• Title/Summary/Keyword: Joint Data

Search Result 3,015, Processing Time 0.032 seconds

Automation of Fatigue Life Assessment for Welded Cruciform Joint (십자형 필렛용접부의 피로수명평가 자동화 연구)

  • Lee, Tak-Kee;Han, Seung-Ho;Rim, Chae-Wahn
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.479-484
    • /
    • 2004
  • For the rational design of welded joint, it is needed to assess repeatedly the fatigue life of the joint with various dimensions and welding conditions. In this paper, an automation of repeated process of fatigue life assessment for welded cruciform joint was studied. The process is related to stress analysis in vicinity of weld-toe and fatigue life assessment based on analyzed stress distribution. With the change of design condition including dimensions and/or welding heat input, the above two works have to be performed. Using the commercial tool for system integration, ModelCenter, an automation of the repeated process for welded cruciform joint based on 2D modeling was achieved. In this automation system, data exchanges between programs regardless of commercial or in-house one work well, and parametric studies for optimal design can be performed.

  • PDF

Development of a Model for the Estimation of Knee Joint Moment at MVC (MVC 상태에서의 무릎관절 모멘트 추정을 위한 모델 개발)

  • Nam, Yoon-Su;Lee, Woo-Eun
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.3
    • /
    • pp.222-230
    • /
    • 2008
  • This paper introduces a method of estimating the knee joint moment developed during MVC. By combining the Hill-type muscle model and analytic results on moment arm and musculotendon length change as a function of hip and knee joint angle, the knee joint moment at a specific knee joint angle during MVC is determined. Many differences between the estimated results and the experimental data are noted. It is believed that these differences originate from inaccurate information on the muscle-tendon parameters. The establishment of exact values for the subject's muscle parameters is almost impossible task. However, sensitivity analysis shows that the tendon slack length is the most critical parameter when applying the Hill-type muscle model. The effect of a change of this parameter on the muscle length force relationship is analyzed in detail.

Comparison of Changes in the Muscle Activity of the Quadriceps Femoris Muscle in Relation to the Angles of the Knee Joint on Closed Kinetic Chain (닫힌 역학적 사슬운동에서 무릎관절 각도에 따른 넙다리네갈래근의 근활성도 변화 비교)

  • An, Seong-Ja
    • PNF and Movement
    • /
    • v.10 no.3
    • /
    • pp.25-31
    • /
    • 2012
  • Purpose : This study was intended to compare muscle activity in relation to knee joint angles on closed kinetic chain. Methods : A total of 13 subjects consisting of 5 adult males and 8 adult females were made to make movements maintaining knee joint angles at $30^{\circ}$, $45^{\circ}$ and $90^{\circ}$ on closed kinetic chain and the muscle activity occurring in their vastus medialis, rectus femoris and vastus lateralis was measured. Statistical data were analyzed using oneway ANOVA. Results : On closed kinetic chain, the muscle activity of the vastus medialis, rectus femoris and vastus lateralis increased the most at $90^{\circ}$ among the knee joint angles with statistically significant differences(p<0.05). Conclusion : On closed kinetic chain, it could be seen that as the angle of the knee joint increased, the muscle activity increased.

Measurement on range of two degrees of freedom motion for analytic generation of workspace (작업영역의 해석적 생성을 위한 2자유도 동작의 동작범위 측정)

  • 기도형
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.15-24
    • /
    • 1996
  • To generate workspace analytically using the robot kinematics, data on range of human joints motion, especially range of two degrees of freedom motion, are needed. However, these data have not been investigated up to now. Therefore, in this research, we are to investigate an interaction effect of motions with two degrees of freedom occurred simultaneously at the shoulder, virtual hip(L5/S1) and hip joints, respectively, for 47 young male students. When motion with two degrees of freedom occurred at a joint such as shoulder, virtual hip and hip joints, it was found from the results of ANOVA that the action of a degree of freedom motion may either decrease or increase the effective functioning of the other degree of freedom motion. In other words, the shoulder flexion was decreased as the shoulder was adducted or abducted to $60^{\circ}C$TEX>or abducted from $60^{\circ}C$TEX>to maximum degree of abduction, while the shoulder flexion increased as the joint was abducted from $60^{\circ}C$TEX> to $60^{\circ}C$TEX> The flexion was decreased as the virtual hip was bent laterally at the virtual hip joint, and also did as the hip was adducted or abducted from the neutral position. It is expected that workspace can be generated more precisely based the data on the range of two degrees of joint motion measured in this study.

  • PDF

Recognition of Gap between base Plates for Automated Welding of Thick Plates (후판 자동용접을 위한 용접물의 갭 측정)

  • Yi, Hwa-Cho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.4 s.97
    • /
    • pp.37-45
    • /
    • 1999
  • Many automated welding equipment are used in the industry. However, there are some problems to get quality welds because of the geometric error, thermal distortion, and incorrect joint fit-up. These factors can make the gap between base plates in case of a thick plate welding. The welding product with the quality welds can not be obtained without consideration of the gap. In this paper, the robot path and welding conditions are modified to get the quality weld by detecting the position and size of the gap. In this work, a low-priced laser range sensor is used. The 3-dimensional information is obtained using the motion of a robot, which holds a laser range sensor. The position and size of the gap is calculated using signal processing of the measured 3-dimensional information of joint profile geometry. The data measured by a laser range sensor is segmented by an iterative end point method. The segmented data is optimized by the least square method. The existence of gap is detected by comparing the data with the segmented shape of template. The effects of robot measuring speed and gap size are also tested. The recognizability fo the gap is verified as good by comparing the real joint profile and the calculated joint profile using the signal processing.

  • PDF

External Force Estimation by Modifying RLS using Joint Torque Sensor for Peg-in-Hole Assembly Operation (수정된 RLS 기반으로 관절 토크 센서를 이용한 로봇에 가해진 외부 힘 예측 및 펙인홀 작업 구현)

  • Jeong, Yoo-Seok;Lee, Cheol-Soo
    • The Journal of Korea Robotics Society
    • /
    • v.13 no.1
    • /
    • pp.55-62
    • /
    • 2018
  • In this paper, a method for estimation of external force on an end-effector using joint torque sensor is proposed. The method is based on portion of measure torque caused by external force. Due to noise in the torque measurement data from the torque sensor, a recursive least-square estimation algorithm is used to ensure a smoother estimation of the external force data. However it is inevitable to create a delay for the sensor to detect the external force. In order to reduce the delay, modified recursive least-square is proposed. The performance of the proposed estimation method is evaluated in an experiment on a developed six-degree-of-freedom robot. By using NI DAQ device and Labview, the robot control, data acquisition and The experimental results output are processed in real time. By using proposed modified RLS, the delay to estimate the external force with the RLS is reduced by 54.9%. As an experimental result, the difference of the actual external force and the estimated external force is 4.11% with an included angle of $5.04^{\circ}$ while in dynamic state. This result shows that this method allows joint torque sensors to be used instead of commonly used external sensory system such as F/T sensors.

The Examination of Reliability of Lower Limb Joint Angles with Free Software ImageJ

  • Kim, Heung Youl
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.6
    • /
    • pp.583-595
    • /
    • 2015
  • Objective: The purpose of this study was to determine the reliability of lower limb joint angles computed with the software ImageJ during jumping movements. Background: Kinematics is the study of bodies in motion without regard to the forces or torques that may produce the motion. The most common method for collecting motion data uses an imaging and motion-caption system to record the 2D or 3D coordinates of markers attached to a moving object, followed by manual or automatic digitizing software. Above all, passive optical motion capture systems (e.g. Vicon system) have been regarded as the gold standards for collecting motion data. On the other hand, ImageJ is used widely for an image analysis as free software, and can collect the 2D coordinates of markers. Although much research has been carried out into the utilizations of the ImageJ software, little is known about their reliability. Method: Seven healthy female students participated as the subject in this study. Seventeen reflective markers were attached on the right and left lower limbs to measure two and three-dimensional joint angular motions. Jump performance was recorded by ten-vicon camera systems (250Hz) and one digital video camera (240Hz). The joint angles of the ankle and knee joints were calculated using 2D (ImageJ) and 3D (Vicon-MX) motion data, respectively. Results: Pearson's correlation coefficients between the two methods were calculated, and significance tests were conducted (${\alpha}=1%$). Correlation coefficients between the two were over 0.98. In Vicon-MX and ImageJ, there is no systematic error by examination of the validity using the Bland-Altman method, and all data are in the 95% limits of agreement. Conclusion: In this study, correlation coefficients are generally high, and the regression line is near the identical line. Therefore, it is considered that motion analysis using ImageJ is a useful tool for evaluation of human movements in various research areas. Application: This result can be utilized as a practical tool to analyze human performance in various fields.

Development of web based shape inspection system for the forging products having complicated shapes (인터넷을 이용한 정밀단조품의 품질평가 시스템 개발에 관한 연구)

  • Park, K.S.;Kim, B.J.;Jang, J.H.;Moon, Y.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.211-214
    • /
    • 2006
  • The outer race of the constant velocity(CV) joint is an important load-supporting automotive part, which transmits torque between the transmission and the wheel. The outer race is difficult to forge, because its shape is very complex and the required dimensional tolerances are very stringent. Therefore, the internet based shape inspection system is developed in this study to provide quick and accurate data through the easy control from users. Proposed system uses mechanical displacement sensors to measure the shape of CV joint that has six inner ball grooves, and commercially available Lab-View program is used to process measured data into the dimensional shape. Developed program provides a simple user interface that enables users real-time access of data measured from industrial production lines. Furthermore, it can exchange measured data via the internet between users and forging system operators. A java applet helped the system connection via internet. A data, IP access, is transmitted to the packet by TCP/IP. Our proposed system has many advantages over current measuring systems including fast and efficient data processing by real-time control, and system flexibility.

  • PDF

Study of Target Tracking Algorithm using iterative Joint Integrated Probabilistic Data Association in Low SNR Multi-Target Environments (낮은 SNR 다중 표적 환경에서의 iterative Joint Integrated Probabilistic Data Association을 이용한 표적추적 알고리즘 연구)

  • Kim, Hyung-June;Song, Taek-Lyul
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.204-212
    • /
    • 2020
  • For general target tracking works by receiving a set of measurements from sensor. However, if the SNR(Signal to Noise Ratio) is low due to small RCS(Radar Cross Section), caused by remote small targets, the target's information can be lost during signal processing. TBD(Track Before Detect) is an algorithm that performs target tracking without threshold for detection. That is, all sensor data is sent to the tracking system, which prevents the loss of the target's information by thresholding the signal intensity. On the other hand, using all sensor data inevitably leads to computational problems that can severely limit the application. In this paper, we propose an iterative Joint Integrated Probabilistic Data Association as a practical target tracking technique suitable for a low SNR multi-target environment with real time operation capability, and verify its performance through simulation studies.

Effects of a Balance Taping on Pain and ROM of the Knee Joint in the Elderly with Lower Limbs Arthritis (밸런스테이핑이 하지 관절염 노인의 하지통증과 무릎관절가동범위에 미치는 효과)

  • Park, Ka-Yoon;Park, Kyung-Sook
    • Korean Journal of Adult Nursing
    • /
    • v.22 no.3
    • /
    • pp.312-321
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the effects of balance taping on pain and Range of Motion (ROM). ROM of the knee joint in the elderly with lower limbs arthritis. Methods: This study was a nonequivalent pretest-posttest design, quasi-experimental study. An experimental group of 35 elderly and a control group of 35 elderly were assigned. Subjects responses to the Visual analogue Scale (VAS) and range of motion scores as measured by a joint goniometer. Data were analyzed by, t-test and repeated measures ANOVA. Results: In the experimental treatment group, the pain score was significantly decreased from 6.46 to 2.09 after balance taping (p<.001). In addition, knee joint ROM of the experimental group was significantly increased from 114.80 to 121.92 after balance taping (p=.003, p<.001, p<.001). Conclusion: This is a very important study as it is an excellent treatment that nurses can utilize and these data support the efficacy of the method.