편측하퇴의지의 절단 길이에 따른 보행 특성 비교 (Comparisons of the gait characteristics depended on amputation length of the Unilateral Trans-Tibial Prostheses)

  • 유재응;정석
    • The Journal of Korean Physical Therapy
    • /
    • 제15권3호
    • /
    • pp.166-172
    • /
    • 2003
  • The aim of this study is to present the basic reference data of age and specific gait parameters for comparisons of the gait characteristics depended on amputation length of the Unilateral Trans-Tibial Prostheses. The basic gait parameters were extracted from 10 Adult, and 20 below knee(B/K) patients, 50 to 60 years of age using VICON 512 Motion Analyzer. The results were as follows; 1. The mean Cadence of the above knee(A/K) patients and below knee(B/K) patients were $87.77{\pm}8.64$ steps/min, to $99.84{\pm}11.14$ steps/min.(p<0.05) 2. The mean Walking Speed of the above knee(A/K) patients and below knee(B/K) patients were $0.84{\pm}0.15$ m/s, to $0.96{\pm}0.25$ m/s.(p>0.05) 3. The mean Stride Length of the above knee(A/K) patients and below knee(B/K) patients were $1.14{\pm}0.14\;m$, to $1.14{\pm}0.22m$.(p>0.05) 4. The mean maximal angles of joint on the hip flexion motion for different above knee(A/K) patients and below knee(B/K) patients were $34.75{\pm}10.18_{\circ}$, to $32.32{\pm}6.34_{\circ}$.(p>0.05) 5. The mean maximal angles of joint on the knee flexion motion for different above knee(A/K) patients and below knee(B/K) patients were $66.97{\pm}15.08_{\circ}$, to $52.65{\pm}9.21_{\circ}$. (p<0.05) 6. The mean maximal angles of joint on the ankle dorsi-flexion motion for different above knee(A/K) patients and below knee(B/K) patients were $14.41{\pm}4.82_{\circ}$, to $10.04{\pm}3.49_{\circ}$.(p>0.05) 7. The mean maximal angles of joint on the ankle plantar-flexion motion for different above knee(A/K) patients and below knee(B/K) patients were $5.77{\pm}3.17_{\circ}$, to $2.75{\pm}4.49_{\circ}$.(p>0.05)

  • PDF

편측대퇴의지와 편측하퇴의지의 보행특성 비교 (Comparisons of the gait characteristics depended on Unilateral Trans-Femoral or Trans-Tibial Prostheses)

  • 안창식;정석
    • The Journal of Korean Physical Therapy
    • /
    • 제16권2호
    • /
    • pp.108-115
    • /
    • 2004
  • The aim of this study is to present the basic reference data of age and specipic gait parameters for comparisons of the gait characteristics depended on Unilateral Trans-Femoral or Trans-Tibial Prostheses. The basic gait parameters were extracted from 10 Adult, 10 above knee(A/K) patients and 10 below knee(B/K) patients, 50 to 60 years of age using VICON 512 Motion Analyzer. The results were as follows; 1) The mean Cadence of the above knee(A/K) patients and below knee(B/K) patients were $87.77{\pm}8.64$ steps/min, to $99.84{\pm}11.14$ steps/min.(p<0.05) 2) The mean Walking Speed of the above knee(A/K) patients and below knee(B/K) patients were $0.84{\pm}0.15$ m/s, to $0.96{\pm}0.25$ m/s.(p>0.05) 3) The mean Stride Length of the above knee(A/K) patients and below knee(B/K) patients were $1.14{\pm}0.14$ m, to $1.14{\pm}0.22$m.(p>0.05) 4) The mean maximal angles of joint on the hip flexion motion for different above knee(A/K) patients and below knee(B/K) patients were $34.75{\pm}10.18_{\circ}$, to $32.32{\pm}6.34_{\circ}$ .(p>0.05) 5) The mean maximal angles of joint on the knee flexion motion for different above knee(A/K) patients and below knee(B/K) patients were $66.97{\pm}15.08_{\circ}$, to $52.65{\pm}9.21_{\circ}$ .(p<0.05) 6) The mean maximal angles of joint on the ankle dorsiflexion motion for different above knee(A/K) patients and below knee(B/K) patients were $14.41{\pm}4.82_{\circ}$, to $10.04{\pm}3.49_{\circ}$ .(p>0.05) 7) The mean maximal angles of joint on the ankle plantarflexion motion for different above knee(A/K) patients and below knee(B/K) patients were $5.77{\pm}3.17_{\circ}$, to $2.75{\pm}4.49_{\circ}$ .(p>0.05)

  • PDF

발목관절 조절각도가 절단환자의 보행에 미치는 영향 (Influence on amputee gait by the ankle joint alignment)

  • 김영호;양길태;임송학;장윤희;문무성
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.369-372
    • /
    • 1997
  • Socket pressure distributions with gait analyses of a transfemoral and a transtibial prostheses were measured in order to assess an optimal socket fitting and unction. Ankle joint was aligned by the neutral and the dorsi/plantar flexed positions. Compared to dorsi and plantar flexed positions of ankle joint, cadence and walking speed increased with the neutral ankle joint alignment. Other gait parameters were close to the normative data with the neutral ankle joint alignment. For the transfemoral amputee, dorsiflexed alignment of the ankle joint created high pressure on the lateral aspect of the socket, on the other hand, plantarflexed alignment resulted in increased pressure on the medial aspect of the socket. For the transtibial amputee, dorsiflexed alignment of the ankle resulted in high pressure on the antero-lateral aspect of the socket during mid-stance, but plantarflexion of the ankle joint showed slight increases in pressure at the same location in the socket. The present study clearly demonstrated that malalignment of a prosthesis results in localized increasing pressure within the socket. Proper alignment of the prosthesis is required in order to acquire an appropriate socket-limb interface as well as the proper gait.

  • PDF

골유착성 임플랜트 보철물의 캔틸레버 위치와 길이변화에 따른 삼차원 유한요소법적 응력분석 (A THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF OSSEOINTEGRATED PROSTHESIS ACCORDING TO THE LOCATION AND LENGTH OF CANTILEVER)

  • 장복숙;김창회;김영수
    • 대한치과보철학회지
    • /
    • 제34권3호
    • /
    • pp.501-532
    • /
    • 1996
  • This study investigated the effects of cantilever length, location and load condition on stress distribution developed in the implants, prostheses and supporting tissues. The osseointegrated prostheses with two 10mm Branemark implants at 2nd premolar and 1st molar sites with cantilever extensions at 1st premolar, 2nd and 3rd molar sites were constructed. Under 100N, 200N of vertical and $45^{\circ}$ oblique loads at the cantilever pontics, stress distribution patterns and displacement were analyzed with three dimensional finite element method. The results were as follows : 1. The stress was concentrated at the joint of the cantilever pontic and implant superstructure, the neck of implant and the ridge crest near the cantilever But there was little load transfer to the lower supporting tissues of implants. 2. The implant near the cantilever was displaced inferiorly while the implant far from the cantilever was displaced superiorly. In horizontal direction the implants were displaced to the direction where the loads were applied, except the apexes of the implants. 3. In case of anterior cantilever, the stress and displacement were higher than the prosthesis connected with natural tooth. 4. The stress developed in the posterior cantilevered type was higher than in the anterior cantilevered type. The greastest stress was concentrated at the ridge crest near the posterior cantilever. 5. The longer the cantilever, the more the stress was developed and was concentrated at the joint of the cantilever pontic and implant superstructure. 6. Under oblique load, the stress was concentrated at the necks of implants and the ridge crests, but decreased at the joint of the cantilever pontic and implant superstructure than under vertical load.

  • PDF

유한요소법을 이용한 인공 고관절의 접촉응력 해석에 관한 연구 (Contact Stress Analysis of Artificial Hip Joints Using Finite Element Method)

  • 김청균;윤종덕
    • Tribology and Lubricants
    • /
    • 제13권1호
    • /
    • pp.82-87
    • /
    • 1997
  • The modern orthopaedics frequently uses the total hip replacement in the artificial hip joint. The wear in this joint requires a re-replacement of hip joints because it is under the severe load and friction conditions. To solve these problems the previous studies have been mainly focussed on the development of new materials. The research of new materials, however, needs much time and effort since it should be experimented for its bio-compatibility, friction, and wear characteristics. To reduce the work, in this study, the finite element analysis is applied to find new combinations of bio-materials in the total hip replacement which has the excellent contact characteristics. A non-linear FEM program MARC with 5-node axisymmetric element was used for analyzing the contact stresses between the hip joints. The computed results show that in case of acetabulum UHMWP has good characteristics, in femoral head, $Al_2O_3$, and in stem, Ti6Al4V.

주관절의 생역학 (Biomechanics of the Elbow)

  • 문준규
    • Clinics in Shoulder and Elbow
    • /
    • 제13권1호
    • /
    • pp.141-145
    • /
    • 2010
  • 목적: 주관절의 생역학은 주관절 손상의 병인을 이해하고 임상적 치료의 과학적 기초를 제공하는 의학이다. 저자는 생역학적인 관점에서 주관절 손상의 진단과 치료의 개념을 요약하였다. 대상 및 방법: 주관절 역학은 크게 운동학, 동역학 그리고 이를 바탕으로 한 안정성의 분야로 나누어 설명할 수 있다. 이는 주관절을 구성하는 수동적 또는 능동적 구조물로 유지된다. 수동적 구조물은 골성 구조와 관절낭 및 측부인대들이 있으며 능동적 구조물은 주관절을 둘러싼 근육들이 해당된다. 이 구조물들이 유기적으로 작용하여 주관절의 안정성, 힘의 전달 그리고 운동을 유지한다. 결과 및 결론: 주관절의 생역학은 주관절 손상에 대한 수술적 치료에 대한 정보를 제공하며 새로운 주관절 인공대치물에 대한 개선 및 발전을 가져다 주며, 또한 주관절의 기초 연구에 기여 할 수 있는 학문이다.

근골격 모델을 이용한 대퇴절단환자의 계단보행에 대한 동역학 해석 (Dynamic Analysis of Stair Climbing for the Above-knee Amputee with Musculoskeletal Models)

  • 배태수;김신기;문무성
    • 한국정밀공학회지
    • /
    • 제24권7호
    • /
    • pp.133-138
    • /
    • 2007
  • It is important to understand the characteristics of amputee gait to develop more advanced prostheses. The aim of this study was quantitatively to analyze the stair climbing task for the above-knee amputee with a prosthesis and to predict muscle forces and joint moments at musculoskeletal joints by dynamic analysis. The three-dimensional musculoskeletal model of lower extremities was constructed by gait analysis and transformation software for one above-knee amputee and ten healthy people. The measured ground reaction forces and kinematical data of each joint by gait analysis were used as input data during inverse dynamic analysis. Lastly, dynamic analysis of above-knee amputee during stair climbing were performed using musculoskeletal models. The results showed that summed muscle farces of hip extensor of amputated leg were greater than those of sound leg but the opposite results were revealed at hip abductor and knee flexor of amputated leg. We could also find that the higher moments at hip and knee joint of sound leg were needed to overcome the flexion moment caused by body weight and amputated leg. In conclusion, dynamic analysis using musculoskeletal models may be a useful mean to predict muscle forces and joint moments for specific motion tasks related to rehacilitation therapy..

Customized spacers in provisional treatment of temporomandibular joint ankylosis: a case report

  • Caio Augusto Munuera Ueti;Felipe Burigo Daniel Dos Santos;Murillo Chiarelli;Luiza Brum Porto;Matheus Brum Marques Bianchi Savi
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제50권3호
    • /
    • pp.166-169
    • /
    • 2024
  • Ankylosis of the temporomandibular joint (TMJ) is a condition in which the mandibular condyle fuses with the mandibular fossa through fibrous or bone tissue. It is a debilitating pathology that interferes with chewing, speaking, and oral hygiene. Currently, alloplastic reconstruction is considered the gold standard for treating severely compromised TMJs, such as in ankylosis. The article describes a patient with a history of facial trauma, with bilateral ankylosis of the TMJs, inability to open his mouth, and poor dental condition. Due to a long period of immobilization of approximately 40 years, the initial treatment plan was to remove the ankylosis bilaterally and install customized PMMA (polymethylmethacrylate) spacers. The patient gained mouth opening and improved chewing quality with one year of customized spacer use prior to definitive alloplastic replacement with stock-type TMJ prostheses. Customized joint spacers are a provisional treatment option when definitive alloplastic reconstruction is not indicated. Spacers provide the patient with progressive jaw function and mobility gains.

소아 악성 골종양의 치료에서 확장형 종양대치물의 이용 (Use of Expandable Prostheses in Malignant Bone Tumors in Children)

  • 한일규;이상훈;조환성;오주한;김한수
    • 대한골관절종양학회지
    • /
    • 제14권1호
    • /
    • pp.10-16
    • /
    • 2008
  • 효과적인 항암 약물요법의 발달과 사지의 절단술에 따르는 기능적인 경제적인 비효율성은 뼈의 원발성 암 환자에서 사지 구제술의 발달을 가져 왔다. 소아에서의 사지 구제술은 종양의 광범위 절제 시 성장판이 같이 절제되어 건측과의 사지 길이 차이가 발생하게 될 수 있고 소아 환자들의 왕성한 활동성 때문에 견고하고 내구성 있는 재건술이 필요하다. 소아 환자에서 악성 골종양의 절제 후 성장한 만큼 대치물의 길이도 같이 늘일 수 있는 확장형 종양 대치물(expandable tumor prosthesis)을 이용한 재건술이 시행되어 왔으나 모든 환자에서 만족스러운 결과를 가져오진 못하였다. 최근 들어 확장형 종양 대치물의 발달로 합병증의 발생을 줄이면서 비침습적인 방법으로 사지 길이를 맞추고 종양 대치물의 수명을 길게 하는 시도들이 늘고 있다. 본 논문에서는 확장형 종양 대치물의 적응증, 특성 및 합병증 등에 대해서 짚어 보고자 한다.

  • PDF

Finite element analysis of the femur fracture for a different total hip prosthesis (Charnley, Osteal, and Thompson)

  • Mohammed El Sallah Zagane;Moulgada Abdelmadjid;Murat Yaylaci;Sahli Abderahmen;Ecren Uzun Yaylaci
    • Structural Engineering and Mechanics
    • /
    • 제88권6호
    • /
    • pp.583-588
    • /
    • 2023
  • Total hip replacement is a crucial intervention for patients with fractured hips who face challenges in natural recovery. The design of durable prostheses requires a comprehensive understanding of the natural processes occurring in bone. This article focuses on static loading analysis, specifically during stumbling activity, aiming to enhance the longevity of prosthetic implants. Three distinct implants, Charnley, Osteal, and Thompson, were selected for a detailed study to determine the most appropriate model. The results revealed critical insights into the distribution of Von Mises stresses on the components of femoral arthroplasty, including the cement, implant, and cortical bone. Furthermore, the examination of shear stress within the cement emerged as a pivotal aspect for all three implants, playing a crucial role in evaluating the performance and durability of hip prostheses. The conclusions drawn from this study strongly suggest that the Thompson model stands out as the most suitable choice for hip joint implants.