Load Transfer Capacity for the Planar Joints between Existing Slab Retrofitted with Carbon Fiber Plate and New Slab

탄소판으로 보강된 기존 슬래브와 신규 슬래브 접합부의 횡방향 하중전달 능력

  • Received : 2006.08.24
  • Published : 2007.03.30

Abstract

An experimental research has been performed to evaluate the load transfer capacity for the planar joints between existing and new slab in an apartment remodelling constructions expecially for enlarging the interior space. Post-installed dowel bars were used as a joint connector. The existing slabs were obtained from the existing apartment housing which will be demolished, and were retrofitted with carbon fiber plate. Test results showed that the planar joints with post-installed dowel bars behaved in full composite modes until ultimate capacity of test specimens, so sufficient ultimate and serviceability performance are confirmed.

본 연구에서 내부 공간을 확장시키기 위한 평면확장형 공동주택 리모델링에 있어서 기존 슬래브와 신규 슬래브 접합부의 횡방향 하중 전달 성능을 평가하기 위한 실험을 수행하였다. 슬래브의 접합연결재로 후 매립 Dowel 철근을 사용하였다. 기존 슬래브는 철거 예정인 기존 아파트로부터 채취하였으며, 휨성능을 향상시키기 위하여 탄소판(CFRP)으로 보강하였다. 실험결과로부터 후 매립 Dowel 철근으로 접합된 접합부 실험체가 최종파괴 시까지 완전합성거동을 하는 것을 확인하였으며, 충분한 극한성능 및 사용성능을 확보하고 있음을 알 수 있었다.

Keywords

References

  1. 임호진, 이도범, 이병찬, "국내 리모델링 현황", 콘크리트학회지 제15권 4호, 2003. 7, pp. 13-18.
  2. 대한건축학회, "건축구조설계기준", 2005.
  3. ACI committee 318, "Building Code Requirements for Structural Concrete(ACI 318-05)", American Concrete Institute, 2005.