• Title/Summary/Keyword: Jeong-a

Search Result 83,073, Processing Time 0.113 seconds

Analysis of Postoperative Coronary Angiography in Symptomatic Patients (관상동맥 우회술 시행 후 증상이 있는 환자에서 시행한 관상동맥 조영술의 분석)

  • Kim Young-Hak;Han San-Woong;Kang Jeong-Ho;Kim Hyuck;Lee Chul-Burm;Chon Soon-Ho;Nam Seung-Hyuk;Chung Won-Sang
    • Journal of Chest Surgery
    • /
    • v.39 no.10 s.267
    • /
    • pp.759-764
    • /
    • 2006
  • Background: We analyzed post-operative angiography performed in symptomatic patients to evaluate the patency rates and the roles of grafts. Material and Method: We reviewed 52 (15%) coronary angiograms performed for recurrent angina after prior coronary artery bypass surgery from January 1995 to June 2005. A total of 345 patients underwent coronary artery bypass surgery during this period. There were 41 men and 11 women and the mean age was $64.07{\pm}15.58$ years. The median period from operation to re-angiogram was 68.5 months (range, 1 to 126 months). The numbers of grafts and peripheral anastomoses were 42 and 43 for internal thoracic artery (ITA), 14 and 20 for radial artery (RA), and 49 and 89 for saphenous vein. The mean number of anastomosis was 2.9 per patient, Result: The patency rates of ITA, RA and saphenous vein graft (SVG) were 37/43 (86%), 17/20 (85%) and 34/89 (38.2%). The patency rate of arterial grafts was significantly higher than that of SVG (p< 0.001) and the patency rate of the RA was comparable to that of ITA (p=0.942). The patency rate of sequential SVGs was higher than that of single SVG (40.3% vs 31.8%, p=0.478) and the patency rate of proximal segments in sequential anastomosis was higher than that in single anastomsis (55.6% vs 31.8%, p=0.097), but statistically not significant. Conclusion: Arterial grafts have markedly superior patency rates than SVGs, so consideration should be given to the vigorous use of arterial grafts. The patency rate of the RA was comparable to that of ITA.

Influence of Glass Dielectric Property on the External Electrode Fluorescent Lamps (유리관의 유전 특성이 외부전극 형광램프에 미치는 영향)

  • Shin, Myeong-Ju;Jeong, Jong-Mun;Kim, Jung-Hyun;Kim, Ga-Eul;Lee, Mi-Ran;Yoo, Dong-Gun;Koo, Je-Huan;Hong, Byoung-Hee;Choi, Eun-Ha;Cho, Guang-Sup
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.5
    • /
    • pp.330-337
    • /
    • 2007
  • Influence of glass dielectric property (dielectric constant K, dielectric loss) on the external electrode fluorescent lamps of the dielectric barrier discharge has been investigated with 4-different glasses. Conventional borosilicate glass tubes with $K=5.6{\sim}5.9$ and tan ${\delta}=5.0{\times}10^{-3}{\sim}6.0{\times}10^{-3}$ and aluminosilicate glass tubes with high K=6.6 and low tan ${\delta}=1{\times}10^{-4}$ and soda-lime glass tribes with K=7.7 and tan ${\delta}=1.37{\times}10^{-2}$ have been compared. The high value of dielectric constant K makes the capacitance of external electrode fluorescent lamps intensity and enhances the discharge efficiency. The dielectric loss of tan ${\delta}$ shows the factor of power consumption in the external electrode to induce heats and to be weak in pinhole stability. The aluminosilicate glass tubes of high K and low tan ${\delta}$ have been enhanced by $14{\sim}18%$ in luminance and efficiency in comparison with the conventional borosilicate glass tubes and the aluminosilicate external electrode fluorescent lamps are strong against the pinhole formation. Soda-lime glass tubes with high K and high tan ${\delta}$ are a little favorable in luminance and efficiency and they are very weak in pinhole occurrence.

Old Service Pipe Cleaning of Polly-pigs Cleaning technique (Polly-pigs를 이용한 노후급수관의 세관에 관한 연구)

  • Lee, Hyun-Dong;Bae, Chul-Ho;Park, Jeong-Hoon;Kim, Gil-Nam
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.3
    • /
    • pp.303-312
    • /
    • 2002
  • Polly-pigs technique was developed to remove internal rusts and scales from service pipes in the building by using Polly-pigs that were used as various applications in conventional plant pipelines. Results of cleaning experiments on 15mm GSP(Galvanic Steel Pipe) showed that hydraulic cross sectional area was more increased from 3.5% to 15.4% for straight part or elbow parts of several test pieces. Results of optical analysis also showed that rust and scale removed mostly by KDP series(only consisted of Polyurethane) were outside red colored scale ($Fe_2O_3{\cdot}H_2O$), and there was a limitation to the removal of black colored scale($Fe_2O{\cdot}nH_2O$) that was below red colored scale. But it was evaluated that KDPS series coated fine sand with KDP series could remove not only red colored scale but also black colored scale and more increase hydraulic cross sectional areas of 15mm GSP old service pipes from 13.0% to 17.9%. After KDPS series cleaning, hydraulic cross sectional areas of them were recovered from 95.9% to 99.5%. Turning force of Polly-pigs was largely improved by the effect of Helical guide vane(Cleaning v/v) and Rotating wing(Pigs), and the number of pig rotating also more increased sixteen times compared with conventional cleaning system without Helical guide vane and Rotating wing. After KDPC series cleaning of 100mm GSP old service pipes that hydraulic cross sectional areas were 90%, hydraulic cross sectional areas were almost recovered perfectly like new service pipes. Additionally pressure necessary to run Polly-pigs m 100mm GSP was lower and cleaning efficiency also was higher than 15mm GSP cleaning. Therefore it was thought that as the diameter of pipe was more increased, pressure necessary to clean service pipes was more decreased and cleaning efficiency was more increased in Polly-pigs cleaning.

Comparison of $^{18}F$ FDG-PET and CT/MRI for the Diagnosis of Cervical Lymph Node Metastasis in Head and Neck Cancer: A Level-by-Level Based Study (두경부암 환자에서 경부 림프절 전이에 대한 $^{18}F$ FDG-PET과 CT/MRI의 진단적 정확도 비교: 림프절군에 따른 연구)

  • Yang, Yoo-Jung;Kim, Jae-Seung;Kim, Sang-Yun;Lee, Ho-Gyu;Nam, Soon-Yul;Choi, Seung-Ho;Ryu, Jin-Sook;Yeo, Jeong-Seok;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.52-61
    • /
    • 2004
  • Purpose: Cervical lymph node metastasis is the most important factor of the prognosis and therapeutic planning in head and neck cancer. With increasing interest of minimally invasive neck surgery, more accurate preoperative assessment of cervical lymph node becomes more essential. We evaluated the diagnostic accuracy of $^{18}F$ FDG-PET in the assessment of lymph node metastasis in patients with primary head and neck cancer and compared the results with those of CT/MRI. Materials and Methods: Thirty-two patients (M/F=27/5, $56{\pm}10yr$) with biopsy proven head and neck cancer (16 supraglottic cancer, 9 tongue cancer, 7 others) underwent FDG-PET and CT/MRI (25/7) within 1 month before neck dissection. Based on lymph node level, the diagnostic sensitivity and specificity of FDG PET and CT/MRI for the metastasis of cervical lymph node were compared. Results: Of 153 lymph node levels dissected in 32 patients, 32 lymph node levels of 19 patients were positive for metastasis by histopatholologic examination. The overall sensitivity and specificity of FDG-PET were 88% (28/32) and 93% (113/121), whereas those of CT/MRI were 56% (18/32) (p=0.002) and 92% (112/121), respectively. The diagnostic sensitivity and specificity of FDG-PET were different according to location of lymph node levels, and those of ipsilateral level 11 were lower than those of other levels. Conclusion: FDG-PET is more sensitive in detecting metastatic cervical lymph node in head and neck cancer than CT/MRI. FDG-PET might be useful in guiding the extent of neck dissection.

Comparison of Clinical Usefulness between N-13 Ammonia PET/CT and Tc-99m Sestamibi SPET in Coronary Artery Disease (관상동맥질환에서 N-13 암모니아 PET/CT와 Tc-99m 세스타미비 SPECT의 임상 유용성 비교)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Chun, Kyung-Ah;Won, Kyu-Chang;Lee, Hyung-Woo;Park, Jeong-Sun;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Seop
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.354-361
    • /
    • 2008
  • Purpose: N-13 ammonia uptake and retention in the myocardium is related to perfusion and metabolism. There are several potential advantages of N-13 ammonia positron emission tomography (PET) to detect myocardial ischemia, such as higher spatial resolution, greater counting efficiencies, and robust attenuation correction. But there are few reports comparing Tc-99m myocardial perfusion single photon emission tomography (MPS) and N-13 ammonia PET. We thus compared adenosine stress N-13 ammonia PET/CT and Tc-99m sestamibi MPS in patients with suspected coronary artery stenosis. Materials and Methods: Seventeen patients (male 13 : $63{\pm}11$ years old) underwent adenosine stress N-13 ammonia PET/CT (Discovery ST, GE), Tc-99m sestamibi MPS (dual head gamma camera, Hawkeye, GE) and coronary angiography within 1 week. N-13 ammonia PET/CT and Tc-99m sestamibi MPS images were assessed with a 20-segment model by visual interpretation and quantitative analysis using automatic quantitative software (Myovation, GE). Results: Both sensitivities and specificities of detecting an individual coronary artery stenosis were higher for N-13 ammonia PET/CT than Tc-99m sestamibi MPS (PET/CT: 91%/89% vs MPS: 65%/82%). N-13 ammonia PET/CT showed reversibility in 52% of segments that were considered non-reversibile by Tc-99m sestamibi MPS. In the 110 myocardial segments supplied by the stenotic coronary artery, N-13 ammonia PET/CT showed higher count densities than Tc-99m MPS on rest study (p < 0.01), and the difference of count density between the stress and the rest studies was also larger on N-13 ammonia PET/CT. Conclusion: Adenosine stress N-13 ammonia PET/CT had higher diagnostic sensitivity and specificity, more reversibility of perfusion defects and greater stress/rest uptake differences than Tc-99m sestamibi MPS. Accordingly, N-13 ammonia PET/CT might offer better assessment of myocardial ischemia and viability.

Investigation of the Utilization of Organic Materials and the Chemical Properties of Soil in the Organic Farms in Korea (국내 유기농재배지 유기물 시용실태 및 토양의 화학적 특성)

  • Lee Yong-Hoan;Lee Sang-Guei;Kim Sung-Hoan;Shin Jae-Hoon;Choi Doo-Hoi;Lee Yun-Jeong;Kim Han-Myeng
    • Korean Journal of Organic Agriculture
    • /
    • v.14 no.1
    • /
    • pp.55-67
    • /
    • 2006
  • A survey of 31 organic farmers were conducted to investigate the actual conditions of organic matter application. The amounts of organic matter application in the fields were higher in order of fruit, vegetable and rice farm. The average was 50 ton/ha in vegetable farms. In the green vegetable farms saw dust and animal manure were mainly utilized to make compost. Rice straw, wood chip, and forest bushes were also used for composting. In the fruit vegetable farms materials relatively lower in nitrogen content such as rice straw and cattle manure were used in vegetative period and materials higher in nitrogen content such as oil cake and wild grass were used in reproductive phase. Nutrient balance investigated in the farm in Icheon region who produce lettuce, angelica, and kale continuously in one cropping year indicated surplus in three major nutrients. Nitrogen and phosphorous were in excess by 29 and 10 kg respectively in the organic rice farm in yang-pyoung region. While soil chemical properties in the organic farms are within the adequate range in open field, it is much higher than the limits in the greenhouse soils. Overall application of organic matter is in an oversupply state. This results suggested that the organic matter management should be based on the soil conditions for sustainable cultivation. Chemical composition of organic matters and soil test reports should be considered prior to the application of organic matter.

  • PDF

Crop Analysis through Growth Survey after Wintering of Winter Annual Forages Grown from 2014 to 2015 (2014 / 2015년 동계 사료작물의 월동 후 생육조사를 통한 작황 분석)

  • Kim, Young-Jin;Kim, Won-Ho;Lee, Sang-Hoon;Park, Hyung-Soo;Kim, Ki-Yong;Ji, Hee-Chung;Choi, Ki-Choon;Lee, Sang-Hak;Jung, Jeong-Sung;Kim, Ji-Hea;Hwang, Tae-Young;Lee, Ki-Won;Kim, Hyeon-Shup;Choi, Gi-Jun
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.35 no.4
    • /
    • pp.309-315
    • /
    • 2015
  • In order to identify the causes of various problems related to forage crop growth, such as winter survival, coldness, rainfall, drought etc., and to provide basic data for the stable production and supply of forage year round, we performed a growth survey after the wintering of winter forage crops grown from mid-Sep. 2014 to late-Feb. 2015. The growth of winter forage crops after wintering in the country was generally bad. As shown in the regional distribution in the country, regions with 80% or higher winter survival rates comprised 66%, regions with 79 to 50% winter survival comprised 24.9% and regions with less than 50% winter survival comprised 9.1%. In conclusion, the average winter survival rate was 79% in the country. Winter survival rate and coverage rate after the wintering of winter forage crops under installed drain channels in paddy fields were good at 83% and 80%, respectively. However, the rates without installed drain channels were bad at 67% and 66%, respectively. It was predicted that the crop production of winter forage crops was reduced by 10-15% in Gangwon, Chungbuk, Chungnam, Gyeongnam and Jeonnam regions, reduced by 30% in Gyeonggi, Gyeongbuk and Jeonbuk regions and reduced overall by approximately 19% nationwide.

Effects of Gamma Irradiation on Antioxidant, Antimicrobial Activities and Physical Characteristics of Sargassum thunbergii Extract (지충이 추출물의 항산화, 항균 활성 및 물리적 특성에 미치는 감마선 조사의 영향)

  • Lee, So-Jeong;Song, Eu-Jin;Lee, So-Young;Kim, Koth-Bong-Woo-Ri;Yoon, So-Young;Lee, Chung-Jo;Jung, Ji-Yeon;Park, Na-Bi;Kwak, Ji-Hee;Park, Jin-Gyu;Kim, Jae-Hun;Choi, Jong-Il;Lee, Ju-Woon;Byun, Myung-Woo;Ahn, Dong-Hyun
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.431-437
    • /
    • 2010
  • This study was carried out to determine the effect of gamma irradiation (3-20 kGy) on the antioxidant, antimicrobial activities and physical characteristics of Sargassum thunbergii (ST) extracts. When ST powder was treated by gamma irradiation, the yields and total phenolic compounds (TPC) of water extracts were increased, but radical scavenging activities were not changed. When ST extract was irradiated, the TPC and DPPH radical scavenging activities were increased. In addition, gamma irradiation of ST extract decreased viscosity and removed color. These results suggest that gamma irradiation would be a useful method for improving the physical characteristics of ST extract while maintaining native biological activities.

Comparative Analysis of Nutrients and Hazardous Substances in Zophobas atratus Larvae (탈지 전, 후 아메리카왕거저리(Zophobas atratus) 유충의 영양성분 및 유해물질 비교분석)

  • Kim, Sun Young;Kim, Hong Geun;Ko, Hyeon-Jin;Kim, Mi Ae;Kim, In Woo;Seo, Minchul;Lee, Joon Ha;Lee, Hwa Jeong;Baek, Minhee;Hwang, Jae Sam;Yoon, Hyung Joo
    • Journal of Life Science
    • /
    • v.29 no.12
    • /
    • pp.1378-1385
    • /
    • 2019
  • The nutritional composition and optimal eating stage of the super mealworm, Zophobas atratus (Coleoptera : Tenebrionidae), were investigated to explore its use as a food ingredient. It was determined that 10th instar larvae were most suitable for eating in terms of nutritional value as well as economic aspects. To improve the quality of powder production, the nutritional value of 10th instar larvae before and after degreasing was analyzed. After drying the larvae powder, crude protein was the most abundant nutrient both before (52.3%) and after (60.6%) degreasing while crude fat measured 36.3% and 21.7% before and after degreasing, respectively. In terms of essential amino acids, leucine levels were highest and 1.3 times greater after degreasing (4.5%) than before (3.5%). Oleic acid, the highest unsaturated fatty acid in larvae, was 31.7% after degreasing which was 1.1 times higher than before (33.2%). Among various major minerals, potassium was most abundant and 1.4 times higher after degreasing (1267.0 mg/100 g) than before (879.3 mg/100 g). Harmful substances were 1.3 to 2.0 times lower in the degreased larvae, although mercury or pathogenic bacteria were not detected in either group. We therefore conclude that degreased Z. atratus larvae are more suitable for eating than before degreasing.

Development of Multiplex PCR Assay for Identification of Eight Species from Meats in Korea (국내에서 유통되는 8종의 식육감별을 위한 multiplex PCR법 개발)

  • Heo, Eun-Jeong;Ko, Eun-Kyung;Yoon, Hyang-Jin;Kim, Yeon-Hwa;Kim, Young-Jo;Park, Hyun-Jung;Wee, Sung-Hwan;Moon, Jin-San
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.1
    • /
    • pp.28-35
    • /
    • 2016
  • Species identification of animal tissues in meat products is an important issue to protect the consumer from illegal and/or undesirable adulteration; for economic, religious and health reasons. In this reason, accurate analytical methods are needed for the labeling of meat products with requiring simple and fast procedure. Recently, applications of PCR in food analysis have been increased because of their simplicity, specificity and sensitivity. Therefore, in this study, a multiplex PCR assay was developed for the simultaneous identification of eight species of cow, pig, chicken, duck, goat, sheep, horse and turkey from raw meats. The primers were designed in different regions of mitochondrial 16S RNA after alignment of the available sequences in the GenBank database. Two multiplex primer sets were designed as Set 1 (cow, pig, chicken, duck) and Set 2 (goat, sheep, horse, turkey), respectively. Total 274 samples from cow (n = 55), pig (n = 30), chicken (n=30), and duck (n = 30), goat (n = 40), sheep (n = 33), horse (n = 41), and turkey (n = 15) were tested. The primers generated specific fragments of 94, 192, 279, 477 bp (pig, chicken, cow, duck), 670, 271, 152, 469 bp (goat, sheep, horse, turkey) lengths for eight species, respectively. The animal species specificity was 100% in all eight samples in the multiplex PCR assay. The detection limit of the multiplex PCR assay showed from 100 fg to 1 pg of template DNA from extracted from raw meats. When applying multiplex PCR assays to sample from pork/beef and pork/chicken, beef/chicken tested raw mixed meats and heat-treated ($83^{\circ}C$ for 30min, $100^{\circ}C$ for 20min, and $121^{\circ}C$ for 10min) mixtures, detection limit was 0.1% level beef, pork and pork in beef and chicken in pork and 1.0% level pork in chicken. This study suggest that the developed multiplex PCR assay can be used for rapid and simultaneous species identification of cow, pig, chicken, duck, goat, sheep, horse and turkey from meats.