• Title/Summary/Keyword: Jeong-a

Search Result 83,073, Processing Time 0.116 seconds

Early Changes of Left Ventricular Geometry and Function after Surgical Ventricular Restoration and Mitral Valve Annuloplasty: Magnetic Resonance Imaging (외과적 심실 복원과 승모판 고리성형 후 좌심실 형태와 기능의 초기 변화: 자기공명영상)

  • Choi, Byoung-Wook;Chang, Byung-Chul;Kim, Young-Jin;Hur, Jin;Lee, Hye-Jeong;Kim, Tae-Hoon;Choe, Kyu-Ok
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.1
    • /
    • pp.40-48
    • /
    • 2008
  • Purpose : We sought to determine the early change of ventricular geometry and function after concomitant surgeries of modified Dor procedure and mitral valve annuloplasty by using magnetic resonance imaging. Materials and Methods : We enrolled 21 patients with dilated heart failure who underwent modified Dor procedure (n=8), mitral valve annuloplasty (n=6), or both surgeries (n=7). Cine MRI was used to assess left ventricular dimensions and function before and after surgery. We measured the left ventricular end-diastolic and end-systolic volumes and the dimensions of the left ventricular long-axis and short-axis. Left ventricular stroke volume, ejection fraction, and sphericity index were calculated from these measurements. These parameters were analyzed and compared between three different surgery groups to explain the combined effect of the concomitant surgeries. Results : MRI was performed within average $12\;{\pm}\;15$ days (range 1-58 days) before and $38\;{\pm}\;50$ days (range 7- 231 days) after the surgery. The patients who underwent concomitant surgeries had more profound enlargement of left ventricle and decreased contractility prior to surgery than those in the patients who underwent single surgical procedure. Left ventricular end-diastolic volume and endsystolic volume significantly decreased in all patients regardless of surgery type after surgery. Ejection fraction significantly increased only in the patients who got modified Dor procedure without mitral valve annuloplasty (25.4% to 40.7%). Sphericity index increased in patients with modified Dor procedure but decreased in patients with mitral valve annuloplasty (0.65 to 0.78 vs. 0.75 to 0.65). In the patients who underwent concomitant surgeries showed no significant change in sphericity index after surgery. Conclusion : The early change of the left ventricular geometry and function after the concomitant surgeries with modified Dor procedure and mitral valve annuloplasty in patients with dilated heart failure includes a marked reduction in left ventricular volume and in stroke volume. The shape of the left ventricle does not change because the effect of sphericity index decrease from mitral valve annuloplasty is counteracted by the effect of sphericity index increase from modified Dor procedure. Improvement of left ventricular ejection fraction is not the early change after the concomitant surgeries.

  • PDF

Water Treatment Application of a Large Pore Micro-Filtration Membrane and Its Problems (대기공 정밀여과막의 수처리 응용 및 문제점)

  • Yun, Chang-Han;Kim, Jeong-Hak;Lee, Kang Won;Park, Sung Ho
    • Membrane Journal
    • /
    • v.24 no.3
    • /
    • pp.194-200
    • /
    • 2014
  • The purpose of this study was to evaluate the performance of newly developed Large Pore Micro-Filtration (LPMF) membrane in Lab size for the application of water treatment, and to find its problems with solutions. The out-to-inside filtration hollow fiber LPMF membrane of which average pore size was $5{\mu}m$ was used at this study and its material was the PET braid reinforced PVDF. Filtration tests were done through gravity with 30 cm water head difference or pressure below 1.5 bar, and the backwash was done instantaneously with the filtrate after pressurizing it to about 4 bar. The water flux of the LPMF membrane with 0.2 bar TMP (Trans Membrane Pressure) was 2 times higher than $0.4{\mu}m$ MF membrane with $0.05{\mu}m$ UF filtrate of the tap water and it was measured also with 20~30 cm water head difference which showed over 800 LMH at 30 cm water head difference. And Time-To-Filter (TTF) was performed by using $5{\mu}m$ filter paper to optimize coagulants and dosage which enhanced filtrate's turbidity and stabilized filtration flux. When the LPMF was operated with 30 cm gravity with very high dose of inorganic coagulants, the flux was maintained over 80 LMH with 93.5~99.5% turbidity removal. Especially, the filtration was maintained stably in the flux and about 97% of the recovery rate by instantaneous pressurized backwash with about 4 bar of the filtrate when the packing density was about 19%. But there was instability in filtration, since the TMP was continuously going up by inefficient backwash when the packing density was 43%.

Distribution and Antimicrobial Susceptibility of Bacteria in the Oral Cavity of Smokers or Non-Smokers (흡연자와 비흡연자간의 구강 내 세균 분포 및 항균제 감수성)

  • Jeong, Hyun-Ja;Kim, Su-Jung
    • Korean Journal of Microbiology
    • /
    • v.46 no.4
    • /
    • pp.334-340
    • /
    • 2010
  • It is well known that smoking as well as drinking is a factor of stomatopathy, however there are few investigations about comparison of oral flora between smokers and non-smokers. In this study, we isolated the oral flora of 30 smokers and 30 non-smokers and cultured them on blood agar plates. The isolated pathogenic microorganisms were tested for antibiotic susceptibility and resistance using the Kirby-Bauer antibiotic testing method. Each colony was stained using the Gram staining method and was identified by an automatic identifier, known as the VITEK system. We isolated 41 colonies from smokers' oral cavity, and they were sorted as 63% of Gram-positive cocci, 29% of Gram-negative cocci, 3% of Gram-positive bacilli, and 5% of Gram-negative bacilli by gram staining, whereas 38 colonies were isolated from non-smoters' oral cavity, and their proportions were 55% of Gram-positive cocci, 26% of Gram-negative cocci, 3% of Gram-positive bacilli, and 16% of Gram-negative bacilli. The VITEK system revealed specific distribution of bacteria species that Streptococcus mutans (6/41), Gemella morillorum (6/41), Streptococcus oralis (2/41), Streptococcus pneumoniae (1/41), Staphylococcus aureus (3/41), Streptococcus anginosus (1/41), Streptococcus intermedius (1/41), Streptococcus uberis (1/41), and Streptococcus sanguinis (1/41) in smokers oral cavity whereas Streptococcus sanguinis (8/38), Staphylococcus aureus (1/38), Staphylococcus auricularis (1/38), Streptococcus uberis (1/38), Streptococcus intermedius (1/38), Streptococcus mutans (1/38), and Streptococcus oralis (1/38) in those of non-smokers'. Three cases of Staphylococcus aureus from smokers produced Beta-lactamase and were identified methicillin-resistance Staphylococcus aureus (MRSA). However one case of Staphylococcus aureus from non-smoker did not produce Beta-lactamase and was sensitive to methicillin. In conclusion, the distribution of oral flora was different between smokers' and non-smokers' oral cavity, especially Gemella morillorum and MRSA were predominantly found in smoker's oral cavity. These results are useful in the treatment and prevention of patients with stomatopathy caused by smoking.

Real-Time PCR for Quantitative Detection of Bovine Herpesvirus Type 1 (Bovine Herpesvirus Type 1 정량 검출을 위한 Real-Time PCR)

  • Lee, Dong-Hyuck;Jeong, Hyo-Sun;Lee, Jung-Hee;Kim, Tae-Eun;Lee, Jung-Suk;Kim, In-Seop
    • Korean Journal of Microbiology
    • /
    • v.44 no.1
    • /
    • pp.14-21
    • /
    • 2008
  • Bovine blood, cell, tissue, and organ are used as raw materials for manufacturing biopharmaceuticals, tissue engineered products, and cell therapy. Manufacturing processes for the biologicals using bovine materials have the risk of viral contamination. Therefore viral validation is, essential in ensuring the safety of the products. Bovine herpesvirus type 1 (BHV-1) is the most common bovine pathogen found in bovine blood, cell, tissue, and organ. In order to establish the validation system for the BHV-1 safety of the products, a real-time PCR method was developed for quantitative detection of BHV-1 in raw materials, manufacturing processes, and final products as well as BHV-1 clearance validation. Specific primers for amplification of BHV-1 DNA was selected, and BHV-1 DNA was quantified by use of SYBR Green I. The sensitivity of the assay was calculated to be $2\;TCID_{50}/ml$. The real-time PCR method was validated to be reproducible and very specific to BHV-1. The established real-time PCR assay was successfully applied to the validation of Chinese hamster ovary (CHO) cell artificially infected with BHV-1. BHV-1 DNA could be quantified in CHO cell as well as culture supernatant. Also the real-time PCR assay could detect $10\;TCID_{50}/ml$ of BHV-1 artificially contaminated in bovine collagen. The overall results indicated that this rapid, specific, sensitive, and robust assay can be reliably used for quantitative detection of BHV-1 contamination during the manufacture of biologics.

Location Service Modeling of Distributed GIS for Replication Geospatial Information Object Management (중복 지리정보 객체 관리를 위한 분산 지리정보 시스템의 위치 서비스 모델링)

  • Jeong, Chang-Won;Lee, Won-Jung;Lee, Jae-Wan;Joo, Su-Chong
    • The KIPS Transactions:PartD
    • /
    • v.13D no.7 s.110
    • /
    • pp.985-996
    • /
    • 2006
  • As the internet technologies develop, the geographic information system environment is changing to the web-based service. Since geospatial information of the existing Web-GIS services were developed independently, there is no interoperability to support diverse map formats. In spite of the same geospatial information object it can be used for various proposes that is duplicated in GIS separately. It needs intelligent strategies for optimal replica selection, which is identification of replication geospatial information objects. And for management of replication objects, OMG, GLOBE and GRID computing suggested related frameworks. But these researches are not thorough going enough in case of geospatial information object. This paper presents a model of location service, which is supported for optimal selection among replication and management of replication objects. It is consist of tree main services. The first is binding service which can save names and properties of object defined by users according to service offers and enable clients to search them on the service of offers. The second is location service which can manage location information with contact records. And obtains performance information by the Load Sharing Facility on system independently with contact address. The third is intelligent selection service which can obtain basic/performance information from the binding service/location service and provide both faster access and better performance characteristics by rules as intelligent model based on rough sets. For the validity of location service model, this research presents the processes of location service execution with Graphic User Interface.

Investigation of Measurement Feasibility of Particulate Matter Concentration by Different Land-Use Types Using Drone (드론을 이용한 토지이용별 미세먼지 농도 측정 가능성 모색 연구)

  • Son, Seung-Woo;Yu, Jae-Jin;Kim, Dong-Woo;Kim, Tae-Hyun;Sung, Woong-Gi;Yoon, Jeong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.259-267
    • /
    • 2020
  • This study measured the Particulate Matter (PM) concentration according to altitude (30 m, 60 m, 90 m, 120 m, and 150 m) in three different environments: a construction site, natural environment (arboretum), and residential area. PM2.5 and PM10 values at 30 m above the construction site were 18.63 ㎍/㎥ and 24.23 ㎍/㎥ while values at 150 m were 10.89 ㎍/㎥ and 10.61 ㎍/㎥, respectively, indicating the average concentration decreased as altitude increased. PM2.5 and PM10 values at 30 m above the natural environment were 9.03 ㎍/㎥ and 11.21 ㎍/㎥ while those at 150 m were 3.42 ㎍/㎥ and 3.57 ㎍/㎥, respectively, showing lower average concentrations as altitude increased. PM2.5 and PM10 values at 30 m above the residential area were 10.65 ㎍/㎥ and 12.06 ㎍/㎥ while those at 150 m were 4.24 ㎍/㎥ and 5.17 ㎍/㎥, also demonstrating lower PM concentrations as altitude increased. The PM concentrations decreased as altitude increased at all tested sites and also decreased between environments in the following order: construction site, residential area, and natural environment. The results of this study are significant because PM concentrations were measured at various altitudes at different land-use sites. The results are expected to serve as basic data for decision-making in both regional and urban planning.

The Differences of Self Efficacy, Self-esteem and Vitality according to the Physical Exercise, Thinking about Health of Nursing Students (간호학생의 운동수행여부, 건강에 대한 생각에 따른 자기효능감, 자아존중감 및 활력정도의 차이)

  • Jeong, Gye-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.117-125
    • /
    • 2020
  • This study was conducted to investigate differences in self-efficacy, self-esteem, and vitality related to physical exercise and health consciousness. A descriptive research design, x2 test, and t test were used. Data were collected from May 1 to June 30, 2019, at K city. Participants were 220 nursing students of mean age 23.7 years; 187 (85.5%) were women, 99 (45.0%) exercised regularly; 138 (62.7%) were positive about their health Ed. Note: Please confirm that these edits convey your intended meaning. The scores Ed. Note: This is not clear. Here, do you mean "mean scores of all participants"? of self-efficacy of health and body were 2.93±0.35 and 3.16±0.37, respectively; self-esteem, 2.94±0.43; and vitality, 3.78±0.52. There were significant differences in self-efficacy of health (t=3.68, p=<.001), motor function (t=5.39, p<.001), psychological function (t=2.10, p=.037), nutritional function (t=2.50, p=.013), efficacy of health management (t=2.37, p=.019), and vitality (t=12.63, p=<.001) related to physical exercise. Self-efficacy of health (t=3.73, p=<.001), motor function (t=3.29, p=.001), psychological function (t=4.01, p<.001), nutritional function (t=2.62, p=.009), efficacy of health management (t=2.51, p=.013), self-efficacy of body (t=2.59, p=.010), self-esteem (t=3.91, p=<.001), and vitality (t=2.92, p=.004) were related to health consciousness. Physical exercise and previous experience of body weight loss contributed to enhanced self-efficacy of health and vitality and health consciousness contributed to enhanced self-efficacy of health and body, self-esteem, and vitality.

Compression Sensing Technique for Efficient Structural Health Monitoring - Focusing on Optimization of CAFB and Shaking Table Test Using Kobe Seismic Waveforms (효율적인 SHM을 위한 압축센싱 기술 - Kobe 지진파형을 이용한 CAFB의 최적화 및 지진응답실험 중심으로)

  • Heo, Gwang-Hee;Lee, Chin-Ok;Seo, Sang-Gu;Jeong, Yu-Seung;Jeon, Joon-Ryong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.23-32
    • /
    • 2020
  • The compression sensing technology, CAFB, was developed to obtain the raw signal of the target structure by compressing it into a signal of the intended frequency range. At this point, for compression sensing, the CAFB can be optimized for various reference signals depending on the desired frequency range of the target structure. In addition, optimized CAFB should be able to efficiently compress the effective structural answers of the target structure even in sudden/dangerous conditions such as earthquakes. In this paper, the targeted frequency range for efficient structural integrity monitoring of relatively flexible structures was set below 10Hz, and the optimization method of CAFB for this purpose and the seismic response performance of CAFB in seismic conditions were evaluated experimentally. To this end, in this paper, CAFB was first optimized using Kobe seismic waveform, and embedded it in its own wireless IDAQ system. In addition, seismic response tests were conducted on two span bridges using Kobe seismic waveform. Finally, using an IDAQ system with built-in CAFB, the seismic response of the two-span bridge was wirelessly obtained, and the compression signal obtained was cross-referenced with the raw signal. From the results of the experiment, the compression signal showed excellent response performance and data compression effects in relation to the raw signal, and CAFB was able to effectively compress and sensitize the effective structural response of the structure even in seismic situations. Finally, in this paper, the optimization method of CAFB was presented to suit the intended frequency range (less than 10Hz), and CAFB proved to be an economical and efficient data compression sensing technology for instrumentation-monitoring of seismic conditions.

Aided Distance Visual Acuity and Refractive Error Changes by Using Smartphone (스마트폰 사용이 원거리 교정시력과 굴절 이상 변화에 미치는 영향)

  • Kim, Bong-Hwan;Han, Sun-Hee;Shin, Young Gul;Kim, Da Yeong;Park, Jin Young;Sin, Won Chul;Yoon, Jeong Ho
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.305-309
    • /
    • 2012
  • Purpose:This study was conducted to research any effect on aided distance visual acuity and refractive error changes by using smartphone at near for long term. Methods: 20($20.6{\pm}0.9$ years) young adults subjects with no ocular diseases, over 0.8 of aided distance visual acuity, normal amplitude of accommodation and normal accommodative facility agreed to participate in this study. The subjects were divided into two group, Group 1 (15 cm fixation distance) included 10 subjects and Group 2(40 cm fixation distance) included 10 subjects. Aided distance visual acuity and refractive error were measured before and after using smartphone for 30 minutes by auto-chart project (CP-1000, Dongyang, Korea), phoropter (VT-20, Dongyang, Korea), auto refractor-keratometer (MRK-3100, Huvitz, Korea). After then, the subjects looked at distance with wearing spectacles. Refractive error was measured at 5 minutes, 10 minutes, and 15 minutes later, respectively. Results: After using smartphone at 15 cm for 30 minutes, there was statistically significant reduction of aided distance visual acuity (p=0.030) and increasing myopia (p=0.001). The increased myopia was not statistically significant after 5 minutes rest (p${\geq}$0.464). However there was no statistically significant changes in aided distance visual acuity (p=0.163) and refractive error (p=0.077) after using smartphone at 40 cm for 30 minutes. Conclusions: It is recommend to keep 40 cm off the smartphone from eyes to avoid any aided distance visual acuity and refractive error changes. If smartphone is used closer than 40 cm, a rest for 5 minutes is also recommend after every 30 minutes use with smartphone to avoid any aided distance visual acuity and refractive error changes.

Effect of Far-Infrared Irradiation on the Antioxidant Activity of Extracts from Grape Seed (포도씨의 항산화능에 대한 원적외선 처리의 효과)

  • Jeong, Seok-Moon;Kim, So-Young;Ha, Jung-Uk;Lee, Seung-Cheol
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.10
    • /
    • pp.1619-1624
    • /
    • 2005
  • The effect of far-infrared (FIR) irradiation on the antioxidant activity of extracts from grape seed (GS) was evaluated. GS (5 g) were placed in Pyrex petri dishes (8.0 cm diameter) md FIR irradiated at 150$^{\circ}C$ for 10, 20, 30, 40 or 60 min with a FIR heater. After FIR irradiation, water extract (WE) (1.0 g/10 mL), methanol extract (ME) (1.0 g/10 mL) and 70$\%$ ethanol extract (EE) (1.0 g/10 mL) of GS were prepared, and total phenol contents (TPC) and radical scavenging activity (RSA) of the extracts were determined. The antioxidant activities of GS extracts increased as FIR irradiation. For example, FIR irradiation of GS at 150$^{\circ}C$ for 10 min increased the TPC and RSA of WE from 0.95 mM to 1.84 mM and 33,87$\%$ to 58.55$\%$, respectively, compared to non-irradiated control. In the case of ME at the same conditions of FIR irradiation (150$^{\circ}C$ for 10 min), the TPC and RSA also increased from 3.4 mM to 4.52 mM and 76.55$\%$ to 89.41$\%$, respectively. The TPC and RSA of EE increased from 2.65 mM to 4.82 mM and 66.89$\%$ to 84.62$\%$, too. According to the GC/MS analysis, several low-molecular-weight phenolic compounds such as vanillic acid and 3,4-hydroxy benzoic acid were newly formed in the EE after FIR irradiated at 150$^{\circ}C$ for 10 min. There were slight differences in the kinds of phenolic compounds between EE of non irradiated control and FIR irradiated samples. These results indicated that FIR irradiation onto GS could enhance antioxidant activities of its extracts with increasing the amount of phenolic compounds.