• Title/Summary/Keyword: Joint Research

Search Result 4,202, Processing Time 0.039 seconds

A Study on the Researcher's Perception Survey for Facilitating International Joint Research

  • Noh, Younghee;Shin, Youngji
    • International Journal of Knowledge Content Development & Technology
    • /
    • v.9 no.3
    • /
    • pp.75-101
    • /
    • 2019
  • In this study, we wanted to investigate and analyze the current status of international joint research conducted on researchers who have actually conducted or are doing international joint research and to identify difficulties in promoting international joint research based on this study and propose ways to promote future international joint research. As a result, autonomy of research subjects needs to be guaranteed for the revitalization of international joint research, establishment of international joint research guidelines and contract legal infrastructure, simplification and unification of administrative work system and supplementation of performance-related regulations will be necessary.

Experimental setup for elemental analysis using prompt gamma rays at research reactor IBR-2

  • Hramco, C.;Turlybekuly, K.;Borzakov, S.B.;Gundorin, N.A.;Lychagin, E.V.;Nehaev, G.V.;Muzychka, A. Yu;Strelkov, A.V.;Teymurov, E.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.2999-3005
    • /
    • 2022
  • The new experimental setup has been built at the 11b channel of the IBR-2 research reactor at FLNP, JINR, to study the elemental composition of samples by registration of prompt gamma emission during thermal neutron capture. The setup consists of a curved mirror neutron guide and a radiation-resistant HPGe high-purity germanium detector. The detector is surrounded by lead shielding to suppress the natural background gamma level. The sample is placed in a vacuum channel and surrounded by a LiF shield to suppress the gamma background generated by scattered neutrons. This work presents characteristics of the experimental setup. An example of hydrogen concentration determining in a diamond powder made by detonation synthesis is given and on its basis, the sensitivity of the setup is calculated being ~4 ㎍.

Comparison with Load Transfer Efficiency for Joint Types in Airport Concrete Pavements (줄눈형식에 따른 공항 콘크리트 포장 하중전달율 비교)

  • An, Ji-Hwan;Jeon, Sung-Il;Kwon, Soo-Ahn;Kim, Min-Woo
    • International Journal of Highway Engineering
    • /
    • v.16 no.3
    • /
    • pp.9-20
    • /
    • 2014
  • PURPOSES : This study is to compare load transfer efficiency of key joint and dowel joint for airport concrete pavement. METHODS : As AC150/5320-6D of FAA's [Advisory Circular] was changed into AC150/5320-6E, Key joint type of rigid pavement were excluded from Construction Joints. LTE(Load Transfer Efficiency) of dowel joint and key joint were compared by times and seasons through pavement temperature measurement, ocular investigation and HWD measurement. RESULTS : For the joint performance grade of No. 2(The second) runway of airport, 12% of poor rate was observed in key joint and 2% of poor rate in dowel joint. Poor rate of key joint was increased to 17%, if only No. 3~No. 6 slabs, which are mostly loaded from the airplanes, were applied for the study. In apron area, LTE poor rate of key joint was high in winter, and LTE poor rate of dowel joint was at least above 'Fair' grade. In summer, 'Fair' for key joint, 'Acceptable' for dowel joint appeared. CONCLUSIONS : As results, dowel joint was superior than key joint for LTE. Deviations of seasons and times were smaller in dowel joint's result. And LTE in winter was lower than LTE in summer.

Development of a Joint Torque Sensor Fully Integrated with an Actuator

  • Kim, Bong-Seok;Yun, Seung-Kook;Kang, Sung-Chul;Hwang, Chang-Soon;Kim, Mun-Sang;Song, Jae-Bok
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1679-1683
    • /
    • 2005
  • This paper suggests the new type of a joint torque sensor which is attached at each joint of a manipulator for making compliance. Previous six axis force/torque sensors are high cost and installed end-effector of the manipulator. However, torque on links of previous an end-effector cannot be measured. We design a joint torque sensor that can be fully integrated with an actuator in order to measure applying torque of the manipulator. The sensor system is designed through the structural analysis. The proposed joint torque sensors are installed to the 6 DOF manipulator of a mobile robot for hazardous works and we implemented experiments of measuring applied torque to the manipulator. By the experiment, we proved that the proposed low-cost joint torque sensor gives acceptable performance when we control a manipulator.

  • PDF

Field Test and Analysis of Joint Depths and Timing Contraction Joint Sawing for Concrete Pavement (콘크리트포장의 줄눈깊이 및 절단시기에 관한 유도균열 거동특성 연구)

  • 홍승호;양성철;엄주용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.469-474
    • /
    • 1999
  • The object of study is analysis to joint crack behavior of cracked joint concrete pavement. In the new constructing concrete pavement, joint crack behavior was compared general joint depth D/4 with joint depth D/3 and D/5 that it's environmental effects changed temperature and humidity. After joint saw cutting joint section was predicted crack at joint depth D/5 test section from the result for monitoring development of crack. In the setting of data logger system of the joint section, it's data compared see with the naked eye. In the research, development of crack at the joint section should effect to joint saw timing latter than joint depth. This performance could be the minimum of deterioration to the early curing. In this research, At new constructing of joint concrete pavement of highway, the monitoring system be setting after finished paving and joint sawing. The system and see with the naked eye could be analysis to pavement behaviors from collecting data at the test section. This system could be monitoring shot term and long term. In this report, joint section of crack behavior analysis used to collected data during a month after paving and joint sawing.

  • PDF

A Study on Joint Resistance between Nb-Ti Superconducting Wires for MRI Magnet

  • Oh, Sang-Soo;Yingming Dai;Ha, Dong-Woo;Jang, Hyun-Man;Ryu, Kang-Sik
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.6
    • /
    • pp.90-94
    • /
    • 1997
  • The joints between the superconducting wires are inevitably needed from the requirement of a high magnetic stability with respect to time in the superconducting MRI magnet. In this study, a new superconducting joint using Cu/Nb-Ti sleeve has been tried on the MRI type Nb-Ti superconducting wires. The transformer induction type apparatus was made and applied to measure the joint resistance. A very low joint resistance of 10\ulcorner $\Omega$ could be successfully obtained from this joint method. It was confirmed that the initial rapid current decay occurs before the very stable current decay due to only superconducting joint. Some unstable part in the joint like exposed filaments causes the initial induced current to lower and influence on the increase of the joint resistance.

  • PDF

Diagnosis of Coxofemoral Joint Luxation in a Whooper Swan (Cygnus Cygnus) Using Computed Tomography and Radiography

  • Jinho Jang;Jong-pil Seo;Hyohoon Jeong;Seyoung Lee;YoungMin Yun
    • Journal of Veterinary Clinics
    • /
    • v.41 no.2
    • /
    • pp.139-142
    • /
    • 2024
  • A wild Whooper swan (Cygnus Cygnus) with limping due to an injured left pelvic limb in an accident was rescued on the seashore and transferred to the Jeju Wildlife Rescue Center on November 23rd, 2020. On physical examination, its body condition score was 1 out of 5 due to starvation and dehydration. The left coxofemoral joint was also examined by careful palpating and estimating the damage. Moderated soft tissue swelling and crepitus surrounding the hip joint were confirmed. Radiography and computed tomography (CT) were used together for an accurate diagnosis of the joint. By radiographs readings, it was difficult to accurately confirm the condition of the proximal femur due to superimposition of the synsacrum and internal organs. However, signs such as avulsion fracture of the femoral head and a few fragments around the joint were revealed by CT imaging. Besides, through three-dimensional (3D) image analysis of CT, the dislocated area and condition of the left hip joint could be accurately and easily confirmed. The diagnostic process showing in this paper could be used as a good reference for diagnosing coxofemoral joint luxation in wild swan.

Consideration from the Viewpoint of Chiropractic Correction on the Dysfunction of Temporomandibular Joint

  • Kong, Byung Sun
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.4 no.2
    • /
    • pp.625-632
    • /
    • 2013
  • This study was to investigate the needs of the functional abnormality of the Temporomandibular joint. The purpose of this study was to find out basic concept for the Chiropractic-care necessity of the neuromuscular skeletal patients with functional abnormality of the temporomandibular joint. I evaluated the change of the range of motion, neck pain, headache by post xray, orthopedic test and patient's charts. The range of motion at temporomandibular joint was improved and the necessity of chiropractic care was recognized in the neuromuscular skeletal patients with having temporomandibular joint problems.

Research on Characteristics of Natural Joint with Low Roughness (낮은 거칠기를 갖는 자연절리면의 특성 연구)

  • 이수곤;양홍석;김부성
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.745-750
    • /
    • 2000
  • The shear strength of rock discontinuities is very important in many rock engineering project including analysis of tunnel and slope. But shear strength of rock that acquired through discontinuity shear test is different from soil shear test and more complex. Shear strength is effected by the factors which are various, but it is the best influence of filling material and joint roughness. In this research, we studied shear strength characters of natural joint of phillite that was placed importance on joint roughness, JRC is less low than 8.

  • PDF

Effect of Kinesiotaping and Joint Mobilization on The Metatarsophalangeal Joint Angle and Pain in Hallux Valgus Patients

  • Choi, Jung Hyun;Kim, Nyeon Jun;An, Ho Jung
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.8 no.2
    • /
    • pp.1152-1157
    • /
    • 2017
  • The aim of this study was to observe the effects of kinesiotaping and joint mobilization on the metatarsophalangeal joint angle and pain in hallux valgus patients Twenty-one female hallux valgus patients in their 20s were divided into two groups, a Kinesiotaping group (KT, n=10) and another group with the addition of joint mobilization (KTJM, n=11). After undergoing 6 weeks of intervention, the change in the metatarsophalangeal joint and pain were measured. Metatarsophalangeal joint angle was significantly increased both the KT and the KTMJ group after intervention. In the change of pain, both the KT and KTJM groups on an individual basis also experienced a significant decrease in pain, though comparison between the two groups failed to represent a significant difference. These findings suggest that Kinesiotatping and joint mobilization increased the joint angle and reduced pain.