• Title/Summary/Keyword: Jet Fan

Search Result 106, Processing Time 0.022 seconds

A Study on the Development for the Coastal Fishing Boat attached Protected-Tunnel for Propeller (세미워터제트형 연안어선 개발에 관한 연구)

  • 고재용;심상목;박충환;서성부;배동균
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2003.05a
    • /
    • pp.16-20
    • /
    • 2003
  • Recently, The fast change of fishing boat fishery surrounding environment is connected by request of fan shape development that meet in restructuring of existing fishing boat fishery and new community, economical surrounding. In southern sea district along the coast work and district along the coast fishing bats that sail to exposed propeller fishing net, rope etc.. cold real condition that accident is increasing every year. This study is thing which analyze main performance of minuteness water jet type district along the coast fishing boat through model examination to propeller protection tunnel sticking district along the coast fishing boat that correct existing stem shape for marine accident prevention of district along the coast fishing boat in viewpoint such as ideal and examines.

  • PDF

A comparative study on the relationship between estimates of critical velocity and number of jet fans for smoke control - A 'Fire-JF' contour map in road tunnels (임계속도와 제연팬 용량의 상관관계 연구 - 도로터널의 제연팬 특성도 연구)

  • Kim, Hyo-Gyu;Kim, Eun-Soo;Kim, Nam-Young;Lee, Chang-Woo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.6 no.4
    • /
    • pp.269-278
    • /
    • 2004
  • Recently, critical velocity has become a topic to attract most interests from the researchers in the field of tunnel safety. As the minimum velocity to prevent smoke backlayering during a fire, many equations have been proposed so far, and the following three equations are being considered as a standard method in Korea to calculate the capacity of smoke extraction fans. Equation by Kennedy based on Froude number, Tetzner' s equation with additional variable, ${\beta}$ to modify the Kennedy's equation, and the equation with the concept of super critical velocity by Wu are studied in this paper for the comparative purpose. A contour map describing the relationship between the critical velocity and the capacity of smoke extraction fans is proposed as a tool to calculate the number of jet fans for smoke control during a fire in the local tunnels.

  • PDF

NUMERICAL STUDY OF TURBINE BLADE COOLING TECHNIQUES (터빈 블레이드 냉각시스템에 관한 수치해석적 연구)

  • Kim, K.Y.;Lee, K.D.;Moon, M.A.;Heo, M.W.;Kim, H.M.;Kim, J.H.;Husain, A.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.530-533
    • /
    • 2010
  • This paper presents numerical analysis and design optimization of various turbine blade cooling techniques with three-dimensional Reynolds-averaged Navier-Stokes(RANS) analysis. The fluid flow and heat transfer have been performed using ANSYS-CFX 11.0. A fan-shaped hole for film-cooling has been carried out to improve film-cooling effectiveness with the radial basis neural network method. The injection angle of hole, lateral expansion angle of hole and ratio of length-to-diameter of the hole are chosen as design variables and spatially averaged film-cooling effectiveness is considered as an objective function which is to be maximized. The impingement jet cooling has been performed to investigate heat transfer characteristic with geometry variables. Distance between jet nozzle exit and impingement plate, inclination of nozzle and aspect ratio of nozzle hole are considered as geometry variables. The area averaged Nusselt number is evaluated each geometry variables. A rotating rectangular channel with staggered array pin-fins has been investigated to increase heat transfer performance ad to decrease friction loss using KRG modeling. Two non-dimensional variables, the ratio of the eight diameter of the pin-fins and ratio of the spacing between the pin-fins to diameter of the pin-fins selected as design variables. A rotating rectangular channel with staggered dimples on opposite walls are formulated numerically to enhance heat transfer performance. The ratio of the dimple depth and dimple diameter are selected as geometry variables.

  • PDF

Study of the Smoke Extraction Efficiency Improvement by the Partial Smoke Extraction System in Tunnel Fire (터널화재시 부분배연설비에 의한 배연효율 향상에 관한 연구)

  • Yoo, Yong-ho;Lee, Eui-ju;Shin, Hyun-jun;Shin, Han-cho|;Yoon, Young-hoon;Kim, Chang-whan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.1
    • /
    • pp.53-63
    • /
    • 2006
  • The objective of this study is to analyze the smoke movement and the smoke extraction efficiency using by the partial extraction system for case of tunnel fire. Based on Froude modeling and isothermal model, the 1/20 scaled model tunnel (12m long) was constructed. In the case of the upper critical velocity in the main tunnel, the smoke extraction efficiency shows almost same between group damper and distributed damper. Finally, if the fire occurs on a traffic Jam in a tunnel, it is proposed that the open dampers in partial gallery extract smoke from the main tunnel without jet fan operation. Then, after the passengers have escaped the tunnel, the jet fans work on. On the other hand, If the traffic is uncongested in the tunnel, the jet fans (smoke control system) and partial extraction system (smoke exhaust system) are operated at once in tunnel fire.

  • PDF

Aerosol Jet Deposition of $CuInS_2$ Thin Films

  • Fan, Rong;Kong, Seon-Mi;Kim, Dong-Chan;Chung, Chee-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.159-159
    • /
    • 2011
  • Among the semiconductor ternary compounds in the I-III-$VI_2$ series, $CulnS_2$ ($CulnSe_2$) are one of the promising materials for photovoltaic applications because of the suitability of their electrical and optical properties. The $CuInS_2$ thin film is one of I-III-$VI_2$ type semiconductors, which crystallizes in the chalcopyrite structure. Its direct band gap of 1.5 eV, high absorption coefficient and environmental viewpoint that $CuInS_2$ does not contain any toxic constituents make it suitable for terrestrial photovoltaic applications. A variety of techniques have been applied to deposit $CuInS_2$ thin films, such as single/double source evaporation, coevaporation, rf sputtering, chemical vapor deposition and chemical spray pyrolysis. This is the first report that $CuInS_2$ thin films have been prepared by Aerosol Jet Deposition (AJD) technique which is a novel and attractive method because thin films with high deposition rate can be grown at very low cost. In this study, $CuInS_2$ thin films have been prepared by Aerosol Jet Deposition (AJD) method which employs a nozzle expansion. The mixed fluid is expanded through the nozzle into the chamber evacuated in a lower pressure to deposit $CuInS_2$ films on Mo coated glass substrate. In this AJD system, the characteristics of $CuInS_2$ films are dependent on various deposition parameters, such as compositional ratio of precursor solution, flow rate of carrier gas, stagnation pressure, substrate temperature, nozzle shape, nozzle size and chamber pressure, etc. In this report, $CuInS_2$ thin films are deposited using the deposition parameters such as the compositional ratio of the precursor solution and the substrate temperature. The deposited $CuInS_2$ thin films will be analyzed in terms of deposition rate, crystal structure, and optical properties.

  • PDF

A Study on the Heat and Gas Flow for Fire Simulation in a Tunnel (화재시 터널내 열유동 시뮬레이션 모델 연구)

  • 우경범;김원갑;한화택
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.7
    • /
    • pp.584-591
    • /
    • 2002
  • The objective of the present study is to develop a model to predict heat and gas flow movement by fire in a tunnel. The model includes component models such as turbulence model, combustion model, fire model, jet fan model, etc. It has been validated using the data from Memorial Tunnel Fire Ventilation Test Program. The predictions are in good quantitative agreement with the experimental data in the far-field region of the tunnel. It should be further investigated to develop models for radiation between surfaces, for composite boundary conditions for conduction and convection, and for vigorous turbulent mixing in a tunnel especially for a large size of fire.

Development of Air conditioner Using TEC Module (열전 소자를 이용한 에어컨의 개발)

  • 정문철;구경완;이명섭;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.471-474
    • /
    • 1999
  • 본 논문에서는 열전소자(TEC모듈)를 이용한 에어컨의 개발에 대하여 검토한다. 사용한 TEC모듈의 개수와 TEC모듈의 발열부를 냉각하는 FAN냉각방식과 분사냉각방식에 따른 냉각능력을 평가하였다. 분사냉각방식의 경우에는 기존의 에어컨과 동등한 수준의 냉각능력을 갖는다는 것을 알 수 있었다. 급속냉각은 어렵지만 약 1시간 후부터는 충분히 사용 가능하며, 열전소자 한 개당 약 1평을 냉각할 수 있으며, 기존에어컨의 가격에 비해 약 50∼70%정도로 충분한 가격 경쟁력이 있다. 빙축열 방식 등을 적용하면, peak 쳐t등의 효용성으로 상품화 가능성이 매우 크다고 판단된다.

  • PDF

Country based Domestic Animal Genetic Resource Information System (C-DAGRIS) for Selected African and Asian Countries (선발된 아프리카와 아시아 국가들을 위한 가축유전자원 정보시스템 구축)

  • Dessie, Tadelle;Gebreyesus, Grum;Mamo, Yetnayet;Kim, Dong-Hun;Cho, Gyung-Rae;Jung, Hyun-Jung;Mwai, Okeyo;Oh, Sung-Jong
    • Journal of Embryo Transfer
    • /
    • v.29 no.1
    • /
    • pp.29-33
    • /
    • 2014
  • Accurate information on the genetic and phenotypic characteristics and diversity of the indigenous Farm Animal Genetic Resources (FAnGR) is the basis on which their present and future sustainable utilization and conservation should be made. The paper describes the objectives, structure, functionality, content, utility and future prospects of the Country-Domestic Animal Genetic Resources Information System (DAGRIS) of ILRI. This electronic database is designed to cater for the needs of researchers, policy makers, development practitioners, teachers, students and farmers in developing countries for efficient access to available published and grey literature from past and present research results on the origin, distribution, diversity, present use and status of selected Farm Animal Genetic Resources (FAnGR) of the countries. Development of the country-modules of c-DAGRIS in English and French for Anglophone and Francophone countries is finalized and ready to be used.

A study on applications of the natural ventilation pressure(NVP) in local tunnels (터널내 자연환기력(NVP) 적용방안 연구)

  • Kim, Hyo-Gyu;Yoo, Ji-Oh;Lee, Chang-Woo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.3
    • /
    • pp.269-285
    • /
    • 2014
  • In spite of the importance of the natural ventilation pressure(NVP) in tunnels for the optimal design of the ventilation system, there have been only few studies on the NVP because its measurement and quantitative analysis are not straightforward. This study aims at quantifying the amount of the NVP with the terrain and meteorological data for the local major tunnels. And ultimately this will lead to developing the guidelines for quantifying and applying NVP for the optimal design of tunnel ventilation system. 22 local tunnels in the major routes are studied for the NVP quantification. NVP derived from the meteorological data is in the range of 20~140 Pa, while NVP estimated from the terrain data ranges from 20 to 200 Pa. Since the jet fan pressure is about 10~15 Pa per unit, the minimum level of NVP expected in the local tunnels is larger than the pressure rise by one unit of the ordinary jet fan. This implies that NVP in local tunnels should be quantified and be taken into consideration for the economic and safe ventilation design. The barometric pressure difference between tunnel portals is found to be the most influential factor, accounting for 61% of the NVP, while the wind pressure acting on the portals and the chimney effects occupy 22% and 17%, respectively.

Flow and smoke behavior of a longitudinal ventilation tunnel with various velocities using computational fluid dynamics (팬의 운전조건에 따른 종류식환기터널 내의 연기거동에 관한 전산유체역학연구)

  • Lee, J.H.;Kwon, Y.J.;Kim, D.E.
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.1
    • /
    • pp.105-115
    • /
    • 2014
  • A numerical analysis on the smoke behavior and evacuee safety has been performed with computational fluid dynamics. The purpose of this study is to build computational processes for an evacuation and prevention of a fire disaster of a 3 km-length tunnel in Korea. To save computational cost, 1.5 km of the tunnel that can include a few cross-passing tunnels is considered. We are going to assess the fire safety in a road tunnel according to the smoke level, which consists of the smoke density and the height from the floor. The smoke density is obtained in detail from three-dimensional unsteady CFD analysis. To obtain proper temperature distributions on the tunnel wall, one-dimensional conduction equation is considered instead of an adiabatic wall boundary or a constant heat flux. The tunnel considered in this study equips the cross passing tunnels for evacuees every 250 m. The distance is critical in both safety and economy. The more cross passing tunnels, the more safe but the more expensive. Three different jet fan operations can be considered in this study; under- and over-critical velocities for normal traffic condition and 0-velocoty operation for the traffic congestion. The SE (smoke environment) level maps show a smoke environment and an evacuating behavior every moment.