Vacuum Packaging Technology of AC-PDP using Direct-Joint Method

  • Lee, Duck-Jung;Lee, Yun-Hi;Moon, Gwon-Jin;Kim, Jun-Dong;Choi, Won-Do;Lee, Sang-Geun;Jang, Jin;Ju, Byeong-Kwon
    • Journal of Information Display
    • /
    • 제2권4호
    • /
    • pp.34-38
    • /
    • 2001
  • We suggested new PDP packaging technology using the direct joint method, which does not need an exhausting hole and tube. The advantages of this method are simple process, short process time and time panel package. To packaging, we drew the seal line of glass frit by dispenser followed by forming the lump, which provide pumping-out path during the packaging process. And, we have performed a pretreatment of glass frit to reduce the out-gases. After which, both front and rear glass plates were aligned and loaded into vacuum packaging chamber. The 4-inch monochrome AC-PDP was successfully packaged and fully emitted with brightness of 1000 $cd/m^2$. Also, glass frit properties for pretreatment condition was investigated by AES and SEM analyses.

  • PDF

리튬이온전지의 밀봉용접을 위한 펄스 Nd:YAG레이저 용접조건의 최적화 (Optimization of Pulsed Nd:YAG Laser Welding Conditions for Sealing of Lithium-ion Battery)

  • 김종도;유승조;김장수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권5호
    • /
    • pp.623-628
    • /
    • 2006
  • Laser material processing is a very fast advancing technology for various industrial applications. because of many advantages. Its major advantage of less and controlled heat input has been exploited successfully for the very critical application of aluminium alloy welding. This study suggested the occurrence source of weld-defects and its solution methods in a welding of lithium ion battery by pulsed Nd:YAG laser. In experiment. battery case has changed over joint geometry from welding of side position to flat one. In the case of a electrolyte injection hole in order to seal it. welding is carried out after pressing Al ball. At this time. an eccentric degree. contact length and gap are worked as a major parameters. As improving the method of Al ball pressing. it was able to reduce an eccentricity. increase the contact length and decrease gap. As a results of a experiment. a sound weld bead shape and crack-free weld bead can be obtained.

리튬이온전지의 밀봉용접을 위한 펄스 Nd:YAG레이저 용접조건의 최적화 (Optimization of Pulsed Nd:YAG Laser Welding Conditions for Sealing of Lithium-ion Battery)

  • 김종도;유승조
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.339-343
    • /
    • 2005
  • Laser material processing is a very fast growing technology for various industrial applications, because of many advantages. Its major advantage of less and controlled heat input has been exploited successfully for the very critical application of aluminium alloy welding. This study suggested the occurrence source of weld-defects and its solution methods in a welding of lithium ion battery by pulsed Nd:YAG laser. In experiment, battery case has changed over joint geometry from welding of side position to flat one. In case of a electrolyte injection hole in order to seal it, welding is carried out after pressing Al ball. At this time, an eccentric degree, contact length and gap are worked as a major parameters. As improving the method of Al ball pressing, it was able to reduce an eccentricity, increase the contact length and decrease gap. As a results of a experiment, a sound weld bead shape and crack-free weld bead can be obtained.

  • PDF

방수형 로봇팔의 설계, 실험 및 제어 연구 (A study on design, experiment control of the waterproof robot arm)

  • 하지훈;주영도;김동희;김준영;최형식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권6호
    • /
    • pp.648-657
    • /
    • 2014
  • 본 논문에서는 화재나 홍수로 인하여 침수된 건물 내부를 탐사할 수 있는 새로운 방수형 4축 로봇팔을 설계하고 로봇의 기구학 및 동역학 해석을 수행한다. 로봇팔은 카메라를 이용한 탐사를 위한 Pitch-Pitch-Pitch-Yaw 4축 구조로 설계하고, 이를 구동하기 위한 관절구동기의 용량을 선정한다. 또한 수심 10m의 방수가능한 관절구동기를 설계 하고 실제 구동시험을 통하여 방수성능을 검증한다. 설계한 로봇팔의 순기구학 및 역기구학 식의 해석을 통해 닫힌 해를 유도하며, 메커니컬실의 마찰력을 고려한 로봇팔의 운동방정식을 뉴턴-오일러 방법에 의해 유도한다. 유도한 동역학식을 이용하여 개발한 로봇이 목표궤적을 잘 추종할 수 있도록 슬라이딩모드 제어기를 설계하고, 시뮬레이션을 통해 그 성능을 확인한다.

Sealer의 사용이 임프란트 나사의 안정성에 미치는 영향 (A STUDY ON THE STABILITY OF IMPLANT SCREW BY USE OF THE SEALER)

  • 이흥태;김낙형;정재헌
    • 대한치과보철학회지
    • /
    • 제39권4호
    • /
    • pp.366-375
    • /
    • 2001
  • The objective of this study was to investigate the surface contact and screw joint stability between screw and implant interface by use of sealer. The implants evaluated in this study were Steri-Oss futures(Hexlock $3.8D{\times}10mm$: Steri-Oss, Yorba Linda, CA), and Steri-Oss staight abutment. Titanium alloy screws were used to secure abutments to implants. The other titanium alloy screws applicating sealer(Impla-Seal, Implant Support Systems, Inc. Irvine, CA) were used to secure abutments to implants. In one another sample, 6kg of force was applied during simulated intraoral movements after abutment screws were secured to the implants with sealer. All samples were cross sectioned with sandpaper and polished with $0.1{\mu}m\;Al_2O_3$. Then samples were recorded with an scanning electron microscope. The results were as follows : 1. In the case of titanium alloy screw, irregular contacts and relatively large gap were present at thread mating surface. Also abutment screw/implant interface demonstrate incomplete seating and only one surface contact of threads between implant and screw. 2. In the case of titanium alloy screw applecating sealer, sealer was present between implant and screw. Therefore implant and screw had relatively close and tight contact without the presence of large gap. 3. On the other hand, in the case of titanium alloy screw applicating sealer and dynamic loading of suprastructures, sealer was partially present between implant and screw. Conclusively, sealer fills voids, creating a barrier to moisture and bacteria. In addition, loading of suprastructures may change the situation and limit the indications for gap sealing.

  • PDF

Effect of Ti and Si Interlayer Materials on the Joining of SiC Ceramics

  • Jung, Yang-Il;Park, Jung-Hwan;Kim, Hyun-Gil;Park, Dong-Jun;Park, Jeong-Yong;Kim, Weon-Ju
    • Nuclear Engineering and Technology
    • /
    • 제48권4호
    • /
    • pp.1009-1014
    • /
    • 2016
  • SiC-based ceramic composites are currently being considered for use in fuel cladding tubes in light-water reactors. The joining of SiC ceramics in a hermetic seal is required for the development of ceramic-based fuel cladding tubes. In this study, SiC monoliths were diffusion bonded using a Ti foil interlayer and additional Si powder. In the joining process, a very low uniaxial pressure of ~0.1 MPa was applied, so the process is applicable for joining thin-walled long tubes. The joining strength depended strongly on the type of SiC material. Reaction-bonded SiC (RB-SiC) showed a higher joining strength than sintered SiC because the diffusion reaction of Si was promoted in the former. The joining strength of sintered SiC was increased by the addition of Si at the Ti interlayer to play the role of the free Si in RB-SiC. The maximum joint strength obtained under torsional stress was ~100 MPa. The joint interface consisted of $TiSi_2$, $Ti_3SiC_2$, and SiC phases formed by a diffusion reaction of Ti and Si.

내부 원추형 연결형태 임플란트에서 지대주 나사머리의 좌면각도가 연결부 기계적 안정성에 미치는 영향 (Influence of bearing surface angle of abutment screw on mechanical stability of joint in the conical seal design implant system)

  • 김주현;허중보;윤미정;강은숙;허재찬;정창모
    • 구강회복응용과학지
    • /
    • 제30권3호
    • /
    • pp.206-214
    • /
    • 2014
  • 목적: 내부 원추형 연결형태 임플란트에서 지대주 나사의 좌면각도가 연결부의 기계적 안정성에 미치는 영향을 알아보기 위함이다. 연구 재료 및 방법: 원추형 연결구조 티타늄 임플란트와 시멘트 유지형 지대주, 텅스텐 카바이드 코팅된 티타늄 합금 지대주 나사를 사용하였다. 좌면각도가 $45^{\circ}$$90^{\circ}$를 갖는 지대주와 지대주 나사를 제작하여 30 Ncm 조임회전력으로 지대주를 체결한 후 하중을 가하고 체결 및 하중 부여에 따른 침하량을 측정하였다(n = 5). 유압식 피로시험기에 임플란트를 고정하고 스테인리스 스틸 금속관을 지대주에 합착하였다. 이 후 반복 하중을 가한 후 풀림토크 변화량을 측정하고, 압축굽힘강도와 피로강도를 측정하였다(n = 5). 결과: 지대주 침하량은 지대주나사 체결 시 가장 크게 나타났으며(P < 0.05), 나사체결과 하중부여에 따른 총 침하량은 $45^{\circ}$군보다 $90^{\circ}$군에서 더 크게 측정되었다(P < 0.05). 반복하중 부여 후 풀림 토크, 그리고 최대 압축굽힘강도와 피로강도는 통계적으로 유의한 차이를 보이지 않았다(P > 0.05). 결론: 본 실험조건하에서 지대주 나사머리의 원추형 설계가 지대주의 총 침하량을 약간 감소시키는 효과를 나타냈으나, 연결부의 전체적인 기계적 안정성에 미치는 영향은 크지 않을 것으로 판단된다.

압축 및 내압을 받는 고무 오링의 기밀 성능 평가 (An evaluation on sealing performance of elastomeric O-ring compressed and highly pressurized)

  • 박성한;김재훈;김원훈
    • 한국정밀공학회지
    • /
    • 제26권2호
    • /
    • pp.86-93
    • /
    • 2009
  • Elastomeric O-rings have been the most common seals due to their excellent sealing capacity, and availability in costs and sizes. One of the critical applications of O-ring seals is solid rocket motor joint seal where the operating hot gas must be sealed during the combustion. This has long been a design issue to avoid the system failure. For laterally constrained, squeezed and pressurized condition, deformed shape of O-ring was measured by computed tomography method and CCD laser sensor, compared with numerical calculations. As clearance gap changes, sealing performance had been evaluated on peak contact stresses at top, bottom and side contact surfaces. As clearance gap increases, peak contact stresses and contact widths in top and side contact surfaces increase, and the asymmetry of stress distributions is promoted due to pressure increase. It is suggested that peak stress of bottom contact surface can be approximated by simple superposition of peak ones due to squeeze and pressure. Under pressurized condition, sealing performance is dependent on not peak stresses of bottom and side contact surfaces but that of top.

인체 사지 및 척추관절의 운동증감패턴에 따른 전신교정치료에 관한 실증적 연구 (The Experimental Study on GCM(General Coordinative Manipulation) which has been studied on the basis of Spine & Limb Extremity)

  • 문상은
    • 대한물리치료과학회지
    • /
    • 제6권2호
    • /
    • pp.1041-1062
    • /
    • 1999
  • This study is to stimulate the model of which top notch muscle stimuli physical therapy has been made on the basis of GCM. GCM has been studied on the hypermobility & hypomobility pattern on the part of spine & extremity, and the body characteristics of four body types, which is the tilting of seal scapular & ilium. The purpose of this study is to analysize the type of GCM which has been focused on the spine & extremity for the patients having dysfunctions of neuromuscular system, being analysized the movement. The result of this study is as following; 1) The First hypothesis: The hypermobility & hypomobility pattern assorted by the tilting of scapular & ilium, as does the former study analysize was claimed that it would be in line with the pattern for hypermobility hypomobility and physical characteristics according to each body type at the percentage of at least 60(p<.001). 2) The 2nd hypothesis : Stimuli therapy of muscle dealing with physical characteristics and joint hypermobility hypomobility has the important role in restoring the deformity and keeping anatomical postural plumb alignment also it would a highly effects on correcting the body even though the stimuli area was limited to four areas and it was lack of time compared with those applied by general physical therapy(p<.001). As above the result, the top-notch type for physical therapy based on hypermobility hypomobility pattern by 4 body types which has been studied on tilting of scapular & ilium is more specificed and specialized than those of general physical therapy technologies. So this study will be believed to dedicate to restoration ideal anatomical postural plumb alignment based on spinal Manipulation and the concept of whole person as well as to being simple and effective to apply.

  • PDF

합류식 하수관거의 유출 특성 분석 조사 (Characteristics and Combined Sewer Overflows)

  • 안기선;장성용;권영호
    • 한국환경과학회지
    • /
    • 제19권6호
    • /
    • pp.747-753
    • /
    • 2010
  • It follows in quality and sewage exclusion method of the investigation objective sector and the Combined Sewer Overflows which is suitable in regional characteristics and the confluence area against the rainfall initially a flow and the medulla and measurement - it analyzes the initial rainfall outflow possibility control plan which is suitable in the domestic actual condition and it proposes the monitor ring plan for the long-term flow and pollution load data accumulation. From the research which it sees the Infiltration water/Influent water and CSOs investigation it passes by the phase of hazard chain and Namwon right time 4 it does not hold reverse under selecting, Measurement it used the hazard automatic flow joint seal Sigma 910 machine and in case 15 minute interval of the I/I, it measured a flow at case 5, 15 minute standing of the CSOs. The water quality investigation for the water leakage investigation of the I/I and the sewage from the point which is identical with flow measurement during on-the-spot inspection duration against 6 items which include the BOD sampling and an analysis, when the rainfall analysis for CSOs fundamental investigation analyzed against 18 items which include the BOD sampling. Consequently, for the optimum interpretation invasion water / inflow water of the this investigation area day average the lowest flow - water quality assessment veterinarian optimum interpretation hazard average per day - lowest flow - it averages a medulla evaluation law department one lowest flow evaluation technique and it selects, it presentation collectively from here it gets, position result with base flow analysis of invasion water / inflow water.