Search Result 1,235, Processing Time 0.028 seconds

Osteoporotic Ankle Fracture (골다공증성 족관절 골절)

  • Hyobeom Lee;Cheolhyun Kim;Gab-Lae Kim
    • Journal of Korean Foot and Ankle Society
    • /
    • v.27 no.2
    • /
    • pp.43-48
    • /
    • 2023
  • The incidence of osteoporotic ankle fractures is increasing as the population ages. These fractures are becoming more common in clinical practice and require careful management because of the higher likelihood of developing complications than typical ankle fractures. The introduction of a method for measuring the ankle joint bone mineral density is a valuable tool for assessing the bone quality of the ankle joint. By evaluating the bone mineral density, healthcare professionals can better understand the extent of osteoporosis and the overall strength of the ankle joint. This information is crucial for determining the appropriate treatment for individual fractures. Several factors must be considered when deciding on the treatment for osteoporotic ankle fractures. These include the ankle joint bone mineral density, skin condition, any comorbidities the patient may have, and the patient's functional demands. Taking these factors into consideration allows healthcare providers to tailor the treatment plan to the specific needs and the circumstances of each patient. By applying the appropriate treatment, it is expected that the complications associated with osteoporotic ankle fractures can be minimized, and the prognosis for patients can be improved.

A Study on a Dual Electromagnetic Sensor System for Weld Seam Tracking of I-Butt Joints

  • Kim, J.-W.;Shin, J.-H.
    • International Journal of Korean Welding Society
    • /
    • v.2 no.2
    • /
    • pp.51-56
    • /
    • 2002
  • The weld seam tracking system for arc welding process uses various kinds of sensors such as arc sensor, vision sensor, laser displacement sensor and so on. Among the variety of sensors available, electro-magnetic sensor is one of the most useful methods especially in sheet metal butt-joint arc welding, primarily because it is hardly affected by the intense arc light and fume generated during the welding process, and also by the surface condition of weldments. In this study, a dual-electromagnetic sensor, which utilizes the induced current variation in the sensing coil due to the eddy current variation of the metal near the sensor, was developed for arc welding of sheet metal I-butt joints. The dual-electromagnetic sensor thus detects the offset displacement of weld line from the center of sensor head even though there's no clearance in the joint. A set of design variables of the sensor was determined far the maximum sensing capability through the repeated experiments. Seam tracking is performed by correcting the position of sensor to the amount of offset displacement every sampling period. From the experimental results, the developed sensor showed the excellent capability of weld seam detection when the sensor to workpiece distance is near less than 5 ㎜, and it was revealed that the system has excellent seam tracking ability for the I-butt joint of sheet metal.

  • PDF

Rapid Functional Enhancement of Ankylosing Spondylitis with Severe Hip Joint Arthritis and Muscle Strain (고관절염과 근 긴장을 동반한 강직성 척추염의 빠른 기능 회복)

  • Hwang, Sangwon;Im, Sang Hee;Shin, Ji Cheol;Park, Jinyoung
    • Clinical Pain
    • /
    • v.18 no.2
    • /
    • pp.121-125
    • /
    • 2019
  • Arthritis of hip joints deteriorates the quality of life in ankylosing spondylitis (AS) patients. Secondary to the articular inflammatory process, the shortened hip-girdle muscles contribute to the decreased joint mobility which may lead to the functional impairment. As the limitation of range of motion (ROM) usually progress slowly, clinicians regard it as a chronic condition and prescribe long-term therapy. However, by short-term intensive multimodal treatment, a 20-year-old man diagnosed as AS with severely limited hip joint ROM who relied on crutches doubled the joint angle and could walk independently only within 2 weeks. The combination included intra-articular steroid injection, electrical twitch obtaining intramuscular stimulation, extracorporeal shock wave therapy, heat, manual therapy, and stretching exercises. The management focused on the relaxation of hip-girdle muscles as well as the direct control of intra-articular inflammation. Hereby, we emphasize the effectiveness of intensive multimodal treatment in improving the function even within a short period.

A vision-based system for inspection of expansion joints in concrete pavement

  • Jung Hee Lee ;bragimov Eldor ;Heungbae Gil ;Jong-Jae Lee
    • Smart Structures and Systems
    • /
    • v.32 no.5
    • /
    • pp.309-318
    • /
    • 2023
  • The appropriate maintenance of highway roads is critical for the safe operation of road networks and conserves maintenance costs. Multiple methods have been developed to investigate the surface of roads for various types of cracks and potholes, among other damage. Like road surface damage, the condition of expansion joints in concrete pavement is important to avoid unexpected hazardous situations. Thus, in this study, a new system is proposed for autonomous expansion joint monitoring using a vision-based system. The system consists of the following three key parts: (1) a camera-mounted vehicle, (2) indication marks on the expansion joints, and (3) a deep learning-based automatic evaluation algorithm. With paired marks indicating the expansion joints in a concrete pavement, they can be automatically detected. An inspection vehicle is equipped with an action camera that acquires images of the expansion joints in the road. You Only Look Once (YOLO) automatically detects the expansion joints with indication marks, which has a performance accuracy of 95%. The width of the detected expansion joint is calculated using an image processing algorithm. Based on the calculated width, the expansion joint is classified into the following two types: normal and dangerous. The obtained results demonstrate that the proposed system is very efficient in terms of speed and accuracy.

Clinical research of Bee-venom Acupuncture effects on Rheumatoid arthritis (봉약침을 이용한 류마토이드 관절염의 임상적 연구)

  • Hwang, Yoo-Jin;Lee, Geon-Mok;Hwang, Woo-Jun;Seo, Eun-Mi;Jang, Jong-Deok;Yang, Gui-Bi;Lee, Seung-Hoon;Lee, Byung-Chul
    • Journal of Acupuncture Research
    • /
    • v.18 no.5
    • /
    • pp.33-42
    • /
    • 2001
  • Objective : To evaluate the effect of treatment for Rheumatoid arthritis by using Bee-venom Acupuncture that is well known for anti-inflammatory effect and function of activating immune system. Methods : Evaluated the result of Bee-venom Acupuncture treatment twice in a week for patients who diagnosised as rheumatoid arthritis by 7 criteria of US Rheumatism Academy. Results : 1. If you see the distribution chart, sexual rate of male and female was 1:2.75 and age distribution shows as age ascend it shows high. 2. If you see the duration distribution, it shows chronic tendency in order of more than 6 months (59.5%), 2 to 5 months, and 1 month. 3. If you see the invaded region distribution, it shows chronic tendency in order of finger(17 cases), wrist joint(16 cases), knee joint(16 cases), ankle joint(10 cases), elbow joint(8 cases), shoulder joint(7 cases), feet(7 cases), hip joint(5 cases), low back(3 cases) and neck(2 cases). 4. If you see the result of duration distribution treatment, the improvement index is rising in order of within a month, 2 to 5 months, and over 6 months. So it shows that it has good result of treatment within a month. 5. If you see the invaded region, it shows high improvement index in order of low back, hop joint, shoulder joint, wrist joint, feet, knee joint, finger, elbow joint, ankle joint and neck. 6. If you see the result of morning stiffness time before treatment, it shows good effect of treatment in order of 2-3hrs, 30min.-an hr, an hr to 2hrs, and 0-30min. 7. If you see the patients satisfaction after Bee-venom Acupuncture treatment, Excellent is 6 cases, Good is 7 cases, and Moderate 2 cases. Conclusions : It will have greater treatment effect if herbal medicine, moxibustion, and acupuncture are used together as patients whole body condition and symptoms with Bee-venom Acupuncture for rheumatoid arthritis that is chronic inflammatory disease.

  • PDF

Analysis on the Deformation Characteristics of a Pillar between Large Caverns by Burton-Bandis Rock Joint Model (Barton-Bandis 절리 모델에 의한 지하대공동 암주의 변형 특성 연구)

  • 강추원;임한욱;김치환
    • Tunnel and Underground Space
    • /
    • v.11 no.2
    • /
    • pp.109-119
    • /
    • 2001
  • Up to now single large cavern was excavated for each undergroud hydraulic powerhouse in Korea. But the Yangyang underground hydraulic powerhouse consists of two large caverns; a powerhouse cavern and main transformer cavern. In this carte, the structural stability of the caverns, especially the rock pillar formed between two large caverns, should be guaranteed to be sound to make the caverns permanently sustainable. In this research, the Distinct Element Method(DEM) was used to analyze the structural stability of two caverns and the rock pillar. The Barton-Bandis joint model was used as a constitutive model. The moot significant parameters such as in-site stress, JRC of in-situ natural joints, and spatial distribution characteristics of discontinuities were acquired through field investigation. In addition, two different cases; 1) with no support system and 2) with a support system, were analysed to optimize a support system and to investigate reinforcing effects of a support system. The results of analysis horizontal displacement and joint shear displacement proved to be reduced with the support system. The relaxed zone in the rock pilar also proved to be reduced in conjunction with the support system. Having a support system in place provided the fact that the non zero minimum principal stresses were still acting in the rock pillar so that the pillar was not under uniaxial compressive condition but under triaxial compressive condition. The structural stability f an approximately 36 m wide rock pillar between two large caverns was assured with the appropriate support system.

  • PDF

Temporomandibular joint disc plication with MITEK mini anchors: surgical outcome of 65 consecutive joint cases using a minimally invasive approach

  • Lee, Bu-Kyu;Hong, Jun Hee
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.14.1-14.11
    • /
    • 2020
  • Background: The purpose of this study is to introduce our modified disc plication technique using MITEK mini anchors and to evaluate the clinical outcome for patients with internal derangement (ID) of the temporomandibular joint (TMJ). Patients and methods: We evaluated 65 joints in 46 patients, comprised 32 women and 14 men, who first visited the Asan Medical Center from December 2012 to December 2016. The age of the patients ranged from 14 to 79 years, with a mean age of 36.6 years. The patients presented with joint problems including pain, joint noise, and mouth opening limitation (MOL). Patients who met our inclusion criteria underwent unilateral or bilateral disc repositioning surgery with our minimally invasive disc plication technique using MITEK mini anchors and No. 2-0 Ethibond® braided polyester sutures. The variables taken into account in this study were the range of maximum mouth opening (MMO), painful symptoms (evaluated with the visual analog scale, VAS), and the type of noise (click, popping, crepitus) in the TMJ. Results: Preoperative examination revealed painful symptoms in 50.7% (n = 35) of the operated joints (n = 69) and the presence of clicks in 56.5% (n = 39). Postoperative examination revealed that 4.3% (n = 3) of the operated joints had painful symptoms with lower intensity than that in the preoperative condition. Additionally, 17.4% (n = 12) had residual noise in the TMJ, among which two were clicking and the other 10 had mild crepitus. The intensity of the postoperative residual noise was significantly decreased in all cases compared to that in the preoperative condition. Among patients with MOL below 38 mm (n = 18), the mean MMO was 31.4 mm preoperatively and 44.2 mm at 6 months postoperatively, with a mean increase of 13.8 mm. A barely visible scar at the operation site was noted during the postoperative observation period, with no significant complications such as facial palsy or permanent occlusal disharmony. Conclusion: Subjective symptoms in all patients improved following the surgery. TMJ disc plication using MITEK mini anchors with our minimally invasive approach may be a feasible and effective surgical option for treating TMJ ID patients who are not responsive to conservative treatment.

Torque Estimation of the Human Elbow Joint using the MVS (Muscle Volume Sensor) (근 부피 센서를 이용한 인체 팔꿈치 관절의 동작 토크 추정)

  • Lee, Hee Don;Lim, Dong Hwan;Kim, Wan Soo;Han, Jung Soo;Han, Chang Soo;An, Jae Yong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.6
    • /
    • pp.650-657
    • /
    • 2013
  • This study uses a muscle activation sensor and elbow joint model to develop an estimation algorithm for human elbow joint torque for use in a human-robot interface. A modular-type MVS (Muscle Volume Sensor) and calibration algorithm are developed to measure the muscle activation signal, which is represented through the normalization of the calibrated signal of the MVS. A Hill-type model is applied to the muscle activation signal and the kinematic model of the muscle can be used to estimate the joint torques. Experiments were performed to evaluate the performance of the proposed algorithm by isotonic contraction motion using the KIN-COM$^{(R)}$ equipment at 5, 10, and 15Nm. The algorithm and its feasibility for use as a human-robot interface are verified by comparing the joint load condition and the torque estimated by the algorithm.

Inclined Face Detection using JointBoost algorithm (JointBoost 알고리즘을 이용한 기울어진 얼굴 검출)

  • Jung, Youn-Ho;Song, Young-Mo;Ko, Yun-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.5
    • /
    • pp.606-614
    • /
    • 2012
  • Face detection using AdaBoost algorithm is one of the fastest and the most robust face detection algorithm so many improvements or extensions of this method have been proposed. However, almost all previous approaches deal with only frontal face and suffer from limited discriminant capability for inclined face because these methods apply the same features for both frontal and inclined face. Also conventional approaches for detecting inclined face which apply frontal face detecting method to inclined input image or make different detectors for each angle require heavy computational complexity and show low detection rate. In order to overcome this problem, a method for detecting inclined face using JointBoost is proposed in this paper. The computational and sample complexity is reduced by finding common features that can be shared across the classes. Simulation results show that the detection rate of the proposed method is at least 2% higher than that of the conventional AdaBoost method under the learning condition with the same iteration number. Also the proposed method not only detects the existence of a face but also gives information about the inclined direction of the detected face.

An Investigation of the Effect of the Height of Wteps on the Joint Moment of Lower Extremities of the Elderly While Walking Downstairs (노인의 계단 내려가기 동작 시 계단 높이와 하지 관절 모멘트와의 관계 연구)

  • Eun, Seon-Deok
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.4
    • /
    • pp.31-38
    • /
    • 2006
  • The purpose of this study was to investigate the effect of changing the steps height on the joint moment of lower extremity in stair-descent activity of elderly persons. Data were collected by 3-D cinematography and force platform. 9 male elderly subjects in the 60s and 70s participated in this study. All subjects performed a stair-descent in four different heights of stairs (10, 14, 18, 22cm) having 5 step staircase. The results were as follows. 1. For the step height of 22cm the maximum. plantarflexion moment was the smallest and the largest for the step height of 14cm. 2. There was not a statistical difference shown for the extension moment of the knee joint for the different height of steps. 3. There was not a statistical difference shown for the flexion moment of the hip joint for the varying height of steps but on average for the 18cm step this increased rapidly. 4. The smallest maximum. value for inversion moment was revealed for the step height of 10cm and this increased significantly for the step height of 22cm. 5. The smallest maximum. value for abduction moment of the hip joint was revealed for the step height of 10cm and this increased significantly for the step height of 22cm. 6. There was no significant difference shown for the maximum. abduction moment for the hip joint. The main conclusion is that there is a huge difference in the moment of the lower extremities for the elderly while walking down a stairs with a step height above 18 cm and that this moment increased or decreased rapidly under a condition of step height being 22cm. With the results from this research and related research of elderly walking upstairs it can be shown that the step height has a large role in the safety for the elderly.