    • pp.204-207
    • /
    • 2004
  • An unstable second metatarsophalangeal joint may produce pain in the forefoot. Plication of stretched lateral ligament and capsule and transfer of the extensor digitorum brevis under the transverse intermetatarsal ligament performed as the primary procedure to stabilize this painful joint. But the pain was not subsided and the proximal phalanx was resubluxated. So, we osteotomized the second metatarsal to restore a normal alignment of the second toe. Then the symptom was subsided. We report a case of painful instability of the metatarsophalangeal joint of the second toe.

  • PDF

The Treatment of the Acromioclavicular Dislocation using the Modified Neviaser Method (변형된 Neviaser 술식을 이용한 견봉쇄골관절 탈구의 치료)

  • Han Su Il;Kim Joon Seok;Lee Young Kuk
    • Clinics in Shoulder and Elbow
    • /
    • v.4 no.1
    • /
    • pp.24-29
    • /
    • 2001
  • Purpose: To describe a technique of the modified Neviaser method and to evaluate the clinical outcome of the technique in the treatment of the complete acromioclavicular joint dislocation, Materials and Method: We evaluated 20 patients who were treated by a modified Neviaser method from June 1996 to January 1999, They were followed up for a minimum of two years. The operative technique includes fixation of the acromioclavicular joint, repair of coracoclavicular ligament and transfer of the anterolateral band of coracoacromial ligament. Results: The 20 patients were evaluated clinically using Kang's criteria. The satisfactory results obtained in 85%. The mean coracoclavicular interval ratio was decreased from 2.22 preoperatively to 1.07 postoperatively. At the time of two year follow-up, the mean ratio was 1.20. There was no definite complication such as re-dislocation of the joint. Conclusion: In above type 3 acromioclavicular dislocation, the modified Neviaser method provided the advantage of strong and stable fixation with a low complication rate. Therefore, it is thought to be one of the useful operative technique.

  • PDF

A Study on the Evaluation System of Jointed Concrete Pavement (콘크리트포장 줄눈부의 평가에 관한 기법연구)

  • Park, Je-Seon;Lee, Joo-Hyung;Hong, Chang-Woo;Lee, Jung-Ho
    • Journal of Industrial Technology
    • /
    • v.19
    • /
    • pp.245-251
    • /
    • 1999
  • The joint in the concrete pavement provides a control against transverse or longitudinal cracking at slab, which may be caused by temperature or moisture variation during or after hydration. Without control of cracking, random crack may cause more serious distresses and result in structural or functional failure of pavement system. Sometimes, joint itself, purposed to control crack, may cause a distresses in joint due to its inherent weakness in structural integrity. Thus, the load transfer capacity in joint is very important for serviceability and durability. The purpose of this dissertation was to develop an evaluation system at joints of jointed concrete pavement using finite element analysis was performed using ILLI-SLAB program with a selected variables which might affect fairly to on the performance of transverse joints. The most significant variables were selected from precise analysis. It was concluded that the variables which most significantly affect to pavement deflections are the modulus of subgrade reaction(K) and the modulus of dowel/concrete interaction(G), and limiting criteria on the performance of joints at JCP at 300pci, 500,000 lb/in. respectively.

  • PDF